HomeMy WebLinkAboutDAQ-2024-0120151 DAQC-1205-24 Site ID 12428 (B4) MEMORANDUM TO: STACK TEST FILE – URBAN OIL AND GAS GROUP – Clawson Springs Central Production Facility THROUGH: Harold Burge, Major Source Compliance Section Manager FROM: Robert Sirrine, Environmental Scientist DATE: December 4, 2024 SUBJECT: Location: 2 miles east of Hiawatha, Highway 122, Carbon County, Utah Contact: Kirt Rasmussen – 435-820-9801 Source: Compressor Engines C-101, C-103, and C-104 Tester: Emissions Science Inc. Tim Olinger – 970-628-4849 FRS ID #: UT0000004900700068 Permit/AO #: DAQE-AN124280010-22 dated September 28, 2022 Action Code: 3A Subject: Review of Stack Test Report dated October 14, 2024 On October 14, 2024, the Utah Division of Air Quality (DAQ) received an initial stack test report, and then on December 4, 2024, additional information for stack emissions testing of Urban Oil and Gas Group, LLC – Clawson Springs Central Production Facility, compressor engines C-101, C-103, and C-104 located 2-miles east of Hiawatha on Highway 122, Carbon County, Utah. Portable analyzer testing was performed on September 26, 2024, to determine compliance with AO Condition II.B.2.a, for NOX and CO emission limits. The DAQ calculated test results are: Source Test Date RM/Pollutant DAQ Result Test Result Limit C-101 9/26/24 7/NOX 2.46 lb/hr 2.46 lb/hr 5.15 lb/hr 254 ppmdv* 254 ppmdv 282 ppmdv* 1.34 g/hp-hr 1.33 g/hp-hr 1.74 g/hp-hr 10/CO 2.87 lb/hr 2.87 lb/hr 5.51 lb/hr 488 ppmdv* 488 ppmdv* 498 ppmdv* 1.56 g/hp-hr 1.56 g/hp-hr 1.87 g/hp-hr C-103 9/26/24 7/NOX 2.06 lb/hr 2.06 lb/hr 5.15 lb/hr 220 ppmdv* 220 ppmdv* 282 ppmdv* 1.10 g/hp-hr 1.10 g/hp-hr 1.74 g/hp-hr 10/CO 2.53 lb/hr 2.53 lb/hr 5.51 lb/hr 442 ppmdv* 443 ppmdv* 498 ppmdv* 1.35 g/hp-hr 1.35 g/hp-hr 1.87 g/hp-hr * - / $ - - $ ) 2 C-104 9/26/24 7/NOX 2.58 lb/hr 2.58 lb/hr 5.15 lb/hr 252 ppmdv* 252 ppmdv* 282 ppmdv* 1.44 g/hp-hr 1.44 g/hp-hr 1.74 g/hp-hr 10/CO 2.39 lb/hr 2.38 lb/hr 5.51 lb/hr 383 ppmdv* 383 ppmdv* 498 ppmdv* 1.33 g/hp-hr 1.33 g/hp-hr 1.87 g/hp-hr *@7.9% O2 DEVIATIONS: None noted CONCLUSION: The stack emissions test report, with additional information and calculation, appears to be acceptable. RECOMMENDATION: The source should be considered to have been in compliance with the applicable limits at the time of testing. The source referenced their previous AO, DAQE-634-01 dated August 15, 2001, originally written for Anadarko Petroleum Corporation, in their pretest protocol. That AO was superseded by a new AO, DAQE-AN124280010-22 dated September 28, 2022, written for Urban Oil and Gas Group, LLC. HPV: No ATTACHMENTS: Stack test report received October 14, 2024 Letter with the test report from Urban Oil and Gas Group Additional, updated test information received December 4, 2024 DAQ generated excel spreadsheets Source ID:C-101 C-102 C-103 C-104 NOx Permittted Limits lb/hr - g/bhp-hr - ppm @ 7.9% O2 CO Permittted Limits lb/hr - g/bhp-hr - ppm @ 7.9% O2 Corrected O2 %8.1 No Sample 8.2 7.9 N/A N/A Corrected NOx ppm 250.3 214.0 252.5 N/A N/A Corrected CO ppm 480.1 432.3 383.3 N/A N/A Tested lb/hr 2.46 NOx 2.87 CO 2.06 NOx 2.53 CO 2.58 NOx 2.38 CO 5.15 lb/hr 5.51 lb/hr Tested g/bhp-hr 1.56 NOx 1.33 CO 1.10 NOx 1.35 CO 1.44 NOx 1.33 CO 1.74 g/bhp-hr 1.87 g/bhp-hr Tested ppm @ 7.9% O2 254.39 NOx 487.91 CO 219.52 NOx 443.42 CO 252.0 NOx 382.6 CO 282 ppm 498 ppm Urban Oil & Gas Group, LLC Clawson Spring Compression Station 3rd-Quarter 2024 Test Date: 09/26/2024 Emissions Science, Inc. was contracted by Urban Oil & Gas Group, LLC to conduct multiple emissions tests using a portable gas analyzer at the Clawson Spring Compression Station near Price Utah. The purpose of the testing was to comply with the construction permit issued by the Utah Department of Environmental Quality, Air Quality Division and/or under the guidelines for the company operations and maintenance plan for this facility. Emissions Science, Inc. followed the procedures and specifications of the portable analyzer test protocol published by the CDPHE in Colorado for this project. The following table summarizes the unit indentifiers, date tested, tested concentrations, tested mass emission rates and permitted limits for each, individual unit tested. Other detailed information can be found within the report. The sources were not able to acheive a load 90% of site rated horsepower during the testing program due to lower field pressure, but all sources were reportedly operating at least 90% of the averaged production capabilities over the last three years as allowed in the facility permit. Emissions Science, Inc www.emissions-science.com P2 Grand Junction, COPhone: 970.628.4849 Urban Oil & Gas, LLC Caterpillar 3516 TALE Permit or AIRS #: DAQE 634-01 Clawson Spring C.S. Source ID: C-101 Serial #: 4EK02988 Test Date: 9/26/2024 Site Rated HP: 1206 E.S.I Analyst Andrew Edwards Source ID: Reportable Units Tested Results: NOx Allowable Limits: NOx Tested Results: CO Allowable Limits: CO C-101 ppmvd @ 7.9% O2 254.39 282.00 487.91 498.00 Lb/Hr 2.46 5.15 2.87 5.51 Source Compliant?YES YES Emissions Science, Inc. performed an emissions test for this unit using a portable emissions analyzer equipped with electrochemical sensors. The sensors used for the test were found to be within calibration requirements and properly tested for Q/A & Q/C in accordance with the Portable Analyzer Guidelines published by the Utah Department of Environmental Quailty, Air Quailty Divison. A twenty-one minute test was performed on this source under normal load conditions for this site. Emission rates for NOx and CO were calculated using EPA Method 19 and based on stack gas concentrations, percent oxygen and best available fuel usage or default fuel efficiency values where no fuel meter was present. Emissions Science, Inc www.emissions-science.com 1. Grand Junction, CO 81507Phone: 970.628.4849 Detailed Source Test Data Client:Urban Oil & Gas, LLC Engine Type: Facility:Clawson Spring C.S.Source ID: Control Equipment.A/F "Y" SCO "N"Site Rated HP: Permit or AIRS #:DAQE 634-01 Serial #: Test Date:9/26/2024 Analyst: Job Code:UOG-24-132 Analyzer ID: Engine Operations Data:Fuel Calculation Data: RPM 1193 Suction Pressure (PSI)3.7 Metered Fuel Usage: Discharge Pressure (PSI)592 Fuel Use (SCF/D)136000 Manifold Pressure (PSI)20.6 Fuel Use (SCF/H)5666.7 Manifold Temperature (F)140.0 Fuel Value (BTU/SCF)1020.0 Unit Volume (MMCF/D)2.12 Fuel Use (MMBTU/HR)5.78 Fuel Value (BTU/SCF)1020 F's of D (SCF/MMBTU)8710 Fuel Use Based on BSFC Engine Operation Hours 92915 BHP 835.60 Observed Stack O2 %8.0 Efficiency (BTU/BHP-HR) Engine Timing (BTDC) °27.0 Fuel Use (MMBTU/HR)0.000 Site Conditions Data Fuel Use For Calculations (MMBTU/HR)5.78 Barometric Pressure ("Hg)23.12 Relative Humidity (%)17 Emission Controls Data Ambient Temperature (F)76 Catalyst Temperature Ambient Temperature (C)24.4 Inlet Temperature (F) °N/A Site Elevation ('ASL)6716 Outlet Temperature (F) °N/A Portable Analyzer Temperature Catalyst Differential Pressure NO Temperature (F) ° 1/3 of Test 61 Inlet / Outlet Pressure ("H2O)N/A NO Temperature (F) ° 2/3 of Test 61 ∆ P ("H2O)N/A HP Calculations AFR NOx PPM Set. / Reading 240 / 239.1 Fuel Use & BSFC Emissions Results Fuel Use (MMBTU/Hr)5.78 BSFC (BTU/BHP-Hr)CO (LB/MMBTU)0.50 BHP NOx (LB/MMBTU)0.43 CO (LB/HR)2.87 Percent Load HP NOx (LB/HR)2.46 Source Running Max HP 1150 CO (PPMVD @ 7.9% O2)487.91 % Load 72.7 NOx (PPMVD @ 7.9% O2)254.39 BHP 835.6 CO (GM/BHP-HR) {1.87}1.56 NOx (GM/BHP-HR) {1.74}1.33 Generator HP Kilo-Watt Produced CORRECTED VALUES 3-Phase (Power Factor .80) 0.00 O2 (%)8.1 Single Phase 0.00 CO (ppm)480.1 BHP 0.00 NO (ppm)174.6 NO2 (ppm)75.7 Trapped or Calculated NOx (ppm)250.3 Measured BHP BHP Used for Test 836 BSFC (BTU/BHP-HR) 6917 Andrew Edwards TESTO 3289 Caterpillar 3516 TALE C-101 1206 4EK02988 Emissions Science, Inc. 2.Grand Junction CO 81507Phone: 970.628.4849 Unit ID: C-101 Date: 09/26/24 Data Log File Minute: Date TIME % O2 ppm CO ppm NO ppm NO2 1 9/26/2024 12:28:42 8.2 481 170 95.7 2 9/26/2024 12:29:42 8.2 483 172 95.4 3 9/26/2024 12:30:42 8.2 485 171 90.3 4 9/26/2024 12:31:42 8.1 483 166 83.6 5 9/26/2024 12:32:42 8.1 482 172 76.0 6 9/26/2024 12:33:42 8.1 483 174 67.7 7 9/26/2024 12:34:42 8.1 483 176 62.1 8 9/26/2024 12:35:42 8.1 483 179 62.4 9 9/26/2024 12:36:42 8.1 481 172 63.5 10 9/26/2024 12:37:42 8.1 480 172 64.3 11 9/26/2024 12:38:42 8.1 482 175 66.4 12 9/26/2024 12:39:42 8.1 483 175 69.1 13 9/26/2024 12:40:42 8.1 484 177 71.6 14 9/26/2024 12:41:42 8.1 483 174 73.5 15 9/26/2024 12:42:42 8.1 482 177 75.9 16 9/26/2024 12:43:42 8.1 483 178 78.8 17 9/26/2024 12:44:42 8.1 480 175 80.8 18 9/26/2024 12:45:42 8.1 480 173 82.9 19 9/26/2024 12:46:42 8.1 478 172 83.8 20 9/26/2024 12:47:42 8.1 479 172 84.9 21 9/26/2024 12:48:42 8.2 479 175 87.7 Avg. 8.1 481.8 173.7 77.0 Emissions Science, Inc. 3. Grand Junction, CO 81507Phone: 970.628.4849 Date : 