Loading...
HomeMy WebLinkAboutDERR-2024-012656AST Annual Visual Inspection Checklist (Revised 05/11/2023) Facility ID#: Facility Name: Inspection Date: Street Address: City: ZIP: # of Tanks Inspected: Tank ID Numbers: Any item marked “No” requires additional information to describe the condition and date the condition is corrected. ITEM STATUS COMMENTS / DATE CORRECTED Containment 1 Is the containment structure in satisfactory condition (diking, impounding, double-wall tank, etc.)? Yes No 2 Are the drainage pipes/valves in good working condition for continued service? Yes No N/A Tank Foundation/Supports 3 Free of tank settlement or foundation washout? Yes No 4 Concrete pad or ring wall free of cracking or spalling? Yes No 5 Tank supports in satisfactory condition? Yes No 6 Is water able to drain away from tank? Yes No 7 Is the grounding strap between the tank and foundation/supports in good condition? Yes No N/A Cathodic Protection 8 Are cathodic protection system in operating condition and functional? Yes No N/A 9 Rectifier reading Volts: ________ Amps: _______ Are these readings within manufacturer specifications? Yes No N/A Tank External Coating 10 Free of visible signs of paint failure? Yes No Tank Shell / Heads 11 Free of noticeable shell/head distortions, buckling, denting, or bulging? Yes No 12 Free of visible signs of shell/head corrosion or cracking? Yes No Tank Manways, Piping, and Equipment 13 Flanged connection bolts tight and fully engaged with no sign of wear or corrosion? Yes No N/A Tank Roof 14 Free of standing water on roof? Yes No 15 Free of visible signs of coating cracking, crazing, peeling, or blistering? Yes No 16 Free of holes? Yes No AST Annual Visual Inspection Form Page 1 of 2 Pilot Thomas #109 10-12-24 350 N. Vernal Ave.Vernal 84078 3 DSL, REG, PRM 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 ITEM STATUS COMMENTS/DATE CORRECTED Venting 17 Normal and emergency vents free of obstructions? Yes No 18 Normal vent on tanks storing gasoline equipped with pressure/vacuum vent cap? Yes No N/A 19 Is the emergency vent in good working condition and functional, and tested as required by manufacturer? Yes No Insulated Tanks 20 Free of missing insulation? Yes No N/A 21 Insulation free of noticeable areas of moisture? Yes No N/A 22 Insulation free of mold? Yes No N/A 23 Insulation free of visible signs of damage? Yes No N/A 24 Insulation adequately protected from water intrusion? Yes No N/A Level and Overfill Prevention Equipment 25 Electronic or mechanical liquid level gauge tested for proper operation? Yes No N/A 26 Electronic or mechanical liquid level gauge calibrated during the previous 12 months? Yes No N/A 27 Is overfill prevention equipment in good working condition? Overfill Valve Audible Alarm Both Yes No N/A Verified by: Inspection Date: Operational? Yes No Repair Date: 28 Is tank ullage being determined and documented before filling the tank? Yes No N/A Electrical Equipment 29 Is tank/equipment grounding adequate and in good condition? Yes No 30 Is electrical wiring for control boxes, lights, and other high voltage equipment in good condition? Yes No N/A Additional Comments Inspector Information (Certified Individual or Professional Engineer) Printed Name: Signature: Date: AST Annual Visual Inspection Form Page 2 of 2 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Max LaRou UT-412 10/12/2024 EZY CHEK SYSTEMS TEST DATE PRODUCT LINE TESTER Testing Company Information DATA SHEET Name Address City Test Location Information Precision Testing Technologies, Inc. 2026 W. Elk Creek Crt. Bluffdale, UT Test Location Information Phone Name Address Technican Information City Name Phone Cert # 801-886-9224 Contact Applied Pressure #1 Product Type:#2 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.00370.