Loading...
HomeMy WebLinkAboutDERR-2024-004868 WASATCH ENVIRONMENTAL, INC. ENVIRONMENTAL SCIENCE AND ENGINEERING 2410 WEST CALIFORNIA AVENUE SALT LAKE CITY, UTAH 84104 PHONE (801) 972-8400 FAX (801) 972-8459 e-mail: wei@wasatch-environmental.com www.wasatch-environmental.com SOIL CONFIRMATION SAMPLING REPORT BUILDING 2212 AND 2214 SOIL CONFIRMATION SAMPLING 765 NORTH 2200 WEST SALT LAKE CITY, UTAH Project No. 2778-001 Prepared for: 151 CES Attention: Mr. Bobby Foreman 765 North 2200 West Salt Lake City, Utah 84416 October 16, 2023 Prepared by: Wasatch Environmental, Inc. 2410 West California Avenue Salt Lake City, Utah 84104 Soil Confirmation Sampling Building 2212 and 2214 Soil Confirmation Sampling Wasatch Environmental, Inc. 1 SOIL CONFIRMATION SAMPLING REPORT BUILDING 2212 AND 2214 SOIL CONFIRMATION SAMPLING 765 NORTH 2200 WEST SALT LAKE CITY, UTAH INTRODUCTION Wasatch Environmental, Inc., (Wasatch) has completed soil confirmation sampling activities near buildings 2212 and 2214 at the Utah Air National Guard (UTANG) property located at 765 North 2200 West in Salt Lake City, Utah (Site). These activities consisted of the collection of eight soil confirmation samples from within an excavated trench at the Site. BACKGROUND The UTANG, specifically 151 CES, experienced a diesel fuel release within a fuel line piping run during the installation of underground water utilities at the Site. The UTANG removed approximately 337 feet of fuel piping and some diesel fuel-impacted soil from the release area (the fuel piping run). The UTANG requested that Wasatch collect soil confirmation samples to verify that the diesel- impacted fuel piping run had been sufficiently remediated. OBJECTIVE The objective of this sampling event was to evaluate the current petroleum hydrocarbon impacts within the excavated trench at the Site involved with a release of diesel fuel. FIELD METHODOLOGY See Appendix A for a photolog of the field activities. A visual observation of the entire length of the open trench was completed by walking the trench to evaluate for residual soil staining and petroleum hydrocarbon odors. Soil Confirmation Sampling On September 28, 2023, Wasatch Environmental Scientist, Mrs. Anna Fiorini, completed the trench inspection and soil confirmation sampling activities within the open trench at the Site. Wasatch collected eight soil confirmation samples (CS-1 through CS-8) from the floor of the trench at approximately 3 feet below ground surface (bgs). The CS-1 sample was biased to the area where the fuel piping was damaged and released the diesel fuel. From this area, Wasatch collected soil confirmation samples to the east and west to not allow more than 50 linear feet of trench to go unsampled, per Utah Division of Environmental Response and Remediation (DERR) guidelines. The soil samples were field logged by Mrs. Fiorini. The field logging included a description of color, moisture content, consistency, odor, staining, and soil type based on the Unified Soil Classification System and screened in the field with a photoionization detector (PID). The PID was utilized to identify soils which have been impacted by volatile organic compounds (VOCs) such as those found in petroleum constituents and some chlorinated solvents. Soil