HomeMy WebLinkAboutDSHW-2024-005961May XX, 2024
Garfield County
Attn: David Dodds, Public Works Director
P.O. Box 77
Panguitch, UT 84759
RE:Compliance Advisory No. 2404071Compliance Evaluation InspectionSW242
Dear Mr. Dodds:
This Compliance Advisory is being sent to your attention as a representative of Garfield County(the Respondent). According to the Division of Waste Management and Radiation Control’s
(Division) records, you are the designated contact person for the Respondent. OnApril 16, 2024, a representative of the Division conducted a compliance evaluation inspection at the Respondent’sJohns
Valley Class I Landfill (Landfill). The scope of the inspection was to verify compliance with Utah Administrative Code R315 (The Rules), the Utah Solid and Hazardous Waste Act (the
Act), and the active Permit for the Landfill, issued December 21, 2018 (DSHW-2018-012101).
Based on observations and information obtained during the inspection, the Director of the Division (Director) is issuing this Compliance Advisory to provide the Respondent with notice
of the followingcompliance issues as well as an opportunity to correct these apparent compliance issues: Utah Administrative Code R315-303-3(7)(d)requires “erecting a sign at the facility
entrance that identifies at least the name of the facility, the hours during which the facility is open for public use, unacceptable materials, and an emergency telephone number”.
Upon arrival at the Landfill, the only signage observed by the inspector showed the facility name and hours and days of operation, which are Monday, Tuesday, and Thursday from 10:00
am to 3:00 pm.
Requested Corrective Action: Please submit photographs demonstrating acceptable signage is in place. The signage should identify at least the name of the landfill, the hours of operation,
unacceptable materials, and an emergency telephone number.Utah Administrative Code R315-303-4(4)(a) requires “an owner or operator of a landfill shall, at the close of each day of operation,
completely cover the waste with at least six inches of soil or an alternative daily cover as allowed in Subsections R315-303-4(4)(b) through R315-303-4(4)(e)”.
The inspector did not observe adequate coverage of the waste at the Landfill. The inspector was informed by Hayden Barney, Landfill Mechanic, that the waste had remained uncovered from
the day prior.
Requested Corrective Action: Please submit photographs demonstrating adequate coverage of waste within the designated cells. Utah Administrative Code R315-302-2(2)(h) requires “a plan
to control wind-blown litter that includes equipment and methods to contain litter, including a schedule and methods to collect scattered litter in a timely manner”.
The inspector did not observe an adequate plan to control wind-blown litter was in place. Wind-blown litter was scattered throughout the landfill property, along fencing, and accumulating
within the leachate pond.
Requested Corrective Action: Please submit photographs demonstrating adequate coverage of waste within the designated cells.
Pursuant to this Compliance Advisory, the Director is providing the Respondent an opportunity to correct the apparent compliance issues. The Director will also consider any evidence
and additional information provided by the Respondent.
Within 30 days of the date of this Compliance Advisory, please submit the following requested documentation regarding each compliance issue and associated corrective actions to the Director:
the cause of each compliance issue;
the specific corrective actions taken, results achieved, and applicable dates;
if future corrective actions are proposed, the specific corrective actions and proposed completion dates, including intermediate milestones, as applicable; and
how the corrective actions will prevent similar compliance issues from recurring.
All information regarding corrective actions relating to this matter should be addressed to the Director at:
Douglas J. Hansen, DirectorDivision of Waste Management and Radiation ControlP.O. Box 144880Salt Lake City, UT 84114-4880or by email at: dwmrcsubmit@utah.gov
DO NOT submit any documents or information through email that are protected, confidential, proprietary, or for which you are claiming business confidentiality under Utah Code § 63G-2-305.
To better ensure records are protected, all such documents and information must be submitted using the mailing address above and
in accordance with Utah Code § 63G-2-309.
If the Respondent demonstrates that it has taken appropriate corrective actionsregarding the matters addressed in this Compliance Advisory, the Director will issue a closeout letter
and will consider this matter to be closed.However, if the Respondent fails to demonstrate appropriate corrective actions within the30-day timeframe, the Director will consider taking
escalated enforcement actions, including seeking financial penalties. In all events, the matters addressed in this Compliance Advisory, including the Respondent’s corrective actions,
will become part of the Respondent’s compliance record and may be considered in connection with future enforcement matters.
If you have any questions, please contact Alex Milne at amilne@utah.gov or by phone at (801) 599-4672.
Sincerely,
Douglas J. Hansen, Director
Division of Waste Management and Radiation Control
DJH/AM
Enclosure(s):Inspection Report (DSHW-2024-005896)
c:Jeremy Roberts, Environmental Health Director, Southwest Utah Public Health Department
Paul Wright, P.E., District Engineer, UDEQ