Loading...
HomeMy WebLinkAboutDAQ-2024-011526 1 DAQC-1130-24 Site ID 10238 (B5) MEMORANDUM TO: FILE – PACIFICORP – Huntington Power Plant THROUGH: Harold Burge, Major Source Compliance Section Manager FROM: Rob Leishman, Environmental Scientist DATE: November 7, 2024 SUBJECT: PacifiCorp Huntington Power Plant (Huntington), Major, NSPS, Title V, Emery County FRS # UT00000049001501001 INSPECTION TYPE: State Electronic Data Report (SEDR) Review REVIEW DATE: November 7, 2024 SOURCE LOCATION: Huntington Canyon/Emery County SOURCE CONTACT: Russ Wilson – 435-687-4331 APPLICABLE REGULATIONS: Title V Operating Permit PERMIT NUMBER: 1501001005 DATE OF PERMIT: January 22, 2020 Date of Last Revision: August 26, 2021 SOURCE INSPECTION EVALUATION: With the exception of sources that only monitor for opacity, quarterly report memoranda will only address the findings of the quarterly report. Approval Order and Title V permit conditions addressing continuous emission monitoring requirements will be addressed in Huntington’s relative accuracy performance specification test review memorandum. SOURCE REVIEW EVALUATION: Third Quarter 2024 % Monitor Availability (MA) Performance Test Dates (N/A to Opacity) Summary of Excess Emissions During Point Source Operation Point Source Op. hrs. Channel MA CGA Lin RATA Point Source Channel Hrs. Limitation 1 2207 SO2 100% 08/05/24 04/30/24 1 SO2 0.00 0.12 lb/MMBtu - 30 DRA 1 2207 NOx 100% 08/05/24 04/30/24 1 SO2 0.00 595 (lb/hr) - 30 DRA 1 2207 CO2 100% 08/05/24 04/30/24 1 SO2 0.00 0.2 lb/MMBtu - 30 DRA 1 8 2 2 Third Quarter 2024 % Monitor Availability (MA) Performance Test Dates (N/A to Opacity) Summary of Excess Emissions During Point Source Operation Point Source Op. hrs. Channel MA CGA Lin RATA Point Source Channel Hrs. Limitation 1 2207 Opacity 100% 1 NOx 0.00 0.26 lb/MMBtu - 30 DRA 1 2207 CO 100% 08/05/24 04/30/24 1 NOx 0.00 1290 (lb/hr) - 30 DRA 2 2207 SO2 99% 08/05/24 04/11/24 1 Opacity 0.00 20 Percent - 6 min 2 2207 NOx 99% 08/05/24 04/11/24 1 CO 0.00 0.34 lb/MMBtu - 30 DRA 2 2207 CO2 99% 08/05/24 04/11/24 1 CO 0.00 1686 (lb/hr) - 30 DRA 2 2207 Opacity 99% 2 SO2 0.00 0.12 lb/MMBtu - 24 hr Block 2 SO2 0.00 0.2 lb/MMBtu - 30 DRA 2 NOx 0.00 0.26 lb/MMBtu - 30 DRA 2 Opacity 0.00 20 Percent - 6 min Excess Emission Report - Hourly Summary Point Source Channel Startup & Shutdown Control Equipment Problems Process Problems Other Known Causes Unknown Causes Emission Limit 1 SO2 0 0 0 0 0 0.12 lb/MMBtu - 30 DRA 1 SO2 0 0 0 0 0 595 (lb/hr) - 30 DRA 1 SO2 0 0 0 0 0 0.2 lb/MMBtu - 30 DRA 1 NOx 0 0 0 0 0 0.26 lb/MMBtu - 30 DRA 1 NOx 0 0 0 0 0 1290 (lb/hr) - 30 DRA 1 Opacity 0 0 0 0 0 20 Percent - 6 min 1 CO 0 0 0 0 0 0.34 lb/MMBtu - 30 DRA 1 CO 0 0 0 0 0 1686 (lb/hr) - 30 DRA 2 SO2 0 0 0 0 0 0.12 lb/MMBtu - 24 hr Block 2 SO2 0 0 0 0 0 0.2 lb/MMBtu - 30 DRA 2 NOx 0 0 0 0 0 0.26 lb/MMBtu - 30 DRA 2 Opacity 0 0 0 0 0 20 Percent - 6 min CMS Performance Summary - Hourly Summary Point Source Channel Monitor Malfunction Non-monitor Malfunction QA Calibrations Other Known Causes Unknown Causes 1 SO2 0 