HomeMy WebLinkAboutDERR-2024-012208APPLIED ENVIRONMENTAL SERVICES, L.C. PO BOX 1073 BOUNTIFUL, UTAH 84011 801-540-9258 TEI 5000 NON VOLUMETRIC, TEI 4000 VOLUMETRIC, TEI ULLAGE, TEI LT3 PRECISION TANK & LINE TEST RESULTS SUMMARY INVOICE ADDRESS:TANK LOCATION: WORK ORDER # TECH # 94027 TECHNICIAN: SM STATE TECH # SPACKMAN ENTERPRISES PO BOX 1276 CENTERVILLE, UTAH 84014 TAYLORSVILLE - BENNION IMP 1800 WEST 4700 SOUTH TAYLORSVILLE, UTAH 84118 24127 UT 0121 DATE: 10-25-2024 TIME START: 10:00 TIME END: 16:00 GROUNDWATER DEPTH: N/A DW TK TANK TANK CAPACITY 10065 10065 PRODUCT DSL R/UL TANK PASS PASS VENT PASS PASS PRODUCT LINE PASS PASS LINE LEAK DETECTOR PASS PASS WATER IN TANK 0.0" 0.0" PUMP TYPE PRESS PRESS TANK MATERIAL DWF DWF 1. 2. 3. 4. 5. 6. PRODUCT LINES TESTED AT 50 PSI FOR 15 MIN LINE RATES (GPH) 1. 2. 3. 5. 6. DSL -.002 R/UL -.001 ADDITIONAL INFORMATION:DOUBLEWALL FIBERGLASS COMPARTMENT TANK ( DRY SPACE ) CERTIFIED TECHNICIAN SIGNATURE:DATE:10-25-2024 These systems meet all requirements set forth by USEPA 40 CFR and has received third party certification. 4. TEST METHODS USED FOR THIS LOCATION TEI 5000 NON VOLUMETRIC TANK TEST TEI 4000 VOLUMETRIC TANK TEST TEI TANK ULLAGE TEST TEI LT3 LINE TESTXX X LINE LEAK DETECTOR TYPE & SIMULATED LEAK RATE 1. 2. 3. M = MECHANICAL E = ELECTRONIC # = (GPH) RATE 4. 5. 6. M 3 M 3 All tests were performed according to manufacturer protocol, and within the common practices of the industry. However due to the variables of tightness testing, these results cannot be guaranteed. There are no warranties expressed, written or implied. Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.10.26 12:36:53 -07'00' Reason: I am the author of this document TAYLORSVILLE - BENNION IMP DIST 1800 WEST 4700 SOUTH TAYLORSVILLE, UTAH 84118 4001824 TAYLORSVILLE - BENNION IMP DIST APPLIED ENVIRONMENTAL SERVICES 1800 WEST 4700 SOUTH TAYLORSVILLE, UTAH 84118 DAN MCDOUGAL 801-968-9081 801-540-9258 10-25-2024 1 DSL FE PETRO X 29 28 350 5 14 5 X X X X 2 R/UL FE PETRO X 26 25 250 2 14 2 X X X X STEVEN B MARTIN Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.10.26 12:41:08 -07'00' Reason: I am the author of this document UST OVERFILL EQUIPMENT INSPECTION AUTOMATIC SHUTOFF DEVICE AND BALL FLOAT VALVE Facility Name: Address: City, State, Zip Code: Facility I.D. # Testing Company: This data sheet is for inspecting automatic shutoff devices and ball float valves. See PEI/RP 1200, Section 7 for inspection procedures. Owner: Address: City, State, Zip Code: Phone# Tester Phone# Product Grade: Tank Number: Tank Volume, gallons: Tank Diameter, inches: Overfill Prevention Device Brand: Overfill Type AUTOMATIC SHUTOFF DEVICE INSPECTION 1. Drop tube removed from tank? 2. Drop tube and float mechanisms are free of debris? 3. Float moves freely without binding and poppet moves into flow path? 4. Bypass valve in the drop tube is open and free of blockage (if present)? 5. Flapper is adjusted to shut off flow at 95% ?* A "NO" to any item in Lines 1-5 indicates a test failure. BALL FLOAT VALVE INSPECTION * * 1. Tank top fittings are vapor-tight and leak free? 2. Ball float cage free of debris? 3. Ball free of holes and cracks and moves freely in cage? 4. Vent hole in pipe open and near top of tank? 5. Ball float pipe is proper length to restrict flow at 90% capacity?