DERR-2024-012331
Testing and Inspection Certificate Tanknology Inc. 11000 North MoPac Expressway, Suite 500, Austin, TX 78759 800-800-4633 www.tanknology.com Page 1 of 1 Test Date 11/15/2024 Tanknology WO#NW1-2377785 Test Purpose COMPLIANCE Customer PO# Customer Location Menzies Aviation PO BOX 22287 Salt Lake City, UT 84112 Menzies Aviation (SALT LAKE CITY) 1070 North 3930 West Salt Lake City, UT 84116 Attn: Chris Hurst Attn: Chris Hurst (385) 388-2166 (385) 388-2166 Test / Inspection Description Item Tested Date Tested Result RP 1200 ATG See test report for details 11/15/2024 Pass RP 1200 Sensors See test report for details 11/15/2024 Pass Tanknology Representative: David Edens Technician: David Mathie Telephone: ()Technician Certification: (See forms) Menzies Aviation Menzies Aviation 1070 North 3930 West Salt Lake City UT 84116 SALT LAKE CITY Tanknology, Inc. PO BOX 22287 Salt Lake City UT 84112 385-388-2166 800-964-1250 11/15/2024 ST1 VR TNK2 ST2 VR TNK1 WASTE FUEL WASTE FUEL VR450PLUS VR450PLUS 2319 2904 69.8 69.8 58.75 58.75 NA 4 UT151 ST1 NO WATER FLOAT David Mathie 1070 North 3930 West Menzies Aviation 1070 North 3930 West, Salt Lake City, UT 84116 SALT LAKE CITY Tanknology, Inc. Menzies Aviation PO BOX 22287 Salt Lake City, UT 84112 385-388-2166 11/15/2024 ANNULAR ANNULAR ST1 VRTNK2 ST2 VRTNK1 UT151 David Mathie Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2377785 Site ID / Name:SALT LAKE CITY / Menzies Aviation Address:1070 North 3930 West City:Salt Lake City State:UT Zip:84116 W.O.# NW1-2377785 OVF W.O.# NW1-2377785 +AAE- I10100 11/15/24 9:46 AM Menzies Aviation P.O.B. 22287 S.L.C., Utah 84122 801-531-4710 SYSTEM STATUS REPORT ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 Tank ST2 INVALID FUEL LEVEL ALARM 11-15-24 09:39AM +AAMAAQ- I20100 11/15/24 9:46 AM Menzies Aviation P.O.B. 22287 S.L.C., Utah 84122 801-531-4710 IN-TANK INVENTORY TANK PRODUCT VOLUME TC-VOLUME ULLAGE HEIGHT WATER TEMP 1 ST2 258 0 2646 10.12 2.76 62.57 2 ST1 46 0 2273 3.71 0.00 65.40 +AAMAAQ- I30100 11/15/24 9:46 AM Menzies Aviation P.O.B. 22287 S.L.C., Utah 84122 801-531-4710 LIQUID STATUS REPORT SENSOR LOCATION STATUS 1 ST2 Normal 2 ST1 Normal +AAMAAQ- I30200 11/15/24 9:46 AM Menzies Aviation P.O.B. 22287 S.L.C., Utah 84122 801-531-4710 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 ST2 11/15/24 9:31 AM FUEL ALARM 11/14/23 10:35 AM FUEL ALARM 2 ST1 11/15/24 9:23 AM FUEL ALARM 12/06/23 1:12 PM FUEL ALARM 12/06/23 1:05 PM SENSOR OUT ALARM +AAMAAQ- I20600 11/15/24 9:47 AM Menzies Aviation P.O.B. 22287 S.L.C., Utah 84122 801-531-4710 TANK ALARM HISTORY TANK 1 ST2 SETUP DATA WARNING 03/02/23 7:17 AM HIGH WATER ALARM 12/06/23 9:53 AM 04/05/23 11:51 AM OVERFILL ALARM 11/15/24 9:38 AM 11/14/23 10:43 AM INVALID FUEL LEVEL 11/15/24 9:39 AM 11/13/24 11:54 AM 10/30/24 2:56 PM HIGH WATER WARNING 11/15/24 9:37 AM 03/05/24 10:51 AM 02/12/24 1:50 PM TANK 2 ST1 SETUP DATA WARNING 03/02/23 7:17 AM HIGH WATER ALARM 10/30/24 2:28 PM 10/07/24 2:54 PM 07/09/24 9:54 AM OVERFILL ALARM 11/15/24 9:21 AM 11/14/23 10:55 AM INVALID FUEL LEVEL 11/15/24 9:23 AM 11/15/24 9:17 AM 11/13/24 12:45 PM HIGH WATER WARNING 10/30/24 2:28 PM 