0 0 2 0 1 NOx 0 0 0 2 0 1 CO2 0 0 0 2 0 3 CMS Performance Summary - Hourly Summary Point Source Channel Monitor Malfunction Non-monitor Malfunction QA Calibrations Other Known Causes Unknown Causes 1 Opacity 0 0 10 0 0 1 CO 0 0 0 0 0 2 SO2 0 14 0 3 0 2 NOx 0 17 0 3 0 2 CO2 0 14 0 3 0 2 Opacity 2 0 9 3 0 Type Code 280 (COMS Attenuator Filters) Procedure 3 Point Source & Location Attenuator I.D. Attenuator Certification Date Certified Attenuator Opacity OPLR, SECR, or PLCF Corrected Opacity Value Range Low, Mid, & High Certification 1-year or 5-year 1 - A ZN-47 3/20/24 13.60 0.63 16.82 L 1 1 - A YN-39 3/20/24 19.00 0.63 23.34 M 1 1 - A TX-32 3/20/24 36.70 0.63 43.91 H 1 1 - B ZN-47 3/20/24 13.60 0.63 16.82 L 1 1 - B YN-39 3/20/24 19.00 0.63 23.34 M 1 1 - B TX-32 3/20/24 36.70 0.63 43.91 H 1 2 - 2 ZP-04 3/20/24 29.50 0.25 15.73 L 1 2 - 2 ZR-19 3/20/24 43.70 0.25 24.53 M 1 2 - 2 TX-33 3/20/24 59.30 0.25 35.62 H 1 Type Code 281 (Procedure 3 - COMS Filter Audit Calibration Error) Point Source Location Audit Date Opacity Monitor Response (Average of 5) Mean Difference Calibration Error (≤ 3%) Low Mid High 1 A 9/18/24 17 0.250 1 A 9/18/24 23 0.060 1 A 9/18/24 44 0.060 1 B 9/24/24 17 -0.150 1 B 9/24/24 23 0.030 1 B 9/24/24 44 0.010 2 2 9/11/24 16 0.120 2 2 9/11/24 25 -0.030 2 2 9/11/24 35 -0.220 4 Type Code 282 (Annual Zero Alignment Audit) Procedure 3 Point Source Location Audit Date Alternative Zero Alignment (Yes or No) COM Clear Condition Zero Response (CCZR) COM Simulated Zero Response (CSZR) Zero Alignment Error Difference (CCZR)- (CSZR) Adjustment to COM Simulated Zero Response (CSZR) (Yes or No) 1 A 9/18/24 yes -0.20 0 0 yes 1 B 9/24/24 yes 0.00 0 0 yes 2 2 9/11/24 yes 0.10 0 0 yes Pollutant Concentration Exceeded Span of CEM Monitor Outage During Point Source Operation Alternate Sampling CEM Modifications 0 Hours 83 Hours 0 Hours 0 Events SOURCE INSPECTION SUMMARY EVALUATION: Huntington maintains its CEMS as required in R307-170 and 40 CFR 60.13. CURRENT RECOMMENDATIONS: All deviations appear to be a result of breakdown or process related problems that do not warrant issuing a violation. Huntington was in compliance during this reporting period. No further compliance action is recommended. Huntington’s NSPS monitoring system meets the performance standards of 40 CFR 60, Appendix B Performance Specifications. Huntington’s acid rain monitoring system meets the performance standards of 40 CFR 75 Acid Rain Performance Specifications. Periods of excess emissions that were recorded by the CMS in service on each point source during this reporting period are summarized in the SEDR and described in Pivot Table 400 “Excess Emissions Review.” HIGH PRIORITY VIOLATOR (HPV): No RECOMMENDATION FOR NEXT INSPECTION: Check DAS for daily zero and span drift. Check the QC program to ensure that monitor drift is being tracked and that the source can identify excessive drift. ATTACHMENTS: Excel spreadsheet review Pacificorp Huntington EER 3Q2024 Point Source Information Late Expired Cal. Gas Valid Cal. Gas Days Yes No 1 Type