9/23/2024 Analyzer Model: Testo 350 Analyst : Andrew Edwards Analyzer Serial #: 3289 Gas Species Analyzer Range Calibration Gas Concentration (ppm or %) Sensor Response ppm CO / NO / NO2 % O2 Absolute Difference Percent of Span Linearity Valid (Yes/No) NO2 ppm Zero 0.0 0 0.00 0.00 YES Mid 78.66 78.8 0.14 0.10 YES Span 145.6 145.9 0.30 0.21 YES NO ppm Zero 0.0 0 0.00 0.00 YES Mid 59.08 60 0.92 0.77 YES Span 120.0 121 1.00 0.83 YES Zero 0.0 0 0.00 0.00 YES Mid 120.0 121 1.00 0.42 YES Span 235.3 236 0.70 0.30 YES Zero 0.0 0 0.00 0.00 YES Mid 235.3 236 0.70 0.13 YES Span 554.2 555 0.80 0.14 YES Zero 0.0 0 0.00 0.00 YES Mid 554.2 555 0.80 0.08 YES Span 1065.0 1067 2.00 0.19 YES CO ppm Zero 0.0 0 0.00 0.00 YES Mid 27.75 28 0.25 0.43 YES Span 57.58 58 0.42 0.73 YES Zero 0.0 0 0.00 0.00 YES Mid 57.58 58 0.42 0.35 YES Span 121.1 121 0.10 0.08 YES Zero 0.0 0 0.00 0.00 YES Mid 121.1 121 0.10 0.04 YES Span 241.7 243 1.30 0.54 YES Zero 0.0 0 0.00 0.00 YES Mid 241.7 243 1.30 0.27 YES Span 488.8 489 0.20 0.04 YES Zero 0.0 0 0.00 0.00 YES Mid 488.8 489 0.20 0.02 YES Span 1023.0 1023 0.00 0.00 YES O2 %Zero 0.0 0.00 0.00 0.00 YES Mid 10.50 10.50 0.00 0.00 YES Span 20.90 21.00 0.10 0.48 YES Appendix A Linearity Check Data Sheet LINEARITY CHECK Emissions Science, Inc. 4.Grand Junction, CO 81507Phone: 970.628.4849 Analyst: Andrew Edwards Analyzer Serial # 3289 Date:09/23/24 Date:09/23/24 Date:09/23/24 NO Gas Span ppm NO2 Gas Span ppm CO Gas Span ppm 1065 145.6 1023 Time (Min.) Analyzer ppm Time (Min.) Analyzer ppm Time (Min.) Analyzer ppm 0 0 0 0.0 0 0 1 1065 1 145.8 1 1023 2 1065 2 145.7 2 1023 3 1064 3 145.6 3 1023 4 1064 4 145.5 4 1022 5 1064 5 145.4 5 1022 6 1063 6 145.4 6 1022 7 1063 7 145.4 7 1021 8 1062 8 145.3 8 1021 9 1062 9 145.3 9 1020 10 1061 10 145.2 10 1020 11 1061 11 145.3 11 1019 12 1061 12 145.2 12 1019 13 1060 13 145.3 13 1019 14 1060 14 145.2 14 1018 15 1060 15 145.1 15 1018 16 1059 16 145.1 16 1017 17 1059 17 144.9 17 18 18 18 19 19 19 20 20 20 21 21 21 22 22 22 23 23 23 24 24 24 25 25 25 26 26 26 27 27 27 28 28 28 29 29 29 30 30 30 31 31 31 32 32 32 33 33 33 34 34 34 35 35 35 36 36 36 37 37 37 30 Minute Sensor Test 30 Minute Sensor Test 30 Minute Sensor Test Maximum ppm Maximum ppm Maximum ppm Minimum ppm Minimum ppm Minimum ppm Max. Deviation % Max. Deviation % Max. Deviation % 15 Minute Sensor Test 15 Minute Sensor Test 15 Minute Sensor Test Maximum ppm 1065 Maximum ppm 145.8 Maximum ppm 1023 Minimum ppm 1059 Minimum ppm 144.9 Minimum ppm 1017 Max. Deviation % 0.56 Max. Deviation % 0.62 Max. Deviation % 0.59 Stability Time 1 Stability Time 1 Stability Time 1 Stability Valid?Yes Stability Valid?Yes Stability Valid?Yes Appendix B Sensor Stability Test Maximum Deviation = 100*(Max. Conc.- Min. Conc.)/ Span Gas Conc. Emissions Science, Inc. 5.Grand Junction, CO 81507Phone: 970.628.4849 Appendix C Calibration Error Check Data Sheet Client: Urban Oil & Gas, LLC Facility : Clawson Spring C.S. Source ID : C-101 Date : 9/26/2024 Analyst : Andrew Edwards Permit # : DAQE 634-01 Analyzer Manufacturer/Model # : TESTO 3289 PRETEST CALIBRATION ERROR CHECK A B (A-B) (A-B)/A*(100) Pump Flow Rate (lpm) Calibration Gas Concentration (ppm) Analyzer Reading (ppm) Absolute Difference Percent of Span Difference Calibration Valid (YES or NO) Response Time (min.) NO Zero 3.0 0 0 0 0.0 YES 1 Span 3.0 235.3 236 0.7 0.3 YES 1 NO2 Zero 3.0 0 0 0 0.0 YES 1 Span 3.0 78.66 79.9 1.24 1.6 YES 1 CO Zero 3.0 0 0 0 0.0 YES 1 Span 3.0 488.8 491 2.2 0.5 YES 1 O2 Zero 3.0 0.0 0.0 0 0.0 YES 1 Span 3.0 20.95 20.97 0.02 0.1 YES 1 Pretest Calibration NO Cell Temperature (F):60 POST TEST CALIBRATION ERROR CHECK Interference A B (A-B) (A-B)/A*(100) Check Pump Flow Rate (lpm) Calibration Gas Concentration (ppm) Analyzer Reading (ppm) Absolute Difference Percent of Span Difference Calibration Valid (YES or NO) Avgeraged Pre / Post Test Analyzer Readings CO/NO Monitor Response (ppm) NO Zero 3.0 0 0 0 0.0 YES 0 0 Span 3.0 235.3 232 3.3 1.4 YES 234 NO2 Zero 3.0 0 0 0 0.0 YES 0 Span 3.0 78.66 80.1 1.44 1.8 YES 80 CO Zero 3.0 0 0 0 0.0 YES 0 0 Span 3.0 488.8 490 1.2 0.2 YES 490.5 O2 Zero 3.0 0.0 0.0 0 0.0 YES 0 Span 3.0 20.95 20.98 0.03 0.1 YES 20.975 Post Test Calibration NO Cell Temperature (F):62 CO Interference Response (Ico,%) 0.00 NO Interference Response (Ino,%) 0.00 Emissions Science, Inc. 6.Grand Junction, CO 81507Phone: 970.628.4849 Appendix D: Detailed Reciprocating Engine Test Results Client :Urban Oil & Gas, LLC Date : 9/26/24 Facility Clawson Spring C.S. Source #: C-101 Source Manufacturer & Model # : Caterpillar 3516 TALE Site-Rated Horsepower : 1206 Source Serial # : 4EK02988 Type of Emission Control : A/F "Y" SCO "N" Analyst : Andrew Edwards Analyzer ID# : TESTO 3289 Analyzer Manufacturer/Model # : Testo 350 Operating Conditions Source operating at 90% or greater site rated horsepower during test? NO Engine RPM Suction Pressure (PSI) Discharge Pressure (PSI) Daily Volume (MMCFD) Engine Fuel Consumption (MMBtu/hr) Fuel Heat Content (Btu/scf) Brake Specific Fuel Consumption (Btu/hp-hr) Engine Tested Horsepower Engine Runtime Hours 1193 3.7 592 2.12 5.78 1020 6917 836 92915 Test Results Test Start Time : 12:28:42 NO Cell Temp. (F) after 1/3 of test : 61 Test End Time : 12:48:42 NO Cell Temp. (F) after 2/3 of test : 61 NOx (NO+NO2) Avg. Tested NO ppm Corrected NO ppm Avg. Tested NO2 ppm Corrected NO2 ppm Corrected NOx ppm Tested ppmvd @ 7.9% O2 Tested lb/hr Allowable ppmvd @ 7.9% O2 Allowable lb/hr 173.7 174.6 77.0 75.7 250.3 254.39 2.46 282.00 5.15 O2 CO Avg. Tested O2 % Corrected O2 % Avg. Tested CO ppm Corrected CO ppm Tested ppmvd @ 7.9% O2 Tested lb/hr Allowable ppmvd @ 7.9% O2 Allowable lb/hr 8.1 8.1 481.8 480.1 487.91 2.87 498.00 5.51 I certify to the best of my knowledge the test results are accurate and representative of the emissions from this source. Print Name Signature (Responsible Company Official) (ESI Analyst) Name: Andrew Edwards 0 100 200 300 400 500 600 123456789101112131415161718192021 Co n c e n t r a t i o n s Minutes Graphical Format % O2 ppm CO ppm NO ppm NO2 Emissions Science, Inc. 7. Grand Junction, CO 81507Phone: 970.628.4849 Caterpillar Supplied Information Load 100%75%50% Engine Horsepower 1206 905 603 Fuel Consumption 7401 7657 8128 Btu/bhp-hr Intake Manifold Pressure 19.9 12.6 4.8 psig Source: C-101 Number of Compression Stages 3 Suction Pressure 3.7 psi Discharge Pressure 592 psi Volume of Gas Moved 2.12 MMscfd F Factor 1.1 Brake Horsepower 835.6 hp <site rating of 1206 hp Intake Manifold Pressure psigBrake Horsepower 408.6 hp Higher Heating Value 1004 Btu/scf Measured Fuel Consumption scf/hr Horsepower Default Fuel Consumption 9400 Btu/hp-hr 0.0 Provided by ESI 8300 Btu/hp-hr 0.0 Interpolated from Cat Data #DIV/0!Btu/hp-hr #DIV/0! User defined entries Method 3 - Wyoming Portable Analyzer Protocol Hp Calculations Method 1 - GPSA Handbook Equation 13-4 Catperpillar 3516LE Horsepower Calculation Methods Method 2 - Interpolation of Intake Manifold Pressure Urban Oil & Gas, LLC Caterpillar 3516 TALE Permit or AIRS #: DAQE 634-01 Clawson Spring C.S. Source ID: C-103 Serial #: 4EK01860 Test Date: 9/26/2024 Site Rated HP: 1206 E.S.I Analyst Andrew Edwards Source ID: Reportable Units Tested Results: NOx Allowable Limits: NOx Tested Results: CO Allowable Limits: CO C-103 ppmvd @ 7.9% O2 219.52 282.00 443.42 498.00 Lb/Hr 2.06 5.15 2.53 5.51 Source Compliant?YES YES Emissions Science, Inc. performed an emissions test for this unit using a portable emissions analyzer equipped with electrochemical sensors. The sensors used for the test were found to be within calibration requirements and properly tested for Q/A & Q/C in accordance with the Portable Analyzer Guidelines published by the Utah Department of Environmental Quailty, Air Quailty Divison. A twenty-one minute test was performed on this source under normal load conditions for this site. Emission rates for NOx and CO were calculated using EPA Method 19 and based on stack gas concentrations, percent oxygen and best available fuel usage or default fuel efficiency values where no fuel meter was present. Emissions Science, Inc www.emissions-science.com 1. Grand Junction, CO 81507Phone: 970.628.4849 Detailed Source Test Data Client:Urban Oil & Gas, LLC Engine Type: Facility:Clawson Spring C.S.Source ID: Control Equipment.A/F "Y" SCO "N"Site Rated HP: Permit or AIRS #:DAQE 634-01 Serial #: Test Date:9/26/2024 Analyst: Job Code:UOG-24-132 Analyzer ID: Engine Operations Data:Fuel Calculation Data: RPM 1200 Suction Pressure (PSI)3.0 Metered Fuel Usage: Discharge Pressure (PSI)589 Fuel Use (SCF/D)132000 Manifold Pressure (PSI)19.6 Fuel Use (SCF/H)5500.0 Manifold Temperature (F)131.0 Fuel Value (BTU/SCF)1020.0 Unit Volume (MMCF/D)2.01 Fuel Use (MMBTU/HR)5.61 Fuel Value (BTU/SCF)1020 F's of D (SCF/MMBTU)8710 Fuel Use Based on BSFC Engine Operation Hours 58153 BHP 849.00 Observed Stack O2 %8.2 Efficiency (BTU/BHP-HR) Engine Timing (BTDC) °27.0 Fuel Use (MMBTU/HR)0.000 Site Conditions Data Fuel Use For Calculations (MMBTU/HR)5.61 Barometric Pressure ("Hg)23.15 Relative Humidity (%)20 Emission Controls Data Ambient Temperature (F)73 Catalyst Temperature Ambient Temperature (C)22.8 Inlet Temperature (F) °N/A Site Elevation ('ASL)6716 Outlet Temperature (F) °N/A Portable Analyzer Temperature Catalyst Differential Pressure NO Temperature (F) ° 1/3 of Test 60 Inlet / Outlet Pressure ("H2O)N/A NO Temperature (F) ° 2/3 of Test 60 ∆ P ("H2O)N/A HP Calculations AFR NOx PPM Set. / Reading 230 / 223.5 Fuel Use & BSFC Emissions Results Fuel Use (MMBTU/Hr)5.61 BSFC (BTU/BHP-Hr)CO (LB/MMBTU)0.45 BHP NOx (LB/MMBTU)0.37 CO (LB/HR)2.53 Percent Load HP NOx (LB/HR)2.06 Source Running Max HP 1156.0 CO (PPMVD @ 7.9% O2)443.42 % Load 73.4 NOx (PPMVD @ 7.9% O2)219.52 BHP 849.0 CO (GM/BHP-HR) {1.87}1.35 NOx (GM/BHP-HR) {1.74}1.10 Generator HP Kilo-Watt Produced CORRECTED VALUES 3-Phase (Power Factor .80) 0.00 O2 (%)8.2 Single Phase 0.00 CO (ppm)432.3 BHP 0.00 NO (ppm)146.0 NO2 (ppm)68.0 Trapped or Calculated NOx (ppm)214.0 Measured BHP BHP Used for Test 849 BSFC (BTU/BHP-HR) 6608 Andrew Edwards TESTO 3289 Caterpillar 3516 TALE C-103 1206 4EK01860 Emissions Science, Inc. 2.Grand Junction CO 81507Phone: 970.628.4849 Unit ID: C-103 Date: 09/26/24 Data Log File Minute: Date TIME % O2 ppm CO ppm NO ppm NO2 1 9/26/2024 11:38:33 8.3 427 142 69.5 2 9/26/2024 11:39:33 8.3 428 143 65.2 3 9/26/2024 11:40:33 8.3 428 141 62.9 4 9/26/2024 11:41:33 8.2 430 144 62.0 5 9/26/2024 11:42:33 8.2 431 145 62.2 6 9/26/2024 11:43:33 8.2 431 146 62.3 7 9/26/2024 11:44:33 8.2 430 145 62.8 8 9/26/2024 11:45:33 8.2 432 148 63.9 9 9/26/2024 11:46:33 8.2 432 149 64.7 10 9/26/2024 11:47:33 8.2 430 146 65.9 11 9/26/2024 11:48:33 8.2 429 146 66.9 12 9/26/2024 11:49:33 8.2 430 148 68.5 13 9/26/2024 11:50:33 8.2 429 147 69.9 14 9/26/2024 11:51:33 8.2 428 148 71.2 15 9/26/2024 11:52:33 8.2 429 148 72.4 16 9/26/2024 11:53:33 8.2 427 147 73.4 17 9/26/2024 11:54:33 8.2 430 150 75.1 18 9/26/2024 11:55:33 8.2 430 147 75.1 19 9/26/2024 11:56:33 8.2 429 149 76.2 20 9/26/2024 11:57:33 8.2 427 147 77.5 21 9/26/2024 11:58:33 8.2 429 149 78.4 Avg. 8.2 429.3 146.4 68.9 Emissions Science, Inc. 3. Grand Junction, CO 81507Phone: 970.628.4849 Date : 9/23/2024 Analyzer Model: Testo 350 Analyst : Andrew Edwards Analyzer Serial #: 3289 Gas Species Analyzer Range Calibration Gas Concentration (ppm or %) Sensor Response ppm CO / NO / NO2 % O2 Absolute Difference Percent of Span Linearity Valid (Yes/No) NO2 ppm Zero 0.0 0 0.00 0.00 YES Mid 78.66 78.8 0.14 0.10 YES Span 145.6 145.9 0.30 0.21 YES NO ppm Zero 0.0 0 0.00 0.00 YES Mid 59.08 60 0.92 0.77 YES Span 120.0 121 1.00 0.83 YES Zero 0.0 0 0.00 0.00 YES Mid 120.0 121 1.00 0.42 YES Span 235.3 236 0.70 0.30 YES Zero 0.0 0 0.00 0.00 YES Mid 235.3 236 0.70 0.13 YES Span 554.2 555 0.80 0.14 YES Zero 0.0 0 0.00 0.00 YES Mid 554.2 555 0.80 0.08 YES Span 1065.0 1067 2.00 0.19 YES CO ppm Zero 0.0 0 0.00 0.00 YES Mid 27.75 28 0.25 0.43 YES Span 57.58 58 0.42 0.73 YES Zero 0.0 0 0.00 0.00 YES Mid 57.58 58 0.42 0.35 YES Span 121.1 121 0.10 0.08 YES Zero 0.0 0 0.00 0.00 YES Mid 121.1 121 0.10 0.04 YES Span 241.7 243 1.30 0.54 YES Zero 0.0 0 0.00 0.00 YES Mid 241.7 243 1.30 0.27 YES Span 488.8 489 0.20 0.04 YES Zero 0.0 0 0.00 0.00 YES Mid 488.8 489 0.20 0.02 YES Span 1023.0 1023 0.00 0.00 YES O2 %Zero 0.0 0.00 0.00 0.00 YES Mid 10.50 10.50 0.00 0.00 YES Span 20.90 21.00 0.10 0.48 YES Appendix A Linearity Check Data Sheet LINEARITY CHECK Emissions Science, Inc. 4.Grand Junction, CO 81507Phone: 970.628.4849 Analyst: Andrew Edwards Analyzer Serial # 3289 Date:09/23/24 Date:09/23/24 Date:09/23/24 NO Gas Span ppm NO2 Gas Span ppm CO Gas Span ppm 1065 145.6 1023 Time (Min.) Analyzer ppm Time (Min.) Analyzer ppm Time (Min.) Analyzer ppm 0 0 0 0.0 0 0 1 1065 1 145.8 1 1023 2 1065 2 145.7 2 1023 3 1064 3 145.6 3 1023 4 1064 4 145.5 4 1022 5 1064 5 145.4 5 1022 6 1063 6 145.4 6 1022 7 1063 7 145.4 7 1021 8 1062 8 145.3 8 1021 9 1062 9 145.3 9 1020 10 1061 10 145.2 10 1020 11 1061 11 145.3 11 1019 12 1061 12 145.2 12 1019 13 1060 13 145.3 13 1019 14 1060 14 145.2 14 1018 15 1060 15 145.1 15 1018 16 1059 16 145.1 16 1017 17 1059 17 144.9 17 18 18 18 19 19 19 20 20 20 21 21 21 22 22 22 23 23 23 24 24 24 25 25 25 26 26 26 27 27 27 28 28 28 29 29 29 30 30 30 31 31 31 32 32 32 33 33 33 34 34 34 35 35 35 36 36 36 37 37 37 30 Minute Sensor Test 30 Minute Sensor Test 30 Minute Sensor Test Maximum ppm Maximum ppm Maximum ppm Minimum ppm Minimum ppm Minimum ppm Max. Deviation % Max. Deviation % Max. Deviation % 15 Minute Sensor Test 15 Minute Sensor Test 15 Minute Sensor Test Maximum ppm 1065 Maximum ppm 145.8 Maximum ppm 1023 Minimum ppm 1059 Minimum ppm 144.9 Minimum ppm 1017 Max. Deviation % 0.56 Max. Deviation % 0.62 Max. Deviation % 0.59 Stability Time 1 Stability Time 1 Stability Time 1 Stability Valid?Yes Stability Valid?Yes Stability Valid?Yes Appendix B Sensor Stability Test Maximum Deviation = 100*(Max. Conc.- Min. Conc.)/ Span Gas Conc. Emissions Science, Inc. 5.Grand Junction, CO 81507Phone: 970.628.4849 Appendix C Calibration Error Check Data Sheet Client: Urban Oil & Gas, LLC Facility : Clawson Spring C.S. Source ID : C-103 Date : 9/26/2024 Analyst : Andrew Edwards Permit # : DAQE 634-01 Analyzer Manufacturer/Model # : TESTO 3289 PRETEST CALIBRATION ERROR CHECK A B (A-B) (A-B)/A*(100) Pump Flow Rate (lpm) Calibration Gas Concentration (ppm) Analyzer Reading (ppm) Absolute Difference Percent of Span Difference Calibration Valid (YES or NO) Response Time (min.) NO Zero 3.0 0 0 0 0.0 YES 1 Span 3.0 235.3 236 0.7 0.3 YES 1 NO2 Zero 3.0 0 0 0 0.0 YES 1 Span 3.0 78.66 79.4 0.74 0.9 YES 1 CO Zero 3.0 0 0 0 0.0 YES 1 Span 3.0 488.8 488 0.8 0.2 YES 1 O2 Zero 3.0 0.0 0.0 0 0.0 YES 1 Span 3.0 20.95 20.97 0.02 0.1 YES 1 Pretest Calibration NO Cell Temperature (F):60 POST TEST CALIBRATION ERROR CHECK Interference A B (A-B) (A-B)/A*(100) Check Pump Flow Rate (lpm) Calibration Gas Concentration (ppm) Analyzer Reading (ppm) Absolute Difference Percent of Span Difference Calibration Valid (YES or NO) Avgeraged Pre / Post Test Analyzer Readings CO/NO Monitor Response (ppm) NO Zero 3.0 0 0 0 0.0 YES 0 0 Span 3.0 235.3 236 0.7 0.3 YES 236 NO2 Zero 3.0 0 0 0 0.0 YES 0 Span 3.0 78.66 79.9 1.24 1.6 YES 79.65 CO Zero 3.0 0 0 0 0.0 YES 0 0 Span 3.0 488.8 483 5.8 1.2 YES 485.5 O2 Zero 3.0 0.0 0.0 0 0.0 YES 0 Span 3.0 20.95 20.97 0.02 0.1 YES 20.97 Post Test Calibration NO Cell Temperature (F):60 CO Interference Response (Ico,%) 0.00 NO Interference Response (Ino,%) 0.00 Emissions Science, Inc. 6.Grand Junction, CO 81507Phone: 970.628.4849 Appendix D: Detailed Reciprocating Engine Test Results Client :Urban Oil & Gas, LLC Date : 9/26/24 Facility Clawson Spring C.S. Source #: C-103 Source Manufacturer & Model # : Caterpillar 3516 TALE Site-Rated Horsepower : 1206 Source Serial # : 4EK01860 Type of Emission Control : A/F "Y" SCO "N" Analyst : Andrew Edwards Analyzer ID# : TESTO 3289 Analyzer Manufacturer/Model # : Testo 350 Operating Conditions Source operating at 90% or greater site rated horsepower during test? NO Engine RPM Suction Pressure (PSI) Discharge Pressure (PSI) Daily Volume (MMCFD) Engine Fuel Consumption (MMBtu/hr) Fuel Heat Content (Btu/scf) Brake Specific Fuel Consumption (Btu/hp-hr) Engine Tested Horsepower Engine Runtime Hours 1200 3 589 2.01 5.61 1020 6608 849 58153 Test Results Test Start Time : 11:38:33 NO Cell Temp. (F) after 1/3 of test : 60 Test End Time : 11:58:33 NO Cell Temp. (F) after 2/3 of test : 60 NOx (NO+NO2) Avg. Tested NO ppm Corrected NO ppm Avg. Tested NO2 ppm Corrected NO2 ppm Corrected NOx ppm Tested ppmvd @ 7.9% O2 Tested lb/hr Allowable ppmvd @ 7.9% O2 Allowable lb/hr 146.4 146.0 68.9 68.0 214.0 219.52 2.06 282.00 5.15 O2 CO Avg. Tested O2 % Corrected O2 % Avg. Tested CO ppm Corrected CO ppm Tested ppmvd @ 7.9% O2 Tested lb/hr Allowable ppmvd @ 7.9% O2 Allowable lb/hr 8.2 8.2 429.3 432.3 443.42 2.53 498.00 5.51 I certify to the best of my knowledge the test results are accurate and representative of the emissions from this source. Print Name Signature (Responsible Company Official) (ESI Analyst) Name: Andrew Edwards 0 100 200 300 400 500 123456789101112131415161718192021 Co n c e n t r a t i o n s Minutes Graphical Format % O2 ppm CO ppm NO ppm NO2 Emissions Science, Inc. 7. Grand Junction, CO 81507Phone: 970.628.4849 Caterpillar Supplied Information Load 100% 75% 50% Engine Horsepower 1206 905 603 Fuel Consumption 7401 7657 8128 Btu/bhp-hr Intake Manifold Pressure 19.9 12.6 4.8 psig Source: C-103 Number of Compression Stages 3 Suction Pressure 3 psi Discharge Pressure 589 psi Volume of Gas Moved 2.01 MMscfd F Factor 1.1 Brake Horsepower 849.0 hp <site rating of 1206 hp Intake Manifold Pressure psig Brake Horsepower 408.6 hp Higher Heating Value 1004 Btu/scf