Loading...
HomeMy WebLinkAboutDDW-2024-006586PALMER SUBDIVISION CONSTRUCTION DOCUMENTS 3/13/2024 3/13/2024 DESIGNING OUR FUTURE C001 INDEX MA R K : DA T E : DE S C R I P T I O N : CA C H E V A L L E Y | P : 4 3 5 . 2 1 3 . 3 7 6 2 SA L T L A K E | P : 8 0 1 . 2 1 6 . 3 1 9 2 UT A H V A L L E Y | P : 8 0 1 . 8 7 4 . 1 4 3 2 in f o @ c i v i l s o l u t i o n s g r o u p . n e t ww w . c i v i l s o l u t i o n s g r o u p . n e t PROJECT #: 21-381 DRAWN BY: L. MUMFORD PROJECT MANAGER: M. TAYLOR ISSUED:3/13/2024 PA L M E R S U B D I V I S I O N 31 0 E A S T 8 9 0 0 N O R T H PA R A D I S E , U T 8 4 3 2 8 HATUFOETATS PR O F E S S I O NAL ENGI N E E R No. 8243188-2202 MICHAEL E. TAYLOR P: \ 2 0 2 1 \ 2 1 - 3 8 1 p a l m e r s u b d i v i s i o n - p a r a d i s e \ A u t o C A D \ C i v i l \ s h e e t s e t \ 2 1 - 3 8 1 C o v e r & L e g e n d THESE PLANS AND SPECIFICATIONS ARE THE PROPERTY OF CIVIL SOLUTIONS GROUP, INC. AND SHALL NOT BE PHOTOCOPIED, RE-DRAWN, OR USED ON ANY OTHER PROJECT OTHER THAN THE PROJECT SPECIFICALLY DESIGNED FOR, WITHOUT WRITTEN PERMISSION. THE OWNERS AND ENGINEERS OF CIVIL SOLUTIONS GROUP, INC. DISCLAIM ANY LIABILITY FOR ANY CHANGES OR MODIFICATIONS MADE TO THESE PLANS OR THE DESIGN THEREON WITHOUT THEIR CONSENT. THESE PLANS ARE DRAWN TO SCALE WHEN PLOTTED ON A 24" X 36" SHEET OF PAPER. THESE PLANS ARE PRODUCED IN COLOR AND SHOULD BE PLOTTED AS SUCH. VICINITY MAP 1" = 1000' 30 0 E PROJECT LOCATION 8800 S 8900 S 9000 S 20 0 E 10 0 E BR I D G E R B L V D . 10 0 W 20 0 W PARADISE CEMETARY GENERAL NOTES: 1.CURRENT ZONE: R-1.25 2.SETBACKS: PER TOWN CODE 3.ALL EXPENSES INVOLVING THE NECESSARY IMPROVEMENTS OR EXTENSIONS FOR A CULINARY WATER SYSTEM, SANITARY SEWER SYSTEM, GAS SERVICE, ELECTRICAL SERVICE, TELEPHONE SERVICE, GRADING AND LANDSCAPING, STORM DRAINAGE, STREET LIGHTING AND OTHER IMPROVEMENTS SHALL BE PAID FOR BY THE DEVELOPER. 4.ELEVATIONS SHOWN ARE TIED TO NATIONAL GEODETIC SURVEY CACHE COUNTY BRASS CAP MONUMENT MARKING THE SOUTH 1/4 CORNER OF SECTION 27, T10N, R1E, S.L.B.& M WITH ELEVATION 5007.31, NAVD88 DATUM. 5.PARADISE MONUMENT KNOWN ELEVATION=4543.58. 1.APPROVAL OF THESE PLANS BY THE TOWN ENGINEER DOES NOT AUTHORIZE ANY WORK TO BE PERFORMED UNTIL A NOTICE TO PROCEED HAS BEEN ISSUED. 2.THE APPROVAL OF THIS PLAN OR ISSUANCE OF A PERMIT BY THE TOWN OF PARADISE DOES NOT AUTHORIZE THE SUBDIVIDER AND OWNER TO VIOLATE ANY FEDERAL, STATE OR CITY LAWS, ORDINANCES, REGULATIONS, OR POLICIES. 3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR SURVEY MONUMENTS AND/OR VERTICAL CONTROL BENCHMARKS WHICH ARE DISTURBED OR DESTROYED BY CONSTRUCTION. A SURVEY CREW MUST FIELD LOCATE, REFERENCE, AND/OR PRESERVE ALL HISTORICAL OR VERTICAL CONTROLLING MONUMENTS PRIOR TO ANY EARTHWORK. IF DESTROYED, A SURVEY CREW SHALL REPLACE SUCH MONUMENTS WITH APPROPRIATE VERTICAL CONTROLLING MONUMENTS. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE COST OF REPLACING ANY VERTICAL CONTROL BENCHMARKS DESTROYED BY THE CONSTRUCTION. 4.CONTRACTOR SHALL CONTACT "BLUE STAKES" PRIOR TO START OF CONSTRUCTION ACTIVITIES BY CALLING 811 OR SUBMITTING AN ONLINE UTILITY LOCATION REQUEST AT WWW.BLUESTAKES.ORG. 5.CONTRACTOR SHALL IMPLEMENT AN EROSION AND SEDIMENT CONTROL PROGRAM DURING THE PROJECT GRADING AND/OR CONSTRUCTION ACTIVITIES. THE PROGRAM SHALL MEET ALL APPLICABLE REQUIREMENTS OF THE STATE OF UTAH AND PARADISE. 6."PUBLIC IMPROVEMENT SUBJECT TO DESUETUDE OR DAMAGE." IF REPAIR OR REPLACEMENT OF SUCH PUBLIC IMPROVEMENTS IS REQUIRED, THE OWNER SHALL OBTAIN THE REQUIRED PERMITS FOR WORK IN THE PUBLIC RIGHT-OF-WAY, SATISFACTORY TO THE PERMIT- ISSUING AUTHORITY. 7.PRIOR TO ANY DISTURBANCE TO THE SITE, EXCLUDING UTILITY MARK-OUTS AND SURVEYING, THE CONTRACTOR SHALL MAKE ARRANGEMENTS FOR A PRE-CONSTRUCTION MEETING WITH THE TOWN OF PARADISE. 8.DEVIATIONS FROM THESE SIGNED PLANS WILL NOT BE ALLOWED UNLESS A CONSTRUCTION CHANGE IS APPROVED BY THE TOWN ENGINEER OR THE CHANGE IS REQUIRED BY THE TOWN INSPECTOR. 9.THE AREA WHICH IS DEFINED AS A NON GRADING AREA AND WHICH IS NOT TO BE DISTURBED SHALL BE STAKED PRIOR TO START OF THE WORK. THE PERMIT APPLICANT AND ALL OF THEIR REPRESENTATIVES OR CONTRACTORS SHALL COMPLY WITH THE REQUIREMENTS FOR PROTECTION OF THIS AREA AS REQUIRED BY ANY APPLICABLE AGENCY. GENERAL NOTES: TOWN OF PARADISE PUBLIC WORKS STANDARDS AND TOWN OF PARADISE STANDARD CULINARY WATER SYSTEM INSTALLATION DRAWINGS 1.TOWN OF PARADISE PUBLIC WORKS CONSTRUCTION STANDARDS. 2.STORM WATER SPECIFICATIONS ARE PER THE EPA NATIONAL MENU OF STORMWATER BEST MANAGEMENT PRACTICES UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) AND THE UTAH DEPARTMENT OF WATER QUALITY STORMWATER MANAGMENT PROGRAM. 3.THE SPECIFICATIONS MENTIONED IN ITEMS ONE AND TWO SHALL SUPERSEDE ANY CONFLICTING SPECIFICATIONS CONTAINED WITHIN THESE PLANS. 