Code 100 (Company Information)Type Code Company Manager Company Name AIRS # Phone Number Environmental Contact 1 100 Laren Huntsman 01501001 435-687-4000 Russ Willson 1 100 0 0 0 0 1 Type Code 110 (Point Source Identification)Type Code Point Source Quarter 1 - 4 Year Point Source Operating Hrs. in Quarter 1 110 3 2024 2207.98 1 110 3 2024 2207.96 1 110 0 0 0 1 Type Code 200 (Monitor Identification)Type Code Point Source Channel Manufacturer Model No. Monitor SN Low Span High Span Installation Date Monitor Location 1 200 CO THERMO 48iQ-ACN 12108511485 0 1000 6/15/2021 Stack 1 200 CO2 THERMO 410iQ-ACN 12108511478 0 20 6/15/2021 Stack 1 200 NOx THERMO 42iQ-ACANN 12108511481 0 300 6/15/2021 Stack 1 200 Opacity Land Instr. 4500 MkIII 232342 81 0 100 10/11/2018 Scrubber Inlet Duct A - stack 1 200 Opacity Land Instr. 4500 MkIII 236573 83 0 100 10/11/2018 Scrubber Inlet Duct B - stack 1 200 SO2 THERMO 43iQ-ACN 12108511483 0 800 6/15/2021 Stack 1 200 CO2 THERMO 410iQ-ACN 12108511479 0 20 6/17/2021 Stack 1 200 NOx THERMO 42iQ-ACANN 12108511480 0 300 6/17/2021 Stack 1 200 Opacity Land Instr. 4500 MkIII 241977 92 0 100 10/15/2019 Inlet Duct - 1 200 SO2 THERMO 43iQ-ACN 12108511482 0 800 6/17/2021 Stack 1 200 0 0 0 0 0 0 1/0/1900 0 1 Type Code310 (Excess Emissions) SUMMARY REPORT Type Code Channel Total Hours of Excess Emissions Excess Emissions - % of Total Operating Hours RC 701 Hours - start up/Shutdown RC 702 Hours- Control Equipment Problems RC 703 Hours - Process Problems RC 704, 706, 707 Hours -Other Known Causes RC 705 Hours - Unknown Causes Emission Limitation Emission Limitation Units Emission Limitation Averaging Period 1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 0.12 lb/MMBtu 30 DRA 1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 595 (lb/hr) 30 DRA 1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 0.2 lb/MMBtu 30 DRA 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 0.26 lb/MMBtu 30 DRA 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 1290 (lb/hr) 30 DRA 1 TRUE 310 Opacity 0 0.00% 0 0 0 0 0 20 Percent 6 min 1 TRUE 310 CO 0 0.00% 0 0 0 0 0 0.34 lb/MMBtu 30 DRA 1 TRUE 310 CO 0 0.00% 0 0 0 0 0 1686 (lb/hr) 30 DRA 1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 0.12 lb/MMBtu 24 hr Block 1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 0.2 lb/MMBtu 30 DRA 1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 0.26 lb/MMBtu 30 DRA 1 TRUE 310 Opacity 0 0.00% 0 0 0 0 0 20 Percent 6 min 1 310 0 0 0 0 0 0 0 0 0 1 Type Code 300 (CMS Performance Summary) Type Code Channel Point Source Operating Hours Downtime - % of Total Operating Hours Total CMS Downtime RC 721 Hours - Monitor Malfunction RC 722 Hours - Non-monitor Malfunction RC 723 Hours - QA Calibrations RC 724 Hours - Other Known Causes RC 725 Hours - Unknown Causes 1 TRUE 300 SO2 2207.98 0.09% 2 0 0 0 2 0 1 TRUE 300 NOx 2207.98 0.09% 2 0 0 0 2 0 1 TRUE 300 CO2 2207.98 0.09% 2 0 0 0 2 0 1 TRUE 300 Opacity 2207.98 0.47% 10.4 0 0.3 10.1 0 0 1 TRUE 300 CO 2207.98 0.00% 0 0 0 0 0 0 1 TRUE 300 SO2 2207.96 0.77% 16.9 0 13.9 0 3 