*** A "NO" to any item in Lines 1-5 indicates a test failure. Test Results: * Use manufacturer's suggested proceedure for determining if automatic shutoff device will shut off flow at 95% capacity. Tester's Name: TAYLORSVILLE - BENNION INPROVMENT DIST 1800 WEST 4700 SOUTH TAYLORSVILLE, UTAH 84118 4001824 AES UTAH LICENCE # UT 0121 TAYLORSVILLE - BENNION INP 1800 WEST 4700 SOUTH TAYLORSVILLE, UTAH 84118 DAN MCDOUGAL 801-968-9081 801-540-9258 Date: 11-1-2024 DSL 1 10065 119 3/8 OPW 71SO AUTOMATIC YES YES YES YES R/UL 2 10065 119 3/8 OPW 71SO AUTOMATIC YES YES YES YES Steven B. Martin Testers Signature: * * If a ball float is found to fail the inspection , another method of overfill must be used. * * * Use manufacturer's suggested procedure for determining if flow restriction device will restrict flow at 90% capacity. Comments PASS PASS Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.11.02 15:33:48 -07'00' Reason: I am the author of this document TAYLORSVILLE - BENNION INP 1800 WEST 4700 SOUTH TAYLORSVILLE, UTAH 84118 4001824 APPLIED ENVIRONMENTAL SERVICES TAYLORSVILLE - BENNION INP 1800 WEST 4700 SOUTH TAYLORSVILLE, UTAH 84118 DAN MCDOUGAL 801-968-9081 801-540-9258 11-1-2024 TK INT DSL / R/UL X X X X X X X X DISP SUMP DSL / R/UL X X X X X X X X DSL STP DSL X X X X X X X X R/UL STP R/UL X X X X X X X X XEREX DOUBLE WALL TWO COMPARTMENT UST WITH DRY SPACE INTERSTICIAL STEVEN B MARTIN APPLIED ENVIRONMENTAL SERVICES, L.C. PO BOX 1073 BOUNTIFUL, UTAH 84011 801-540-9258 AESUTAH@AOL.COM Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.11.02 15:48:20 -07'00' Reason: I am the author of this document AUTOMATIC TANK GAUGE OPERATION INSPECTION Facility Name: Address: City, State, Zip Code: Facility I.D. # Testing Company: Owner: Address: City, State, Zip Code: Phone # Testers Phone # Date: This procedure is to determine whether the ( ATG) is operating properly. See PEI/RP1200 Section 8.2 for the proper inspection procedure. Tank Number Product Stored: ATG Brand and Model 1. Tank Volume, gallons 2. Tank Diameter, inches 3. After removing the ATG from the tank, has it been inspected and any damaged or missing parts replaced? 4. Float moves freely on the stem without 5. Fuel float level agrees with the value programmed into the console? 6. Water float level agrees with the value programmed into the console? 7. Inch level from bottom of stem when 90% alarm is triggered. 8. Inch level at which the overfill alarm activates corresponds with value programmed in the gauge? 9. Inch level from the bottom when the water float first triggers an alarm. 10. Inch level at which the float alarm activates corresponds with value programmed in the gauge? If any answers in Lines 3,4,5, or 6 are "NO" the system has failed the test. TEST RESULTS Comments: Testers Name: Steven B. Martin Testers Signature: TAYLORSVILLE -BENNION INP 1800 WEST 4700 SOUTH TAYLORSVILLE, UTAH 84118 4001824 AES UTAH TESTER # UT 0121 TAYLORSVILLE - BENNION INP 1800 WEST 4700 SOUTH TAYLORSVILLE, UTAH 84118 DAN MCDOUGAL 801-968-9081 801-540-9258 11-1-2024 1 DSL VEED TLS4 10065 119.3 YES YES YES YES 99 3/4 YES 2.0 YES 2 R/UL VEED TLS4 10065 119.3 YES YES YES YES 99 3/4 YES 2.0 YES PASS PASS XEREX DOUBLE WALL COMPARTMENT TANK ALL SENSORS FUNCTION NORMALLY SETUP REPORT PRINTED Digitally signed by STEVEN B MARTIN cn=STEVEN B MARTIN, o=AES, c=US Date: 2024.11.02 18:49:11 -07'00' Reason: I am the author of this document