samples collected for analysis of methyl tertiary-butyl ether, benzene, toluene, ethylbenzene, total xylenes, and naphthalene (MBTEXN) were collected using a laboratory-supplied sampling device, sample preservation methods, and sample containers consistent with U.S. EPA Method 5035A for the Soil Confirmation Sampling Building 2212 and 2214 Soil Confirmation Sampling Wasatch Environmental, Inc. 2 collection of VOCs. Soil samples were collected from each sample interval for both low-range (0.5 to 250 micrograms per kilogram [µg/kg]) and high-range (>250 µg/kg) laboratory analysis for VOCs. Low-range soil samples were collected as 5-gram (g) aliquots and placed in laboratory-supplied, unpreserved volatile organic analysis (VOA) bottles, and immediately placed in a cooler with dry ice. High-range samples were collected as 10-g aliquots and placed in laboratory-supplied VOA bottles preserved with methanol and immediately placed in a cooler with ice. All soil samples collected for total petroleum hydrocarbons as diesel-range organics (TPH-DRO) were collected into 4-ounce glass jars. All soil samples were delivered under chain-of-custody protocol to Chemtech-Ford Laboratories, a Utah-certified analytical laboratory, for analysis of MBTEXN using U.S. EPA Method 8260D and TPH-DRO using U.S. EPA Method 8015D. RESULTS Soil Confirmation Sampling Soil within the trench generally consists of silty clay (CL) with some fine-grained sands lenses. Groundwater was not encountered within the trench. No field indications (i.e., soil staining, elevated PID readings, or odors) of contamination were observed within the trench. Analyte concentrations in soil were compared to the Utah Initial Screening Levels (ISLs) and the Utah Risk-Based Corrective Action (RBCA) Tier 1 Screening Levels. Sample locations are shown in Figure 2. Soil analytical data are summarized in Table 1. The laboratory analytical report and chain-of- custody documentation are presented in Appendix B. No analytes were detected above laboratory reporting limits in any of the samples. CONCLUSIONS AND RECOMMENDATIONS Wasatch successfully completed a visual observation of the entire trench at the Site and collected eight soil confirmation samples from the floor of the trench. No field observations indicative of contamination was observed within the trench at the Site. Based on the soil data, no petroleum hydrocarbons were detected within the trench. Therefore, the release within the trench area appears to have been remediated to concentrations below the applicable Utah ISLs. Based on the data, no further investigation is recommended, and the trench can be backfilled at UTANG’s convenience. Our services consist of professional opinions and recommendations made in accordance with generally accepted environmental engineering principles and practices. This warranty is in lieu of all other warranties either expressed or implied. Should you have any questions, please do not hesitate to contact us. Soil Confirmation Sampling Building 2212 and 2214 Soil Confirmation Sampling Wasatch Environmental, Inc. 3 Sincerely, WASATCH ENVIRONMENTAL, INC. Blake B. Downey, P.G. Anna Fiorini Senior Project Hydrogeologist Staff Environmental Scientist Certified UST Consultant CC-0268 Certified