HomeMy WebLinkAboutDAQ-2024-0117751
DAQC-PBR034910001-24
Site ID 3491 (B1)
MEMORANDUM
TO: FILE – SCOUT ENERGY MANAGEMENT, LLC – Federal 8-20-8-16
THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager
FROM: Chris Jensen, Environmental Scientist
DATE: November 18, 2024
SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION
INSPECTION DATE: November 13, 2024
SOURCE LOCATION: Lat:40.104421, Long: -110.136527
Business Office:
Scout Energy Management, LLC
13800 Montfort Drive, Suite 100
Dallas, TX 75240
SOURCE TYPE: Tank Battery
Duchesne
API: 4301333995
SOURCE CONTACTS: Chris Breitling, Corporate Environmental Contact
Phone: 469-485-3418, Email: chris.breitling@scoutep.com
Kevan Stevens, Local Contact
Email: kevan.stevens@scoutep.com
OPERATING STATUS: Long term shut in
PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products go
through a separator where the oil and any water products are sent to
storage tanks and the gas is used to power equipment on site (pump
jack engine, tank heater, separator, flare, combustor, etc.) Any
remaining gas is sent to a pipeline that feeds a local gas plant. The oil
and process water in the storage tanks is loaded into tanker trucks and
hauled off-site for processing and disposal.
APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil and
Gas Industry, and UAC R307-201: Emission Standards: General
Emission Standards; and UAC R307-150: Emission Inventories.
Federal Subpart: NESHAP ZZZZ.
SOURCE EVALUATION: Site Type: PBR – Uncontrolled
No Flare Controls, Site powered by Engine.
DOGM current 12 month rolling production is: 0 BBLs.
Utah Statute R307-506 requires a source with throughput
greater than 8,000 BBLs to have controls.
2
REGISTERED EQUIPMENT: Engine - Engine - Natural Gas 2-Stroke Lean Burn Make - Ajax
Model - E-42 Mfg Year - Pre 7/1/2008 Horse Power - 40 Combustion
- Natural Gas, Pneumatic, Tank
Visible Emissions
Visible emissions are within the following opacity limits: VOC Control Devices and Gasoline engines
0%, Diesel engines 20%, Natural Gas Engines and Boilers, Treater burners & Tank burners 10%, Mobile
source dust 10%. [R307-201-3]
In Compliance. No visible emissions were detected by use of the USEPA Method 9.
General Provisions:
Truck loading is done by bottom filling or submerged fill pipe. [R307-504(1)]
In Compliance.
All natural gas-driven pneumatic controllers are in compliance with 40CFR 60.5390 or 60.5390a as
applicable. Tagging and record keeping requirements are not required. [R307-502-4]
In Compliance. This source does not use continuous bleed natural gas-driven pneumatic
controllers.
Storage Vessels
Thief hatches are kept closed and latched. [R307-506-4(1)]
In Compliance. All hatches were found closed at the start of the evaluation.
Natural Gas Engines
Affected engine exhaust vents are vertical and unrestricted.
Stacks are 8' or greater if the site horsepower rating is 151 to 305
Stacks are 10' or greater if the site horse power rating is 306 or greater. [R307-510-4(3)]
In Compliance.
Emission Inventory:
An emissions inventory has been submitted within the past three years. [R307-150-9(1)]
In Compliance. The operator submitted for the 2020 emissions inventory. The results for the 2023
inventory have not yet been released.
3
Oil and Gas Industry Registration Requirement
The source is registered with the DAQ. [R307-505-3(3)]
In Compliance.
Natural Gas Engines:
Engines subject to R307-510 shall be certified or have an initial performance test per CFR 60.4244.
[R307-510-4(2)]
In Compliance. This engine is not EPA certified. It was installed prior to 2008 NSPS JJJJ
applicability and will not be required to conduct a performance test.
Engine certifications or initial performance tests required are kept for the life of the engine at the source.
[R307-510-5]
In Compliance. Engines installed before 2016 are not under obligation to retain certifications or
stack tests for life.
NESHAP (Part 63) ZZZZ: National Emissions Standards for Hazardous Air Pollutants for Stationary
Reciprocating Internal Combustion Engines. [40 CFR 63 Subpart ZZZZ]
In Compliance. Engine maintenance is planned for every six months but has not been performed
as the engine has sat idle for over a decade.
PREVIOUS ENFORCEMENT
ACTIONS: None in the past 5 years.
COMPLIANCE STATUS &
RECOMMENDATIONS: In Compliance. The source was surveyed by AVO and with an OGI
camera and was found to be well-kept with no visible or fugitive
emissions. Requested records were provided in a timely manner and
reviewed at the local field office. This well has been shut in since
2012.
RECOMMENDATION FOR
NEXT INSPECTION: The DAQ has no recommendations for the next inspector other than
what are customary. The DAQ was joined by Scout personnel during
the site inspection.
RECOMMENDATIONS FOR NSR: None.