4.THE TOWN OF PARADISE STANDARDS CULINARY WATER SYSTEM INSTALLATION PLANS AND SPECIFICATIONS STANDARD SPECIFICATIONS: STANDARD DRAWINGS: PARADISE ENGINEERING DEPARTMENT APPROVAL: THE IMPROVEMENT FOR THIS SUBDIVISION HAVE BEEN REVIEWED BY THE TOWN ENGINEER FOR GENERAL CONFORMANCE WITH THE REQUIREMENTS OF THE TOWN SUBDIVISION ORDINANCE. THIS SET OF TOWN-APPROVED DRAWINGS SHALL BE USED FOR CONSTRUCTION OF THE REQUIRED SUBDIVISION IMPROVEMENTS. THE DEVELOPER'S ENGINEER, WHOSE STAMP IS ON THESE DRAWINGS, IS RESPONSIBLE FOR THE ENGINEERING DESIGN, DRAFTING, AND RELATED FIELD INFORMATION. THE CONSTRUCTION CONTRACTOR IS RESPONSIBLE FOR DIMENSIONS WHICH SHALL BE CONFIRMED AND CORRELATED AT THE JOB SITE; FABRICATION PROCESSES AND TECHNIQUES OF CONSTRUCTION; COORDINATION OF HIS OR HER WORK WITH THAT OF ALL OTHER TRADES; AND THE SATISFACTORY PERFORMANCES OF HIS OR HER WORK. BY:__________________________________________DATE:________________________ PROJECT CONTACTS: 1. DEVELOPER: BRETT PALMER BRETTPALMERPHF@YAHOO.COM P. 435.994.1064 2.CIVIL ENGINEER CIVIL SOLUTIONS GROUP MICHAEL TAYLOR 540 WEST GOLF COURSE ROAD SUITE B1 PROVIDENCE, UT 84332 P. 435.890.4498 E. MTAYOR@CIVILSOLUTIONSGROUP.NET 3.SURVEYOR CURTIS BOWN 540 WEST GOLF COURSE ROAD SUITE B1 PROVIDENCE, UT 84332 CBOWN@CSG.WORK P. 435.720.3761 4.TOWN PUBLIC WORKS DIRECTOR LEE ATWOOD 9035 S 100 W PARADISE, UT 84328 P. 435-245-6737 5. PARADISE FIRE DISTRICT 9035 S 100 W PARADISE, UT 84328 P. 435-245-6737 6. ROCKY MOUNTAIN POWER: JENNIFER PETERSEN P. 435.563.2921 7. UTAH STORM WATER PERMIT: UTAH DEPARTMENT OF WATER QUALITY P.O. BOX 144870 SALT LAKE CITY, UTAH 84114-4870 P. 801.538.6146 http://www.waterquality.utah.gov/UPDES/stormwater.htm 8. DOMINION ENERGY: CRISTI FIEDEL 895 WEST 800 NORTH LOGAN, UT 84321 P. 435.752.7751 PROPERTY BOUNDARY STORM DRAIN LINE WATER LINE IRRIGATION LINE GAS LINE SEWER LINE BURIED POWER LINE AERIAL POWER LINE COMMUNICATION LINE CONTOUR MINOR CONTOUR MAJOR ASPHALT OPEN FACE CURB AND GUTTER FENCE CONCRETE EXISTING TO BE REMOVED WATER VALVE FIRE HYDRANT STORMDRAIN BOX WATER METER SEWER MANHOLE sd ss c #### x x w e g e ir #### WATER LINE (SIZE SHOWN ON PLAN) STORM DRAIN LINE (SIZE SHOWN ON PLAN) IRRIGATION LINE (SIZE SHOWN ON PLAN) GAS LINE SANITARY SEWER LINE (SIZE SHOWN ON PLAN) BURIED POWER LINE BURIED COMMUNICATION LINE CONTOUR MAJOR CONTOUR MINOR ASPHALT OPEN FACE CURB AND GUTTER CLOSED FACE CURB AND GUTTER CONCRETE SIDEWALK. BUILDING SETBACK WATER VALVE FIRE HYDRANT SEWER MANHOLE WATER METER STORMDRAIN BOX STORM WATER CATCH BASIN IRR IRR C G W W E SS W S S W W W LEGEND EXISTING LEGEND PROPOSED SD #### #### Sheet List Table Sheet Number Sheet Title C001 INDEX C101 PLAN & PROFILE C102 PLAN & PROFILE C103 PLAN & PROFILE C201 DETAILS C202 DETAILS C203 DETAILS C204 DETAILS x x x x x x I C xxxxxxxxxxx II I II IIII III I III I I ir ir ir ir ir ir ir ir ir ir ir ir ir ir ir ir ir ir w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w wPARADISE TOWN CORP PARADISE CEMETERY PARCEL ID: 01-094-0020 LAURENCE R VEIKLEY PARCEL ID: 01-129-0004 D & J LLC PARCEL ID: 01-129-0005 D & J LLC PARCEL ID: 01-129-0006 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W W ir ir ir ir ir ir ir ir ir ir ir ir ir ir ir ir ir W 50 1 0 5 0 2 0 5 0 3 0 50 4 0 5 0 0 2 5 0 0 4 5 0 0 6 5 0 0 8 50 1 2 50 1 4 50 1 6 5 0 1 8 5 0 2 2 50 2 4 5 0 2 6 50 2 8 50 3 2 5 0 3 4 50 3 6 50 3 8 50 4 2 5040 5040 5042 5042 0+ 0 0 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 7+92 50 4 4 50 4 2 10 . 0 ' 8900 SOUTH PROFILE 4980 4985 4990 4995 5000 5005 5010 5015 5020 5025 5030 5035 5040 5045 5050 5055 5060 4980 4985 4990 4995 5000 5005 5010 5015 5020 5025 5030 5035 5040 5045 5050 5055 5060 0+00 25 50 75 1+00 25 50 75 2+00 25 50 75 3+00 25 50 75 4+00 25 50 75 5+00 25 50 75 6+00 25 50 75 7+00 25 50 75 8+00 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W W W N 0 30' 3/13/2024 DESIGNING OUR FUTURE C101 PLAN & PROFILE MA R K : DA T E : DE S C R I P T I O N : CA C H E V A L L E Y | P : 4 3 5 . 2 1 3 . 3 7 6 2 SA L T L A K E | P : 8 0 1 . 2 1 6 . 3 1 9 2 UT A H V A L L E Y | P : 8 0 1 . 8 7 4 . 1 4 3 2 in f o @ c i v i l s o l u t i o n s g r o u p . n e t ww w . c i v i l s o l u t i o n s g r o u p . n e t PA L M E R S U B D I V I S I O N 31 0 E A S T 8 9 0 0 N O R T H PA R A D I S E , U T 8 4 3 2 8 HATUFOETATS PR O F E S S I O NAL ENGI N E E R No. 8243188-2202 MICHAEL E. TAYLOR P: \ 2 0 2 1 \ 2 1 - 3 8 1 p a l m e r s u b d i v i s i o n - p a r a d i s e \ A u t o C A D \ C i v i l \ s h e e t s e t \ 2 1 - 3 8 1 P l a n & P r o f i l e THESE PLANS AND SPECIFICATIONS ARE THE PROPERTY OF CIVIL SOLUTIONS GROUP, INC. AND SHALL NOT BE PHOTOCOPIED, RE-DRAWN, OR USED ON ANY OTHER PROJECT OTHER THAN THE PROJECT SPECIFICALLY DESIGNED FOR, WITHOUT WRITTEN PERMISSION. THE OWNERS AND ENGINEERS OF CIVIL SOLUTIONS GROUP, INC. DISCLAIM ANY LIABILITY FOR ANY CHANGES OR MODIFICATIONS MADE TO THESE PLANS OR THE DESIGN THEREON WITHOUT THEIR CONSENT. THESE PLANS ARE DRAWN TO SCALE WHEN PLOTTED ON A 24" X 36" SHEET OF PAPER. THESE PLANS ARE PRODUCED IN COLOR AND SHOULD BE PLOTTED AS SUCH. PROJECT #: 21-381 DRAWN BY: L. MUMFORD PROJECT MANAGER: M. TAYLOR ISSUED:3/13/2024 60' 8900 SOUTH 20 0 E A S T MATCHLINE, SEE SHEET C102 1 2 8 9 2 9 61 1 10 14 759.0 LF 8" PVC PIPE GENERAL NOTES: 1.CONTRACTOR TO FIELD VERIFY ALL EXISTING UTILITY LOCATIONS AND CONTACT ENGINEER IF DIFFERENT FROM LOCATIONS DISPLAYED ON THESE PLANS. 2.MINIMUM OF 10' FROM OUTSIDE-OF-PIPE TO OUTSIDE-OF-PIPE REQUIRED BETWEEN CULINARY WATER LINE AND ALL OTHER WET UTILITIES. 