Measured Fuel Consumption scf/hr Horsepower Default Fuel Consumption 9400 Btu/hp-hr 0.0 Provided by ESI 8300 Btu/hp-hr 0.0 Interpolated from Cat Data #DIV/0! Btu/hp-hr #DIV/0! User defined entries Method 3 - Wyoming Portable Analyzer Protocol Hp Calculations Method 1 - GPSA Handbook Equation 13-4 Catperpillar 3516LE Horsepower Calculation Methods Method 2 - Interpolation of Intake Manifold Pressure Urban Oil & Gas, LLC Caterpillar 3516 TALE Permit or AIRS #: DAQE 634-01 Clawson Spring C.S. Source ID: C-104 Serial #: 4EK03031 Test Date: 9/26/2024 Site Rated HP: 1206 E.S.I Analyst Andrew Edwards Source ID: Reportable Units Tested Results: NOx Allowable Limits: NOx Tested Results: CO Allowable Limits: CO C-104 ppmvd @ 7.9% O2 252.00 282.00 382.59 498.00 Lb/Hr 2.58 5.15 2.38 5.51 Source Compliant?YES YES Emissions Science, Inc. performed an emissions test for this unit using a portable emissions analyzer equipped with electrochemical sensors. The sensors used for the test were found to be within calibration requirements and properly tested for Q/A & Q/C in accordance with the Portable Analyzer Guidelines published by the Utah Department of Environmental Quailty, Air Quailty Divison. A twenty-one minute test was performed on this source under normal load conditions for this site. Emission rates for NOx and CO were calculated using EPA Method 19 and based on stack gas concentrations, percent oxygen and best available fuel usage or default fuel efficiency values where no fuel meter was present. Emissions Science, Inc www.emissions-science.com 1. Grand Junction, CO 81507Phone: 970.628.4849 Detailed Source Test Data Client:Urban Oil & Gas, LLC Engine Type: Facility:Clawson Spring C.S.Source ID: Control Equipment.A/F "Y" SCO "N"Site Rated HP: Permit or AIRS #:DAQE 634-01 Serial #: Test Date:9/26/2024 Analyst: Job Code:UOG-24-132 Analyzer ID: Engine Operations Data:Fuel Calculation Data: RPM 1202 Suction Pressure (PSI)3.5 Metered Fuel Usage: Discharge Pressure (PSI)580 Fuel Use (SCF/D)144000 Manifold Pressure (PSI)19.0 Fuel Use (SCF/H)6000.0 Manifold Temperature (F)129.2 Fuel Value (BTU/SCF)1020 Unit Volume (MMCF/D)2.04 Fuel Use (MMBTU/HR)6.12 Fuel Value (BTU/SCF)1020 F's of D (SCF/MMBTU)8710 Fuel Use Based on BSFC Engine Operation Hours 69210 BHP 813.50 Observed Stack O2 %7.9 Efficiency (BTU/BHP-HR) Engine Timing (BTDC) °26.0 Fuel Use (MMBTU/HR)0.000 Site Conditions Data Fuel Use For Calculations (MMBTU/HR)6.12 Barometric Pressure ("Hg)23.16 Relative Humidity (%)21 Emission Controls Data Ambient Temperature (F)73 Catalyst Temperature Ambient Temperature (C)22.8 Inlet Temperature (F) °N/A Site Elevation ('ASL)6716 Outlet Temperature (F) °N/A Portable Analyzer Temperature Catalyst Differential Pressure NO Temperature (F) ° 1/3 of Test 61 Inlet / Outlet Pressure ("H2O)N/A NO Temperature (F) ° 2/3 of Test 60 ∆ P ("H2O)N/A HP Calculations AFR NOx PPM Set. / Reading 240.0 / 220.4 Fuel Use & BSFC Emissions Results Fuel Use (MMBTU/Hr)6.12 BSFC (BTU/BHP-Hr)CO (LB/MMBTU)0.39 BHP NOx (LB/MMBTU)0.42 CO (LB/HR)2.38 Percent Load HP NOx (LB/HR)2.58 Site Rated HP 1156.00 CO (PPMVD @ 7.9% O2)382.59 % Load 70.4 NOx (PPMVD @ 7.9% O2)252.00 BHP 813.50 CO (GM/BHP-HR) {1.87}1.329 NOx (GM/BHP-HR) {1.74}1.438 Generator HP Kilo-Watt Produced CORRECTED VALUES 3-Phase (Power Factor .80) 0.00 O2 (%)7.9 Single Phase 0.00 CO (ppm)383.3 BHP 0.00 NO (ppm)169.3 NO2 (ppm)83.2 Trapped or Calculated NOx (ppm)252.5 Measured BHP BHP Used for Test 814 BSFC (BTU/BHP-HR) 7523 Andrew Edwards TESTO 3289 Caterpillar 3516 TALE C-104 1206 4EK03031 Emissions Science, Inc. 2.Grand Junction CO 81507Phone: 970.628.4849 Unit ID: C-104 Date: 09/26/24 Data Log File Minute: Date TIME % O2 ppm CO ppm NO ppm NO2 1 9/26/2024 10:47:23 7.9 378 158 78.6 2 9/26/2024 10:48:23 7.9 381 165 78.6 3 9/26/2024 10:49:23 7.9 385 178 78.9 4 9/26/2024 10:50:23 7.9 380 159 76.2 5 9/26/2024 10:51:23 7.8 386 192 82.7 6 9/26/2024 10:52:23 7.9 381 166 79.5 7 9/26/2024 10:53:23 7.9 379 168 81.3 8 9/26/2024 10:54:23 7.8 381 171 83.2 9 9/26/2024 10:55:23 7.9 384 170 82.9 10 9/26/2024 10:56:23 7.8 383 174 84.4 11 9/26/2024 10:57:23 7.9 382 162 81.8 12 9/26/2024 10:58:23 7.8 390 200 90.1 13 9/26/2024 10:59:23 7.8 381 181 88.6 14 9/26/2024 11:00:23 7.9 379 168 86.7 15 9/26/2024 11:01:23 7.9 377 161 85.7 16 9/26/2024 11:02:23 7.9 377 165 86.4 17 9/26/2024 11:03:23 7.9 378 168 87.2 18 9/26/2024 11:04:23 7.9 379 162 85.5 19 9/26/2024 11:05:23 7.9 380 173 87.9 20 9/26/2024 11:06:23 7.9 379 169 87.3 21 9/26/2024 11:07:23 7.9 376 156 84.4 Avg. 7.9 380.8 169.8 83.7 Emissions Science, Inc. 3. Grand Junction, CO 81507Phone: 970.628.4849 Date : 9/23/2024 Analyzer Model: Testo 350 Analyst : Andrew Edwards Analyzer Serial #: 3289 Gas Species Analyzer Range Calibration Gas Concentration (ppm or %) Sensor Response ppm CO / NO / NO2 % O2 Absolute Difference Percent of Span Linearity Valid (Yes/No) NO2 ppm Zero 0.0 0 0.00 0.00 YES Mid 78.66 78.8 0.14 0.10 YES Span 145.6 145.9 0.30 0.21 YES NO ppm Zero 0.0 0 0.00 0.00 YES Mid 59.08 60 0.92 0.77 YES Span 120.0 121 1.00 0.83 YES Zero 0.0 0 0.00 0.00 YES Mid 120.0 121 1.00 0.42 YES Span 235.3 236 0.70 0.30 YES Zero 0.0 0 0.00 0.00 YES Mid 235.3 236 0.70 0.13 YES Span 554.2 555 0.80 0.14 YES Zero 0.0 0 0.00 0.00 YES Mid 554.2 555 0.80 0.08 YES Span 1065.0 1067 2.00 0.19 YES CO ppm Zero 0.0 0 0.00 0.00 YES Mid 27.75 28 0.25 0.43 YES Span 57.58 58 0.42 0.73 YES Zero 0.0 0 0.00 0.00 YES Mid 57.58 58 0.42 0.35 YES Span 121.1 121 0.10 0.08 YES Zero 0.0 0 0.00 0.00 YES Mid 121.1 121 0.10 0.04 YES Span 241.7 243 1.30 0.54 YES Zero 0.0 0 0.00 0.00 YES Mid 241.7 243 1.30 0.27 YES Span 488.8 489 0.20 0.04 YES Zero 0.0 0 0.00 0.00 YES Mid 488.8 489 0.20 0.02 YES Span 1023.0 1023 0.00 0.00 YES O2 %Zero 0.0 0.00 0.00 0.00 YES Mid 10.50 10.50 0.00 0.00 YES Span 20.90 21.00 0.10 0.48 YES Appendix A Linearity Check Data Sheet LINEARITY CHECK Emissions Science, Inc. 4.Grand Junction, CO 81507Phone: 970.628.4849 Analyst: Andrew Edwards Analyzer Serial #3289 Date:09/23/24 Date:09/23/24 Date:09/23/24 NO Gas Span ppm NO2 Gas Span ppm CO Gas Span ppm 1065 145.6 1023 Time (Min.) Analyzer ppm Time (Min.) Analyzer ppm Time (Min.) Analyzer ppm 0 0 0 0.0 0 0 1 1065 1 145.8 1 1023 2 1065 2 145.7 2 1023 3 1064 3 145.6 3 1023 4 1064 4 145.5 4 1022 5 1064 5 145.4 5 1022 6 1063 6 145.4 6 1022 7 1063 7 145.4 7 1021 8 1062 8 145.3 8 1021 9 1062 9 145.3 9 1020 10 1061 10 145.2 10 1020 11 1061 11 145.3 11 1019 12 1061 12 145.2 12 1019 13 1060 13 145.3 13 1019 14 1060 14 145.2 14 1018 15 1060 15 145.1 15 1018 16 1059 16 145.1 16 1017 17 1059 17 144.9 17 18 18 18 19 19 19 20 20 20 21 21 21 22 22 22 23 23 23 24 24 24 25 25 25 26 26 26 27 27 27 28 28 28 29 29 29 30 30 30 31 31 31 32 32 32 33 33 33 34 34 34 35 35 35 36 36 36 37 37 37 30 Minute Sensor Test 30 Minute Sensor Test 30 Minute Sensor Test Maximum ppm Maximum ppm Maximum ppm Minimum ppm Minimum ppm Minimum ppm Max. Deviation % Max. Deviation % Max. Deviation % 15 Minute Sensor Test 15 Minute Sensor Test 15 Minute Sensor Test Maximum ppm 1065 Maximum ppm 145.8 Maximum ppm 1023 Minimum ppm 1059 Minimum ppm 144.9 Minimum ppm 1017 Max. Deviation % 0.56 Max. Deviation % 0.62 Max. Deviation % 0.59 Stability Time 1 Stability Time 1 Stability Time 1 Stability Valid?Yes Stability Valid?Yes Stability Valid?Yes Appendix B Sensor Stability Test Maximum Deviation = 100*(Max. Conc.- Min. Conc.)/ Span Gas Conc. Emissions Science, Inc. 5.Grand Junction, CO 81507Phone: 970.628.4849 Appendix C Calibration Error Check Data Sheet Client: Urban Oil & Gas, LLC Facility : Clawson Spring C.S. Source ID : C-104 Date : 9/26/2024 Analyst : Andrew Edwards Permit # : DAQE 634-01 Analyzer Manufacturer/Model # : TESTO 3289 PRETEST CALIBRATION ERROR CHECK A B (A-B) (A-B)/A*(100) Pump Flow Rate (lpm) Calibration Gas Concentration (ppm) Analyzer Reading (ppm) Absolute Difference Percent of Span Difference Calibration Valid (YES or NO) Response Time (min.) NO Zero 3.0 0 0 0 0.0 YES 1 Span 3.0 235.3 236 0.7 0.3 YES 1 NO2 Zero 3.0 0 0 0 0.0 YES 1 Span 3.0 78.66 78.9 0.24 0.3 YES 1 CO Zero 3.0 0 0 0 0.0 YES 1 Span 3.0 488.8 489 0.2 0.0 YES 1 O2 Zero 3.0 0.0 0.0 0 0.0 YES 1 Span 3.0 20.95 20.95 0 0.0 YES 1 Pretest Calibration NO Cell Temperature (F):61 POST TEST CALIBRATION ERROR CHECK Interference A B (A-B) (A-B)/A*(100) Check Pump Flow Rate (lpm) Calibration Gas Concentration (ppm) Analyzer Reading (ppm) Absolute Difference Percent of Span Difference Calibration Valid (YES or NO) Avgeraged Pre / Post Test Analyzer Readings CO/NO Monitor Response (ppm) NO Zero 3.0 0 0 0 0.0 YES 0 0 Span 3.0 235.3 236 0.7 0.3 YES 236 NO2 Zero 3.0 0 0 0 0.0 YES 0 Span 3.0 78.66 79.4 0.74 0.9 YES 79.15 CO Zero 3.0 0 0 0 0.0 YES 0 0 Span 3.0 488.8 482 6.8 1.4 YES 485.5 O2 Zero 3.0 0.0 0.0 0 0.0 YES 0 Span 3.0 20.95 20.97 0.02 0.1 YES 20.96 Post Test Calibration NO Cell Temperature (F):60 CO Interference Response (Ico,%) 0.00 NO