HomeMy WebLinkAboutDSHW-2024-009335Site Information Finalized Yes Facility Name Iron County Class I Landfill Facility_ID SW0197 Facility Name Iron County Class I Landfill Street Address 3127 N. Iron Springs Road City Cedar City ZIP Code 84720 County Iron County Inspection Date 11-12-2024 Type of Visit Routine Oversite Is the Visit Announced?No 40.664169, -111.955260 Weather Conditions Rain/snow, 34 degrees Inspection Goal Ensure compliance with the facility permit and Utah rules and regulations Facility Contact Bruce Anderson Participants Kelly Shaw (DWMRC), Jeremy (Facility) Follow Up Inspection Needed?N/A Recommended Follow Up Date Depart Office Date 11-12-2024 Depart Office time 06:30 AM (-7 GMT) Return to Office Date 11-13-2024 Return to Office time 03:00 PM (-7 GMT) 1. Pre-Inspection Review 1.1 Permit Review Yes Comment Permit expires 7/5/2032. The facility accepts MSW, Commercial solid waste, industrial solid waste, C&D waste, special waste, hazardous waste generated by a very small quantity generator, PCB wastes and asbestos. 1.2 Annual Report Review Yes Comment Facility received 88,226 tons of in-state MSW waste and 29.75 tons of out- of-state waste in 2023. 1.3 Previous Inspection Review Yes Comment No deficiencies were noted during the past inspection. 1.4 Facility Contacts Confirmed Yes Date Submitted: 11-19-2024 04:49 PM Submitted By: kellyshaw@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 1 of 10 Comment Bruce Anderson is still the contact 1.5 Facility Contacted (If an announced inspection) No Comment 1.6 Local Health Contacted Yes Comment Did not participate 1.7 Other Comment 2. Facility / Operational Controls (1-Good, 5-Poor) 2.1 Litter 2 2.2 Roads 1 2.3 Gate House Operations 1 2.4 Vectors 1 2.5 Communications 1 2.6 Recycling Area 1 2.7 Fugitive Dust Control 1 2.8 Waste Inspection Area 1 2.9 Scavenging Control 1 2.10 Open Burning NA 2.11 Fences, Gates, Locks, Access Control 1 2.12 Working Face 3 2.13 Daily - Soil 1 2.14 Daily - Alternative NA 2.15 Leachate Collection System NA 2.16 Other Comment (Required)Windblown litter picked up monthly. The working face was large, but it was due to a fire the facility had. They were working to get the section where the fire took place covered to reduce the working face size. A puddle of dark brown liquid and litter were observed in the Cell B area that is currently not being used. The facility did not know what the liquid was. 3. Signs Required / Properly Posted 3.1 Operating Days / Hours Yes 3.2 Directions & Procedures Yes 3.3 Emergency Numbers Yes 3.4 List of Unacceptable Materials Yes Date Submitted: 11-19-2024 04:49 PM Submitted By: kellyshaw@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 2 of 10 3.5 Other Comment (Required)The facility has good signage through out. 4. Operator / Representative / Employees 4.1 On-site While Open Yes 4.2 Training Yes 4.3 Other Comment (Required)Thorough records are maintained. The facility is looking to better organize by implementing the use of Fast Field. 5. Monitoring 5.1 Methane Yes 5.2 Random Inspections Yes 5.3 Leachate N/A 5.4 Ground Water Yes 5.5 Other Comment (Required)Monitoring is performed and recorded. 6. Drainage / Erosion 6.1 Water Run-on Yes 6.2 Water Run-off Yes 6.3 Other Comment (Required)Controls are in place. 