Loading...
HomeMy WebLinkAboutDERR-2024-004927Utah Department of Environmental Quality - UST Release Detection TANK OWNERSHIP Name PARKLAND USA - DIVISION OF PARKLAND CORPORATION Address 1970 E. 68TH AVE. DENVER, CO 80229 Contact PARKLAND USA - DIVISION OF PARKLAND CORPORATION Phone Email Nancy.coen@parklandusa.com TANK LOCATION Name SUNNY SHOPPER SILVER EAGLE #80187 Address 259 W OLD HWY 89 ELSINORE, UT 84724 A Operator None Phone None B Operator SAME Phone SAME Facility ID: 2000336 Inspection Date: 03/05/2024 DISPENSER DETAILS DISP ID/ALT ID SUBSTANCE UDC PIPE FLEX LOC INSTALL DATE UDC INSTALL DATE FIRE VALVE SAT PRESENT UDC TEST DISP FLEX CP TEST 1 - 1/2 Gas/Diesel No None None No No None None 2 - 3/4 Gas/Diesel No None None No No None None 3 - 5/6 Gas/Diesel No None None No No None None 4 - 7/8 Gas/Diesel No None None No No None None 5 - 9/10 Gas/Diesel No None None No No None None 6 - 11/12 Gas/Diesel No None None No No None None TANK DETAILS Tank ID/Alt ID 4 / 4 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc June 30, 1984 / 10000 / Substance Stored Gasoline / Regular Tank Material- Mod Impressed Current Cathodic Protection-None ATG / LTT Test None LLD Test None Pipe Material-Mod Bare Steel / None Pipe type/STP Cont Pressurized / Yes STP Flex Connectors Steel Flex in Sump LLD Model Spill/Overfill/Sm Delivery > 15 gal. Spill Bucket / / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankTightness PipeLineTightness / PipeSIR CP Tank Test None CP Pipe Test None Tank ID/Alt ID 5 / 5 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Jan. 1, 1985 / 10000 / Substance Stored Gasoline / Premium Tank Material- Mod Impressed Current Cathodic Protection-None ATG / LTT Test None LLD Test None Pipe Material-Mod Bare Steel / None Pipe type/STP Cont Pressurized / No STP Flex Connectors Steel Flex in Sump LLD Model Spill/Overfill/Sm Delivery > 15 gal. Spill Bucket / / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankTightness PipeLineTightness / PipeSIR CP Tank Test None CP Pipe Test None 2024-03-05 Page 1 of 5 Tank ID/Alt ID 6 / 6 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc July 1, 1995 / 6000 / Substance Stored Gasoline / Diesel #2 (U.L.S.) Tank Material- Mod Asphalt Coated or Bare Steel- None ATG / LTT Test None LLD Test None Pipe Material-Mod Bare Steel / None Pipe type/STP Cont Pressurized / Yes STP Flex Connectors Steel Flex in Sump LLD Model Spill/Overfill/Sm Delivery > 15 gal. Spill Bucket / / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankTightness PipeLineTightness CP Tank Test None CP Pipe Test None Tank ID/Alt ID 7 / 7 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Jan. 1, 1910 / 18000 / Substance Stored Gasoline / Regular Tank Material-Mod Asphalt Coated or Bare Steel- ATG / LTT Test None LLD Test None Pipe Material-Mod Bare Steel / None Pipe type/STP Cont Pressurized / Yes STP Flex Connectors Steel Flex in Sump LLD Model Spill/Overfill/Sm Delivery Dry Connect Fitting / / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankTightness PipeLineTightness / PipeSIR CP Tank Test None CP Pipe Test None Tank ID/Alt ID 8 / 8 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Jan. 1, 1910 / 8000 / Substance Stored Diesel / Off-road Diesel Tank Material-Mod Asphalt Coated or Bare Steel- ATG / LTT Test None LLD Test None Pipe Material-Mod Bare Steel / None Pipe type/STP Cont Pressurized / Yes STP Flex Connectors Steel Flex in Sump LLD Model Spill/Overfill/Sm Delivery > 15 gal. Spill Bucket / / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankTightness PipeLineTightness / PipeSIR CP Tank Test None CP Pipe Test None INSPECTION COMMENTS None 2024-03-05 Page 2 of 5 FACILITY RESPONSES The above accurately represents the facility's release detection records Yes Financial Responsibility Financial responsibility method is ok?Yes TANK RESPONSES Tank 4 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 5 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 6 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 7 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 8 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 4 Spill/Overfill Tank has a spill prevention device?No Tank 5 Spill/Overfill Tank has a spill prevention device?No Tank 6 Spill/Overfill Tank has a spill prevention device?No Tank 7 Spill/Overfill Tank has a spill prevention device?No Tank 8 Spill/Overfill Tank has a spill prevention device?No DISPENSER RESPONSES Dispenser 3/4 Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes Dispenser 7/8 Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes Dispenser 1/2 Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes Dispenser 5/6 Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes 2024-03-05 Page 3 of 5 Dispenser 11/12 Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes Dispenser 9/10 Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes MONTHLY LEAK DETECTION MONITORING Mar '23 Apr '23 May '23 Jun '23 Jul '23 Aug '23 Sep '23 Oct '23 Nov '23 Dec '23 Jan '24 Feb '24 Tank 4 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 5 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 6 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 7 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 8 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl NON-COMPLIANCE ITEMS TANK 4 No Photos Question:Tank has a spill prevention device? Comments:None TANK 5 No Photos Question:Tank has a spill prevention device? Comments:None TANK 6 No Photos Question:Tank has a spill prevention device? Comments:None TANK 7 No Photos Question:Tank has a spill prevention device? Comments:None TANK 8 No Photos Question:Tank has a spill prevention device? Comments:None 2024-03-05 Page 4 of 5 Prepared by fueloperator.com Inspection Information Inspector:Warner, Sean Record Created:March 5, 2024, 2:06 p.m. Inspection Date:March 5, 2024 2024-03-05 Page 5 of 5