Interference Response (Ino,%) 0.00 Emissions Science, Inc. 6.Grand Junction, CO 81507Phone: 970.628.4849 Appendix D: Detailed Reciprocating Engine Test Results Client :Urban Oil & Gas, LLC Date : 9/26/24 Facility Clawson Spring C.S. Source #: C-104 Source Manufacturer & Model # : Caterpillar 3516 TALE Site-Rated Horsepower : 1206 Source Serial # : 4EK03031 Type of Emission Control : A/F "Y" SCO "N" Analyst : Andrew Edwards Analyzer ID# : TESTO 3289 Analyzer Manufacturer/Model # : Testo 350 Operating Conditions Source operating at 90% or greater site rated horsepower during test? NO Engine RPM Suction Pressure (PSI) Discharge Pressure (PSI) Daily Volume (MMCFD) Engine Fuel Consumption (MMBtu/hr) Fuel Heat Content (Btu/scf) Brake Specific Fuel Consumption (Btu/hp-hr) Engine Tested Horsepower Engine Runtime Hours 1202 3.5 580 2.04 6.12 1020 7523 814 69210 Test Results Test Start Time : 10:47:23 NO Cell Temp. (F) after 1/3 of test : 61 Test End Time : 11:07:23 NO Cell Temp. (F) after 2/3 of test : 60 NOx (NO+NO2) Avg. Tested NO ppm Corrected NO ppm Avg. Tested NO2 ppm Corrected NO2 ppm Corrected NOx ppm Tested ppmvd @ 7.9% O2 Tested lb/hr Allowable ppmvd @ 7.9% O2 Allowable lb/hr 169.8 169.3 83.7 83.2 252.5 252.00 2.58 282.00 5.15 O2 CO Avg. Tested O2 % Corrected O2 % Avg. Tested CO ppm Corrected CO ppm Tested ppmvd @ 7.9% O2 Tested lb/hr Allowable ppmvd @ 7.9% O2 Allowable lb/hr 7.9 7.9 380.8 383.3 382.59 2.38 498.00 5.51 I certify to the best of my knowledge the test results are accurate and representative of the emissions from this source. Print Name Signature (Responsible Company Official) (ESI Analyst) Name: Andrew Edwards 0 100 200 300 400 500 123456789101112131415161718192021 Co n c e n t r a t i o n s Minutes Graphical Format % O2 ppm CO ppm NO ppm NO2 Emissions Science, Inc. 7. Grand Junction, CO 81507Phone: 970.628.4849 Caterpillar Supplied Information Load 100% 75% 50% Engine Horsepower 1206 905 603 Fuel Consumption 7401 7657 8128 Btu/bhp-hr Intake Manifold Pressure 19.9 12.6 4.8 psig Source: C-104 Number of Compression Stages 3 Suction Pressure 3.5 psi Discharge Pressure 580 psi Volume of Gas Moved 2.04 MMscfd F Factor 1.1 Brake Horsepower 813.5 hp <site rating of 1206 hp Intake Manifold Pressure psig Brake Horsepower 408.6 hp Higher Heating Value 1004 Btu/scf Measured Fuel Consumption scf/hr Horsepower Default Fuel Consumption 9400 Btu/hp-hr 0.0 Provided by ESI 8300 Btu/hp-hr 0.0 Interpolated from Cat Data #DIV/0! Btu/hp-hr #DIV/0! User defined entries Method 3 - Wyoming Portable Analyzer Protocol Hp Calculations Method 1 - GPSA Handbook Equation 13-4 Catperpillar 3516LE Horsepower Calculation Methods Method 2 - Interpolation of Intake Manifold Pressure Urban Oil C-101 2024 NOx and CO rev Reference Methods 2, 3A, 6C, 7E, 10, & 19 Source Information Company Name Urban Oil and Gas, Clawson Springs CS Company Contact:Kirt Rasmussen Contact Phone No.435-820-9801 Stack Designation:C-101 Test & Review Dates Test Date:9/26/2024 Review Date: 11/18/2024 Observer:Robert Sirrine Reviewer:Robert Sirrine Emission Limits Emission Rates SO2 NOX CO SO2 NOX CO lbs./kW-hr 1.74 1.87 1.336 1.558 lbs./hr. 5.15 5.5 2.461 2.870 ppm 282.0 498.00 254.590 487.630 Percent %O2 Correction as a whole #7.90 7.90 Test Information Heat Input Equivalent Diameter (in.)As ft^2 Y Dl H @ Cp Pbar Pq (static) fuel flow rate (Btu/hr.) Heat Input (Btu/hr.) FALSE 0.9960 1.717 0.84 23.12 -0.95 Contractor Information Contact: Cheyney Guymon Contracting Company: Montrose Air Quality Services Address: 6823 S 3600 W Spanish Fork, Utah Phone No.: Project No.: 8710 Division of Air Quality Instrumental Reference Methods - Gaseous Measurements Method 19 - F factors for Coal, Oil, and Gas Fd Fw Fc scf/MMBtu scf/MMBtu scf/MMBtu Diluent F factor used O2 CO2Anthrocite 2 Bituminous Lignite Natural Propane Butane 10100 COAL OIL GAS 9780 9860 9190 8710 8710 8710 10540 10640 11950 320 10610 10200 10390 1970 1800 1910 1420 1040 1190 1250 Wet CEM Correct For O2 CO2 Interference w/CO Yes Yes Yes Urban Oil C-101 2024 NOx and CO rev Division of Air Quality NSPS Relative Accuracy Performance Specification Test - CEMS Certification Urban Oil and Gas, Clawson Springs CS C-101 Average Emission Dry SO2 NOX CO g/hp-hr 1.336 1.558 Average % concentration lbs./hr.2.461 2.870 CO2 O2 ppm corrected for %O2 254.59 487.63 8.10 Run 1 Enter O2 or CO2 Dry SO2 NOX CO CO2 O2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)4.2583E-01 4.9648E-01 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 2.994E-05 3.491E-05 lbs./hr.2.461 2.870 6.50 8.10 ppm corrected for %O2 254.59 487.63 8.10 Run 2 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr.6.60 9.60 ppm corrected for %O2 Raw Value Run 3 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr.6.60 9.60 ppm corrected for %O2 Raw Value Run 4 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr. ppm corrected for %O2 Raw Value Corrected For Cal. Drift Raw Value Corrected For Cal. Drift Corrected For Cal. Drift Corrected For Cal. Drift O2 CO2 Clear lbs./MMBTU Urban Oil C-101 2024 NOx and CO rev Calibration Error Test Test Date September 26, 2024 O2 CS - Cal. Span 20.90 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.00% Passed Cal. Mid-level 10.50 10.50 0.00 0.00% Passed Cal. High-level 20.90 21.00 0.10 0.48% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of CS - Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 50.24% 100% of Cal. Span High-level 100.00% Test Date CO2 CS - Cal. Span Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Test Date SO2 CS - Cal. Span Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Test Date September 26, 2024 NOx CS - Cal. Span 632.86 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.000% Passed Cal. Mid-level 313.96 314.80 0.84 0.133% Passed Cal. High-level 632.86 633.80 0.94 0.149% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 49.61% 100% of Cal. Span High-level 100.00% Test Date September 26, 2024 CO 5.51 CS - Cal. Span 1,023.00 498 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.000% Passed Cal. Mid-level 488.80 489.00 0.20 0.020% Passed Cal. High-level 1,023.00 1,023.00 0.00 0.000% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 47.78% 100% of Cal. Span High-level 100.00% Urban Oil C-101 2024 NOx and CO rev Division of Air Quality Stack Test Review of Urban Oil and Gas, Clawson Springs CS SO2 NOX CO CO2 O2 C-101 CS Calibration Span 632.86 1023.00 20.90Units ppm ppm ppm % % Unprotected CV - Cylinder Value:SO2 NOX CO CO2 O2Low-Level 0.00 0.00 0.00 Mid-Level 313.96 488.80 10.50 High-Level 632.86 1023.00 20.90 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 49.6% 47.8% 50.2% 100% of Cal. Span 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CDir CMA 313.96 488.80 20.90 Calibration Error Test Cs - Measured Concentration SO2 NOX CO CO2 O2Low-Level 0.00 0.00 0.00 Mid-Level 314.80 489.00 10.50 High-Level 633.80 1023.00 21.00 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 314.80 489.00 21.00 Low-Level 0.00% 0.00% 0.00% ppmdv Difference 0 0 0 Status Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.13% 0.02% 0.00% ppmdv Difference 0.84 0.2 0 Status Passed Cal. Passed Cal.Passed Cal. High-Level 0.15% 0.00% 0.48% ppmdv Difference 0.94 0 0.1 Status Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.00% 0.00% TRUE 0.00%± 5% of Span Difference TRUE 0 0 TRUE 0 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 315.90 491.00 20.97 SBi - Up-Scale Bias TRUE 0.17% 0.20% TRUE 0.14% Difference TRUE 1.10 2.00 TRUE 0.03 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:9/26/2024 SO2 SO2 NOX CO CO2 O2 NOX 250.7 481.80 8.1 CO 0.0% 39.6% 47.1% 0.0% 38.8%CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.00% 0.00% TRUE 0.00%± 5% of Span Difference TRUE 0.0 0.0 TRUE 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 312.10 490.00 20.98 SBi - Up-Scale Bias TRUE 0.43% 0.10% TRUE 0.10% Difference TRUE 2.7 1.0 TRUE 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.00% 0.00% TRUE 0.00% Drift Difference TRUE 0.0 0.0 TRUE 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Up-scale Gas Drift TRUE 0.25% 0.10% TRUE 0.05% Difference TRUE 3.8 1.0 TRUE 0.0Pass or Re-Calibrate Pass Pass Pass C-101 Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms FALSE 23.12 -0.95 23.05 8.10 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws #VALUE! 0.9960 0.84 0.1700 0.999 Load - Megawatts Avg. √∆P's Vs (ft/sec.)Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 1.0000 #VALUE! #VALUE! 