HomeMy WebLinkAboutDAQ-2024-0119471
DAQC-PBR041940001-24
Site ID 4194 (B1)
MEMORANDUM
TO: FILE – UINTA WAX OPERATING, LLC – WINDY RIDGE-LIVSEY 25-15
THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager
FROM: Stephen Foulger, Environmental Scientist
DATE: November 27, 2024
SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION
INSPECTION DATE: October 29, 2024
SOURCE LOCATION: Lat:40.2764, Long: -109.9411
Uintah County
Business Office:
Uinta Wax Operating, LLC
1308 Lake Street
Fort Worth, TX 76102
SOURCE TYPE: Tank Battery
API: 4304740605
SOURCE CONTACTS: Kaitlin Meszaros, Corporate Environmental Contact
Phone: 720-614-5598, Email: meszaros@pinyon-env.com
Kaylene Bridwell, Field Contact
Phone: 405-496-7308, Email: kaylene.bridwell@uintawax.com
OPERATING STATUS: Operating
PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products
go through a separator where the oil and any water products are
sent to storage tanks and the gas is used to power equipment on
site (pump jack engine, tank heater, separator, flare, combustor,
etc.) Any remaining gas is sent to a pipeline that feeds a local
gas plant. The oil and process water in the storage tanks is
loaded into tanker trucks and hauled off-site for processing and
disposal.
APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil
and Gas Industry, and UAC R307-201: Emission Standards:
General Emission Standards; and UAC R307-150: Emission
Inventories. Federal Subpart: 40 CFR 60 Subpart OOOO.
SOURCE EVALUATION: Site Type: PBR – Uncontrolled DOGM current 12 month rolling production is: 4,455.
2
Utah Statute R307-506 requires a source with throughput greater than 8,000 BBLs to have controls.
REGISTERED EQUIPMENT: Pneumatic, Tank
Visible Emissions
Visible emissions are within the following opacity limits: VOC Control Devices and Gasoline engines
0%, Diesel engines 20%, Natural Gas Engines and Boilers, Treater burners & Tank burners 10%, Mobile
source dust 10%. [R307-201-3]
In Compliance. No visible emissions were observed at the time of inspection.
VOC emissions are, at all times, minimized as reasonably practicable by equipment design, maintenance
and operation practices. [R307-501-4(1)]
In Compliance. VOC emissions found properly controlled at the time of inspection.
Pneumatic Controllers
Truck loading is done by bottom filling or submerged fill pipe [R307-504(1)]
In Compliance. Truck loading found properly engineered at the time of inspection.
Storage Vessels
Thief hatches are kept closed and latched. [R307-506-4(1)]
In Compliance. Thief hatches found closed and latched at the time of inspection.
Upon modification, the well site was re-evaluated against the thresholds of R307-506-4(2).
[R307-506-4(6)]
In Compliance. The combustor was removed from this location after production levels dropped to
appropriate levels.
Emission Inventory:
An emissions inventory has been submitted within the past three years. [R307-150-9(1)]
In Compliance. This source was found properly reported in the last emissions inventory.
Oil and Gas Industry Registration Requirement
The source is registered with the DAQ. [R307-505-3(3)] In Compliance. Source found properly registered at the time of inspection.
3
Registration has been updated within 30 days of a company name change, removal or addition of control
devices, or termination of operations. [R307-505-3(3)]
In Compliance. Source registration found properly updated at the time of inspection.
Records for each of the following are kept for three years:
Monthly storage vessel vent system inspections (openings, thief hatches, pressure relief devices,
bypasses, etc.), if controlled.
Monthly crude oil throughput
Emission calculations, actuals and sampling data when used to justify an exemption to storage
vessel rules
Emergency storage vessel usage (dates used, emptied, and volumes), if not controlled. [R307-506-5]
In Compliance. These records were reviewed at the time of inspection and were found to be
compliant.
NSPS (Part 60) OOOO: Standards of Performance for Crude Oil and Natural Gas Production,
Transmission and Distribution [40 CFR 60 Subpart OOOO]
In Compliance.
PREVIOUS ENFORCEMENT
ACTIONS: This source was found not in compliance in 2022.
COMPLIANCE STATUS &
RECOMMENDATIONS: In regards to the site, the overall status is: In Compliance.
RECOMMENDATION FOR
NEXT INSPECTION: Recommend to decrease inspection frequency.
ATTACHMENTS: None.