3.ALL CULINARY WATER LINES SHALL BE INSTALLED PER UTILITY TRENCHING DETAIL FOUND IN STANDARD DRAWING 06 ON SHEET C-201. 4.ALL CULINARY WATER AND IRRIGATION LINES SHALL BE CLASS 200 PSI SDR 21 PVC PIPE CONFORMING TO ASTM D2241. ALL WATER MAINS AND SERVICES SHALL BE INSTALLED WITH A MINIMUM OF 5' OF COVER, AND IRRIGATION LINES WITH A MINIMUM OF 3' OF COVER. 5.ALL WATER SERVICES SHALL BE INSTALLED IN FRONT CENTER OF LOT UNLESS OTHERWISE NOTED. PROVIDE 11-FT HORIZONTAL SEPARATION BETWEEN CENTERLINES OF WATER & SEWER, 6-FT HORIZONTAL SEPARATION BETWEEN SECONDARY IRRIGATION AND SEWER. 6.ALL WATER SERVICES SHALL BE INSTALLED PER STANDARD DETAIL 2 ON SHEET C201. WATER SERVICES SHALL BE 3/4" CTS CLASS 200 PSI POLYETHYLENE WITH 24" "WHITE" BARRELS. THE TOWN WILL PROVIDE AND SET THE METERS. ALL OTHER PARTS (SERVICE LATERAL PIPING, SETTERS, BARRELS, ETC.) SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. PRIOR TO INSTALLATION OF BARRELS, LOCATIONS SHALL BE DETERMINED USING CONSTRUCTION STAKING METHODS. 7.CONTRACTOR SHALL PLACE CONCRETE THRUST BLOCKS ON ALL TEES, WYES, BENDS, ANGLES, ETC ON ALL WATER AND IRRIGATION LINES AS SHOWN IN DETAIL 7 ON SHEET C201. 8.DRIVEWAYS ACROSS SWALES MUST COMPLY WITH THE TOWN OF PARADISE PUBLIC WORKS STANDARD DRAWINGS. 9.ALL CULINARY WATER SYSTEM IMPROVEMENTS ARE TO COMPLY WITH THE TOWN OF PARADISE STANDARD CULINARY WATER SYSTEM INSTALLATION DRAWINGS & SPECIFICATIONS. 10.ANY BORING OF WATERLINES SHOULD BE DONE WITH BUTT-FUSED DR11 HDPE PIPE BY DIRECTIONAL BORING METHODS AND CONNECTED TO PVC PIPE WITH ROMAC ALPHA STYLE RESTRAINED CONNECTORS. BOOSTER PUMP GENERAL NOTES: 1.BOOSTER PUMP STATION BE FURNISHED WITH TWO SEPARATE PUMPS: A SMALL PUMP FOR EVERY-DAY USE FOR MAINTAINING PRESSURE AND DEMAND FOR NORMAL RESIDENTIAL INDOOR USE AT A PRESSURE OF 70- 80 PSI. A LARGER PUMP WILL FURNISH THE ADDITIONAL 500 GPM FOR FIRE SUPPRESSION. THIS PUMP WILL START UP WHEN THE PRESSURE IN THE NEW 8” LINE DROPS TO A TARGET PRESSURE OF 45 PSI AT THE PUMP STATION AND MAINTAINS THIS PRESSURE DURING A FIRE SUPPRESSION EVENT. BOTH PUMPS SHOULD HAVE VARIABLE DISCHARGE OUTPUTS TO MAINTAIN PRESSURES DURING VARIABLE DEMANDS. OTHER CONFIGURATIONS MAY BE CONSIDERED AND PROPOSED BY THE DEVELOPER FOR REVIEW BY PARADISE AND THE UTAH DIVISION OF DRINKING WATER. 2.THE CALCULATED PRESSURE AT THE CONNECTION OF THE BOOSTER PUMP STATION TO THE EXISTING TOWN WATERLINE DURING A 500 GPM FIRE FLOW IN THE NEW FIRE HYDRANT AND RESIDENTIAL DEMAND IS ABOUT 45.5 PSI. THE FIRE FLOW BOOSTER PUMP WILL NEED TO OVERCOME FRICTION LOSS AND ELEVATION GAIN TO FURNISH THE REQUIRED FLOW AT A MINIMUM OF 35 PSI AT THE HIGHEST ELEVATION OF THE SOUTH PROPOSED LOT. 3.THE CALCULATED PRESSURE AT THE CONNECTION OF THE BOOSTER PUMP STATION TO THE EXISTING TOWN WATERLINE DURING PEAK INSTANTANEOUS DEMAND WITHOUT A FIRE FLOW EVENT IS APPROXIMATELY 35.7 PSI. THE SMALLER PUMP SHOULD BE CAPABLE OF PRODUCING AT LEAST 70 PSI (PREFERABLY 80 PSI) AT THE HIGHEST LOT DURING PEAK RESIDENTIAL DEMAND OF THE 3 LOTS. THERE IS A RISE OF APPROXIMATELY 35 FEET BETWEEN THE BOOSTER PUMP STATION LOCATION AND THE CENTER OF THE SOUTH LOT OF THE PROPOSED SUBDIVISION. 4.BOOSTER PUMP SHALL BE HOUSED IN A CMU STRUCTURE. SEE STRUCTURAL PLANS AND CIVIL DETAILS FOR MORE INFORMATION. THE BOOSTER PUMP SHALL BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS. 5.CONSIDERATION IS NEEDED TO ADJUST THE RESIDUAL INLET PRESSURE AT THE PUMPS AND ASSOCIATED PUMP CAPACITY AND RESIDUAL INLET PRESSURES. WHEN BOOSTER PUMPS ARE OPERATING, THE DIVISION OF DRINKING WATER REQUIRES THAT A MINIMUM OF 25 PSI BE MAINTAINED AT THE INLET. 1 SITE SHEET KEY NOTES: PROVIDE, INSTALL, AND/OR CONSTRUCT THE FOLLOWING PER THE SPECIFICATIONS GIVEN OR REFERENCED, THE DETAILS NOTED, AND/OR AS SHOWN ON THE CONSTRUCTION DRAWINGS: 1.PROPOSED 8" CULINARY WATER LINE 2.EXISTING 8" CULINARY WATER LINE 3.INSTALL 8"x90° MJ BEND. 4.FIRE HYDRANT ASSEMBLY & GATE VALVE (1/C201) 5.INSTALL 3/4" WATER METER & SERVICE, TYP. (2/C201) 6.PROPOSED BOOSTER PUMP STATION (LOT OWNERS BENEFITING FROM BOOSTER PUMP STATION ARE RESPONSIBLE FOR ALL COSTS INCLUDING MAINTENANCE AND OPERATING COSTS). REFER TO BOOSTER PUMP GENERAL NOTES. SEE SHEET C202 FOR MORE INFORMATION. 7.AP4 HIGH POLYMER SURFACE TREATMENT OR CHIP SEAL WITH FLUSH COAT EXISTING ROADWAY WITHIN SUBDIVISION BOUNDARY. (ENTIRETY OF 8900 S & 300 E, SOUTH HALF OF 8800 S) 8.8" TAPPING SLEEVE TEE WITH VALVE ASSEMBLY (5/C201). CONTRACTOR SHALL CONFIRM THE SIZE OF PIPE, LOCATION AND ELEVATIONS PRIOR TO ELEVATIONS. 9.EXISTING 8" CULINARY WATER LINE 10.ABANDONED EXISTING 4" CULINARY WATER LINE 11.GATE VALVE. 12.EXISTING DRAINAGE CHANNEL (PROTECT IN PLACE) 13.EXISTING DRAINAGE PIPE (PROTECT IN PLACE) 14.EXISTING 2 1/2" CULINARY WATER LINE 15.PIPE SECTION TO BE BORED UNDER ROAD DIRECTIONAL BORING METHODS USING DR11 HDPE BUTT-FUSED WELDED BY AND CONNECTED TO THE PVC PIPE ON EACH SIDE WITH ROMAC ALPHA RESTRAINED COUPLER FOR ADAPTING DR11 HDPE AND CLASS 200 PSI DR 21 PVC PIPE TO EACH OTHER. 