5.780034 Enert >X 3D Pito #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 1.00 1.000 2 1.00 1.000 3 4 5 6 Sum 7 8 9 10 11 12 13 1415 16 17 1819 20 21 2223 24 NOTEThese cells scans for the appropriate Cir. gas after the Cm If this scan is incorrect change the Cdir to the correct gas value. CO Calibration Gas Urban Oil C-101 2024 NOx and CO rev Division of Air Quality Stack Test Review of Urban Oil and Gas, Clawson Springs CS SO2 NOX CO CO2 O2 C-101 CS Calibration Span 632.86 1023.00 20.90 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2Low-Level 0.00 0.00 0.00 Mid-Level 313.96 488.80 10.50High-Level 632.86 1023.00 20.90 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 49.6% 47.8% 50.2% 100% of Cal. Span 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 313.96 488.80 20.90 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2Low-Level 0.00 0.00 0.00 Mid-Level 314.80 489.00 10.50 High-Level 633.80 1023.00 21.00 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 314.80 489.00 21.00 Low-Level 0.00% 0.00% 0.00% ppmdv Difference 0 0 0 Status Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.13% 0.02% 0.00% ppmdv Difference 0.84 0.2 0 Status Passed Cal. Passed Cal.Passed Cal. High-Level 0.15% 0.00% 0.48% ppmdv Difference 0.94 0 0.1 Status Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.00% 0.00% TRUE 0.00%± 5% of Span Difference TRUE 0 0 TRUE 0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 312.10 490.00 20.98 SBi - Up-Scale Bias TRUE 0.43% 0.10% TRUE 0.10% Difference TRUE 2.7 1 TRUE 0.02 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:9/26/2024 SO2 SO2 NOX CO CO2 O2 NOXCO 0.0% 0.0% 0.0% 0.0% 0.0% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level System Bias. SBi - Zero Bias TRUE TRUE TRUE TRUE TRUE ± 5% of Span Difference TRUE TRUE TRUE TRUE TRUE Pass or Invalid Run CM - Up-scale Gas SBi - Up-Scale Bias TRUE TRUE TRUE TRUE TRUE Difference TRUE TRUE TRUE TRUE TRUE Pass or Invalid Run Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE TRUE TRUE TRUE TRUE Response Spec. Difference TRUE TRUE TRUE TRUE TRUE 3% of Span Pass or Re-Calibrate Up-scale Gas Drift TRUE TRUE TRUE TRUE TRUE Difference TRUE TRUE TRUE TRUE TRUEPass or Re-Calibrate C-101 Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms FALSE 23.12 -0.95 23.05 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws 0.9960 0.84 0.999 Load - Megawatts Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High #DIV/0! #DIV/0!Enert >X 3D Pito #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 Sum 78 9 1011 12 1314 15 16 17 18 19 20 2122 23 24 Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog Failed Bias Dialog Urban Oil C-101 2024 NOx and CO rev Division of Air Quality Stack Test Review of Urban Oil and Gas, Clawson Springs CS SO2 NOX CO CO2 O2 C-101 CS Calibration Span 632.86 1023.00 20.90 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2Low-Level 0.00 0.00 0.00 Mid-Level 313.96 488.80 10.50High-Level 632.86 1023.00 20.90 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 49.6% 47.8% 50.2% 100% of Cal. Span 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2Low-Level 0.00 0.00 0.00 Mid-Level 314.80 489.00 10.50 High-Level 633.80 1023.00 21.00 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 Low-Level 0.00% 0.00% 0.00% ppmv Difference 0 0 0 Status Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.13% 0.02% 0.00% ppmv Difference 0.84 0.2 0 Status Passed Cal. Passed Cal.Passed Cal. High-Level 0.15% 0.00% 0.48% ppmv Difference 0.94 0 0.1 Status Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level System Bias. SBi - Zero Bias TRUE TRUE TRUE TRUE TRUE ± 5% of Span Difference TRUE TRUE TRUE TRUE TRUE Pass or Invalid Run CM - Up-scale Gas SBi - Up-Scale Bias TRUE TRUE TRUE TRUE TRUE Difference TRUE TRUE TRUE TRUE TRUE Pass or Invalid Run Raw Test Data Time Start Stop Test Date:9/26/2024 SO2 SO2 NOX CO CO2 O2 NOXCO 0.0% 0.0% 0.0% 0.0% 0.0% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level System Bias. SBi - Zero Bias TRUE TRUE TRUE TRUE TRUE ± 5% of Span Difference TRUE TRUE TRUE TRUE TRUE Pass or Invalid Run CM - Up-scale Gas SBi - Up-Scale Bias TRUE TRUE TRUE TRUE TRUE Difference TRUE TRUE TRUE TRUE TRUE Pass or Invalid Run Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE TRUE TRUE TRUE TRUE Response Spec. Difference TRUE TRUE TRUE TRUE TRUE 3% of Span Pass or Re-Calibrate Up-scale Gas Drift TRUE TRUE TRUE TRUE TRUE Difference TRUE TRUE TRUE TRUE TRUEPass or Re-Calibrate C-101 Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms FALSE 23.12 -0.95 23.05 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws 0.9960 0.84 0.999 Load - Megawatts Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High #DIV/0! #DIV/0!Enert >X 3D Pito #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 Sum 78 9 1011 12 1314 15 16 17 18 19 20 2122 23 24 Urban Oil C-103 2024 NOx and CO rev Reference Methods 2, 3A, 6C, 7E, 10, & 19 Source Information Company Name Urban Oil and Gas, Clawson Springs CS Company Contact:Kirt Rasmussen Contact Phone No.435-820-9801 Stack Designation:C-103 Test & Review Dates Test Date:9/26/2024 Review Date: 11/19/2024 Observer:Robert Sirrine Reviewer:Robert Sirrine Emission Limits Emission Rates SO2 NOX CO SO2 NOX CO lbs./kW-hr 1.74 1.87 1.101 1.352 lbs./hr. 5.15 5.5 2.060 2.531 ppm 282.0 498.00 219.550 443.130 Percent %O2 Correction as a whole #7.90 7.90 Test Information Heat Input Equivalent Diameter (in.)As ft^2 Y Dl H @ Cp Pbar Pq (static) fuel flow rate (Btu/hr.) Heat Input (Btu/hr.) FALSE Contractor Information Contact: Cheyney Guymon Contracting Company: Montrose Air Quality Services Address: 6823 S 3600 W Spanish Fork, Utah Phone No.: Project No.: 8710 Division of Air Quality Instrumental Reference Methods - Gaseous Measurements Method 19 - F factors for Coal, Oil, and Gas Fd Fw Fc scf/MMBtu scf/MMBtu scf/MMBtu Diluent F factor used O2 CO2Anthrocite 2 Bituminous Lignite Natural Propane Butane 10100 COAL OIL GAS 9780 9860 9190 8710 8710 8710 10540 10640 11950 320 10610 10200 10390 1970 1800 1910 1420 1040 1190 1250 Wet CEM Correct For O2 CO2 Interference w/CO Yes Yes Yes Urban Oil C-103 2024 NOx and CO rev Division of Air Quality NSPS Relative Accuracy Performance Specification Test - CEMS Certification Urban Oil and Gas, Clawson Springs CS C-103 Average Emission Dry SO2 NOX CO g/hp-hr 1.10 1.35 Average % concentration lbs./hr.2.06 2.53 CO2 O2 ppm corrected for %O2 220 443 8.22 Run 1 Enter O2 or CO2 Dry SO2 NOX CO CO2 O2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)3.6723E-01 4.5116E-01 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 2.558E-05 3.143E-05 lbs./hr.2.060 2.531 0.00 8.22 ppm corrected for %O2 219.55 443.13 8.20 Run 2 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr.6.60 9.60 ppm corrected for %O2 Raw Value Run 3 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr.6.60 9.60 ppm corrected for %O2 Raw Value Run 4 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr. ppm corrected for %O2 Raw Value Corrected For Cal. Drift Raw Value Corrected For Cal. Drift Corrected For Cal. Drift Corrected For Cal. Drift O2 CO2 Clear lbs./MMBTU Urban Oil C-103 2024 NOx and CO rev Calibration Error Test Test Date September 26, 2024 O2 CS - Cal. Span 20.90 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.00% Passed Cal. Mid-level 10.50 10.50 0.00 0.00% Passed Cal. High-level 20.90 21.00 0.10 0.48% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of CS - Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 50.24% 100% of Cal. Span High-level 100.00% Test Date CO2 CS - Cal. Span Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Test Date SO2 CS - Cal. Span Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Test Date September 26, 2024 NOx CS - Cal. Span 632.86 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.000% Passed Cal. Mid-level 313.96 314.80 0.84 0.133% Passed Cal. High-level 632.86 633.80 0.94 0.149% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 49.61% 100% of Cal. Span High-level 100.00% Test Date September 26, 2024 CO 5.51 CS - Cal. Span 1,023.00 498 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.000% Passed Cal. Mid-level 488.80 489.00 0.20 0.020% Passed Cal. High-level 1,023.00 1,023.00 0.00 0.000% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 47.78% 100% of Cal. Span High-level 100.00% Urban Oil C-103 2024 NOx and CO rev Division of Air Quality Stack Test Review of Urban Oil and Gas, Clawson Springs CS SO2 NOX CO CO2 O2 C-103 CS Calibration Span 632.86 1023.00 20.90Units ppm ppm ppm % % Unprotected CV - Cylinder Value:SO2 NOX CO CO2 O2Low-Level 0.00 0.00 0.00 Mid-Level 313.96 488.80 10.50 High-Level 632.86 1023.00 20.90 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 49.6% 47.8% 50.2% 100% of Cal. Span 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CDir CMA 313.96 488.80 20.90 Calibration Error Test Cs - Measured Concentration SO2 NOX CO CO2 O2Low-Level 0.00 0.00 0.00 Mid-Level 314.80 489.00 10.50 High-Level 633.80 1023.00 21.00 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 314.80 489.00 21.00 Low-Level 0.00% 0.00% 0.00% ppmdv Difference 0 0 0 Status Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.13% 0.02% 0.00% ppmdv Difference 0.84 0.2 0 Status Passed Cal. Passed Cal.Passed Cal. High-Level 0.15% 0.00% 0.48% ppmdv Difference 0.94 0 0.1 Status Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.00% 0.00% TRUE 0.00%± 5% of Span Difference TRUE 0 0 TRUE 0 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 315.40 488.00 20.97 SBi - Up-Scale Bias TRUE 0.09% 0.10% TRUE 0.14% Difference TRUE 0.60 1.00 TRUE 0.03 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:9/26/2024 SO2 SO2 NOX CO CO2 O2 NOX 215.3 429.30 8.2 CO 0.0% 34.0% 42.0% 0.0% 39.2%CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.00% 0.00% TRUE 0.00%± 5% of Span Difference TRUE 0.0 0.0 TRUE 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 315.90 483.00 20.97 SBi - Up-Scale Bias TRUE 0.17% 0.59% TRUE 0.14% Difference TRUE 1.1 6.0 TRUE 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.00% 0.00% TRUE 0.00% Drift Difference TRUE 0.0 0.0 TRUE 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Up-scale Gas Drift TRUE 0.08% 0.49% TRUE 0.00% Difference TRUE 0.5 5.0 TRUE 0.0Pass or Re-Calibrate Pass Pass Pass C-103 Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms FALSE 0.00 0.00 0.00 8.20 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws #NUM! 0.0000 #DIV/0! 