Loading...
HomeMy WebLinkAboutDERR-2024-013041EZY CHEK SYSTEMS TEST DATE PRODUCT LINE TESTER Testing Company Information DATA SHEET Name Address City Test Location Information Precision Testing Technologies, Inc. 2026 W. Elk Creek Crt. Bluffdale, UT Test Location Information Phone Name Address Technican Information City Name Phone Cert # 801-886-9224 Contact Applied Pressure #1 Product Type:#2 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.00370.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #3 Product Type:#4 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.00370.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #5 Product Type:#6 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.000000.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: Facility ID# : Karmart 205 Harrison Blvd. Ogden, Utah 84401 801-791-6684 Curtis Sneddon Saxon Usher UT-420 REG 1 0 89 15 89 0 0 0 30 89 0 0 0 PASS REG 2 0 83 15 83 0 0 0 30 83 0 0 0 PASS PRM 0 78 15 78 0 0 0 30 78 0 0 0 PASS Saxon Usher UT-420 50 PSI 10/2/2024 pei.org 49 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-9 MECHANICAL AND ELECTRONIC LINE LEAK DETECTORS PERFORMANCE TEST )DFLOLW\1DPH2ZQHU $GGUHVV$GGUHVV &LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH )DFLOLW\,'3KRQH 7HVWLQJ&RPSDQ\3KRQH'DWH 7KLVGDWDVKHHWFDQEHXVHGWRWHVWPHFKDQLFDOOLQHOHDNGHWHFWRUV 0//' DQGHOHFWURQLFOLQHOHDNGHWHFWRUV (//' ZLWKVXEPHUVLEOH WXUELQHSXPS 673 V\VWHPV6HH3(,536HFWLRQVDQGIRUWHVWSURFHGXUHV /LQH1XPEHU 3URGXFW6WRUHG /HDN'HWHFWRU0DQXIDFWXUHU /HDN'HWHFWRU0RGHO 7\SHRI/HDN'HWHFWRU 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' MLLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH &KHFN9DOYH+ROGLQJ3UHVVXUH /LQH5HVLOLHQF\ PO  OLQHEOHHGEDFNYRO XPHDVPHDVXUHGIURPFKHFNYDOYHKROG LQJSUHVVXUHWR]HURSVLJ 6WHS7KURXJK7LPHLQ6HFRQGV WLPHWKH 0//'KHVLWDWHVDWPHWHULQJSUHVVXUH EHIRUHJRLQJWRIXOORSHUDWLQJSUHVVXUH DVPHDVXUHGIURPSVLJZLWKQROHDN LQGXFHGRQWKHOLQH 0HWHULQJ3UHVVXUH 673SUHVVXUHZKHQ VLPXODWHGOHDNUDWHJSKDWSVLJ 2SHQLQJ7LPHLQ6HFRQGV WKHWLPHWKH 0//'RSHQVWRDOORZIXOOSUHVVXUHDIWHU VLPXODWHGOHDNLVVWRSSHG 'RHVWKH673SUHVVXUHUHPDLQDWRU EHORZWKHPHWHULQJSUHVVXUHIRUDWOHDVW VHFRQGVZKHQWKHVLPXODWHGOHDNLV LQGXFHG" <HV1R<HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKHOHDNGHWHFWRUUHVHW WULS ZKHQ WKHOLQHSUHVVXUHLVEOHGRIIWR]HURSVLJ"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKH673SURSHUO\F\FOHRQRIIXQGHU QRUPDOIXHOV\VWHPRSHUDWLRQFRQGLWLRQV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRHLWKHURIWKHDERYHTXHVWLRQVLQGLFDWHVWKH0//'IDLOVWKHWHVW ELLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH +RZPDQ\WHVWF\FOHVDUHREVHUYHG EHIRUHDODUPVKXWGRZQRFFXUV" 'RHVWKHVLPXODWHGOHDNFDXVHDQDODUP"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRWKHDERYHTXHVWLRQLQGL FDWHVWKH(//'IDLOVWKHWHVW 'RHVWKHVLPXODWHGOHDNFDXVHDQ673 VKXWGRZQ" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPH BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB  Precision