16.EXISTING POWER LINE 17.EXISTING GAS LINE 18.EXISTING COMMUNICATION LINE 19.INSTALL 8"x6" FLANGED TEE. INSTALL 8"x4" REDUCER NORTH OF THE TEE. 20.DRAIN VALVE WITH STOP & WASTE VAULT WITH GRAVEL BOTTOM 21.3" SCHEDULE 40 PVC TRENCH (6/C201) 22.INSTALL 3" IRRIGATION METER (1/C204) 23.INSTALL 3" GATE VALVE 24.INSTALL IRRIGATION SERVICE (4/C201) 25.CAP & MARK END OF LINE 26.DRAIN VALVE WITH STOP & WASTE VAULT WITH GRAVEL BOTTOM SEWER NARRATIVE: ALL LOTS WILL HAVE THEIR OWN SEPTIC DRAIN FIELD. DESIGN TO BE DONE BY OTHERS. PERMITS FROM BEAR RIVER HEALTH DEPARTMENT PENDING. STORMWATER NARRATIVE: THE EXISTING STORM WATER SWALES AND CONVEYANCE STRUCTURES HAVE ALREADY BEEN CONSTRUCTED ACCORDING TO TOWN STANDARDS. NO IMPROVEMENTS TO STORM DRAIN SYSTEM ARE BEING PROPOSED. 7.0' 7.0' 9.0' EXISTING GRADE 5.0' MIN BURY 1 8 6 PROFILE SCALE: 1" = 30' VERTICAL EXAGGERATION: 2X 6 11 11 3.2' gggggggggggg g g g g e e e e e e e e e e e e T c c c c c c c c c c c c c c E E x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 15 S D I x I ir ir w w w w w w w w w w w SKYLARK FOUNDATION SUBDIVISION LOT #10 PA R A D I S E T O W N C O R P PA R A D I S E C E M E T E R Y PA R C E L I D : 0 1 - 0 9 4 - 0 0 2 0 D & J LLC PARCEL ID: 01-129-0006 SHAD & MELINDA SWANSON PARCEL ID: 01-129-0007 e e 8W 8W 8W 8W 8W 8W 8W 4W 4W 4W 4W 4W 4W 4W LO T 3 Ar e a : 6 9 7 3 2 S F 1. 6 0 A C 8W 8W W W W W W ir ir ir ir ir ir ir W LO T 1 Ar e a : 6 8 3 7 9 S F 1. 5 7 A C LO T 2 Ar e a : 6 8 7 9 5 S F 1. 5 8 A C 5040 5038 5042 50405040 5040 50 4 0 5 0 4 0 503 4 503 6 5038 5042 50 4 2 5 0 4 2 50 4 2 5 0 4 2 0+00 1+00 2+00 3+00 4+00 5+00 6+00 6+37 7+ 0 0 7+ 9 2 504 8 504 6 504 4 5042 5040 503 8 503 6 503 4 5 0 3 2 5030 5032 5034 503 6 5038 5040 502 8 5026 5024 5' MIN. OFF OF EDGE EXISTING PAVEMENT 300 EAST PROFILE 5010 5015 5020 5025 5030 5035 5040 5045 5050 5055 5060 5010 5015 5020 5025 5030 5035 5040 5045 5050 5055 5060 -0+25 0+00 25 50 75 1+00 25 50 75 2+00 25 50 75 3+00 25 50 75 4+00 25 50 75 5+00 25 50 75 6+00 25 50 75 7+00 7+25 8W 8W 8W 8W 8W 8W 4W 4W 4W 4W 4W 4W 3/13/2024 DESIGNING OUR FUTURE C102 PLAN & PROFILE MA R K : DA T E : DE S C R I P T I O N : CA C H E V A L L E Y | P : 4 3 5 . 2 1 3 . 3 7 6 2 SA L T L A K E | P : 8 0 1 . 2 1 6 . 3 1 9 2 UT A H V A L L E Y | P : 8 0 1 . 8 7 4 . 1 4 3 2 in f o @ c i v i l s o l u t i o n s g r o u p . n e t ww w . c i v i l s o l u t i o n s g r o u p . n e t PA L M E R S U B D I V I S I O N 31 0 E A S T 8 9 0 0 N O R T H PA R A D I S E , U T 8 4 3 2 8 HATUFOETATS PR O F E S S I O NAL ENGI N E E R No. 8243188-2202 MICHAEL E. TAYLOR P: \ 2 0 2 1 \ 2 1 - 3 8 1 p a l m e r s u b d i v i s i o n - p a r a d i s e \ A u t o C A D \ C i v i l \ s h e e t s e t \ 2 1 - 3 8 1 P l a n & P r o f i l e THESE PLANS AND SPECIFICATIONS ARE THE PROPERTY OF CIVIL SOLUTIONS GROUP, INC. AND SHALL NOT BE PHOTOCOPIED, RE-DRAWN, OR USED ON ANY OTHER PROJECT OTHER THAN THE PROJECT SPECIFICALLY DESIGNED FOR, WITHOUT WRITTEN PERMISSION. THE OWNERS AND ENGINEERS OF CIVIL SOLUTIONS GROUP, INC. DISCLAIM ANY LIABILITY FOR ANY CHANGES OR MODIFICATIONS MADE TO THESE PLANS OR THE DESIGN THEREON WITHOUT THEIR CONSENT. THESE PLANS ARE DRAWN TO SCALE WHEN PLOTTED ON A 24" X 36" SHEET OF PAPER. THESE PLANS ARE PRODUCED IN COLOR AND SHOULD BE PLOTTED AS SUCH. PROJECT #: 21-381 DRAWN BY: L. MUMFORD PROJECT MANAGER: M. TAYLOR ISSUED:3/13/2024 89 0 0 S O U T H 300 EAST MATCHLINE, SEE SHEET C101 7 3 10 14 1 5 5 5 15 12 12 12 12 12 4 25 13 13 13 13 88 0 0 S O U T H 312 LF 4" PVC PIPE 1 GENERAL NOTES: 1.CONTRACTOR TO FIELD VERIFY ALL EXISTING UTILITY LOCATIONS AND CONTACT ENGINEER IF DIFFERENT FROM LOCATIONS DISPLAYED ON THESE PLANS. 2.MINIMUM OF 10' FROM OUTSIDE-OF-PIPE TO OUTSIDE-OF-PIPE REQUIRED BETWEEN CULINARY WATER LINE AND ALL OTHER WET UTILITIES. 3.ALL CULINARY WATER LINES SHALL BE INSTALLED PER UTILITY TRENCHING DETAIL FOUND IN STANDARD DRAWING 06 ON SHEET C-201. 4.ALL CULINARY WATER AND IRRIGATION LINES SHALL BE CLASS 200 PSI SDR 21 PVC PIPE CONFORMING TO ASTM D2241. ALL WATER MAINS AND SERVICES SHALL BE INSTALLED WITH A MINIMUM OF 5' OF COVER, AND IRRIGATION LINES WITH A MINIMUM OF 3' OF COVER. 5.ALL WATER SERVICES SHALL BE INSTALLED IN FRONT CENTER OF LOT UNLESS OTHERWISE NOTED. PROVIDE 11-FT HORIZONTAL SEPARATION BETWEEN CENTERLINES OF WATER & SEWER, 6-FT HORIZONTAL SEPARATION BETWEEN SECONDARY IRRIGATION AND SEWER. 6.ALL WATER SERVICES SHALL BE INSTALLED PER STANDARD DETAIL 2 ON SHEET C201. WATER SERVICES SHALL BE 3/4" CTS CLASS 200 PSI POLYETHYLENE WITH 24" "WHITE" BARRELS. THE TOWN WILL PROVIDE AND SET THE METERS. ALL OTHER PARTS (SERVICE LATERAL PIPING, SETTERS, BARRELS, ETC.) SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. PRIOR TO INSTALLATION OF BARRELS, LOCATIONS SHALL BE DETERMINED USING CONSTRUCTION STAKING METHODS. 7.CONTRACTOR SHALL PLACE CONCRETE THRUST BLOCKS ON ALL TEES, WYES, BENDS, ANGLES, ETC ON ALL WATER AND IRRIGATION LINES AS SHOWN IN DETAIL 7 ON SHEET C201. 8.DRIVEWAYS ACROSS SWALES MUST COMPLY WITH THE TOWN OF PARADISE PUBLIC WORKS STANDARD DRAWINGS. 9.ALL CULINARY WATER SYSTEM IMPROVEMENTS ARE TO COMPLY WITH THE TOWN OF PARADISE STANDARD CULINARY WATER SYSTEM INSTALLATION DRAWINGS & SPECIFICATIONS. 