Soil and Groundwater Sampler GS-1788 FIGURES Figure 1 – Site Location Map Figure 2 – Sample Location Map TABLE Table 1 – Soil Analytical Data APPENDICES Appendix A – Photolog Appendix B – Soil Laboratory Analytical Report Figures The use or reuse of this information is restricted to the referenced document unless otherwise authorized. Wasatch Environmental Copyright 2006 BUILDING 2214 AND 2214 SOIL CONFIRMATION SAMPLING WEI 2778-001 Figure 1Site Location Map Approximate Site Boundary Salt Lake International Airport I-215 700 North 22 0 0 W es t I000 North 400 North Re d w o o d R o a d The use or reuse of this information is restricted to the referenced document unless otherwise authorized. Wasatch Environmental Copyright 2006 WEI 2778-001 Figure 2Sample Location Map1 inch = 57 feet Approximate Trench Location 22 0 0 W es t 700 North Approximate Area of Release Approximate Site Boundary CS-1 CS-2 CS-3 CS-4CS-5CS-6 CS-7 CS-8 Soil Confirmation Sample Location BUILDING 2214 AND 2214 SOIL CONFIRMATION SAMPLING Table Sample Identification PID Reading (ppm) Depth (feet) Sample Collection Date TP H - D R O Be n z e n e To l u e n e Et h y l b e n z e n e To t a l X y l e n e s Na p h t h a l e n e MT B E CS-1 0.0 3 9/28/2023 <57 <0.002 <0.006 <0.006 <0.006 <0.006 <0.002 CS-2 0.0 3 9/28/2023 <56 <0.002 <0.005 <0.005 <0.005 <0.005 <0.002 CS-3 0.0 3 9/28/2023 <59 <0.002 <0.005 <0.005 <0.005 <0.005 <0.002 CS-4 0.0 3 9/28/2023 <60 <0.002 <0.005 <0.005 <0.005 <0.005 <0.002 CS-5 0.0 3 9/28/2023 <64 <0.002 <0.006 <0.006 <0.006 <0.006 <0.002 CS-6 0.0 3 9/28/2023 <66 <0.002 <0.006 <0.006 <0.005 <0.006 <0.002 CS-7 0.0 3 9/28/2023 <62 <0.002 <0.005 <0.005 <0.005 <0.005 <0.002 CS-8 0.0 3 9/28/2023 <61 <0.002 <0.006 <0.006 <0.006 <0.006 <0.002 500 0.2 9 5 142 51 0.3 5,000 0.9 25 23 142 51 0.3 NOTES: < = Concentration was below the laboratory reporting limit RBCA = Risk-Based Corrective Action PID = Photoionization detector ppm = Parts per million Utah Initial Screening Levels Utah RBCA Tier 1 Screening Levels Table 1 Soil Analytical Data Building 2212 and 2214 Soil Confirmation Sampling Salt Lake City, Utah all concentrations are reported in milligrams per kilogram (mg/kg) 765 North 2200 West Soil Confirmation Samples Appendix A Photolog Photo 1. Release site facing east Photo 2. Eastern end of trench Photo 3. Release site facing west Photo 4. Western portion of trench Photo 5. Soil confirmation sample CS-1 location Photo 6. Soil confirmation sample CS-2 location Photo 7. Soil confirmation sample CS-3 location Photo 8. Soil confirmation sample CS-4 location Photo 9. Soil confirmation sample CS-5 location Photo 10. Soil confirmation sample CS-6 location Photo 11. Soil confirmation sample CS-7 location Photo 12. Soil confirmation sample CS-8 location Appendix B Soil Laboratory Analytical Report The analyses presented on this report were performed in accordance with the National Environmental Laboratory Accreditation Program (NELAP) unless noted in the comments, flags, or case narrative. If the report is to be used for regulatory compliance, it should be presented in its entirety, and not be altered. Client Service Contact: 801.262.7299 Wasatch Environmental Attn: Blake Downey 2410 West California Avenue Salt Lake City, UT 84104 Work