0 1 TRUE 300 NOx 2207.96 0.90% 19.9 0 16.9 0 3 0 1 TRUE 300 CO2 2207.96 0.77% 16.9 0 13.9 0 3 0 1 TRUE 300 Opacity 2207.96 0.64% 14.1 1.7 0.4 8.8 3.2 0 1 300 0 0 0 0 0 0 1 Type Code 250 (Performance Specification RATA Results) Type Code Channel Date of Most Current RATA Date of Preceding RATA Months Between RATA's Units of Measurement CEM Value Reference Method Value Relative accuracy Pass/ Fail 1 383 Days 250 SO2 04/30/24 04/13/23 12.59 #/MMBtu,CO2dil. 0.086 0.088 3.70% Pass 1 383 Days 250 NOx 04/30/24 04/13/23 12.59 #/MMBtu,CO2dil. 0.238 0.236 1.50% Pass 1 383 Days 250 CO2 04/30/24 04/13/23 12.59 Percent 10.5 10.3 2.50% Pass 1 383 Days 250 CO 04/30/24 04/13/23 12.59 #/MMBtu,CO2dil. 0.078 0.075 15.00% Pass 1 383 Days 250 CO 04/30/24 04/13/23 12.59 #/hr 368.4 350.9 17.50% Pass 1 364 Days 250 CO2 04/11/24 04/13/23 11.97 Percent 11.3 11.1 1.80% Pass 1 364 Days 250 NOx 04/11/24 04/13/23 11.97 #/MMBtu,CO2dil. 0.191 0.197 3.80% Pass 1 364 Days 250 SO2 04/11/24 04/13/23 11.97 #/MMBtu,CO2dil. 0.043 0.044 2.30% Pass 1 0 Days 250 0 01/00/00 01/00/00 0 0 0 0 0.00% 0 Point Source Point Source Point Source 1 2 0 2 2 0 1 1 1 1 1 2 2 2 2 2 1 1 1 PacifiCorp Huntington 0 1 1 1 1 1 1 2 2 2 2 0 1 1 1 2 2 1 1 0 2 0 1 1 1 1 2 1 Pacificorp Huntington EER 3Q2024 1 Type Code 260 (CGA Results)Type Code Channel Date Audit Point No. Cylinder ID Cylinder Expiration Date Type of Certification Units of Measurement CEM Value Cylinder Value Precision %Pass/ Fail Range - High or Low 1 Valid Cal. Gas 260 CO 08/05/24 low CC503538 07/01/28 0 ppm 258.9 262.2 -1.20% Pass 0 1 Valid Cal. Gas 260 CO 08/05/24 mid DT0045681 07/09/28 0 ppm 566.1 559 1.30% Pass 0 1 260 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0 1 Type Code 270 (Linearity Test Results)Type Code Channel Date Audit Point No. Cylinder ID Cylinder Expiration Date Type of Certification Units of Measurement CEM Value Cylinder Value Precision %Pass/ Fail Range - High or Low 1 Valid Cal. Gas 270 CO2 08/05/24 low DT0014833 07/10/32 P1 percent 5 5 0.00% Pass 0 1 Valid Cal. Gas 270 CO2 08/05/24 mid CC328446 07/10/32 P1 percent 10.9 11.1 1.50% Pass 0 1 Valid Cal. Gas 270 CO2 08/05/24 high CC30779 07/16/32 P1 percent 18.3 18.1 0.90% Pass 0 1 Valid Cal. Gas 270 NOx 08/05/24 low DT0014833 07/10/32 P1 ppm 79.3 76.9 3% Pass 0 1 Valid Cal. Gas 270 NOx 08/05/24 mid CC328446 07/10/32 P1 ppm 156.5 159 2% Pass 0 1 Valid Cal. Gas 270 NOx 08/05/24 high CC30779 07/16/32 P1 ppm 273 270 1% Pass 0 1 Valid Cal. Gas 270 SO2 08/05/24 low DT0014833 07/10/32 P1 ppm 205.9 205.7 0.10% Pass High 1 Valid Cal. Gas 270 SO2 08/05/24 mid CC328446 07/10/32 P1 ppm 423 429.9 1.60% Pass High 1 Valid Cal. Gas 270 SO2 08/05/24 high CC30779 07/16/32 P1 ppm 690 717 3.80% Pass High 1 Valid Cal. Gas 270 CO2 08/05/24 low DT0014833 07/10/32 P1 percent 4.9 5 2.00% Pass 0 1 Valid Cal. Gas 270 CO2 08/05/24 mid CC328446 07/10/32 P1 percent 11.1 11.1 0.00% Pass 0 1 Valid Cal. Gas 270 CO2 08/05/24 high CC30779 07/16/32 P1 percent 18.3 18.1 1.30% Pass 0 1 Valid Cal. Gas 270 NOx 08/05/24 low DT0014833 07/10/32 P1 ppm 79.5 76.9 