10.ANY BORING OF WATERLINES SHOULD BE DONE WITH BUTT-FUSED DR11 HDPE PIPE BY DIRECTIONAL BORING METHODS AND CONNECTED TO PVC PIPE WITH ROMAC ALPHA STYLE RESTRAINED CONNECTORS. BOOSTER PUMP GENERAL NOTES: 1.BOOSTER PUMP STATION BE FURNISHED WITH TWO SEPARATE PUMPS: A SMALL PUMP FOR EVERY-DAY USE FOR MAINTAINING PRESSURE AND DEMAND FOR NORMAL RESIDENTIAL INDOOR USE AT A PRESSURE OF 70- 80 PSI. A LARGER PUMP WILL FURNISH THE ADDITIONAL 500 GPM FOR FIRE SUPPRESSION. THIS PUMP WILL START UP WHEN THE PRESSURE IN THE NEW 8” LINE DROPS TO A TARGET PRESSURE OF 45 PSI AT THE PUMP STATION AND MAINTAINS THIS PRESSURE DURING A FIRE SUPPRESSION EVENT. BOTH PUMPS SHOULD HAVE VARIABLE DISCHARGE OUTPUTS TO MAINTAIN PRESSURES DURING VARIABLE DEMANDS. OTHER CONFIGURATIONS MAY BE CONSIDERED AND PROPOSED BY THE DEVELOPER FOR REVIEW BY PARADISE AND THE UTAH DIVISION OF DRINKING WATER. 2.THE CALCULATED PRESSURE AT THE CONNECTION OF THE BOOSTER PUMP STATION TO THE EXISTING TOWN WATERLINE DURING A 500 GPM FIRE FLOW IN THE NEW FIRE HYDRANT AND RESIDENTIAL DEMAND IS ABOUT 45.5 PSI. THE FIRE FLOW BOOSTER PUMP WILL NEED TO OVERCOME FRICTION LOSS AND ELEVATION GAIN TO FURNISH THE REQUIRED FLOW AT A MINIMUM OF 35 PSI AT THE HIGHEST ELEVATION OF THE SOUTH PROPOSED LOT. 3.THE CALCULATED PRESSURE AT THE CONNECTION OF THE BOOSTER PUMP STATION TO THE EXISTING TOWN WATERLINE DURING PEAK INSTANTANEOUS DEMAND WITHOUT A FIRE FLOW EVENT IS APPROXIMATELY 35.7 PSI. THE SMALLER PUMP SHOULD BE CAPABLE OF PRODUCING AT LEAST 70 PSI (PREFERABLY 80 PSI) AT THE HIGHEST LOT DURING PEAK RESIDENTIAL DEMAND OF THE 3 LOTS. THERE IS A RISE OF APPROXIMATELY 35 FEET BETWEEN THE BOOSTER PUMP STATION LOCATION AND THE CENTER OF THE SOUTH LOT OF THE PROPOSED SUBDIVISION. 4.BOOSTER PUMP SHALL BE HOUSED IN A CMU STRUCTURE. SEE STRUCTURAL PLANS AND CIVIL DETAILS FOR MORE INFORMATION. THE BOOSTER PUMP SHALL BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS. 5.CONSIDERATION IS NEEDED TO ADJUST THE RESIDUAL INLET PRESSURE AT THE PUMPS AND ASSOCIATED PUMP CAPACITY AND RESIDUAL INLET PRESSURES. WHEN BOOSTER PUMPS ARE OPERATING, THE DIVISION OF DRINKING WATER REQUIRES THAT A MINIMUM OF 25 PSI BE MAINTAINED AT THE INLET. 1 SITE SHEET KEY NOTES: PROVIDE, INSTALL, AND/OR CONSTRUCT THE FOLLOWING PER THE SPECIFICATIONS GIVEN OR REFERENCED, THE DETAILS NOTED, AND/OR AS SHOWN ON THE CONSTRUCTION DRAWINGS: 1.PROPOSED 8" CULINARY WATER LINE 2.EXISTING 8" CULINARY WATER LINE 3.INSTALL 8"x90° MJ BEND. 4.FIRE HYDRANT ASSEMBLY & GATE VALVE (1/C201) 5.INSTALL 3/4" WATER METER & SERVICE, TYP. (2/C201) 6.PROPOSED BOOSTER PUMP STATION (LOT OWNERS BENEFITING FROM BOOSTER PUMP STATION ARE RESPONSIBLE FOR ALL COSTS INCLUDING MAINTENANCE AND OPERATING COSTS). REFER TO BOOSTER PUMP GENERAL NOTES. SEE SHEET C202 FOR MORE INFORMATION. 7.AP4 HIGH POLYMER SURFACE TREATMENT OR CHIP SEAL WITH FLUSH COAT EXISTING ROADWAY WITHIN SUBDIVISION BOUNDARY. (ENTIRETY OF 8900 S & 300 E, SOUTH HALF OF 8800 S) 8.8" TAPPING SLEEVE TEE WITH VALVE ASSEMBLY (5/C201). CONTRACTOR SHALL CONFIRM THE SIZE OF PIPE, LOCATION AND ELEVATIONS PRIOR TO ELEVATIONS. 9.EXISTING 8" CULINARY WATER LINE 10.ABANDONED EXISTING 4" CULINARY WATER LINE 11.GATE VALVE. 12.EXISTING DRAINAGE CHANNEL (PROTECT IN PLACE) 13.EXISTING DRAINAGE PIPE (PROTECT IN PLACE) 14.EXISTING 2 1/2" CULINARY WATER LINE 15.PIPE SECTION TO BE BORED UNDER ROAD DIRECTIONAL BORING METHODS USING DR11 HDPE BUTT-FUSED WELDED BY AND CONNECTED TO THE PVC PIPE ON EACH SIDE WITH ROMAC ALPHA RESTRAINED COUPLER FOR ADAPTING DR11 HDPE AND CLASS 200 PSI DR 21 PVC PIPE TO EACH OTHER. 16.EXISTING POWER LINE 17.EXISTING GAS LINE 18.EXISTING COMMUNICATION LINE 19.INSTALL 8"x6" FLANGED TEE. INSTALL 8"x4" REDUCER NORTH OF THE TEE. 20.DRAIN VALVE WITH STOP & WASTE VAULT WITH GRAVEL BOTTOM 21.3" SCHEDULE 40 PVC TRENCH (6/C201) 22.INSTALL 3" IRRIGATION METER (1/C204) 23.INSTALL 3" GATE VALVE 24.INSTALL IRRIGATION SERVICE (4/C201) 25.CAP & MARK END OF LINE 26.DRAIN VALVE WITH STOP & WASTE VAULT WITH GRAVEL BOTTOM SEWER NARRATIVE: ALL LOTS WILL HAVE THEIR OWN SEPTIC DRAIN FIELD. DESIGN TO BE DONE BY OTHERS. PERMITS FROM BEAR RIVER HEALTH DEPARTMENT PENDING. STORMWATER NARRATIVE: THE EXISTING STORM WATER SWALES AND CONVEYANCE STRUCTURES HAVE ALREADY BEEN CONSTRUCTED ACCORDING TO TOWN STANDARDS. NO IMPROVEMENTS TO STORM DRAIN SYSTEM ARE BEING PROPOSED. N 0 30'60' FILL OVER CULVERT AT WATERLINE CROSSING. ENSURE 5.0' OF COVER THROUGH SWALE CROSSING 5.0' MIN BURY 1 7 7 7 16 18 17 5.0' MIN 4 3 11 19 28 L F 6 " PV C P I P E 291 LF 8" PVC PIPE EX SD BOX RIM: 5038.87' N INV (15"): 5036.53' EX SD BOX RIM: 5035.27' N INV (15"): 5032.97'EX SD BOX RIM: 5029.37' N INV (15"): 5027.38' EX SD BOX RIM: 5045.44' N INV (15"): 5043.10' EX SD BOX RIM: 5038.08' N INV (15"): 5035.77' EX SD BOX RIM: 5034.24' N INV (15"): 5032.15' PROFILE SCALE: 1" = 30' VERTICAL EXAGGERATION: 2X REROUTE EXISTING UTILITIES AROUND WATER METERS AS NEEDED (TYP) 6 19 25 PROVIDE 10 L.F. OF 15" ADS N-12 HDPE CULVERT WITH END SECTIONS WHERE HYDRANT LATERAL PASSES THROUGH SWALE ENSURE A MINIMUM OF 1' OF COVER OVER THE TOP OF PIPE. PROVIDE 42 L.F. OF 15" ADS N-12 HDPE CULVERT WITH END SECTIONS WHERE WATERLINE PASSES THROUGH SWALE ENSURE A MINIMUM OF 1' OF COVER OVER THE TOP OF PIPE. PROVIDE 42 L.F. OF 15" ADS N-12 HDPE CULVERT WITH END SECTIONS WHERE WATERLINE PASSES THROUGH SWALE 9 INSTALL NEW SURVEY MONUMENT INSTALL NEW SURVEY MONUMENT NEW COMBO STOP SIGN/ STREET SIGN NEW STREET SIGN W1-6 48"x24" ONE DIRECTION SIGNS PER M.U.T.C.D. STANDARDS STREET LIGHT PER TOWN OF PARADISE STANDARDS STREET LIGHT PER TOWN OF PARADISE STANDARDS EXISTING RMP ELECTRICAL SECTIONALIZER g g e e e e c c c c x x x x x x x 12 S D w w w w w TO W N O F P A R A D I S E 01 - 0 9 3 - 0 0 2 3 LO T 3 Ar e a : 6 9 7 3 2 S F 1. 