Loading...
HomeMy WebLinkAboutDERR-2024-012113UST Annual Compliance Inspection Facility Information Name:Fast Stop 1104 Certification/Inspection #:54946 Address:4795 S 3500 W, Roy, UT, 84067 State ID:1200425 Phone Number:Form Completed By:Larry Vasquez Date:09/30/2024 Tank Information State Tank ID T3 DSL T4 ETH 88 T2 PUL T1 RUL Facility Tank # or ID (designation used by facility)T3 DSL T4 EHT 88 T2 PUL T1 RUL Tank Capacity 4706 gal 4706 gal 4706 gal 14881 gal Product Name (describe in comments if not listed)Diesel Ethanol Free Unleaded Premium Unleaded Compartment Only (mark only if NOT the entire tank) Manifolded Tank (mark for true siphon manifold ONLY) Tank Status* if Tank Status = TC:IU IU IU IU Date in TC (assessment & OPS extension required > 1yr) Emptied to 1" or less? (release detection required if not)Y N NA Y N NA Y N NA Y N NA Date emptied to 1" or less Tank Release Detection Method*ATG- Interstitial Monitoring ATG- Interstitial Monitoring ATG- Interstitial Monitoring ATG- Interstitial Monitoring Tank Corrosion protection*None None None None Tank Wall Type*FRP FRP FRP FRP Tank receives > 25 gallons at a time?Yes No Yes No Yes No Yes No Spill Bucket? (required where UST receives >25 gallons at a time)Yes No Yes No Yes No Yes No Spill Bucket Size Spill Bucket Wall Type* Overfill Protection? (required where UST receives >25 gallons at a time)Yes No Yes No Yes No Yes No Overfill Protection Type*External Overfill Alarm External Overfill Alarm External Overfill Alarm External Overfill Alarm Piping Corrosion protection*Flex-N/A Flex-N/A Flex-N/A Flex-N/A Flexible Connection - Tank*None None Flexible Connection - Dispenser* Piping Wall Type*DW DW DW DW Piping Delivery System*Pressure Pressure Pressure Pressure Line Leak Detector Type (required for PR system)*Mechanical Mechanical Mechanical Mechanical Piping Release Detection Method*Sump Sensor Monitoring Sump Sensor Monitoring Sump Sensor Monitoring Sump Sensor Monitoring STP (Turbine Pump) Containment Sump?Yes Yes Yes Yes STP Containment Sump Wall Type*SW SW SW SW UDC (Under-dispenser) Containment Sump?No No No No UDC Containment Sump Wall Type*NA NA NA NA Piping Transition Sumps?No No No No Transition Sump Wall Type*NA NA NA NA Comments Inspection Checklist For each facility, complete the Annual Compliance Inspection Checklist below by answering the questions. If the facility contains more than 5 tanks or 8 dispensers, additional copies of this form must be completed. Questions are designated as either a mandatory compliance item(●) or a recommended practice item(®). If an item is identified as mandatory and recommended, further information is provided in a note following the question. If "No" is the answer for any mandatory compliance item(●) question, an associated entry must be made in the Return to Compliance Plan with documentation of the date when the issue was brought back into compliance. The State must approve all compliance plan schedules. If "No" is the answer for a recommended practice item (®), it is strongly suggested that the deficiency be corrected. Tank Information Inspection Item T3 DSL T4 ETH 88 T2 PUL T1 RUL Fill Equipment ●1 Is there a product tag on the fill riser pipe or are the lids painted in accordance with a posted product code color chart? Y Y Y Y ®2 Does the fill cap have adequate clearance between the cap and the manhole cover? Y Y Y Y ●3 Does the tank have a drop tube that extends to within 6 inches of the bottom (if no diffuser is present)? Y Y Y Y Spill & Overfill Protection ●4 Is each UST that receives more that 25 gallons of product at any one time equipped with spill and overfill prevention? Y Y Y Y ●5 Is the spill bucket free of fuel, water or debris?Y Y Y Y ●6 Is the spill bucket in good condition and free of damage?Y Y Y Y ®7 Does the drain assembly work?NA NA NA NA ●8 Is the tank(s) equipped with an overfill device (e.g. overfill alarm, automatic shut-off device or ball-float valve) and is the device installed according to manufacturer's specifications to allow proper functionality? Y Y Y Y ●9 Is the tank overfill alarm mounted near the fill port where it can be seen or heard by the delivery person? Y Y Y Y Temporary Closure ●10 If the tank is in temporary closure and contains greater that 1 inch of product, is approved release detection performed and maintained? NOTE: OPS recommends that a tank in temporary closure be emptied (contains <= 1 inch of fluids). NA NA NA NA ●11 If the tank is in temporary closure, is corrosion protection maintained?NA NA NA NA ●12 If the tank has been in temporary closure for greater than 3 months, is the vent line open and has the piping, pumps, manways, and ancillary equipment been capped and secured? NA NA NA NA Vapor Recovery (if Required) ●13 Are the vapor recovery adaptor and cap present and free of damage?NA