Testing Technologies Inc.801-886-9224 Karmart 205 Harrison Blvd. Ogden, UT 84401 1200311 Karmart Convenience Stores Inc. 3974 N. 800 W. Ogden, UT 84401 801-791-6684 10/02/2024 1 REG 1 V.R. FX1V 4 30 12 65 1 10 4 4 4 4 4 2 REG 2 V.R. FX1V 4 29 11 70 1 11 5 4 4 4 4 3 PRM V.R. FX1V 4 30 16 70 1 11 3 4 4 4 4 Saxon Usher UT-420 pei.org 45 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-5 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·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´1RµWRDQ\LWHPLQ/LQHVLQGLFDWHVDWHVWIDLOXUH BALL FLOAT VALVE INSPECTION 7DQNWRSILWWLQJVDUHYDSRU WLJKWDQGOHDNIUHH"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R %DOOIORDWFDJHIUHHRIGHEULV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R %DOOLVIUHHRIKROHVDQGFUDFNV DQGPRYHVIUHHO\LQFDJH"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 9HQWKROHLQSLSHLVRSHQDQG QHDUWRSRIWDQN"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R %DOOIORDWSLSHLVSURSHU OHQJWKWRUHVWULFWIORZDW FDSDFLW\" <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµWRDQ\LWHPLQ/LQHVLQGLFDWHVDWHVWIDLOXUH Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO  8VHPDQXIDFWXUHU·VVXJJHVWHGSURFHGXUHIRUGHWHUPLQLQJLIDXWRPDWLFVKXWRIIGHYLFHZLOOVKXWRIIIORZDWFDSDFLW\  8VHPDQXIDFWXUHU·VVXJJHVWHGSURFHGXUHIRUGHWHUPLQLQJLIIORZUHVWULFWLRQGHYLFHZLOOUHVWULFWIORZDWFDSDFLW\ Comments: Precision Testing Technologies Inc.801-886-9224 Karmart 1200311 10/02/20 REG 1 1 12,010 96" OPW 4 4 4 4 4 4 4 4 REG 2 2 12,010 96" OPW 4 4 4 4 4 4 PRM 3 6,005 96" OPW 4 4 4 4 4 4 4 Saxon Usher UT-420 KarmartKarmart pei.org 47 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities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´1RµWKHV\VWHPKDVIDLOHGWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Karmart 1200311 1 REG 1 V.R. TLS 4i 12,010 96 4 4 4 4 80 7/8" 4 1.5" 4 4 2 REG 2 V.R. TLS 4i 12,010 96 4 4 4 4 80 7/8" 4 1.5" 4 4 3 PRM V.R. TLS 4i 6,005 96 4 4 4 4 80 7/8" 4 1.5" 4 4 Saxon Usher UT-420 10/02/2024 Pressure/Vacuum (P/V) Vent Valve Data Sheet Facility Name: Test Date: Address: Test Company: Precision Testing Technologies City: Tester Name: Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): Product: P/V Valve Manufacturer: Model Number: Pass Fail Manufacturers Specified Positive Leak Rate (CFH): Manufacturers Specified Negative Leak Rate (CFH): Measured Positive Leak Rate (CFH): Measured Negative Leak Rate (CFH): Positive Cracking Pressure (in H2O): Negative Cracking Pressure (in H2O): 2.5" to 6" wc <=0.05 cfh @ 2" wc 2.5" to 6" wc <=0.05 cfh @2" wc 2.5" to 6" wc <=0.05 cfh 2" wc 2.5" to 6" wc <=0.05 cfh 2" wc 6" to 10" wc <=0.21 cfh @ 4" wc 6" to 10" wc <=0.21 cfh @ 4" wc 6" to 10" wc <=0.21 cfh @ 4" wc 6" to 10" wc <=0.21 cfh @ 4" wc Karmart 10/02/2024 Saxon Usher UT-420 Reg 1 OPW 623V 4 0.04@2"wc 5"wc 0.18@4"wc 8"wc Reg 2 OPW 623V 4 0.04@2"wc 5"wc 0.18@4"wc 8"wc Prm OPW 623V 4 0.03@2"wc 4"wc 0.15@4"wc 7"wc Karmart Saxon Usher UT-420 10/02/2024