6 0 A C W W ir ir ir ir ir 3IRR 3IRR 3I R R 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR LO T 1 Ar e a : 6 8 3 7 9 S F 1. 5 7 A C LO T 2 Ar e a : 6 8 7 9 5 S F 1. 5 8 A C 0+00 1+ 0 0 2+00 3+00 4+00 5+00 5+75 504 8 5040 IRRIGAITON PROFILE 5020 5025 5030 5035 5040 5045 5050 5055 5060 5065 5070 5075 5080 5020 5025 5030 5035 5040 5045 5050 5055 5060 5065 5070 5075 5080 0+00 25 50 75 1+00 25 50 75 2+00 25 50 75 3+00 25 50 75 4+00 25 50 75 5+00 25 50 75 6+00 6+25 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR 3IRR I 3/13/2024 DESIGNING OUR FUTURE C103 PLAN & PROFILE MA R K : DA T E : DE S C R I P T I O N : CA C H E V A L L E Y | P : 4 3 5 . 2 1 3 . 3 7 6 2 SA L T L A K E | P : 8 0 1 . 2 1 6 . 3 1 9 2 UT A H V A L L E Y | P : 8 0 1 . 8 7 4 . 1 4 3 2 in f o @ c i v i l s o l u t i o n s g r o u p . n e t ww w . c i v i l s o l u t i o n s g r o u p . n e t PA L M E R S U B D I V I S I O N 31 0 E A S T 8 9 0 0 N O R T H PA R A D I S E , U T 8 4 3 2 8 HATUFOETATS PR O F E S S I O NAL ENGI N E E R No. 8243188-2202 MICHAEL E. TAYLOR P: \ 2 0 2 1 \ 2 1 - 3 8 1 p a l m e r s u b d i v i s i o n - p a r a d i s e \ A u t o C A D \ C i v i l \ s h e e t s e t \ 2 1 - 3 8 1 P l a n & P r o f i l e THESE PLANS AND SPECIFICATIONS ARE THE PROPERTY OF CIVIL SOLUTIONS GROUP, INC. AND SHALL NOT BE PHOTOCOPIED, RE-DRAWN, OR USED ON ANY OTHER PROJECT OTHER THAN THE PROJECT SPECIFICALLY DESIGNED FOR, WITHOUT WRITTEN PERMISSION. THE OWNERS AND ENGINEERS OF CIVIL SOLUTIONS GROUP, INC. DISCLAIM ANY LIABILITY FOR ANY CHANGES OR MODIFICATIONS MADE TO THESE PLANS OR THE DESIGN THEREON WITHOUT THEIR CONSENT. THESE PLANS ARE DRAWN TO SCALE WHEN PLOTTED ON A 24" X 36" SHEET OF PAPER. THESE PLANS ARE PRODUCED IN COLOR AND SHOULD BE PLOTTED AS SUCH. PROJECT #: 21-381 DRAWN BY: L. MUMFORD PROJECT MANAGER: M. TAYLOR ISSUED:3/13/2024 N 0 30'60' 89 0 0 S O U T H 88 0 0 S O U T H 22 23 15 CONNECT TO EXISTING IRRIGATION LINE (EX. STUB SIZE AND DEPTH UNKNOWN) 24 24 24 GENERAL NOTES: 1.CONTRACTOR TO FIELD VERIFY ALL EXISTING UTILITY LOCATIONS AND CONTACT ENGINEER IF DIFFERENT FROM LOCATIONS DISPLAYED ON THESE PLANS. 2.MINIMUM OF 10' FROM OUTSIDE-OF-PIPE TO OUTSIDE-OF-PIPE REQUIRED BETWEEN CULINARY WATER LINE AND ALL OTHER WET UTILITIES. 3.ALL CULINARY WATER LINES SHALL BE INSTALLED PER UTILITY TRENCHING DETAIL FOUND IN STANDARD DRAWING 06 ON SHEET C-201. 4.ALL CULINARY WATER AND IRRIGATION LINES SHALL BE CLASS 200 PSI SDR 21 PVC PIPE CONFORMING TO ASTM D2241. ALL WATER MAINS AND SERVICES SHALL BE INSTALLED WITH A MINIMUM OF 5' OF COVER, AND IRRIGATION LINES WITH A MINIMUM OF 3' OF COVER. 5.ALL WATER SERVICES SHALL BE INSTALLED IN FRONT CENTER OF LOT UNLESS OTHERWISE NOTED. PROVIDE 11-FT HORIZONTAL SEPARATION BETWEEN CENTERLINES OF WATER & SEWER, 6-FT HORIZONTAL SEPARATION BETWEEN SECONDARY IRRIGATION AND SEWER. 6.ALL WATER SERVICES SHALL BE INSTALLED PER STANDARD DETAIL 2 ON SHEET C201. WATER SERVICES SHALL BE 3/4" CTS CLASS 200 PSI POLYETHYLENE WITH 24" "WHITE" BARRELS. THE TOWN WILL PROVIDE AND SET THE METERS. ALL OTHER PARTS (SERVICE LATERAL PIPING, SETTERS, BARRELS, ETC.) SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. PRIOR TO INSTALLATION OF BARRELS, LOCATIONS SHALL BE DETERMINED USING CONSTRUCTION STAKING METHODS. 7.CONTRACTOR SHALL PLACE CONCRETE THRUST BLOCKS ON ALL TEES, WYES, BENDS, ANGLES, ETC ON ALL WATER AND IRRIGATION LINES AS SHOWN IN DETAIL 7 ON SHEET C201. 8.DRIVEWAYS ACROSS SWALES MUST COMPLY WITH THE TOWN OF PARADISE PUBLIC WORKS STANDARD DRAWINGS. 9.ALL CULINARY WATER SYSTEM IMPROVEMENTS ARE TO COMPLY WITH THE TOWN OF PARADISE STANDARD CULINARY WATER SYSTEM INSTALLATION DRAWINGS & SPECIFICATIONS. 10.ANY BORING OF WATERLINES SHOULD BE DONE WITH BUTT-FUSED DR11 HDPE PIPE BY DIRECTIONAL BORING METHODS AND CONNECTED TO PVC PIPE WITH ROMAC ALPHA STYLE RESTRAINED CONNECTORS. BOOSTER PUMP GENERAL NOTES: 1.BOOSTER PUMP STATION BE FURNISHED WITH TWO SEPARATE PUMPS: A SMALL PUMP FOR EVERY-DAY USE FOR MAINTAINING PRESSURE AND DEMAND FOR NORMAL RESIDENTIAL INDOOR USE AT A PRESSURE OF 70- 80 PSI. A LARGER PUMP WILL FURNISH THE ADDITIONAL 500 GPM FOR FIRE SUPPRESSION. THIS PUMP WILL START UP WHEN THE PRESSURE IN THE NEW 8” LINE DROPS TO A TARGET PRESSURE OF 45 PSI AT THE PUMP STATION AND MAINTAINS THIS PRESSURE DURING A FIRE SUPPRESSION EVENT. BOTH PUMPS SHOULD HAVE VARIABLE DISCHARGE OUTPUTS TO MAINTAIN PRESSURES DURING VARIABLE DEMANDS. OTHER CONFIGURATIONS MAY BE CONSIDERED AND PROPOSED BY THE DEVELOPER FOR REVIEW BY PARADISE AND THE UTAH DIVISION OF DRINKING WATER. 