Y Y Y ®14 Does the vapor cap have adequate clearance between the cap and the manhole cover to enable hook-up? NA Y Y Y ®15 Is the vapor cap in good condition with a gasket?NA Y Y Y ®16 Is the vapor recovery lid painted orange?NA Y Y Y Submersible Turbine Pump (STP) Sump ®17 Are the external and/or internal lids easily removed for inspection?Y Y Y Y ®18 Are the sump lid, gasket and seals present and in good condition?Y Y Y Y ●19 Is the sump free of fuel, water or debris?Y Y Y Y ●20 Is the sump free of cracks, holes, bulges, or other defects?Y Y Y Y ●21 If the system contains secondarily contained piping with release detection consisting of sump sensors installed in the sump, is the interstice open to the sump? Y Y Y Y ●22 Is the sump sensor properly mounted at the bottom of the sump and operating according to the manufacturer's specifications? Y Y Y Y ●23 Are penetration fittings and entry boots intact, secure and free of damage? NOTE: If the sump was installed prior to 8-1-08 and is not used for interstitial monitoring, this is a recommended item. Y Y Y Y ®24 Are junction boxes sealed and free of corrosion?Y Y Y Y ●25 Are the STP components, piping and flex connectors free of leaks or seeps?Y Y Y Y ●26 If no sump is present, are metal components that are in contact with the soil cathodically protected? Y Y Y Y ●27 Are piping and flexible connectors installed according to the manufacturer's specifications (not kinked or twisted)? Y Y Y Y ●28 Did the mechanical and/or electronic line-leak detector pass its annual functionality test which includes a leak simulated in the line as part of the functionality test? Y Y Y Y ®29 Is the mechanical leak detector properly vented? (vent tube not kinked or twisted) Y Y Y Y ATG Port ®30 Is the manhole cover in good condition and is there adequate clearance between the ATG probe cap and the manhole cover? Y Y Y Y ®31 Is the cap in good condition and does it seal tightly?Y Y Y Y ®32 Are the probe wiring hole, electrical junction box and conduit sealed and in good condition? Y Y Y Y ●33 Are the probe, floats, and water/product warning alarms operating according to the manufacturer's specifications? Y Y Y Y ATG Console ●34 Does the ATG console have power?Y Y Y Y ●35 Have all ATG leak alarms been properly addressed?Y Y Y Y ●36 Is the console programmed correctly for the tanks found at the site (e.g. product, capacity, points, overfill alarm, in-tank test, line-leak detector test, etc.)? Y Y Y Y ●37 Is the sump sensor properly mounted at the bottom of the sump?Y Y Y Y ●38 Are the sensors functioning according to the manufacturer's specifications?Y Y Y Y Tank Interstice ●39 Are the interstitial sensors placed correctly in the tanks?Y Y Y Y ●40 Are the interstitial sensors functioning according to the manufacturer's specifications? Y Y Y Y Cathodic Protection ●41 Are all system components that routinely contain product (tanks, lines, and other metal components) and that are in contact with the soil properly cathodically protected? NA NA NA NA ●42 Has your cathodic protection system (galvanic anodes or impressed current) been tested within 6 months of installation/repair, and every 3 years thereafter? NA NA NA NA ●43 Has the impressed current system (rectifier) been inspected for proper operation at least every 60 days? NA NA NA NA ●44 If you have an internally-lined tank without additional cathodic protection, has it passed and internal inspection within 10 years after installation of the lining and every 5 years thereafter? NA NA NA NA ®45 If the system is equipped with impressed current, there are no damaged, frayed or exposed wires? NA NA NA NA Vent Piping ®46 Is the vent cap present and is it the correct type?Y Y Y Y ●47 Is the vent piping of correct height and above obstructions?Y Y Y Y ●48 Are diesel and gasoline tanks vented with separate piping?Y Y Y Y Unattended Fueling ●49 Is one or more clearly identified emergency shutoff devices located not less than 20 ft. or more than 100 ft. from the dispensing devices, readily accessible to patrons? Y Y Y Y 6 ●50 Is a working telephone or other approved, clearly identified means to notify the fire department provided on the site, and readily accessible to patrons? Y Y Y Y ●51 Is a fire extinguisher with a minimum rating of 40-B, a maintenance inspection not older than 1 year, and located no more than a 30 ft, travel distance from the dispensing devices, readily accessible to patrons? N N N N Monthly Inspection ●52 Have all Monthly inspections been performed and documented, and have all deficiencies noted during the inspections been corrected? Y Y Y Y Dispenser Information Inspection item D1 D2 D3 D4 D5 D6 ●53 Is hanging hardware free of visible signs of leakage or damage?Y Y Y Y Y Y ●54 Are all components of hanging hardware of the proper type and size?Y Y Y Y Y Y ●55 If applicable, is fuel product, safety, octane, diesel sulfur, ethanol, signage present and correct?Y Y Y Y Y Y ●56 Is the under-dispenser containment(UDC) sump free of fuel, water or debris?Y Y Y Y Y Y ●57 Is the UDC sump free of cracks, holes, bulges, or other defects?Y Y Y Y Y Y ®58 Are penetration fillings and entry boots intact, secure and free of damage? NOTE: If the sump was installed prior to 8-1-2008 and is not used for interstitial monitoring, this is a recommended item. Y Y Y Y Y Y ●59 If the system contains secondarily contained piping with release detection consisting of sump sensors installed in the sump, is the interstice open to the sump? Y Y Y Y Y Y ●60 Is the sump sensor properly mounted at the bottom of the sump?Y Y Y Y Y Y ●61 Are junction boxes sealed and free of corrosion?Y Y Y Y Y Y ●62 Are meters, piping and flexible connectors free of leaks or seeps?Y Y Y Y Y Y ●63 Are piping and flexible connectors installed according to the manufacturer's specification? (not kinked or twisted) Y Y Y Y Y Y ●64 If no UDC, are any metal piping components in contact with the soil properly cathodically protected?Y Y Y Y Y Y ●65 Are the shear valves operating according to the manufacturer's specifications?Y Y Y Y Y Y ●66 Is at least one fire extinguisher with a minimum rating of 40-B, and a maintenance inspection not older than 1 year, located within 100 feet of each dispenser and tank fill opening? Y Y Y Y Y Y ●67 Is an emergency stop button present and operable?Y Y Y Y Y Y Note: Deficiency Information Rec Item Item ID Equip ID Description Remedy Date Image ®51 T1 RUL Fire Extinguisher Not Within 30 Feet and Doesn't have access to predestines. ®51 T2 PUL Fire Extinguisher Not Within 30 Feet and Doesn't have access to predestines. ®51 T4 ETH 88 Fire Extinguisher Not Within 30 Feet and Doesn't have access to predestines. ®51 T3 DSL Fire Extinguisher Not Within 30 Feet and Doesn't have access to predestines. Operator Certification By signing below, the operator certifies that the answers above are accurate and based upon performance of associated inspection activities, and that the facility owner has received a copy of this inspection form. Contractor Printed Name:Larry Vasquez Contractor Company Name:CGRS, Inc. Certification Number: Contractor Signature: A or B Operator Printed Name:A or B Operator Cert. No.: A or B Operator Signature:Date:09/30/2024 AST Annual Compliance Inspection Facility Information Name:Fast Stop 1104 Certification/Inspection #:54947 Address:4795 S 3500 W, Roy, UT, 84067 State ID:1200425 Phone Number:Form Completed By:Larry Vasquez Date:09/30/2024 Tank Information State Tank ID T5 ETH 91 Facility Tank # or ID (designation used by facility) Tank Capacity 1000 gal Product Name (describe in comments if not listed)Ethanol Free Unleaded Compartment Only (mark only if NOT the entire tank) Item#T5 ETH 91 Containment ●1 Is the containment structure in satisfactory condition (diking, impounding, double-wall tank, etc)?Y ●2 Are the drainage pipes/valves in good working condition for continued service?Y Tank Foundation/Supports ®3 Free of tank settlement or foundation washout?Y ●4 Concrete pad or ring wall free of cracking or spalling?Y ●5 Tank supports in satisfactory condition?Y ●6 Is water able to drain away from tank?Y ●7 Is the grounding strap between the tank and foundation/supports in good condition?Y Cathodic Protection ®8 Are cathodic protection system in operating condition and functional?NA ●9 Rectifier readings: Volts ●10 Rectifier readings: Amps ●11 Are these readings within manufacturer specifications?NA Tank External Coating ●12 Tank shell/head free of visible signs of paint failure?Y Tank Shell/Heads ●13 Tank shell/head free of noticeable distortions, buckling, denting or buldging?Y ●14 Tank shell/head free of visible signs of corrosion or cracking?Y Tank Manways,Piping and Equipment ®15 Is aboveground piping free of leaks?Y ®16 Are required valves present?Y ®17 Are valves,installed correctly, operating correctly, free of damage,and free of leaks?Y ®18 Are the spill containment boxes on the fill pipes free of damage, or wear that compromise the integrity of the unit Y ®19 If no sump is present, are metal components that are in contact with the soil cathodically protected?NA ●20 Did the mechanical and/or electronic line-leak detector pass its annual functionality test which includes a leak simulated in the line as part of the functionality test? Y ●21 Is the mechanical leak detector properly vented? (vent tube not kinked or twisted)Y Tank Roof ●22 Roof is free of standing water?Y ●23 Roof is free of visible signs of coating cracking, crazing, peeling or blistering?Y ●24 Roof is free of holes?Y Venting ®25 Normal and emergency vents free of obstructions?Y ●26 Normal vent on tanks storing gasoline equipped with