Loading...
HomeMy WebLinkAboutDDW-2024-014145TC = Total Coliform EC = E coli Bacteriological Flow Chart State of Utah REVISED TOTAL COLIFORM RULE (RTCR) (Effective 4/1/2016) GROUNDWATER RULE (GWR) (Effective 12/1/2009) Level 1 Site Assessment -Required when: 1. Two or more TC+ samples (routine and repeat results) in one month. 2. Fail to collect 3 repeat samples for each routine TC+ -May be performed by the Water System Level 2 Site Assessment Required when: 1.TC+ routine and EC+ repeat sample 2. EC+ routine and TC+ repeat sample 3. Fail to collect all 3 required repeats following an EC+ rountine sample. 4. Two Level 1 triggers in 12 months -Must be performed by the DDW or DDW approved third party -Notify the DDW and LHD -Level 2 Assessment required -Issue Tier 1 Public Notice* which includes a "Boil Order" TC+ EC+ (E coli +) REPEAT -Collect a set of 3 repeat samples for EACH TC+ within 24 hours at these locations: 1. Original site 2. Upstream 3. Downstream Return to routine sampling TC-EC- Collect 3 repeat samples until TC is not detected in two complete sets of repeats TC+ or EC+ No violation End sampling TC-EC-TRIGGERED SOURCE SAMPLES Collect 1 sample within 24 hours at these locations: 1. Each source in use at the time of the TC+ or, 2. At an approved DDW representative site (SSG01) Collect samples before treatment No violation End sampling TC+ EC- TC+ EC+ *Issue GWR Tier 1 Special Notice* and Tier 1 Pulic Notice* -Collect 5 confirmation source samples from the source(s) that had EC+ No violation End sampling TC-EC- No violation End Sampling TC+ EC- TC+ EC+ Perform corrective action TC+ sample(s) require meeting the requirements of both the GWR and RTCR. Contact DDW : 801-536-4200. Submit reports to: DDWReports @utah.gov See also: www.drinkingwater.utah.gov First positive repeat in 12 months -Perform Level 1 Assessment -Issue Tier 2 Public Notice* -Fix Sanitary Defects -Submit Assessment form to the DDW within 30 days Two level 1 triggers in a 12-rolling month period -Level 2 Assessment is required -Contact DDW -Issue Tier 2 Public Notice* -Fix Sanitary Defects TC+ EC- Tier 2-Provide public notice within 30 days (posting, hand/direct delivery, mail a separate notice or include with a bill) Tier 1 GWR Special Notice 1. Fecal indicator-positive source 2. Uncorrected significant deficiencies -Provide Special Notice annually until DDW determines the significant deficiencies are corrected and the fecal contamination is addressed. Tier 1 -Provide notice within 24 hrs. (posting, hand delivery, radio, TV) -Report to DDW and LHD -Issue Boil Order *PUBLIC NOTICE GW R RTCR RTCR SITE ASSESSMENTS