Order: 23I2323 Project: Utah Air National Guard 9/29/2023 Approved By: Reed Hendricks, Lab Director 9632 South 500 West Sandy, Utah 84070 Serving the Intermountain West since 1953 801.262.7299 Main 866.792.0093 Fax www.ChemtechFord.com Page 1 of 11 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Wasatch Environmental Blake Downey 2410 West California Avenue Salt Lake City, UT 84104 PO#: Receipt: Date Reported: Project Name: 2778-001 9/28/23 12:15 @ -0.4 °C 9/29/2023 Utah Air National Guard Sample ID: CS-1 Lab ID: 23I2323-01Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 9/28/23 9:36 Preparation Date/Time Sampled By: Anna Fiorini Minimum Reporting Limit MethodResult Diesel Range with silica gel cleanup mg/kg dry 9/28/239/28/2357EPA 8015 CNDDiesel Range Organics Inorganic %9/28/239/28/230.1 CTF800087.9Total Solids MBTEXn mg/kg dry 9/28/239/28/230.002 EPA 8260D/5035ANDBenzene mg/kg dry 9/28/239/28/230.006 EPA 8260D/5035ANDEthylbenzene mg/kg dry 9/28/239/28/230.002 EPA 8260D/5035ANDMethyl tert-Butyl Ether (MTBE) mg/kg dry 9/28/239/28/230.006 EPA 8260D/5035ANDNaphthalene mg/kg dry 9/28/239/28/230.006 EPA 8260D/5035ANDToluene mg/kg dry 9/28/239/28/230.006 EPA 8260D/5035ANDXylenes, total Project Name: Utah Air National Guard CtF WO#: 23I2323 www.ChemtechFord.com Page 2 of 11Page 2 of 11 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Wasatch Environmental Blake Downey 2410 West California Avenue Salt Lake City, UT 84104 PO#: Receipt: Date Reported: Project Name: 2778-001 9/28/23 12:15 @ -0.4 °C 9/29/2023 Utah Air National Guard Sample ID: CS-2 Lab ID: 23I2323-02Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 9/28/23 9:50 Preparation Date/Time Sampled By: Anna Fiorini Minimum Reporting Limit MethodResult Diesel Range with silica gel cleanup mg/kg dry 9/28/239/28/2356EPA 8015 CNDDiesel Range Organics Inorganic %9/28/239/28/230.1 CTF800089.4Total Solids MBTEXn mg/kg dry 9/28/239/28/230.002 EPA 8260D/5035ANDBenzene mg/kg dry 9/28/239/28/230.005 EPA 8260D/5035ANDEthylbenzene mg/kg dry 9/28/239/28/230.002 EPA 8260D/5035ANDMethyl tert-Butyl Ether (MTBE) mg/kg dry 9/28/239/28/230.005 EPA 8260D/5035ANDNaphthalene mg/kg dry 9/28/239/28/230.005 EPA 8260D/5035ANDToluene mg/kg dry 9/28/239/28/230.005 EPA 8260D/5035ANDXylenes, total Project Name: Utah Air National Guard CtF WO#: 23I2323 www.ChemtechFord.com Page 3 of 11Page 3 of 11 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Wasatch Environmental Blake Downey 2410 West California Avenue Salt Lake City, UT 84104 PO#: Receipt: Date Reported: Project Name: 2778-001 9/28/23 12:15 @ -0.4 °C 9/29/2023 Utah Air National Guard Sample ID: CS-3 Lab ID: 23I2323-03Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 9/28/23 10:10 Preparation Date/Time Sampled By: Anna Fiorini Minimum Reporting Limit MethodResult Diesel Range with silica gel cleanup mg/kg dry 9/28/239/28/2359EPA 8015 CNDDiesel Range Organics Inorganic %9/28/239/28/230.1 CTF800084.7Total Solids MBTEXn mg/kg dry 9/28/239/28/230.002 EPA 8260D/5035ANDBenzene mg/kg dry 9/28/239/28/230.005 EPA 8260D/5035ANDEthylbenzene mg/kg dry 9/28/239/28/230.002 EPA 8260D/5035ANDMethyl tert-Butyl Ether (MTBE) mg/kg dry 9/28/239/28/230.005 EPA 8260D/5035ANDNaphthalene mg/kg dry 9/28/239/28/230.005 EPA 8260D/5035ANDToluene