pressure/vacuum vent cap?Y ●27 Is the emergency vent in good working condition and functional, and tested as required by manufacturer?Y Insulated Tanks ●28 Free of missing insulation?Y ●29 Insulation free of noticeable areas of moisture?Y ®30 Insulation free of mold?Y ®31 Insulation free of visible signs of damage?Y ®32 Insulation adequately protected from water intrusion?Y Level and overfill Prevention Equipment ®33 Electronic or mechanical liquid level gauge tested for proper operation?Y ●34 Electronic or mechanical liquid level gauge calibrated during the previous 12 months?Y ●35 Is overfill prevention equipment in good working condition?Y ●36 Overfill prevention equipment type:Audible Alarm ●37 Overfill prevention equipment operational and in good condition?Y ●38 Is tank ullage being determined and documented before filling the tank?Y Electrical Equipment ●39 Is electrical equipment grounding adequate and in good condition?Y ●40 Is electrical wiring for control boxes, lights, and other high voltage equipment in good condition?Y Tank/Piping Release Detection ●41 Is inventory control being performed and documented as required?Y ●42 Is release detection being performed and documented on underground piping as required?Y Tank Interstice ●43 Is interstice free of liquid?NA ●44 Is interstitial monitoring equipment in good working condition?NA Item#Piping Containment Sump T5 ETH 91 ●45 Is the sump free of fuel, water or debris Y ●46 Is the sump free of cracks, holes, buldges, or other defects?Y ®47 Are penetration fittings and entry boots intact, secure and free of damage?Y ●48 If the system contains secondarily contained piping with release detection consisting of sump sensors installed in the sump, is the interstice open to the sump? Y ●49 Is the sump sensor properly mounted at the bottom of the sump?Y ●50 Are juction boxes sealed and free of corrosion?Y 1Qty:Dispenser Item# ●51 Is hanging hardware free of visible signs of leakage or damage?Y ●52 Are all components of hanging hardware of the proper type and size?Y ●53 If applicable, is fuel product, safety, octane, diesel sulfer, ethanol, signage present and correct?Y ●54 Are meters, piping, and flexible connectors free of leaks or seeps?Y ●55 Are piping and flexible connectors installed according to manufacturer's specifications? (not kinked or twisted)Y ®56 If no UDC, are any metalpiping components in contact with the soil properly cathodically protected?Y ●57 Are shear valves operating according to the manufacturer's specifications?Y Item#Site Inspection ●58 Is one or more clearly identified emergency shutoff devices located not less than 20ft nor more than 100ft from the dispensing devices, readily accessible to patrons? N ●59 Are the required additional operating and emergency instructions posted and clearly readable in the dispensing area?Y ●60 Is a fire extinguisher with a minimum rating of 40-B, a maintenance inspection not older than 1 year, and located no more than 30ft travel distance from the dispensing devices, readily accessible to patrons? Y ●61 Is a working telephone or other approved, clearly identifed means to notify the fire department provided on the site, and readily accessible to patrons? Y Additional Comments: Notes: Deficiency Information Rec Item Item ID Equip ID Description Remedy Date Image ®58 T5 ETH 91 Fire extinguisher not close to Disp 11/12 Inspector Information By signing below, the operator certifies that the answers above are accurate and based upon performance of associated inspection activities, and that the facility owner has received a copy of this inspection form. Contractor Signature:Date:09/30/2024 Printed Name:Larry Vasquez Certification Number: Automatic Tank Gauge Inspection ATG 1 ATG 1654 Facility Information Name:Fast Stop 1104 Certification/Inspection #:54950 Address:4795 S 3500 W, Roy, UT, 84067 State ID:1200425 Phone Number:Form Completed By:Larry Vasquez Date:09/30/2024 ATG Console Inspection Tank Level Monitor Brand :Veeder Root 1.Status upon Arrival:All Functions Normal 2.Status upon Departure:All Functions Normal 3.Is the display in good condition and functioning?: Yes 4.Is the keypad in good condition?: Yes Tank Level Monitor Model :TLS-450 5.Are all indicator lights functional?: Yes 6.Is printer functional?:Yes 7.Back-up battery tested? (if applicable)?: Yes 8.Back-up battery voltage (if applicable): Tank Information Probe and Programing Inspection: 9.Tank # T1 RUL T2 PUL T5 ETH 91 T3 DSL T4 ETH 88 10.Tank Facility ID T1 RUL T2 PUL T5 ETH 91 T3 DSL T4 EHT 88 11.Tank # per ATG T1 Rul T2 Pul T5 ETH T3 DSL T4 EHT 12.Product:Unleaded Premium Ethanol Free Unleaded Diesel Ethanol Free Unleaded 13.Tank Volume, gallons 14881 4706 1000 4706 4706 14.Tank Dia/depth, inches 90.5 90.5 90.5 90.5 In-Tank Setup Parameters: 15.Thermal coefficient 0.000700 