10/07/24 2:54 PM 07/09/24 9:54 AM +AAMAAQ- I6SU00 11/15/24 9:47 AM -------------------------------------------------------- +ACoAKgAq- SETUP FOR ALL TANKS +ACoAKgAq- -------------------------------------------------------- ULLAGE DISPLAY MODE: FULL ULLAGE FULL ULLAGE LABEL: 100+ACU- ULLAGE USER ULLAGE: DISABLED PRINT TC VOLUMES: DISABLED TC REFERENCE TEMPERATURE: 60 DEG F PERIODIC TEST NEEDED WARNINGS: DISABLED DAYS BEFORE PERIODIC WARNING: 25 DAYS BEFORE PERIODIC ALARM: 30 ANNUAL TEST NEEDED WARNINGS: DISABLED DAYS BEFORE ANNUAL WARNING: 355 DAYS BEFORE ANNUAL ALARM: 365 TC DENSITY: DISABLED STICK HEIGHT: DISABLED LEAK TEST REPORT FORMAT: STANDARD LEAK TEST REGION: EPA -------------------------------------------------------- +ACoAKgAq- TANK SETUP +ACoAKgAq- -------------------------------------------------------- --- GENERAL SETUP - TANK 1 --- CONFIGURED: ENABLED LABEL: ST2 PRODUCT CODE: 1 PROBE NUMBER: Pb 1: ST2 PROBE OFFSET: 0.00 INCHES FULL VOLUME: 2904 GALLONS DIAMETER: 69.8 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000470 METER DATA PRESENT: DISABLED DELIVERY DELAY: 1 MINUTES GROSS TEST FAIL: ALARMS DISABLED PERIODIC TEST FAIL: ALARMS DISABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 1 --- MAX VOLUME: 2904 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 0+ACU- LOW PRODUCT: 0 GALLONS HIGH WATER WARNING: 4.00 INCHES HIGH WATER ALARM: 5.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 99 GALLONS SUDDEN LOSS LIMIT: 100 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 1 --- TANK TEST METHOD: DISABLED --- PROFILE - TANK 1 --- TANK PROFILE: FOUR POINT +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 69.8 2904 003 34.9 1477 002 52.3 2421 004 17.4 565 --- TANK 1 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: FOUR POINT SOURCE: USER ENTERED LAST CHANGE: 2023-03-02 STATUS: ACTIVE VOLUME ENTRY: TOTAL VOLUME +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 69.8 2904 003 34.9 1477 002 52.3 2421 004 17.4 565 --- TANK 1 --- T1 SIPHON MANIFOLDED TO TANKS: NONE T1 LINE MANIFOLDED TO TANKS: NONE --- HRM - TANK 1 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS --- GENERAL SETUP - TANK 2 --- CONFIGURED: ENABLED LABEL: ST1 PRODUCT CODE: 2 PROBE NUMBER: Pb 2: ST1 PROBE OFFSET: 0.00 INCHES FULL VOLUME: 2319 GALLONS DIAMETER: 69.8 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000470 METER DATA PRESENT: DISABLED DELIVERY DELAY: 1 MINUTES GROSS TEST FAIL: ALARMS DISABLED PERIODIC TEST FAIL: ALARMS DISABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 2 --- MAX VOLUME: 2319 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 0+ACU- LOW PRODUCT: 0 GALLONS HIGH WATER WARNING: 4.00 INCHES HIGH WATER ALARM: 5.