0.1700 0.999 Load - Megawatts Avg. √∆P's Vs (ft/sec.)Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 1.0000 #VALUE! #VALUE! 5.6100204 Enert >X 3D Pito #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 1.00 1.000 2 1.00 1.000 3 4 5 6 Sum 7 8 9 10 11 12 13 1415 16 17 1819 20 21 2223 24 NOTEThese cells scans for the appropriate Cir. gas after the Cm If this scan is incorrect change the Cdir to the correct gas value. CO Calibration Gas Urban Oil C-103 2024 NOx and CO rev Division of Air Quality Stack Test Review of Urban Oil and Gas, Clawson Springs CS SO2 NOX CO CO2 O2 C-103 CS Calibration Span 632.86 1023.00 20.90 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2Low-Level 0.00 0.00 0.00 Mid-Level 313.96 488.80 10.50High-Level 632.86 1023.00 20.90 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 49.6% 47.8% 50.2% 100% of Cal. Span 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 313.96 488.80 20.90 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2Low-Level 0.00 0.00 0.00 Mid-Level 314.80 489.00 10.50 High-Level 633.80 1023.00 21.00 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 314.80 489.00 21.00 Low-Level 0.00% 0.00% 0.00% ppmdv Difference 0 0 0 Status Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.13% 0.02% 0.00% ppmdv Difference 0.84 0.2 0 Status Passed Cal. Passed Cal.Passed Cal. High-Level 0.15% 0.00% 0.48% ppmdv Difference 0.94 0 0.1 Status Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.00% 0.00% TRUE 0.00%± 5% of Span Difference TRUE 0 0 TRUE 0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 315.90 483.00 20.97 SBi - Up-Scale Bias TRUE 0.17% 0.59% TRUE 0.14% Difference TRUE 1.1 6 TRUE 0.03 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:9/26/2024 SO2 SO2 NOX CO CO2 O2 NOXCO 0.0% 0.0% 0.0% 0.0% 0.0% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level System Bias. SBi - Zero Bias TRUE TRUE TRUE TRUE TRUE ± 5% of Span Difference TRUE TRUE TRUE TRUE TRUE Pass or Invalid Run CM - Up-scale Gas SBi - Up-Scale Bias TRUE TRUE TRUE TRUE TRUE Difference TRUE TRUE TRUE TRUE TRUE Pass or Invalid Run Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE TRUE TRUE TRUE TRUE Response Spec. Difference TRUE TRUE TRUE TRUE TRUE 3% of Span Pass or Re-Calibrate Up-scale Gas Drift TRUE TRUE TRUE TRUE TRUE Difference TRUE TRUE TRUE TRUE TRUEPass or Re-Calibrate C-103 Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms FALSE 0.00 0.00 0.00 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws 0.0000 #DIV/0! 0.999 Load - Megawatts Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High #DIV/0! #DIV/0!Enert >X 3D Pito #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 Sum 78 9 1011 12 1314 15 16 17 18 19 20 2122 23 24 Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog Failed Bias Dialog Urban Oil C-103 2024 NOx and CO rev Division of Air Quality Stack Test Review of Urban Oil and Gas, Clawson Springs CS SO2 NOX CO CO2 O2 C-103 CS Calibration Span 632.86 1023.00 20.90 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2Low-Level 0.00 0.00 0.00 Mid-Level 313.96 488.80 10.50High-Level 632.86 1023.00 20.90 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 49.6% 47.8% 50.2% 100% of Cal. Span 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2Low-Level 0.00 0.00 0.00 Mid-Level 314.80 489.00 10.50 High-Level 633.80 1023.00 21.00 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 Low-Level 0.00% 0.00% 0.00% ppmv Difference 0 0 0 Status Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.13% 0.02% 0.00% ppmv Difference 0.84 0.2 0 Status Passed Cal. Passed Cal.Passed Cal. High-Level 0.15% 0.00% 0.48% ppmv Difference 0.94 0 0.1 Status Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level System Bias. SBi - Zero Bias TRUE TRUE TRUE TRUE TRUE ± 5% of Span Difference TRUE TRUE TRUE TRUE TRUE Pass or Invalid Run CM - Up-scale Gas SBi - Up-Scale Bias TRUE TRUE TRUE TRUE TRUE Difference TRUE TRUE TRUE TRUE TRUE Pass or Invalid Run Raw Test Data Time Start Stop Test Date:9/26/2024 SO2 SO2 NOX CO CO2 O2 NOXCO 0.0% 0.0% 0.0% 0.0% 0.0% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level System Bias. SBi - Zero Bias TRUE TRUE TRUE TRUE TRUE ± 5% of Span Difference TRUE TRUE TRUE TRUE TRUE Pass or Invalid Run CM - Up-scale Gas SBi - Up-Scale Bias TRUE TRUE TRUE TRUE TRUE Difference TRUE TRUE TRUE TRUE TRUE Pass or Invalid Run Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE TRUE TRUE TRUE TRUE Response Spec. Difference TRUE TRUE TRUE TRUE TRUE 3% of Span Pass or Re-Calibrate Up-scale Gas Drift TRUE TRUE TRUE TRUE TRUE Difference TRUE TRUE TRUE TRUE TRUEPass or Re-Calibrate C-103 Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms FALSE 0.00 0.00 0.00 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws 0.0000 #DIV/0! 0.999 Load - Megawatts Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High #DIV/0! #DIV/0!Enert >X 3D Pito #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 Sum 78 9 1011 12 1314 15 16 17 18 19 20 2122 23 24 Urban Oil C-104 2024 NOx and CO rev Reference Methods 2, 3A, 6C, 7E, 10, & 19 Source Information Company Name Urban Oil and Gas, Clawson Springs CS Company Contact:Kirt Rasmussen Contact Phone No.435-820-9801 Stack Designation:C-104 Test & Review Dates Test Date:9/26/2024 Review Date: 11/20/2024 Observer:Robert Sirrine Reviewer:Robert Sirrine Emission Limits Emission Rates SO2 NOX CO SO2 NOX CO lbs./kW-hr 1.74 1.87 1.439 1.332 lbs./hr. 5.15 5.5 2.581 2.388 ppm 282.0 498.00 252.140 383.300 Percent %O2 Correction as a whole #7.90 7.90 Test Information Heat Input Equivalent Diameter (in.)As ft^2 Y Dl H @ Cp Pbar Pq (static) fuel flow rate (Btu/hr.) Heat Input (Btu/hr.) FALSE 0.9960 1.717 0.84 23.12 -0.95 Contractor Information Contact: Cheyney Guymon Contracting Company: Montrose Air Quality Services Address: 6823 S 3600 W Spanish Fork, Utah Phone No.: Project No.: 8710 Division of Air Quality Instrumental Reference Methods - Gaseous Measurements Method 19 - F factors for Coal, Oil, and Gas Fd Fw Fc scf/MMBtu scf/MMBtu scf/MMBtu Diluent F factor used O2 CO2Anthrocite 2 Bituminous Lignite Natural Propane Butane 10100 COAL OIL GAS 9780 9860 9190 8710 8710 8710 10540 10640 11950 320 10610 10200 10390 1970 1800 1910 1420 1040 1190 1250 Wet CEM Correct For O2 CO2 Interference w/CO Yes Yes Yes Urban Oil C-104 2024 NOx and CO rev Division of Air Quality NSPS Relative Accuracy Performance Specification Test - CEMS Certification Urban Oil and Gas, Clawson Springs CS C-104 Average Emission Dry SO2 NOX CO g/hp-hr 1.439 1.332 Average % concentration lbs./hr.2.581 2.388 CO2 O2 ppm corrected for %O2 252.14 383.30 7.90 Run 1 Enter O2 or CO2 Dry SO2 NOX CO CO2 O2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)4.2175E-01 3.9025E-01 E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft 3.012E-05 2.787E-05 lbs./hr.2.581 2.388 0.00 7.90 ppm corrected for %O2 252.14 383.30 7.90 Run 2 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr.6.60 9.60 ppm corrected for %O2 Raw Value Run 3 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr.6.60 9.60 ppm corrected for %O2 Raw Value Run 4 Dry SO2 NOX CO CO2 O2 Atomic Weight 64 46 28 lbs./MMBtu (O2)E=Cd x Fd x (20.9/(20.9-%O2d)) lbs./MMBtu (CO2)E=Cd x Fc x (100 / % CO2d) lbs./cu.ft lbs./hr. ppm corrected for %O2 Raw Value Corrected For Cal. Drift Raw Value Corrected For Cal. Drift Corrected For Cal. Drift Corrected For Cal. Drift O2 CO2 Clear lbs./MMBTU Urban Oil C-104 2024 NOx and CO rev Calibration Error Test Test Date September 26, 2024 O2 CS - Cal. Span 20.90 Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.00% Passed Cal. Mid-level 10.50 10.50 0.00 0.00% Passed Cal. High-level 20.90 21.00 0.10 