0.000700 0.000700 0.000450 0.000700 16.ATG Programmed Diameter 90.5 90.5 36 90.5 90.5 17.Number of points on profile 18.Full volume on profile 14881 4706 1000 4706 4706 Pass/Fail Criteria: if any of questions 19, 20 ,21 & 22 are No, then the system has failed the test. Comment Operator Certification Contractor Signature:Printed Name:Larry Vasquez 19.After removing the probe from the tank, it has been inspected and any damaged or missing parts replaced? Yes Yes Yes Yes Yes 20.Do floats move freely along the stem without binding?Yes Yes Yes Yes Yes 21.Does product level match console value?Yes Yes Yes Yes Yes 22.Does water level match console value?Yes Yes Yes Yes Yes 23.Water warning (inches)(1")1.5 1.5 1.5 1.5 1.5 24.High water limit (inches)(1.5")2.5 2.5 2.5 2.5 2.5 25.Does console water alarm trigger at programmed level?Yes Yes Yes Yes Yes 26.Programmed Overfill Limit (90%)90 90 90 90 90 27.Does console overfill alarm trigger at programmed level?Yes Yes Yes Yes Yes 28.Programmed High Product Limit (95%)95 95 95 95 95 29.Does console high product alarm trigger at programmed level? Yes Yes Yes Yes Yes 30.Low Product (15% of tank volume or 15" whichever is greater)15 15 15 15 15 31.Tank test program enabled?Yes Yes Yes Yes Yes 32.Tank Test Method?CSLD CSLD CSLD CSLD CSLD 33.Tank Test Rate 0.2 0.2 0.2 0.2 0.2 34.Test duration (hrs)12 12 12 12 12 35.12 months of tank test history present?Yes Yes Yes Yes Yes Lines: 36.Electronic Line Leak Type NA NA NA NA NA 37.Line # and label in ATG (Q1, Unleaded)N/A N/A N/A N/A N/A 38.Line Test Rate N/A N/A N/A N/A N/A 39.12 months of line test history present?NA NA NA NA NA 40.Test Result Pass Pass Pass Pass Pass Leak Detector Facility Information Name:Fast Stop 1104 Certification/Inspection #:54943 Address:4795 S 3500 W, Roy, UT, 84067 State ID:1200425 Phone Number:Form Completed By:Larry Vasquez Date:09/30/2024 Tank Information Tank #:T1 RUL T2 PUL T3 DSL T4 ETH 88 T5 ETH 91 Capacity:14881 4706 4706 4706 1000 Product:Unleaded Premium Diesel Ethanol Free Unleaded Ethanol Free Unleaded Line #:RUL PUL DSL EHT 99 Line Type:Pressure Pressure Pressure Pressure LD Brand:VMI VMI VMI VMI LD Model:LD-2000 LD-2000 LD-2000 LD-2000 Serial #:0 0 0 0 Associated Tank:T1 RUL T2 PUL T3 DSL T4 ETH 88 Resiliency (ml):100 90 100 90 Check Valve Holding PSI:20 19 27 24 Opening Time:2 2 2 2 Result:Pass Pass Pass Pass Test Equip. Mfg.:Vaporless, LDT-890 Vaporless, LDT-890 Vaporless, LDT-890 Vaporless, LDT-890 Notes: Tested per manufacturer specifications. Contractor Signature:Printed Name:Larry Vasquez Line Test Facility Information Name:Fast Stop 1104 Certification/Inspection #:54942 Address:4795 S 3500 W State ID:1200425 Phone Number:Form Completed By:Larry Vasquez Date:09/30/2024 Tank Test Information Tank #:T1 RUL T2 PUL T3 DSL T4 ETH 88 T5 ETH 91 Capacity:14881 4706 4706 4706 1000 Product:Unleaded Premium Diesel Ethanol Free Unleaded Ethanol Free Unleaded Line Test Information Line #:RUL PUL DSL EHT 99 ETH 91 LineType:Pressure Pressure Pressure Pressure Pressure Line Material:DW Flex DW Flex DW Flex DW Flex DW Flex Line ID Size (in):2 2 2 2 2 Line Length (ft):300 300 300 300 100 Pump Type:Red Jacket Red Jacket Red Jacket Red Jacket Red Jacket Associated Tank:T1 RUL T2 PUL T3 DSL T4 ETH 88 T5 ETH 91 Test Equip. Mfg.:Triangle Triangle Triangle Triangle Triangle Test Pressure (PSI):50 50 50 50 50 Initial Cyl. Level:100 100 350 360 360 Final Cyl. Level:70 70 340 360 360 Change in Time (mins):15 15 15 15 15 Change in Vol:-30.0000 -30.0000 -10.0000 0.0000 0.0000 Change in Temp (F):0 0 0 0 0 Coeff. Of Thermal Expansion (g/F):0.00700 0.00070 0.00045 0.00070 0.00070 Line Vol (gal):48.94 48.94 48.94 48.94 16.31 Leak Rate (GPH):-0.0317 -0.0317 -0.0106 0.0000 0.0000 Result:Pass Pass Pass Pass Pass Notes TIGHTNESS TESTING CERTIFICATION CGRS certifies that the systems in the above table have been tested utilizing leak detection methods which meet the prescribed leak rate testing standard of 0.10 gph with a minimum probability of detection of 95% and a 5% probability of a false alarm. CGRS further certifies that the protocol for each test method was strictly adhered to, and that all precision tightness testing performed by CGRS was conducted in accordance with EPA 40 CFR parts 280.43(c) and 280.44(b) and the National Fire Protection Association, Bulletin NFPA 329 criteria. Contractor Printed Name:Larry Vasquez Contractor Signature: Certification Number:TMI-301 UST Operator Inspection -Utah YEAR Qo ~'f ~ Facility Name hid Sh: IID Lj .Inc, Facility ID f 2.oo i./-2S' 0 1\u u+ ?i L/n '1 '1 jPrlmary Class B Operator Address lf 11fJ S . 