3.40% Pass 0 1 Valid Cal. Gas 270 NOx 08/05/24 mid CC328446 07/10/32 P1 ppm 160.6 159 1.00% Pass 0 1 Valid Cal. Gas 270 NOx 08/05/24 high CC30779 07/16/32 P1 ppm 275.2 270 1.90% Pass 0 1 Valid Cal. Gas 270 SO2 08/05/24 low DT0014833 07/10/32 P1 ppm 208.6 205.7 1% Pass High 1 Valid Cal. Gas 270 SO2 08/05/24 mid CC328446 07/10/32 P1 ppm 430.1 429.9 0% Pass High 1 Valid Cal. Gas 270 SO2 08/05/24 high CC30779 07/16/32 P1 ppm 697.7 717 3% Pass High 1 270 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0 1 Type Code 210 (Pollutant Concentration Exceeded Span of CEM) Type Code Channel Start Date Start Time End Date End Time Hours 1 0 0 0 1/0/00 0:00 1/0/00 0:00 1 1 None Reported 1 0 TC 220 Hours 83.00 TC 220 Hours 0.00 TC 230 Hours 0.00 Events 0.00 Hours 0.00 Events 0.00 0.00 1 84.20 TC 300 Hours 1.20 FALSE None Reported None Reported None Reported None Reported None Reported None Reported 2 2 2 Point Source Point Source Point Source Yes 1 1 Type Code 550 (Changes in Operation in Control Equipment When CEM Data Not Available) Type Code 500 (Boiler Operating Days w/o 18 Hours of Data) Type Code 450 (Data Excluded) Type Code 210 (Pollutant Concentration Exceeded Span of CEM) Type Code 220 (Monitor Outage During Point Source Operation) Type Code 230 (Manual Sample - Alternate Sampling During Monitor Outage) Type Code 240 (CEM Modifications) Type Code 530 (Excess Emissions During Emergency Conditions) 0 2 0 1 1 1 1 2 1 1 1 1 1 2 2 2 2 0 Pacificorp Huntington EER 3Q2024 Relative Accuracy Overview Point Source Channel Date of Most Current RATA Date of Preceding RATA Months Between RATA's Units Measured CEM Value Reference Method Value Relative Accuracy Pass/ Fail 2024 1 SO2 04/30/24 04/13/23 12.59 #/MMBtu,CO2dil.0.086 0.09 3.70% Pass 1 NOx 04/30/24 04/13/23 12.59 #/MMBtu,CO2dil.0.238 0.24 1.50% Pass 1 CO2 04/30/24 04/13/23 12.59 Percent 10.5 10.30 2.50% Pass 1 CO 04/30/24 04/13/23 12.59 #/MMBtu,CO2dil.0.078 0.08 15.00% Pass 1 CO 04/30/24 04/13/23 12.59 #/hr 368.4 350.90 17.50% Pass 2 CO2 04/11/24 04/13/23 11.97 Percent 11.3 11.10 1.80% Pass 2 NOx 04/11/24 04/13/23 11.97 #/MMBtu,CO2dil.0.191 0.20 3.80% Pass 2 SO2 04/11/24 04/13/23 11.97 #/MMBtu,CO2dil.0.043 0.04 2.30% Pass * NSPS CGA Third 2024 Audit Gas Ranges Audit Gas Ranges AP1 Low AP2 Low AP1 High AP2 High 1 CO 8/5/24 1000 262.2 200 to 300 1 CO 8/5/24 1000 559 500 to 600 * Acid Rain Audit Linearity Third 2024 Low Span Gas Ranges High Span Gas Ranges Low Mid High Low Mid High 1 CO2 8/5/24 20 5 4 to 6 1 CO2 8/5/24 20 11.1 10 to 12 1 CO2 8/5/24 20 18.1 16 to 20 1 NOx 8/5/24 300 76.9 60 to 90 1 NOx 8/5/24 300 159 150 to 180 1 NOx 8/5/24 300 270 240 to 300 1 SO2 8/5/24 800 205.7 160 to 240 1 SO2 8/5/24 800 429.9 400 to 480 1 SO2 8/5/24 800 717 640 to 800 2 CO2 8/5/24 20 5 4 to 6 2 CO2 8/5/24 20 11.1 10 to 12 2 CO2 8/5/24 20 18.1 16 to 20 2 NOx 8/5/24 300 76.9 60 to 90 2 NOx 8/5/24 300 159 150 to 180 2 NOx 8/5/24 300 270 240 to 300 2 SO2 8/5/24 800 205.7 160 to 240 2 SO2 8/5/24 800 429.9 400 to 480 2 SO2 8/5/24 800 717 640 to 800 * Audit Gas Used Point Source Channel