2.THE CALCULATED PRESSURE AT THE CONNECTION OF THE BOOSTER PUMP STATION TO THE EXISTING TOWN WATERLINE DURING A 500 GPM FIRE FLOW IN THE NEW FIRE HYDRANT AND RESIDENTIAL DEMAND IS ABOUT 45.5 PSI. THE FIRE FLOW BOOSTER PUMP WILL NEED TO OVERCOME FRICTION LOSS AND ELEVATION GAIN TO FURNISH THE REQUIRED FLOW AT A MINIMUM OF 35 PSI AT THE HIGHEST ELEVATION OF THE SOUTH PROPOSED LOT. 3.THE CALCULATED PRESSURE AT THE CONNECTION OF THE BOOSTER PUMP STATION TO THE EXISTING TOWN WATERLINE DURING PEAK INSTANTANEOUS DEMAND WITHOUT A FIRE FLOW EVENT IS APPROXIMATELY 35.7 PSI. THE SMALLER PUMP SHOULD BE CAPABLE OF PRODUCING AT LEAST 70 PSI (PREFERABLY 80 PSI) AT THE HIGHEST LOT DURING PEAK RESIDENTIAL DEMAND OF THE 3 LOTS. THERE IS A RISE OF APPROXIMATELY 35 FEET BETWEEN THE BOOSTER PUMP STATION LOCATION AND THE CENTER OF THE SOUTH LOT OF THE PROPOSED SUBDIVISION. 4.BOOSTER PUMP SHALL BE HOUSED IN A CMU STRUCTURE. SEE STRUCTURAL PLANS AND CIVIL DETAILS FOR MORE INFORMATION. THE BOOSTER PUMP SHALL BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS. 5.CONSIDERATION IS NEEDED TO ADJUST THE RESIDUAL INLET PRESSURE AT THE PUMPS AND ASSOCIATED PUMP CAPACITY AND RESIDUAL INLET PRESSURES. WHEN BOOSTER PUMPS ARE OPERATING, THE DIVISION OF DRINKING WATER REQUIRES THAT A MINIMUM OF 25 PSI BE MAINTAINED AT THE INLET. 1 SITE SHEET KEY NOTES: PROVIDE, INSTALL, AND/OR CONSTRUCT THE FOLLOWING PER THE SPECIFICATIONS GIVEN OR REFERENCED, THE DETAILS NOTED, AND/OR AS SHOWN ON THE CONSTRUCTION DRAWINGS: 1.PROPOSED 8" CULINARY WATER LINE 2.EXISTING 8" CULINARY WATER LINE 3.INSTALL 8"x90° MJ BEND. 4.FIRE HYDRANT ASSEMBLY & GATE VALVE (1/C201) 5.INSTALL 3/4" WATER METER & SERVICE, TYP. (2/C201) 6.PROPOSED BOOSTER PUMP STATION (LOT OWNERS BENEFITING FROM BOOSTER PUMP STATION ARE RESPONSIBLE FOR ALL COSTS INCLUDING MAINTENANCE AND OPERATING COSTS). REFER TO BOOSTER PUMP GENERAL NOTES. SEE SHEET C202 FOR MORE INFORMATION. 7.AP4 HIGH POLYMER SURFACE TREATMENT OR CHIP SEAL WITH FLUSH COAT EXISTING ROADWAY WITHIN SUBDIVISION BOUNDARY. (ENTIRETY OF 8900 S & 300 E, SOUTH HALF OF 8800 S) 8.8" TAPPING SLEEVE TEE WITH VALVE ASSEMBLY (5/C201). CONTRACTOR SHALL CONFIRM THE SIZE OF PIPE, LOCATION AND ELEVATIONS PRIOR TO ELEVATIONS. 9.EXISTING 8" CULINARY WATER LINE 10.ABANDONED EXISTING 4" CULINARY WATER LINE 11.GATE VALVE. 12.EXISTING DRAINAGE CHANNEL (PROTECT IN PLACE) 13.EXISTING DRAINAGE PIPE (PROTECT IN PLACE) 14.EXISTING 2 1/2" CULINARY WATER LINE 15.PIPE SECTION TO BE BORED UNDER ROAD DIRECTIONAL BORING METHODS USING DR11 HDPE BUTT-FUSED WELDED BY AND CONNECTED TO THE PVC PIPE ON EACH SIDE WITH ROMAC ALPHA RESTRAINED COUPLER FOR ADAPTING DR11 HDPE AND CLASS 200 PSI DR 21 PVC PIPE TO EACH OTHER. 16.EXISTING POWER LINE 17.EXISTING GAS LINE 18.EXISTING COMMUNICATION LINE 19.INSTALL 8"x6" FLANGED TEE. INSTALL 8"x4" REDUCER NORTH OF THE TEE. 20.DRAIN VALVE WITH STOP & WASTE VAULT WITH GRAVEL BOTTOM 21.3" SCHEDULE 40 PVC TRENCH (6/C201) 22.INSTALL 3" IRRIGATION METER (1/C204) 23.INSTALL 3" GATE VALVE 24.INSTALL IRRIGATION SERVICE (4/C201) 25.CAP & MARK END OF LINE 26.DRAIN VALVE WITH STOP & WASTE VAULT WITH GRAVEL BOTTOM SEWER NARRATIVE: ALL LOTS WILL HAVE THEIR OWN SEPTIC DRAIN FIELD. DESIGN TO BE DONE BY OTHERS. PERMITS FROM BEAR RIVER HEALTH DEPARTMENT PENDING. STORMWATER NARRATIVE: THE EXISTING STORM WATER SWALES AND CONVEYANCE STRUCTURES HAVE ALREADY BEEN CONSTRUCTED ACCORDING TO TOWN STANDARDS. NO IMPROVEMENTS TO STORM DRAIN SYSTEM ARE BEING PROPOSED. 21 21 21 22 23 EXISTING GRADE CONNECT TO EXISTING IRRIGATION LINE (EX. STUB SIZE AND DEPTH UNKNOWN) 3" PVC PIPE @ -0.25% (FOR DRAINAGE TO STOP & WASTE PIT) 26 26 PROFILE SCALE: 1" = 30' VERTICAL EXAGGERATION: 2X 3' MIN. BURY DEPTH 1 C201 FIRE HYDRANT ASSEMBLY & GATE VALVE NOT TO SCALE 3/13/2024 DESIGNING OUR FUTURE C201 DETAILS MA R K : DA T E : DE S C R I P T I O N : CA C H E V A L L E Y | P : 4 3 5 . 2 1 3 . 3 7 6 2 SA L T L A K E | P : 8 0 1 . 2 1 6 . 3 1 9 2 UT A H V A L L E Y | P : 8 0 1 . 8 7 4 . 1 4 3 2 in f o @ c i v i l s o l u t i o n s g r o u p . n e t ww w . c i v i l s o l u t i o n s g r o u p . n e t PA L M E R S U B D I V I S I O N 31 0 E A S T 8 9 0 0 N O R T H PA R A D I S E , U T 8 4 3 2 8 HATUFOETATS PR O F E S S I ONAL ENGI N E E R No. 8243188-2202 MICHAEL E. TAYLOR P: \ 2 0 2 1 \ 2 1 - 3 8 1 p a l m e r s u b d i v i s i o n - p a r a d i s e \ A u t o C A D \ C i v i l \ s h e e t s e t \ 2 1 - 3 8 1 C i v i l D e t a i l s THESE PLANS AND SPECIFICATIONS ARE THE PROPERTY OF CIVIL SOLUTIONS GROUP, INC. AND SHALL NOT BE PHOTOCOPIED, RE-DRAWN, OR USED ON ANY OTHER PROJECT OTHER THAN THE PROJECT SPECIFICALLY DESIGNED FOR, WITHOUT WRITTEN PERMISSION. THE OWNERS AND ENGINEERS OF CIVIL SOLUTIONS GROUP, INC. DISCLAIM ANY LIABILITY FOR ANY CHANGES OR MODIFICATIONS MADE TO THESE PLANS OR THE DESIGN THEREON WITHOUT THEIR CONSENT. THESE PLANS ARE DRAWN TO SCALE WHEN PLOTTED ON A 24" X 36" SHEET OF PAPER. THESE PLANS ARE PRODUCED IN COLOR AND SHOULD BE PLOTTED AS SUCH. PROJECT #: 21-381 DRAWN BY: L. MUMFORD PROJECT MANAGER: M. TAYLOR ISSUED:3/13/2024 2 C201 TYPICAL WATER SERVICE CONNECTION NOT TO SCALE 3 C201 5 C201 6 C201 7 C201 4 C201 3"Ø SCHEDULE 40 PVC PIPE 1.5" AWWA C200 PIPE CAP END OF LINE 15"Ø STAND PIPE WITH LID 3.0' 6" GRAVEL BEDDING 3" TO 1.5" REDUCER METAL BALL VALVE TYPICAL WATER VALVE NOT TO SCALE 8" TAPPING SLEEVE TEE W/ VALVE ASSEMBLY NOT TO SCALE IRRIGATION SERVICE NOT TO SCALE TYPICAL THRUST BLOCK NOT TO SCALE 8.7' 8.7' 10.9" 2.8' 10.9" 3/13/2024 DESIGNING OUR FUTURE C202 DETAILS MA R K : DA T E : DE S C R I P T I O N : CA C H E V A L L E Y | P : 4 3 5 . 