1 5 00 /J . NAME(S) AND INITIALS OF PERSON(S) CONDUCTIN a'MONTHLY INSPECTIONS: J ~,CA. f3 ,-.,,P ~ }Zo )7i"'-ttz;i r& is-k,,-, /l(r-t Su,• .. ~~ Please respond to ALL of the following questions with a V (Yes), N (No), or NA (Not Applicable) answer . Months of the Current Year J F M A M J J A s 0 N D Monthly Inspection -Release Detection 1 Rel e ase detection equipment is operati ng with no alarms or other unusual '1 ·-1 y ✓ y 'I y V operating conditions. '( ~ 2 Records of release detection (tanks and pipi ng) are reviewed and current. 'I 'i 'J \/ '( ✓ V ,/ y V Monthly Inspection -Spill Prevention Equipment ' . 3 Equ i pment is undamaged, intact and free from defects. " ~ " " y v V 'I y 4 Equipment is free from debris, water, or product. \/ "' \J " .-t ../ V I/ V y V 5 Fill Pipe i s unobstructed. '( 'i y v 'v ' V 'l " V 6 Fill cap is un-broken and is securely on the fill pipe. " 'I 'I 'i y V I/ I/ V 7 Double walled spill prevention equipment -Interstitial area is free from leaks. "i '{ "{ 'I y ✓ '"~ ,.,,Jn y Initials of person performing Inspection. et\ ~ ti-I i ,t ~ ~ Ah 1/l lt U/ I&-.,-,, '" Annual Inspection -Containment Sumps Date of annual lnspec11on 8 Secondary Containment Sumps Visual Inspection of sump indicates no damage and it is free from debris, wat er and fuel. 9 (STP, Dispenser and Transition) The penetrat ion fittings for conduits and piping entering the STP Sumps are intact. y ~~ 9 Double Walled Sumps Interstitial area is free from leaks. y ~, Hand-held release detection Hand-held release detection equipment (bailer, gauge stick, etc.) is serviceable and y -10 equipment operable. I certify under penalty of law that I am the Class B Operator referenced above and that I am familiar with information on this form and that it is true, accurate and was completed in accordance with R311-203-7 . / ., Si gnature of the Primary Class B Operator (Sign this document after the last inspection of the Current Year) Da~lf B Operator# Comments/Follow u!: Turn ove r for r ecord of Jnterslllia l Monitoring visu al insp ections a nd Impres sed Curre nt r ec tifier chec k s. 1 - y pei.org 57 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-7 AUTOMATIC TANK GAUGE OPERATION INSPECTION Facility Name:Owner: Address:Address: City, State, Zip Code:City, State, Zip Code: Facility I.D. #:Phone #: Testing Company:Phone #:Date: This procedure is to determine whether the automatic tank guage (ATG) is operating properly. See PEI/RP1200 Section 8.2 for the inspection procedure. This procedure is applicable to tank level monitor stems that touch the bottom of the tank when in place. Tank Number Product Stored ATG Brand and Model 1. Tank Volume, gallons 2. Tank Diameter, inches 3. After removing the ATG from the tank, it has been inspected and any damaged or missing parts replaced? Yes No Yes No Yes No Yes No 4. Float moves freely on the stem without binding? Yes No Yes No Yes No Yes No 5. Fuel float level agrees with the value pro- grammed into the console? Yes No Yes No Yes No Yes No 6. Water float level agrees with the value pro- grammed into the console? Yes No Yes No Yes No Yes No 7.Inch level from bottom of stem when 90% alarm is triggered. 8. Inch level at which the overfill alarm activates corresponds with value programmed in the gauge? Yes No Yes No Yes No Yes No 9. Inch level from the bottom when the water float first triggers an alarm. 10. Inch level at which the water float alarm acti- vates corresponds with value programmed in the gauge? Yes No Yes No Yes No Yes No If any answers in Lines 3, 4, 5, or 6 are “No,” the system has failed the test. Test Results Pass Fail Pass Fail Pass Fail Pass Fail Comments: Tester’s Name (print) ___________________________________ Tester’s Signature _________________________________ Fast Stop 1104 4795 S 3500 W, Roy, UT 84067 1200425 CGRS 9/5/24 T1 T 2 T 3 T4 RUl PUL DSL ETH88 TLS 450 TLS 450 TLS 450 TLS 450 14881 4706 4706 4706 90.5 90.5 90.5 90.5 81.5 81.5 81.5 81.5 2.5 2.5 2.5 2.5 Ray Simms pei.org 57 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-7 AUTOMATIC TANK GAUGE OPERATION INSPECTION Facility Name:Owner: Address:Address: City, State, Zip Code:City, State, Zip Code: Facility I.D. #:Phone #: Testing Company:Phone #:Date: This procedure is to determine whether the automatic tank guage (ATG) is operating properly. See PEI/RP1200 Section 8.2 for the inspection procedure. This procedure is applicable to tank level monitor stems that touch the bottom of the tank when in place. Tank Number Product Stored ATG Brand and Model 1. Tank Volume, gallons 2. Tank Diameter, inches 3. After removing the ATG from the tank, it has been inspected and any damaged or missing parts replaced? Yes No Yes No Yes No Yes No 4. Float moves freely on the stem without binding? Yes No Yes No Yes No Yes No 5. Fuel float level agrees with the value pro- grammed into the console? Yes No Yes No Yes No Yes No 6. Water float level agrees with the value pro- grammed into the console? Yes No Yes No Yes No Yes No 7.Inch level from bottom of stem when 90% alarm is triggered. 