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #3 Product Type:#4 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.00370.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: #5 Product Type:#6 Product Type: TIME DATA -/+GPL RES GPH TIME DATA -/+GPL RES GPH 0 0.0037 0.0000 0.0000 0 0.0037 0.0000 0.000000.0037 0.0000 0.0000 0 0.0037 0.0000 0.0000 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 0.0037 FINAL RESULT:FINAL RESULT: Facility ID# : 10/12/2024 Pilot Thomas #109 350 N. Vernal Ave. Vernal, UT 84078 Max LaRou UT-412 55 P.S.I. REG 0 71 15 71 0 0 0 30 71 0 0 0 PASS PRM 0 52 15 52 0 0 0 30 52 0 0 0 PASS DSL, Sats 1, 4 0 29 15 29 0 0 0 30 29 0 0 0 PASS 10/12/2024 Max LaRou UT-412 pei.org 43 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-3 SPILL BUCKET INTEGRITY TESTING HYDROSTATIC TEST METHOD SINGLE AND DOUBLE-WALLED VACUUM TEST METHOD )DFLOLW\1DPH2ZQHU $GGUHVV$GGUHVV &LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH )DFLOLW\,'3KRQH 7HVWLQJ&RPSDQ\3KRQH'DWH 7KLVSURFHGXUHLVWRWHVWWKHOHDNLQWHJULW\RIVLQJOHDQGGRXEOHZDOOHGVSLOOEXFNHWV6HH3(,536HFWLRQIRUK\GURVWDWLF WHVWPHWKRG6HFWLRQIRUVLQJOHZDOOHGYDFXXPWHVWPHWKRGDQG6HFWLRQIRUGRXEOHZDOOHGYDFXXPWHVWPHWKRG 7DQN1XPEHU 3URGXFW6WRUHG 6SLOO%XFNHW &DSDFLW\ 0DQXIDFWXUHU &RQVWUXFWLRQ6LQJOHZDOOHG 'RXEOHZDOOHG 6LQJOHZDOOHG 'RXEOHZDOOHG 6LQJOHZDOOHG 'RXEOHZDOOHG 6LQJOHZDOOHG 'RXEOHZDOOHG 6LQJOHZDOOHG 'RXEOHZDOOHG 6LQJOHZDOOHG 'RXEOHZDOOHG 7HVW7\SH +\GURVWDWLF 9DFXXP 6LQJOHZDOOHG 'RXEOHZDOOHG +\GURVWDWLF 9DFXXP 6LQJOHZDOOHG 'RXEOHZDOOHG +\GURVWDWLF 9DFXXP 6LQJOHZDOOHG 'RXEOHZDOOHG +\GURVWDWLF 9DFXXP 6LQJOHZDOOHG 'RXEOHZDOOHG +\GURVWDWLF 9DFXXP 6LQJOHZDOOHG 'RXEOHZDOOHG +\GURVWDWLF 9DFXXP 6LQJOHZDOOHG 'RXEOHZDOOHG 6SLOO%XFNHW7\SH 3URGXFW 9DSRU 3URGXFW 9DSRU 3URGXFW 9DSRU 3URGXFW 9DSRU 3URGXFW 9DSRU 3URGXFW 9DSRU /LTXLGDQGGHEULV UHPRYHGIURP VSLOOEXFNHW" <HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 9LVXDO,QVSHFWLRQ 1RFUDFNVORRVH SDUWVRUVHSDUD WLRQRIWKHEXFNHW IURPWKHILOOSLSH 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 7DQNULVHUFDS LQFOXGHGLQWHVW" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ ,VGUDLQYDOYH LQFOXGHGLQWHVW" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ 6WDUWLQJ/HYHO 7HVW6WDUW7LPH       (QGLQJ/HYHO 7HVW(QG7LPH 7HVW3HULRG /HYHO&KDQJH 3DVVIDLOFULWHULD0XVWSDVVYLVXDOLQVSHFWLRQ+\GURVWDWLF:DWHUOHYHOGURSRIOHVVWKDQLQFK9DFXXPVLQJOHZDOOHGRQO\ 0DLQWDLQDWOHDVWLQFKHVZDWHUFROXPQ9DFXXPGRXEOHZDOOHGPDLQWDLQDWOHDVWLQFKHVZDWHUFROXPQ Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: $OOOLTXLGVDQGGHEULVPXVWEHGLVSRVHGRISURSHUO\ 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Pilot Thomas #140 10/12/2024 1 CLR DSL 15 Gal. Morrison Bros. 4 4 4 4 4 4 4 4 5.5" 0 Min. 5.5" 60 Min. 60 Min. 0 4 2 DYE DSL 15 Gal. Morrison Bros 4 4 4 4 4 4 4 4 5.5" 0 Min. 5.5" 60 Min. 60 Min. 0 4 3 CLR DSL Truck 15 Gal. Morrison Bros. 4 4 4 4 4 4 4 4 5.5" 0 Min. 5.5" 60 Min. 60 Min. 0 4 4 CLR DSL Auto 15 Gal. Morrison Bros. 4 4 4 4 4 4 4 4 5.5" 0 Min. 5.5" 60 Min. 60 Min. 0 4 5 PRM 15 Gal. Morrison Bros. 4 4 4 4 4 4 4 4 5.5" 0 Min. 5.5" 60 Min. 60 Min. 0 4 6 REG 15 Gal. Morrison Bros. 4 4 4 4 4 4 4 4 5.5" 0 Min. 5.5" 60 Min. 60 Min. 0 4 Max LaRou UT-412