0.48% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of CS - Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 50.24% 100% of Cal. Span High-level 100.00% Test Date CO2 CS - Cal. Span Units % Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Test Date SO2 CS - Cal. Span Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level Mid-level High-level % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 40 to 60% of Cal. Span Mid-level 100% of Cal. Span High-level Test Date September 26, 2024 NOx CS - Cal. Span 632.86 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.000% Passed Cal. Mid-level 313.96 314.80 0.84 0.133% Passed Cal. High-level 632.86 633.80 0.94 0.149% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 49.61% 100% of Cal. Span High-level 100.00% Test Date September 26, 2024 CO 5.51 CS - Cal. Span 488.80 498 Units ppm Cylinder No. Expiration Date Cal. Gas CV- Certified Concentration CDir or CS - Measured Concentration Difference ACE Eq. 7E-1 Analyzer Cal. Error Status Low-level 0.00 0.00 0.00 0.000% Passed Cal. Mid-level 241.70 243.00 1.30 0.266% Passed Cal. High-level 488.80 489.00 0.20 0.041% Passed Cal. % of Span Sec. 8.2.1 Cal Gas Verification 0 to 20% of Cal. Span Low-Level 0.00% 40 to 60% of Cal. Span Mid-level 49.45% 100% of Cal. Span High-level 100.00% Urban Oil C-104 2024 NOx and CO rev Division of Air Quality Stack Test Review of Urban Oil and Gas, Clawson Springs CS SO2 NOX CO CO2 O2 C-104 CS Calibration Span 632.86 488.80 20.90Units ppm ppm ppm % % Unprotected CV - Cylinder Value:SO2 NOX CO CO2 O2Low-Level 0.00 0.00 0.00 Mid-Level 313.96 241.70 10.50 High-Level 632.86 488.80 20.90 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 49.6% 49.4% 50.2% 100% of Cal. Span 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CDir CMA 313.96 488.80 20.90 Calibration Error Test Cs - Measured Concentration SO2 NOX CO CO2 O2Low-Level 0.00 0.00 0.00 Mid-Level 314.80 243.00 10.50 High-Level 633.80 489.00 21.00 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 314.80 489.00 21.00 Low-Level 0.00% 0.00% 0.00% ppmdv Difference 0 0 0 Status Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.13% 0.27% 0.00% ppmdv Difference 0.84 1.3 0 Status Passed Cal. Passed Cal.Passed Cal. High-Level 0.15% 0.04% 0.48% ppmdv Difference 0.94 0.2 0.1 Status Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.00% 0.00% TRUE 0.00%± 5% of Span Difference TRUE 0 0 TRUE 0 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 314.90 489.00 20.95 SBi - Up-Scale Bias TRUE 0.02% 0.00% TRUE 0.24% Difference TRUE 0.10 0.00 TRUE 0.05 Pass or Failed Invalid Run Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:9/26/2024 SO2 SO2 NOX CO CO2 O2 NOX 253.5 380.80 7.9 CO 0.0% 40.1% 77.9% 0.0% 37.8%CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.00% 0.00% TRUE 0.00%± 5% of Span Difference TRUE 0.0 0.0 TRUE 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 316.40 482.00 20.97 SBi - Up-Scale Bias TRUE 0.25% 1.43% TRUE 0.14% Difference TRUE 1.6 7.0 TRUE 0.0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE 0.00% 0.00% TRUE 0.00% Drift Difference TRUE 0.0 0.0 TRUE 0.0 3% of Span Pass or Re-Calibrate Pass Pass Pass Up-scale Gas Drift TRUE 0.24% 1.43% TRUE 0.10% Difference TRUE 1.5 7.0 TRUE 0.0Pass or Re-Calibrate Pass Pass Pass C-104 Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms FALSE 23.12 -0.95 23.05 7.90 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws #VALUE! 0.9960 0.84 0.1700 0.999 Load - Megawatts Avg. √∆P's Vs (ft/sec.)Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High 1.0000 #VALUE! #VALUE! 6.12 Enert >X 3D Pito #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 1.00 1.000 2 1.00 1.000 3 4 5 6 Sum 7 8 9 10 11 12 13 1415 16 17 1819 20 21 2223 24 NOTEThese cells scans for the appropriate Cir. gas after the Cm If this scan is incorrect change the Cdir to the correct gas value. CO Calibration Gas Urban Oil C-104 2024 NOx and CO rev Division of Air Quality Stack Test Review of Urban Oil and Gas, Clawson Springs CS SO2 NOX CO CO2 O2 C-104 CS Calibration Span 632.86 488.80 20.90 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2Low-Level 0.00 0.00 0.00 Mid-Level 313.96 241.70 10.50High-Level 632.86 488.80 20.90 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 49.6% 49.4% 50.2% 100% of Cal. Span 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA 313.96 488.80 20.90 Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2Low-Level 0.00 0.00 0.00 Mid-Level 314.80 243.00 10.50 High-Level 633.80 489.00 21.00 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 314.80 489.00 21.00 Low-Level 0.00% 0.00% 0.00% ppmdv Difference 0 0 0 Status Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.13% 0.27% 0.00% ppmdv Difference 0.84 1.3 0 Status Passed Cal. Passed Cal.Passed Cal. High-Level 0.15% 0.04% 0.48% ppmdv Difference 0.94 0.2 0.1 Status Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level 0.00 0.00 0.00 System Bias. SBi - Zero Bias TRUE 0.00% 0.00% TRUE 0.00%± 5% of Span Difference TRUE 0 0 TRUE 0 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. CM - Up-scale Gas 316.40 482.00 20.97 SBi - Up-Scale Bias TRUE 0.25% 1.43% TRUE 0.14% Difference TRUE 1.6 7 TRUE 0.03 Pass or Invalid Run Passed Cal. Passed Cal. Passed Cal. Raw Test Data Time Start Stop Test Date:9/26/2024 SO2 SO2 NOX CO CO2 O2 NOXCO 0.0% 0.0% 0.0% 0.0% 0.0% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level System Bias. SBi - Zero Bias TRUE TRUE TRUE TRUE TRUE ± 5% of Span Difference TRUE TRUE TRUE TRUE TRUE Pass or Invalid Run CM - Up-scale Gas SBi - Up-Scale Bias TRUE TRUE TRUE TRUE TRUE Difference TRUE TRUE TRUE TRUE TRUE Pass or Invalid Run Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE TRUE TRUE TRUE TRUE Response Spec. Difference TRUE TRUE TRUE TRUE TRUE 3% of Span Pass or Re-Calibrate Up-scale Gas Drift TRUE TRUE TRUE TRUE TRUE Difference TRUE TRUE TRUE TRUE TRUEPass or Re-Calibrate C-104 Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms FALSE 23.12 -0.95 23.05 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws 0.9960 0.84 0.999 Load - Megawatts Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High #DIV/0! #DIV/0!Enert >X 3D Pito #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 Sum 78 9 1011 12 1314 15 16 17 18 19 20 2122 23 24 Failed Bias Dialog Failed Drift Dialog Failed Cal Error Dialog Failed Bias Dialog Urban Oil C-104 2024 NOx and CO rev Division of Air Quality Stack Test Review of Urban Oil and Gas, Clawson Springs CS SO2 NOX CO CO2 O2 C-104 CS Calibration Span 632.86 488.80 20.90 Units ppm ppm ppm % % CV - Cylinder Value:SO2 NOX CO CO2 O2Low-Level 0.00 0.00 0.00 Mid-Level 313.96 241.70 10.50High-Level 632.86 488.80 20.90 0 to 20% of Cal. Span 0.00% 0.00% 0.00% 40 to 60% of Cal. Span 49.6% 49.4% 50.2% 100% of Cal. Span 100.0% 100.0% 100.0% Cdir - Enter Actual Up-scale Cylinder Value Used To Correct Emission Concentration. CMA Calibration Error Test Measured Concentration SO2 NOX CO CO2 O2Low-Level 0.00 0.00 0.00 Mid-Level 314.80 243.00 10.50 High-Level 633.80 489.00 21.00 Enter Up-scale Analyzer Response to be used during testing. ACE Eq. 7E-1 Low-Level 0.00% 0.00% 0.00% ppmv Difference 0 0 0 Status Passed Cal. Passed Cal.Passed Cal. Mid-Level 0.13% 0.27% 0.00% ppmv Difference 0.84 1.3 0 Status Passed Cal. Passed Cal.Passed Cal. High-Level 0.15% 0.04% 0.48% ppmv Difference 0.94 0.2 0.1 Status Passed Cal. Passed Cal.Passed Cal. Pre-Test Sampling System Bias Initial Values SO2 NOX CO CO2 O2 CO - Low-Level System Bias. SBi - Zero Bias TRUE TRUE TRUE TRUE TRUE ± 5% of Span Difference TRUE TRUE TRUE TRUE TRUE Pass or Invalid Run CM - Up-scale Gas SBi - Up-Scale Bias TRUE TRUE TRUE TRUE TRUE Difference TRUE TRUE TRUE TRUE TRUE Pass or Invalid Run Raw Test Data Time Start Stop Test Date:9/26/2024 SO2 SO2 NOX CO CO2 O2 NOXCO 0.0% 0.0% 0.0% 0.0% 0.0% CO2/O2 Post-Test System Bias 7E-2 SB=(Cs - Cdir)/CS x 100 Final Values SO2 NOX CO CO2 O2 CO - Low-Level System Bias. SBi - Zero Bias TRUE TRUE TRUE TRUE TRUE ± 5% of Span Difference TRUE TRUE TRUE TRUE TRUE Pass or Invalid Run CM - Up-scale Gas SBi - Up-Scale Bias TRUE TRUE TRUE TRUE TRUE Difference TRUE TRUE TRUE TRUE TRUE Pass or Invalid Run Calibration Drift % of Span - D=ABS(SBf - SBi) Low-Level Drift TRUE TRUE TRUE TRUE TRUE Response Spec. Difference TRUE TRUE TRUE TRUE TRUE 3% of Span Pass or Re-Calibrate Up-scale Gas Drift TRUE TRUE TRUE TRUE TRUE Difference TRUE TRUE TRUE TRUE TRUEPass or Re-Calibrate C-104 Flow & Moisture As ft^2 Pbar Pq (static) Ps Avg Ts F CO2 - FCO2 O2 N2+C Md Ms FALSE 23.12 -0.95 23.05 Y Cp Vm cf Vlc AVG Tm F Vm std Vw std Bws S Bws 0.9960 0.84 0.999 Load - Megawatts Avg. √∆P's Vs Qsw scfh wet Qa acfm Qsd dscfh Heat Input Btu/hr Low Mid High #DIV/0! #DIV/0!Enert >X 3D Pito #1 - Times Date Point No.∆P √∆P ts F tm F (in) tm F (out) Final Vf Initial Vi 1 2 3 4 5 6 Sum 78 9 1011 12 1314 15 16 17 18 19 20 2122 23 24