Audit Date Low Span Point Source Channel Audit Date Low Span Audit Gas Used High Span Audit Gas Used High SpanAudit Gas Used Pacificorp Huntington EER 3Q2024 Type Code 280 (COMS Attenuator Filters) Procedure 3 Point Source Location Attenuator I.D. Attenuator Certification Date Certified Attenuator Opacity OPLR, SECR, or PLCF, Corrected Opacity Value Range Low, Mid, & High Certification 1-year or 5-year 1 A ZN-47 3/20/24 14 0.632 16.82 L 1 1 A YN-39 3/20/24 19 0.632 23.34 M 1 1 A TX-32 3/20/24 37 0.632 43.91 H 1 1 B ZN-47 3/20/24 13.6 0.632 16.82 L 1 1 B YN-39 3/20/24 19 0.632 23.34 M 1 1 B TX-32 3/20/24 36.7 0.632 43.91 H 1 2 2 ZP-04 3/20/24 29.5 0.245 15.73 L 1 2 2 ZR-19 3/20/24 43.7 0.245 24.53 M 1 2 2 TX-33 3/20/24 59.3 0.245 35.62 H 1 * Opacity Monitor Response (Average of 5) Low Range Mid Range High Range 1 A 9/18/24 17 0.250 0.030 0.070 0.000 1 A 9/18/24 23 0.060 0.000 0.000 0.000 1 A 9/18/24 44 0.060 0.060 0.140 0.000 1 B 9/24/24 17 -0.150 0.060 0.140 0.000 1 B 9/24/24 23 0.030 0.060 0.140 0.000 1 B 9/24/24 44 0.010 0.030 0.070 0.000 2 2 9/11/24 16 0.120 0.130 0.330 0.000 2 2 9/11/24 25 -0.030 0.170 0.430 0.000 2 2 9/11/24 35 -0.220 0.000 0.000 0.000 * Point Source Location Audit Date Alternitive Zero Alignment (Yes or No) COM Clear Condition Zero Response (CCZR) COM Simulated Zero Response (CSZR) Zero Alignment Error Difference (CCZR)-(CSZR) Adjustment to COM Simulated Zero Response (CSZR) (Yes or No) 1 A 9/18/24 yes -0.200 0.000 -0.200 yes 1 B 9/24/24 yes 0.000 0.000 0.000 yes 2 2 9/11/24 yes 0.100 0.000 0.100 yes Type Code 282 (Procedure 3 - Annual Zero Alignment Audit) Point Source Location Audit Date Mean Difference Standard Deviation Confidence Coefficient Calibration Error (≤ 3%) Type Code 281 (Procedure 3 - COMS Filter Audit Calibration Error) Pacificorp Huntington EER 3Q2024 Monitoring Information TC 210, 230, & 240 Type Code 210 (Pollutant Concentration Exceeded Span of CEM) - 500 (All) * Sum of Hours Column Labels Row Labels (blank) Grand Total (blank)0 0 Grand Total 0 0 * Type Code 230 (Manual Sample - Alternate Sampling During Monitor Outage) - 500 (All) * Sum of Hours Column Labels Row Labels (blank) Grand Total (blank)0 0 Grand Total 0 0 * Type Code 240 (CEM Modifications) - 100 (All) * Count of Channel Column Labels Row Labels (blank) Grand Total (blank) (blank) Grand Total Pacificorp Huntington EER 3Q2024 Type Code 220 (Monitor Outage During Point Source Operation) - 600 (All) * Sum of Hours Column Labels Row Labels 723 722 724 721 Grand Total 1 Opacity The monitor was unavailable during the daily monitor calibration as required by 40 CFR parts 60 and 75.7.67 7.67 A loss/interuption of power or communication to the DCS and/or monitor resulted in a loss of data. Power/communication was restored and the monitor was returned to service. 0.25 0.25 An opacity monitor filter check and/or audit was conducted followed by a manual calibration.2.47 2.47 NOx A daily calibration reference gas bottle was empty, resulting in a calibration fail. The bottle was changed and a second calibration initiated. 