Loading...
HomeMy WebLinkAboutDERR-2024-012779Page 1 of_ Utah Department of Environmental Quality APST Equipment Verification Inspection Ownership of Tanks Location of Tanks KILGORE COMPANIES , LLC KILGORE PAVING & MAINTENANCE PO BOX869 7057 W 2100 S 4002421 MAGNA luT 184044 WEST VALLEY CITY luT 184128 Contact Name : #/Email : - SPCC Plan?: ~e9 No I Last Fire Marshal lnsp : ATG Info: Complete for each tank. # J/.i # I B # # # # Capacity of tank (gallons): ~ IL. 4-1.( Orientation of tank: U-nr ,· "7-D 11-l-t.1 l Bottom of tank in contact with (soil, gravel , concrete , not touching): -!Vnk I::. IO u r/h ,'.A""' Substance stored : f)1',b5.,fJ,/ /'_ 1.2 _< I fMt. Date last used/depth of product: .... Type of spill prevention device: D," rfl111,-..t, ,J,_ W /~,d Type of Piping (Pressure or Suction): p~~ <. C./Ai ,...p ~ Does pressure piping have LLD : Yes No-@ Yes No ~ Yes No NA Yes No NA Yes No NA Yes No NA Spill bucket is clean, intact, etc .: fesJ No ~sJ No Yes No Yes No Yes No Yes No Type of overfill Prevention device : Overfill alarm (audible or visible) is properly located so delivery driver can hear or see it, and is clearly identified : Yes No NA Pipe trans fle x protection method 5UrY\, 11 -.... (Sump , CP , Isolated, Booted): Containment sumps dry : Yes ~o) NA Yes 11a) NA Yes No NA Yes No NA Yes No NA Yes No NA ~ Sump comments : Stage 1 Vapor Recovery : 2pt Coax None_ 2pt _ Coax None 2pt Coax None 2pt Coax None 2pt Coax None 2pt Coax None Pressure Vent Valve is on vents : Y~s No ¥AJ I tes) No NA Yes No NA Yes No NA Yes No NA Yes No NA Secondary containment area - comments: d,y Complete for each dispenser # IP ? /2. # :Jll!ilp I # # # # Flex protection method (UDC, CA l'J G u () c,, Cathod ic Protection, Isolated , Booted): UDC sump dry : '4ls <f'o) NA ~s ) No NA Yes No NA Yes No NA Yes No NA Yes No NA Fire valve anchored , located below ~ No NA v No NA Yes No NA Yes No NA Yes No NA Yes No NA grade , and without ball valve : Comments : Additional dispenser questions # # # # # # Flex protection method (UDC , Cathodic Protection , Isolated , Booted): UDC sump dry: Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA Fire valve anchored , located below Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA grade, and no ball valve : Comments : Additional Comments : Financial Responsibility (State Use Only) FR Method: r.1 ~ -,-l Method OK? l ~ No by: 5.&~'-./ Signatures I ~ n ,.-1 h W ;J /)'\ er Inspected this facility on{:ilt./.:lA Signz:1..P'AAA / (//a /Jt-,t?/ Tl 2/tf 0/0 Signature : Attach Tank Info Sheet to Inspection with any edits . Page2of_ Utah Department of Environmental Quality APST Facility Site Plat --- NORTH 2 loo .s ---------- i£J f fl l L:.. _:::..z I ,------------~------~,/ 4002421 Show locations of all buildings, streets, tanks , piping, and dispenser islands. Indicate the product in each tank . Show locations of tank manways and identify each : submersible pump (S), tank fill (F), ATG probe (A), interstitial probe (I), vapor recovery (V), capped plug (C), other (specify). -----------------------Comments :