7. Proper Storage / Isolation / Disposal 7.1 Special Waste Yes 7.2 Batteries N/A 7.3 Hazardous Waste N/A 7.4 Infectious Waste N/A 7.6 Dead Animals Yes 7.7 Asbestos Yes 7.8 Bulky Waste Yes 7.9 Contaminated Soil Yes 7.10 Ash N/A 7.11 Sludge Yes 7.12 Other Comment (Required)If batteries are found in a load they are segregated and sent for recycling. Date Submitted: 11-19-2024 04:49 PM Submitted By: kellyshaw@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 3 of 10 8. Cover 8.1 Intermediate Yes 8.2 Final N/A 8.3 Vegetation N/A 8.4 Other Comment (Required)Intermediate cover has been placed at Cell B, however there is an unknown brown liquid that appears to be seeping up and litter in the cell. 9. Inspection Records 9.1 Random Inspection Report Yes 9.2 Gas Monitoring System N/A 9.3 Surface Drainage Control No 9.4 Daily Records Yes 9.5 Weight or Volumes Yes 9.6 Intermediate Cover Yes 9.7 Final Cover N/A 9.8 Self Inspection (Quarterly Reports) Yes 9.9 Deviation From Plans N/A 9.10 Permit, Permit Application, and Rules Available Yes 9.11 Other Comment (Required)Methane is monitored with a handheld device. The facility was unaware they needed to maintain records of surface drainage control inspections and will implement that practice. 10. Monitoring / Sampling / Analysis Records 10.1 Explosive Gas Monitoring Yes 10.2 Leachate Sampling & Treatment N/A 10.3 Ground Water Sampling Results Yes 10.4 Other Comment (Required)Monitoring is performed. 11. Special Waste Records 11.1 Lab Analysis Results N/A 11.2 Manifests Yes 11.3 Treatment Certification N/A Date Submitted: 11-19-2024 04:49 PM Submitted By: kellyshaw@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 4 of 10 11.4 Paint Filter Test Results Yes 11.5 Onsite Treatment Documentation N/A 11.6 Other Comment (Required)Manifests are maintained and paint filter tests are performed when appropriate. 12. Waste Tires 12.1 Acceptance procedures for Waste Tires Yes 12.2 Waste Tire Pile Segregated Yes 12.3 Estimated Quanitity of Waste Tires No Number of Tires 12.4 Waste Tire Fund Training N/A Comment (Required)The facility is looking into renting a tire shredder to shred the tires on site. 13 Other Items 13.1 Notice of Inspections Form Completed and Signed N/A 13.2 N/A 13.3 N/A 13.4 N/A Comment (Required)Not applicable to this facility. 14. Special Permit Requirements 14.1 N/A 14.2 N/A 14.3 N/A Comment (Required)Not applicable to this facility. General Comments Comments The facility has good signage throughout. Thorough records are maintained although they are lacking inspection records for surface drainage controls. The facility is planning to implement the use of Fast Field to make record keeping more efficient and organized. They will implement documentation of surface drainage control inspections. Brown liquid and litter were observed in cell B which is not currently in use. The facility operator did not know what the brown liquid was. Metals and waste tires are segregated for recycling. The working face was very large, the operator indicated they had a fire and were unable to place cover because they had to dig out the fire. He said they were working to decrease the size of the working face. Date Submitted: 11-19-2024 04:49 PM Submitted By: kellyshaw@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 5 of 10 DWMRC Inspector Signature DWMRC Inspector Name Kelly Shaw Date/Time 11-12-2024 Photos Attach Photos Entrance signage Metals pile for recycling. Dumpsters for public disposal of waste Date Submitted: 11-19-2024 04:49 PM Submitted By: kellyshaw@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 6 of 10 Waste tire pile segregated for recycling. The facility is looking into renting a tire shredder. Pallets to be shredded Green waste pile to be burned by the fire department for training exercises Drying beds Date Submitted: 11-19-2024 04:49 PM Submitted By: kellyshaw@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 7 of 10 Working face Gate to asbestos pit Waste and unknown liquid in inactive pit B Unknown liquid and waste in inactive pit B Date Submitted: 11-19-2024 04:49 PM Submitted By: kellyshaw@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 8 of 10 Overview look of the working face in the active pit Date Submitted: 11-19-2024 04:49 PM Submitted By: kellyshaw@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 9 of 10