mg/kg dry 9/28/239/28/230.005 EPA 8260D/5035ANDXylenes, total Project Name: Utah Air National Guard CtF WO#: 23I2323 www.ChemtechFord.com Page 4 of 11Page 4 of 11 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Wasatch Environmental Blake Downey 2410 West California Avenue Salt Lake City, UT 84104 PO#: Receipt: Date Reported: Project Name: 2778-001 9/28/23 12:15 @ -0.4 °C 9/29/2023 Utah Air National Guard Sample ID: CS-4 Lab ID: 23I2323-04Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 9/28/23 10:30 Preparation Date/Time Sampled By: Anna Fiorini Minimum Reporting Limit MethodResult Diesel Range with silica gel cleanup mg/kg dry 9/28/239/28/2360EPA 8015 CNDDiesel Range Organics Inorganic %9/28/239/28/230.1 CTF800083.3Total Solids MBTEXn mg/kg dry 9/28/239/28/230.002 EPA 8260D/5035ANDBenzene mg/kg dry 9/28/239/28/230.005 EPA 8260D/5035ANDEthylbenzene mg/kg dry 9/28/239/28/230.002 EPA 8260D/5035ANDMethyl tert-Butyl Ether (MTBE) mg/kg dry 9/28/239/28/230.005 EPA 8260D/5035ANDNaphthalene mg/kg dry 9/28/239/28/230.005 EPA 8260D/5035ANDToluene mg/kg dry 9/28/239/28/230.005 EPA 8260D/5035ANDXylenes, total Project Name: Utah Air National Guard CtF WO#: 23I2323 www.ChemtechFord.com Page 5 of 11Page 5 of 11 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Wasatch Environmental Blake Downey 2410 West California Avenue Salt Lake City, UT 84104 PO#: Receipt: Date Reported: Project Name: 2778-001 9/28/23 12:15 @ -0.4 °C 9/29/2023 Utah Air National Guard Sample ID: CS-5 Lab ID: 23I2323-05Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 9/28/23 10:47 Preparation Date/Time Sampled By: Anna Fiorini Minimum Reporting Limit MethodResult Diesel Range with silica gel cleanup mg/kg dry 9/28/239/28/2364EPA 8015 CNDDiesel Range Organics Inorganic %9/28/239/28/230.1 CTF800078.0Total Solids MBTEXn mg/kg dry 9/28/239/28/230.002 EPA 8260D/5035ANDBenzene mg/kg dry 9/28/239/28/230.006 EPA 8260D/5035ANDEthylbenzene mg/kg dry 9/28/239/28/230.002 EPA 8260D/5035ANDMethyl tert-Butyl Ether (MTBE) mg/kg dry 9/28/239/28/230.006 EPA 8260D/5035ANDNaphthalene mg/kg dry 9/28/239/28/230.006 EPA 8260D/5035ANDToluene mg/kg dry 9/28/239/28/230.006 EPA 8260D/5035ANDXylenes, total Project Name: Utah Air National Guard CtF WO#: 23I2323 www.ChemtechFord.com Page 6 of 11Page 6 of 11 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Wasatch Environmental Blake Downey 2410 West California Avenue Salt Lake City, UT 84104 PO#: Receipt: Date Reported: Project Name: 2778-001 9/28/23 12:15 @ -0.4 °C 9/29/2023 Utah Air National Guard Sample ID: CS-6 Lab ID: 23I2323-06Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 9/28/23 10:59 Preparation Date/Time Sampled By: Anna Fiorini Minimum Reporting Limit MethodResult Diesel Range with silica gel cleanup mg/kg dry 9/28/239/28/2366EPA 8015 CNDDiesel Range Organics Inorganic %9/28/239/28/230.1 CTF800075.3Total Solids MBTEXn mg/kg dry 9/28/239/28/230.002 EPA 8260D/5035ANDBenzene mg/kg dry 9/28/239/28/230.006 EPA 8260D/5035ANDEthylbenzene mg/kg dry 9/28/239/28/230.002 EPA 8260D/5035ANDMethyl tert-Butyl Ether (MTBE) mg/kg dry 9/28/239/28/230.006 EPA 8260D/5035ANDNaphthalene mg/kg dry 9/28/239/28/230.006 EPA 8260D/5035ANDToluene mg/kg dry 9/28/239/28/230.006 EPA 8260D/5035ANDXylenes, total Project Name: Utah Air National Guard CtF WO#: 23I2323 www.ChemtechFord.com Page 7 of 11Page 7 of 11 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Wasatch Environmental Blake Downey 2410 West California Avenue Salt Lake City, UT 84104 PO#: Receipt: Date Reported: Project Name: 2778-001 9/28/23 12:15 @ -0.4 °C 9/29/2023 Utah Air National Guard Sample ID: CS-7 Lab ID: 23I2323-07Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 9/28/23 11:08 Preparation Date/Time Sampled By: Anna Fiorini Minimum Reporting Limit MethodResult Diesel Range with silica gel cleanup mg/kg dry 9/28/239/28/2362EPA 8015 CNDDiesel Range Organics Inorganic %9/28/239/28/230.1 CTF800080.6Total Solids MBTEXn mg/kg dry 9/28/239/28/230.002 EPA 8260D/5035ANDBenzene mg/kg dry 9/28/239/28/230.005 EPA 8260D/5035ANDEthylbenzene mg/kg dry 9/28/239/28/230.002 EPA 8260D/5035ANDMethyl tert-Butyl Ether (MTBE) mg/kg dry 9/28/239/28/230.005 EPA 8260D/5035ANDNaphthalene mg/kg dry 9/28/239/28/230.005 EPA 8260D/5035ANDToluene mg/kg dry 9/28/239/28/230.005 EPA 8260D/5035ANDXylenes, total Project Name: Utah Air National Guard CtF WO#: 23I2323 www.ChemtechFord.com Page 8 of 11Page 8 of 11 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Wasatch Environmental Blake Downey 2410 West California Avenue Salt Lake City, UT 84104 PO#: Receipt: Date Reported: Project Name: 2778-001 9/28/23 12:15 @ -0.4 °C 9/29/2023 Utah Air National Guard Sample ID: CS-8 Lab ID: 23I2323-08Matrix: Solid Flag(s)Units Analysis Date/Time Date Sampled: 9/28/23 11:20 Preparation Date/Time Sampled By: Anna Fiorini Minimum Reporting Limit MethodResult Diesel Range with silica gel cleanup mg/kg dry 9/28/239/28/2361EPA 8015 CNDDiesel Range Organics Inorganic %9/28/239/28/230.1 CTF800081.7Total Solids MBTEXn mg/kg dry 9/28/239/28/230.002 EPA 8260D/5035ANDBenzene mg/kg dry 9/28/239/28/230.006 EPA 8260D/5035ANDEthylbenzene mg/kg dry 9/28/239/28/230.002 EPA 8260D/5035ANDMethyl tert-Butyl Ether (MTBE) mg/kg dry 9/28/239/28/230.006 EPA 8260D/5035ANDNaphthalene mg/kg dry 9/28/239/28/230.006 EPA 8260D/5035ANDToluene mg/kg dry 9/28/239/28/230.006 EPA 8260D/5035ANDXylenes, total Project Name: Utah Air National Guard CtF WO#: 23I2323 www.ChemtechFord.com Page 9 of 11Page 9 of 11 xx Chemtech-Ford Laboratories Serving the Intermountain West Since 1953 Certificate of Analysis 9632 South 500 West Sandy, UT 84070 O:(801) 262-7299 F: (866) 792-0093 www.ChemtechFord.com Wasatch Environmental Blake Downey 2410 West California Avenue Salt Lake City, UT 84104 PO#: Receipt: Date Reported: Project Name: 2778-001 9/28/23 12:15 @ -0.4 °C 9/29/2023 Utah Air National Guard Report Footnotes Abbreviations ND = Not detected at the corresponding Minimum Reporting Limit (MRL). 1 mg/L = one milligram per liter or 1 mg/kg = one milligram per kilogram = 1 part per million. 1 ug/L = one microgram per liter or 1 ug/kg = one microgram per kilogram = 1 part per billion. 1 ng/L = one nanogram per liter or 1 ng/kg = one nanogram per kilogram = 1 part per trillion. On calculated parameters, there may be a slight difference between summing the rounded values shown on the report vs the unrounded values used in the calculation. Project Name: Utah Air National Guard CtF WO#: 23I2323 www.ChemtechFord.com Page 10 of 11Page 10 of 11 Page 11 of 11