Loading...
HomeMy WebLinkAboutDAQ-2024-0120751 DAQC-PBR039020001-24 Site ID 3902 (B1) MEMORANDUM TO: FILE – SCOUT ENERGY MANAGEMENT, LLC – Hawkeye 9-23 THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager FROM: Chris Jensen, Environmental Scientist DATE: December 10, 2024 SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION INSPECTION DATE: December 4, 2024 SOURCE LOCATION: Lat:40.101636, Long: -110.079617 Duchesne County Business Office: Scout Energy Management, LLC 13800 Montfort Drive, Suite 100 Dallas, TX 75240 SOURCE TYPE: Disposal Water Injection Well API: 4301331984 SOURCE CONTACTS: Abby Molyneaux, Corporate Environmental Contact Phone: 972-325-1170, Email: abby.molyneaux@scoutep.com OPERATING STATUS: Operating PROCESS DESCRIPTION: Produced water is brought here for disposal and enhanced recovery by underground pipeline. The water is reinjected to flood a producing formation. APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil and Gas Industry, and UAC R307-201: Emission Standards: General Emission Standards; and UAC R307-150: Emission Inventories. SOURCE EVALUATION: Site Type: PBR – Uncontrolled No Flare Controls DOGM current 12 month rolling production is: 0. Utah Statute R307-506 requires a source with throughput greater than 8,000 BBLs to have controls. REGISTERED EQUIPMENT: Pneumatic controllers # - $ . ) . ) 2 Visible Emissions Visible emissions are within the following opacity limits: VOC Control Devices and Gasoline engines 0%, Diesel engines 20%, Natural Gas Engines and Boilers, Treater burners & Tank burners 10%, Mobile source dust 10%. [R307-201-3] In Compliance. No visible emissions were detected by use of the USEPA Method 9. VOC emissions are, at all times, minimized as reasonably practicable by equipment design, maintenance and operation practices. [R307-501-4(1)] In Compliance. The source was surveyed by AVO and with an OGI camera and was found to be well-kept with no visible or fugitive emissions. Pneumatic Controllers All natural gas-driven pneumatic controllers are in compliance with 40CFR 60.5390 or 60.5390a as applicable. Tagging and record keeping requirements are not required. [R307-502-4] In Compliance. This source does not use continuous bleed natural gas-driven pneumatic controllers. Storage Vessels None installed. Natural Gas Engines None installed. Emission Inventory: An emissions inventory has been submitted within the past three years. [R307-150-9(1)] In Compliance. The operator submitted for the 2020 inventory but the 2023 inventory has not yet been released. Oil and Gas Industry Registration Requirement The source is registered with the DAQ. [R307-505-3(3)] In Compliance. Registration has been updated within 30 days of a company name change, removal or addition of control devices, or termination of operations. [R307-505-3(3)] In Compliance. 3 PREVIOUS ENFORCEMENT ACTIONS: None in the past 5 years. COMPLIANCE STATUS & RECOMMENDATIONS: In regards to the site, the overall status is: In Compliance. The source was surveyed by AVO and with an OGI camera and was found to be well-kept with no visible or fugitive emissions. This is a water flood injection well. All of the production equipment has been removed. No producing oil wells remain on this source. RECOMMENDATION FOR NEXT INSPECTION: The DAQ has no recommendations for the next inspector other than what are customary. The DAQ was joined by Scout personnel during the site inspection. RECOMMENDATIONS FOR NSR: None. ATTACHMENTS: None.