1.98 1.98 SO2 A daily calibration reference gas bottle was empty, resulting in a calibration fail. The bottle was changed and a second calibration initiated. 1.98 1.98 CO2 A daily calibration reference gas bottle was empty, resulting in a calibration fail. The bottle was changed and a second calibration initiated. 1.98 1.98 2 Opacity The monitor was unavailable during the daily monitor calibration as required by 40 CFR parts 60 and 75.7.58 7.58 A loss/interuption of power or communication to the DCS and/or monitor resulted in a loss of data. Power/communication was restored and the monitor was returned to service. 0.43 0.43 The monitor exhibited excessive drift. A calibration was initiated and upon successful completion the monitor was returned to service. 0.18 0.18 The monitor exhibited excessive drift. The optical surfaces were cleaned and stack sets were performed and the monitor was returned to service. 0.28 0.28 Opacity monitor was removed from service to repair/replace system components. Maintenance followed by a calibration.3.18 3.18 The opacity monitor displayed elevated opacity after passing a calibration due to a loose set screw on the upscale filter motor. The set screw was tightened and the monitor passed calibration with readings returned to normal. 1.18 1.18 A post outage start-up calibration was performed.1.18 1.18 NOx A loss/interuption of power or communication to the DCS and/or monitor resulted in a loss of data. Power/communication was restored and the monitor was returned to service. 4.97 4.97 A daily calibration reference gas bottle was empty, resulting in a calibration fail. The bottle was changed and a second calibration initiated. 1.98 1.98 A blockage in the calibration gas solonoid valve resulted in failed calibrations. The valve blockage was cleared and the system was returned to operation after a passing calibration. 2.98 2.98 A stuck solonoid valve allowed span gas to contaminate the system durnig the zero portion of the daily calibration resulting in an invalid calibration failure. The stuck solonoid valve was actuated and the monitor passed the daily calibration and returned to normal operation. 8.95 8.95 Maintenance of another monitor required normal sampling to be interrupted. The system was returned to service following the maintenance. 0.98 0.98 SO2 A loss/interuption of power or communication to the DCS and/or monitor resulted in a loss of data. Power/communication was restored and the monitor was returned to service. 1.98 1.98 A daily calibration reference gas bottle was empty, resulting in a calibration fail. The bottle was changed and a second calibration initiated. 1.98 1.98 A blockage in the calibration gas solonoid valve resulted in failed calibrations. The valve blockage was cleared and the system was returned to operation after a passing calibration. 2.98 2.98 A stuck solonoid valve allowed span gas to contaminate the system durnig the zero portion of the daily calibration resulting in an invalid calibration failure. The stuck solonoid valve was actuated and the monitor passed the daily calibration and returned to normal operation. 