Loading...
HomeMy WebLinkAboutDERR-2024-005037Utah Department of Environmental Quality - UST Release Detection TANK OWNERSHIP Name WIND RIVER PETROLEUM Address 5097 S 900 E, SUITE 200 SALT LAKE CITY, UT 84117 Contact WIND RIVER PETROLEUM Phone Email jkuddes@topstopstores.com TANK LOCATION Name TOP STOP # C-83 Address 750 E 300 N RICHFIELD, UT 84701 A Operator JESSICA KUDDES Phone (435) 753-1025 B Operator TORI HIGGINS Phone (801) 272-9229 Facility ID: 2000688 Inspection Date: 03/07/2024 DISPENSER DETAILS DISP ID/ALT ID SUBSTANCE UDC PIPE FLEX LOC INSTALL DATE UDC INSTALL DATE FIRE VALVE SAT PRESENT UDC TEST DISP FLEX CP TEST 1 - 1/2 Gasoline No None None No No None None TANK DETAILS Tank ID/Alt ID 1 / 1 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Jan. 1, 1990 / 8000 / Substance Stored Gasoline / Regular Tank Material-Mod Composite (Steel w/ FRP)- None ATG / LTT Test None LLD Test None Pipe Material-Mod Galvanized Steel / None Pipe type/STP Cont Pressurized / No STP Flex Connectors LLD Model Spill/Overfill/Sm Delivery / / No PST Fund/Other Type No / Insurance Tank/Pipe Rel Det TankLDNotListed PipeLineTightness CP Tank Test None CP Pipe Test None Tank ID/Alt ID 2 / 2 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Jan. 1, 1990 / 8000 / Substance Stored Gasoline / Premium Tank Material-Mod Composite (Steel w/ FRP)- None ATG / LTT Test None LLD Test None Pipe Material-Mod Galvanized Steel / None Pipe type/STP Cont Pressurized / No STP Flex Connectors LLD Model Spill/Overfill/Sm Delivery / / No PST Fund/Other Type No / Insurance Tank/Pipe Rel Det TankLDNotListed PipeLineTightness CP Tank Test None CP Pipe Test None 2024-03-07 Page 1 of 5 Tank ID/Alt ID 3 / 3 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Jan. 1, 1990 / 8000 / Substance Stored Gasoline / Diesel #2 (U.L.S.) Tank Material-Mod Composite (Steel w/ FRP)- None ATG / LTT Test None LLD Test None Pipe Material-Mod Galvanized Steel / None Pipe type/STP Cont Pressurized / No STP Flex Connectors LLD Model Spill/Overfill/Sm Delivery / / No PST Fund/Other Type No / Insurance Tank/Pipe Rel Det TankLDNotListed PipeLineTightness CP Tank Test None CP Pipe Test None Tank ID/Alt ID 4 / 4 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Jan. 1, 1990 / 8000 / Substance Stored Gasoline / Diesel #2 (U.L.S.) Tank Material-Mod Composite (Steel w/ FRP)- None ATG / LTT Test None LLD Test None Pipe Material-Mod Galvanized Steel / None Pipe type/STP Cont Pressurized / No STP Flex Connectors LLD Model Spill/Overfill/Sm Delivery / / No PST Fund/Other Type No / Insurance Tank/Pipe Rel Det TankLDNotListed PipeMonthlyLineTest CP Tank Test None CP Pipe Test None INSPECTION COMMENTS None 2024-03-07 Page 2 of 5 FACILITY RESPONSES The above accurately represents the facility's release detection records Yes Financial Responsibility Financial responsibility method is ok?Yes TANK RESPONSES Tank 1 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? No Tank 2 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? No Tank 3 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? No Tank 4 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? No Tank 1 Spill/Overfill Tank has a spill prevention device?No Tank 2 Spill/Overfill Tank has a spill prevention device?No Tank 3 Spill/Overfill Tank has a spill prevention device?No Tank 4 Spill/Overfill Tank has a spill prevention device?No DISPENSER RESPONSES MONTHLY LEAK DETECTION MONITORING Mar '23 Apr '23 May '23 Jun '23 Jul '23 Aug '23 Sep '23 Oct '23 Nov '23 Dec '23 Jan '24 Feb '24 Tank 1 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 2 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 3 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 4 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass NON-COMPLIANCE ITEMS TANK 1 No Photos Question:Tank has a spill prevention device? Comments:None TANK 1 No Photos Question:Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Comments:None TANK 2 No Photos Question:Tank has a spill prevention device? Comments:None 2024-03-07 Page 3 of 5 TANK 2 No Photos Question:Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Comments:None TANK 3 No Photos Question:Tank has a spill prevention device? Comments:None TANK 3 No Photos Question:Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Comments:None TANK 4 No Photos Question:Tank has a spill prevention device? Comments:None TANK 4 No Photos Question:Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Comments:None 2024-03-07 Page 4 of 5 Prepared by fueloperator.com Inspection Information Inspector:Warner, Sean Record Created:March 7, 2024, 9:33 a.m. Inspection Date:March 7, 2024 2024-03-07 Page 5 of 5