2 1 3 . 3 7 6 2 SA L T L A K E | P : 8 0 1 . 2 1 6 . 3 1 9 2 UT A H V A L L E Y | P : 8 0 1 . 8 7 4 . 1 4 3 2 in f o @ c i v i l s o l u t i o n s g r o u p . n e t ww w . c i v i l s o l u t i o n s g r o u p . n e t PA L M E R S U B D I V I S I O N 31 0 E A S T 8 9 0 0 N O R T H PA R A D I S E , U T 8 4 3 2 8 HATUFOETATS PR O F E S S I ONAL ENGI N E E R No. 8243188-2202 MICHAEL E. TAYLOR P: \ 2 0 2 1 \ 2 1 - 3 8 1 p a l m e r s u b d i v i s i o n - p a r a d i s e \ A u t o C A D \ C i v i l \ s h e e t s e t \ 2 1 - 3 8 1 C i v i l D e t a i l s THESE PLANS AND SPECIFICATIONS ARE THE PROPERTY OF CIVIL SOLUTIONS GROUP, INC. AND SHALL NOT BE PHOTOCOPIED, RE-DRAWN, OR USED ON ANY OTHER PROJECT OTHER THAN THE PROJECT SPECIFICALLY DESIGNED FOR, WITHOUT WRITTEN PERMISSION. THE OWNERS AND ENGINEERS OF CIVIL SOLUTIONS GROUP, INC. DISCLAIM ANY LIABILITY FOR ANY CHANGES OR MODIFICATIONS MADE TO THESE PLANS OR THE DESIGN THEREON WITHOUT THEIR CONSENT. THESE PLANS ARE DRAWN TO SCALE WHEN PLOTTED ON A 24" X 36" SHEET OF PAPER. THESE PLANS ARE PRODUCED IN COLOR AND SHOULD BE PLOTTED AS SUCH. PROJECT #: 21-381 DRAWN BY: L. MUMFORD PROJECT MANAGER: M. TAYLOR ISSUED:3/13/2024 1 C202 PARTS SCHEDULE 1 8" C900 PVC 2 8" CHECK VALVE 3 8"x4" REDUCER 4 4" 90° BEND 5 4" GATE VALVE 6 4" TEE 7 4" DISMANTLING JOINT 8 4" D.I. SPOOL 9 C-95-1 SINGLE STAGE 500 GPM 20 HP MULTI-STAGE PUMP 10 CRNE 10-04 0-50 GPM PUMP W/ VARIABLE FREQUENCY DRIVE 11 PEDESTAL STAND 12 4"x1" SADDLE 13 1" QUARTER TURN CHECK VALVE 14 1" DRAIN PIPE. INSTALL BUG SCREEN AT END OF PIPE. 15 AIR VAC RELEASE VALVE 7 3 4 510 6 3 4 5 9 5 6 4 5 4 1 11 CMU BUILDING SEE STRUCTURAL PLANS FOR MORE INFORMATION CMU BUILDING SEE STRUCTURAL PLANS FOR MORE INFORMATION BOOSTER STATION - PLAN VIEW NOT TO SCALE BOOSTER STATION - PROFILE VIEW NOT TO SCALE SEE C102 FOR CONTINUATION SEE C102 FOR CONTINUATION # 1 32 3 7 2 4 597 4 8 8 1.5' 14 13 12 12 14 15 15 3/13/2024 DESIGNING OUR FUTURE C203 DETAILS MA R K : DA T E : DE S C R I P T I O N : CA C H E V A L L E Y | P : 4 3 5 . 2 1 3 . 3 7 6 2 SA L T L A K E | P : 8 0 1 . 2 1 6 . 3 1 9 2 UT A H V A L L E Y | P : 8 0 1 . 8 7 4 . 1 4 3 2 in f o @ c i v i l s o l u t i o n s g r o u p . n e t ww w . c i v i l s o l u t i o n s g r o u p . n e t PA L M E R S U B D I V I S I O N 31 0 E A S T 8 9 0 0 N O R T H PA R A D I S E , U T 8 4 3 2 8 HATUFOETATS PR O F E S S I ONAL ENGI N E E R No. 8243188-2202 MICHAEL E. TAYLOR P: \ 2 0 2 1 \ 2 1 - 3 8 1 p a l m e r s u b d i v i s i o n - p a r a d i s e \ A u t o C A D \ C i v i l \ s h e e t s e t \ 2 1 - 3 8 1 C i v i l D e t a i l s THESE PLANS AND SPECIFICATIONS ARE THE PROPERTY OF CIVIL SOLUTIONS GROUP, INC. AND SHALL NOT BE PHOTOCOPIED, RE-DRAWN, OR USED ON ANY OTHER PROJECT OTHER THAN THE PROJECT SPECIFICALLY DESIGNED FOR, WITHOUT WRITTEN PERMISSION. THE OWNERS AND ENGINEERS OF CIVIL SOLUTIONS GROUP, INC. DISCLAIM ANY LIABILITY FOR ANY CHANGES OR MODIFICATIONS MADE TO THESE PLANS OR THE DESIGN THEREON WITHOUT THEIR CONSENT. THESE PLANS ARE DRAWN TO SCALE WHEN PLOTTED ON A 24" X 36" SHEET OF PAPER. THESE PLANS ARE PRODUCED IN COLOR AND SHOULD BE PLOTTED AS SUCH. PROJECT #: 21-381 DRAWN BY: L. MUMFORD PROJECT MANAGER: M. TAYLOR ISSUED:3/13/2024 1 C203 CIRCLE B IRRIGATION PUMP CURVES NOT TO SCALE 3/13/2024 DESIGNING OUR FUTURE C204 DETAILS MA R K : DA T E : DE S C R I P T I O N : CA C H E V A L L E Y | P : 4 3 5 . 2 1 3 . 3 7 6 2 SA L T L A K E | P : 8 0 1 . 2 1 6 . 3 1 9 2 UT A H V A L L E Y | P : 8 0 1 . 8 7 4 . 1 4 3 2 in f o @ c i v i l s o l u t i o n s g r o u p . n e t ww w . c i v i l s o l u t i o n s g r o u p . n e t PA L M E R S U B D I V I S I O N 31 0 E A S T 8 9 0 0 N O R T H PA R A D I S E , U T 8 4 3 2 8 HATUFOETATS PR O F E S S I ONAL ENGI N E E R No. 8243188-2202 MICHAEL E. TAYLOR P: \ 2 0 2 1 \ 2 1 - 3 8 1 p a l m e r s u b d i v i s i o n - p a r a d i s e \ A u t o C A D \ C i v i l \ s h e e t s e t \ 2 1 - 3 8 1 C i v i l D e t a i l s THESE PLANS AND SPECIFICATIONS ARE THE PROPERTY OF CIVIL SOLUTIONS GROUP, INC. AND SHALL NOT BE PHOTOCOPIED, RE-DRAWN, OR USED ON ANY OTHER PROJECT OTHER THAN THE PROJECT SPECIFICALLY DESIGNED FOR, WITHOUT WRITTEN PERMISSION. THE OWNERS AND ENGINEERS OF CIVIL SOLUTIONS GROUP, INC. DISCLAIM ANY LIABILITY FOR ANY CHANGES OR MODIFICATIONS MADE TO THESE PLANS OR THE DESIGN THEREON WITHOUT THEIR CONSENT. THESE PLANS ARE DRAWN TO SCALE WHEN PLOTTED ON A 24" X 36" SHEET OF PAPER. THESE PLANS ARE PRODUCED IN COLOR AND SHOULD BE PLOTTED AS SUCH. PROJECT #: 21-381 DRAWN BY: L. MUMFORD PROJECT MANAGER: M. TAYLOR ISSUED:3/13/2024 1 C204 3" IRRIGATION METER & METER BOX NOT TO SCALE LENGTH = 5' A.FIVE PIPE DIAMETERS (UPSTREAM) B.TWO PIPE DIAMETERS (DOWNSTREAM) C.FLOW DIRECTION GENERAL NOTES: 1.PIPE USED IN VAULT TO BE CL 50 DUCTILE IRON PVCC CENTER A B 5.0' ROSEMOUNT 8750W MAG METER 3" PVC TO DUCTILE IRON MECHANICAL COUPLER 3" PVC TO DUCTILE IRON MECHANICAL COUPLER DUCTILE IRON PIPE CONCRETE METER BOX PVC BLOCKING