8.95 8.95 Maintenance of another monitor required normal sampling to be interrupted. The system was returned to service following the maintenance. 0.98 0.98 CO2 A loss/interuption of power or communication to the DCS and/or monitor resulted in a loss of data. Power/communication was restored and the monitor was returned to service. 1.98 1.98 A daily calibration reference gas bottle was empty, resulting in a calibration fail. The bottle was changed and a second calibration initiated. 0.98 0.98 A blockage in the calibration gas solonoid valve resulted in failed calibrations. The valve blockage was cleared and the system was returned to operation after a passing calibration. 2.98 2.98 A stuck solonoid valve allowed span gas to contaminate the system durnig the zero portion of the daily calibration resulting in an invalid calibration failure. The stuck solonoid valve was actuated and the monitor passed the daily calibration and returned to normal operation. 8.95 8.95 Maintenance of another monitor required normal sampling to be interrupted. The system was returned to service following the maintenance. 0.98 0.98 Grand Total 18.90 45.42 17.03 1.65 83.00 Pacificorp Huntington EER 3Q2024 Opy * Opy Count of Magnitude of Emissions Column Labels Opy Row Labels Grand Total Opy Grand Total SO2 * SO2 Type Code 410 (SO2) - 6000 (All) SO2 * SO2 Count of Magnitude of Emissions Column Labels SO2 Row Labels Grand Total SO2 Grand Total NOx * NOx Type Code 420 (NOx) - 6000 (All) NOx * NOx Count of Magnitude of Emissions Column Labels NOx Row Labels Grand Total NOx Grand Total NOx d * NOx d Type Code 421 (Daily NOx Emissions) - 500 (All) NOx d * NOx d Count of Reason Code Column Labels NOx d Row Labels (blank) NOx d 1 NOx d 0 NOx d 2 NOx d 0 NOx d Grand Total CO * CO Type Code 440 (CO) - 6000 (All) CO * CO Count of Magnitude of Emissions Column Labels CO Row Labels Grand Total CO Grand Total O2 * O2 Type Code 470 (TRS as O2) - 6000 (All) O2 * O2 Count of Magnitude of Emissions Column Labels O2 Row Labels Grand Total O2 Grand Total Pacificorp Huntington EER 3Q2024 Type Code 500 Before February 28, 2005 (Boiler Operating Days w/o 18 Hours of Data) After February 28, 2005 (90% Operating Hours For each 30 BOD) - 500 (All) * Count of Channel Column Labels Row Labels Grand Total Grand Total * Type Code 510 (F-factor, Equations & Conversion Factors) - 500 (All) Count of F-factor Column Labels Row Labels Grand Total Grand Total * Type Code 520 (Minimum Data Not Obtained <22/30 BODs) - 500 (All) Count of Channel Column Labels Row Labels Grand Total Grand Total * Type Code 530 (Excess Emissions During Emergency Conditions) - 500 (All) Count of Date Column Labels Row Labels Grand Total Grand Total * Type Code 540 (Fuel Pre-treatment Credit SO2) - 500 (All) Count of Date Column Labels Row Labels Grand Total Grand Total * TypeCode 550 (Changes in Operation in Control Equipment When CEM Data Not Available) - 500 (All) Column Labels Row Labels Grand Total Grand Total