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 99 GALLONS SUDDEN LOSS LIMIT: 100 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 2 --- TANK TEST METHOD: DISABLED --- PROFILE - TANK 2 --- TANK PROFILE: FOUR POINT +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 69.8 2319 003 34.9 1184 002 52.3 1907 004 17.4 448 --- TANK 2 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: FOUR POINT SOURCE: USER ENTERED LAST CHANGE: 2023-03-02 STATUS: ACTIVE VOLUME ENTRY: TOTAL VOLUME +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 69.8 2319 003 34.9 1184 002 52.3 1907 004 17.4 448 --- TANK 2 --- T2 SIPHON MANIFOLDED TO TANKS: NONE T2 LINE MANIFOLDED TO TANKS: NONE --- HRM - TANK 2 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS +AAMAAQ- I70300 11/15/24 9:47 AM LIQUID MODEL SENSOR LABEL MODEL 1 ST2 Tri-State(Single Float) 2 ST1 Tri-State(Single Float) 3 Tri-State(Single Float) 4 Tri-State(Single Float) 5 Tri-State(Single Float) 6 Tri-State(Single Float) 7 Tri-State(Single Float) 8 Tri-State(Single Float) 9 Tri-State(Single Float) 10 Tri-State(Single Float) 11 Tri-State(Single Float) 12 Tri-State(Single Float) 13 Tri-State(Single Float) 14 Tri-State(Single Float) 15 Tri-State(Single Float) 16 Tri-State(Single Float) 17 Tri-State(Single Float) 18 Tri-State(Single Float) 19 Tri-State(Single Float) 20 Tri-State(Single Float) 21 Tri-State(Single Float) 22 Tri-State(Single Float) 23 Tri-State(Single Float) 24 Tri-State(Single Float) 25 Tri-State(Single Float) 26 Tri-State(Single Float) 27 Tri-State(Single Float) 28 Tri-State(Single Float) 29 Tri-State(Single Float) 30 Tri-State(Single Float) 31 Tri-State(Single Float) 32 Tri-State(Single Float) 33 Tri-State(Single Float) 34 Tri-State(Single Float) 35 Tri-State(Single Float) 36 Tri-State(Single Float) 37 Tri-State(Single Float) 38 Tri-State(Single Float) 39 Tri-State(Single Float) 40 Tri-State(Single Float) 41 Tri-State(Single Float) 42 Tri-State(Single Float) 43 Tri-State(Single Float) 44 Tri-State(Single Float) 45 Tri-State(Single Float) 46 Tri-State(Single Float) 47 Tri-State(Single Float) 48 Tri-State(Single Float) 49 Tri-State(Single Float) 50 Tri-State(Single Float) 51 Tri-State(Single Float) 52 Tri-State(Single Float) 53 Tri-State(Single Float) 54 Tri-State(Single Float) 55 Tri-State(Single Float) 56 Tri-State(Single Float) 57 Tri-State(Single Float) 58 Tri-State(Single Float) 59 Tri-State(Single Float) 60 Tri-State(Single Float) 61 Tri-State(Single Float) 62 Tri-State(Single Float) 63 Tri-State(Single Float) 64 Tri-State(Single Float) 65 Tri-State(Single Float) 66 Tri-State(Single Float) 67 Tri-State(Single Float) 68 Tri-State(Single Float) 69 Tri-State(Single Float) 70 Tri-State(Single Float) 71 Tri-State(Single Float) 72 Tri-State(Single Float) 73 Tri-State(Single Float) 74 Tri-State(Single Float) 75 Tri-State(Single Float) 76 Tri-State(Single Float) 77 Tri-State(Single Float) 78 Tri-State(Single Float) 79 Tri-State(Single Float) 80 Tri-State(Single Float) 81 Tri-State(Single Float) 82 Tri-State(Single Float) 83 Tri-State(Single Float) 84 Tri-State(Single Float) 85 Tri-State(Single Float) 86 Tri-State(Single Float) 87 Tri-State(Single Float) 88 Tri-State(Single Float) 89 Tri-State(Single Float) 90 Tri-State(Single Float) 91 Tri-State(Single Float) 92 Tri-State(Single Float) 93 Tri-State(Single Float) 94 Tri-State(Single Float) 95 Tri-State(Single Float) 96 Tri-State(Single Float) 97 Tri-State(Single Float) 98 Tri-State(Single Float) 99 Tri-State(Single Float) +AAMAAQ- I21100 11/15/24 9:47 AM Menzies Aviation P.O.B. 22287 S.L.C., Utah 84122 801-531-4710 TANK CALIBRATION CHART +AAM-