8. Inch level at which the overfill alarm activates corresponds with value programmed in the gauge? Yes No Yes No Yes No Yes No 9. Inch level from the bottom when the water float first triggers an alarm. 10. Inch level at which the water float alarm acti- vates corresponds with value programmed in the gauge? Yes No Yes No Yes No Yes No If any answers in Lines 3, 4, 5, or 6 are “No,” the system has failed the test. Test Results Pass Fail Pass Fail Pass Fail Pass Fail Comments: Tester’s Name (print) ___________________________________ Tester’s Signature _________________________________ Fast Stop 1104 4795 S 3500 W Roy, UT 84067 1200425 CGRS 9/5/24 T5 ETH 91 TLS 450 TLS 450 TLS 450 TLS 450 1000 36 32.5 2.5 Ray Simms PE I / R P 1 2 0 0 -1 9 pe i . o r g 58 AP P E N D I X C - 8 LIQUID SENSOR FUNCTIONALITY TESTING Facility Name:Owner: Address:Address: City, State, Zip Code:City, State, Zip Code: Facility I.D. #:Phone #: Testing Company:Phone #:Date: This procedure is to determine whether liquid sensors located in the interstitial space of UST systems are able to detect the presence of water and fuel. See PEI/RP1200 Section 8.3 for the test procedure. Sensor Location Product Stored Type of Sensor Discriminating Non-discrimi- nating Discriminating Non-discrimi- nating Discriminating Non-discrimi- nating Discriminating Non-discrimi- nating Discriminating Non-discrimi- nating Discriminating Non-discrimi- nating Discriminating Non-discrimi- nating Test Liquid Water Product Water Product Water Product Water Product Water Product Water Product Water Product Is the ATG console clear of any active or recurring warnings or alarms regarding the leak sensor? If the sensor is in alarm and functioning, indicate why. Yes No Yes No Yes No Yes No Yes No Yes No Yes No Is the sensor alarm circuit operational? Yes No Yes No Yes No Yes No Yes No Yes No Yes No Has sensor been inspected and in good operating condition? Yes No Yes No Yes No Yes No Yes No Yes No Yes No When placed in the test liquid, does the sensor trigger an alarm? Yes No Yes No Yes No Yes No Yes No Yes No Yes No When an alarm is triggered, is the sensor properly identified on the ATG console? Yes No Yes No Yes No Yes No Yes No Yes No Yes No Any “No” answers indicates the sensor fails the test. Test Results Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Comments: Tester’s Name (print) ___________________________________ Tester’s Signature _______________________________________________ Fast Stop 1104 4795 S 3500 W, Roy, UT 84067 1200425 CGRS DISP 1/2 Disp 2/3 Dsip 4/5 DISp 6/7 DISP 8/9 DISP 10/11 Disp 12/3 PUL RUL PUL RUL PUL RUL PUL RUL PUL RUL DSL, PUL RUL DSL,Pul RUL PE I / R P 1 2 0 0 -1 9 pe i . o r g 58 AP P E N D I X C - 8 LIQUID SENSOR FUNCTIONALITY TESTING Facility Name:Owner: Address:Address: City, State, Zip Code:City, State, Zip Code: Facility I.D. #:Phone #: Testing Company:Phone #:Date: This procedure is to determine whether liquid sensors located in the interstitial space of UST systems are able to detect the presence of water and fuel. See PEI/RP1200 Section 8.3 for the test procedure. Sensor Location Product Stored Type of Sensor Discriminating Non-discrimi- nating Discriminating Non-discrimi- nating Discriminating Non-discrimi- nating Discriminating Non-discrimi- nating Discriminating Non-discrimi- nating Discriminating Non-discrimi- nating Discriminating Non-discrimi- nating Test Liquid Water Product Water Product Water Product Water Product Water Product Water Product Water Product Is the ATG console clear of any active or recurring warnings or alarms regarding the leak sensor? If the sensor is in alarm and functioning, indicate why. Yes No Yes No Yes No Yes No Yes No Yes No Yes No Is the sensor alarm circuit operational? Yes No Yes No Yes No Yes No Yes No Yes No Yes No Has sensor been inspected and in good operating condition? Yes No Yes No Yes No Yes No Yes No Yes No Yes No When placed in the test liquid, does the sensor trigger an alarm? Yes No Yes No Yes No Yes No Yes No Yes No Yes No When an alarm is triggered, is the sensor properly identified on the ATG console? Yes No Yes No Yes No Yes No Yes No Yes No Yes No Any “No” answers indicates the sensor fails the test. Test Results Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Comments: Tester’s Name (print) ___________________________________ Tester’s Signature _______________________________________________ Fast Stop 1104 4795 S 3500 W, Roy, UT 84067 1200425 CGRS 10 -1-24 T1 RUL T2 PUL T3 DSL T4 88 ETH 91 Piping RUL PUL DSL 88Eth 91 ETH Larry Vasquez pei.org 59 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-9 MECHANICAL AND ELECTRONIC LINE LEAK DETECTORS PERFORMANCE TESTS Facility Name:Owner: Address:Address: City, State, Zip Code:City, State, Zip Code: Facility I.D. #:Phone #: Testing Company:Phone #:Date: This data sheet can be used to test mechanical line leak detectors (MLLD) and electronic line leak detectors (ELLD) with submersible turbine pump (STP) systems. See PEI/RP1200 Sections 9.1 and 9.2 for test procedures. Line Number Product Stored Leak Detector Manufacturer Leak Detector Model Type of Leak Detector MLLD ELLD MLLD ELLD MLLD ELLD MLLD ELLD MLLD ELLD MLLD ELLD MLLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) STP Full Operating Pressure Check Valve Holding Pressure Line Resiliency (ml) (line bleed back vol- ume as measured from check valve hold- ing pressure to 0 psig) Step Through Time in Seconds (time the MLLD hesitates at metering pressure before going to full operating pressure as measured from 0 psig with no leak induced on the line) Metering Pressure (STP pressure when simulated leak rate 3 gph at 10 psig) Opening Time in Seconds (the time the MLLD opens to allow full pressure after simulated leak is stopped) Does the STP pressure remain at or below the metering pressure for at least 60 seconds when the simulated leak is induced? Yes No Yes No Yes No Yes No Yes No Yes No Does the leak detector reset (trip) when the line pressure is bled off to zero psig? Yes No Yes No Yes No Yes No Yes No Yes No Does the STP properly cycle on/off under normal fuel system operation conditions? Yes No Yes No Yes No Yes No Yes No Yes No A “No” answer to either of the above questions indicates the MLLD fails the test. ELLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) STP Full Operating Pressure How many test cycles are observed before alarm/shutdown occurs? Does the simulated leak cause an alarm? Yes No Yes No Yes No Yes No Yes No Yes No A “No” answer to the above question indi- cates the ELLD fails the test. Does the simulated leak cause an STP shutdown? Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA Test Results Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Comments: Tester’s Name (print) ___________________________________ Tester’s Signature __________________________________ Fast Stop 1104 4795 S 3500 W, Roy, UT 84067 1200425 CGRS 9-30-24 L 1 L 2 L 3 L 4 RUL PUL DSL 88 ETH VMI VMI VMI VMI LD-2000 LD-2000 LD-2000 LD-2000 2 5 2 4 2 5 2 7 20 19 27 24 100 90 100 90 2 2 2 2 10 13 15 13 2 2 2 2 UTAH CONTAINMENT SUMP TEST Hydrostatic Test Form Tester’s Signature______________________________ Facility Name Facility ID Address Tester’s Name Test Date Phone Type of containment Sump  Dispenser  Transition  Tank Top  Dispenser  Transition  Tank Top  Dispenser  Transition  Tank Top  Dispenser  Transition  Tank Top  Dispenser  Transition  Tank Top  Dispenser  Transition  Tank Top Sump ID (e.g. dispenser #, tank location, product, etc.) Sump Material Construction  Single walled  Double walled  Single walled  Double walled  Single walled  Double walled  Single walled  Double walled  Single walled  Double walled  Single walled  Double walled Liquid and debris removed  Yes  No  Yes  No  Yes  No  Yes  No  Yes  No  Yes  No Visual Inspection No cracks, holes or separations.  Pass  Fail  Pass  Fail  Pass  Fail  Pass  Fail  Pass  Fail  Pass  Fail Containment Sump Depth Height from bottom to top of highest penetration Start Level Start Time Ending Level End Time Test Period (Minimum of 1 hour) Water Level Change Test Results  Pass  Fail  Pass  Fail  Pass  Fail  Pass  Fail  Pass  Fail  Pass  Fail Photos indicating water levels attached?       Pass/fail criteria: Must pass visual inspection, test duration at least one hour, must include photos with this form, water level drop of less than 1/8 inch. Ref: PEI/RP 1200 6.5 Test Method How was the liquid disposed? Comments Aug 2016 I certify under penalty of law that the above information is true, accurate and complete. Fast Stop 1104 1200425 Roy, UT 84067 9-30-24 T1 RUl T2 PUL T3 DSL T4 88ETH T5 91 ETH FRP FRP FRP FRP FRP 40"40"40"40"28" 50"50"50"50"32" 22"22"21"22"9" 4:32 7:29 6:19 3:32 12:51 22"22"21"22"9" 5:32 8:29 7:19 4:32 1:51 1 1 1 1 1 0 0 0 0 0 4795 S 3500 W, UTAH CONTAINMENT SUMP TEST Hydrostatic Test Form Tester’s Signature______________________________ Facility Name Facility ID Address Tester’s Name Test Date Phone Type of containment Sump  Dispenser  Transition  Tank Top  Dispenser  Transition  Tank Top  Dispenser  Transition  Tank Top  Dispenser  Transition  Tank Top  Dispenser  Transition  Tank Top  Dispenser  Transition  Tank Top Sump ID (e.g. dispenser #, tank location, product, etc.) Sump Material Construction  Single walled  Double walled  Single walled  Double walled  Single walled  Double walled  Single walled  Double walled  Single walled  Double walled  Single walled  Double walled Liquid and debris removed  Yes  No  Yes  No  Yes  No  Yes  No  Yes  No  Yes  No Visual Inspection No cracks, holes or separations.  Pass  Fail  Pass  Fail  Pass  Fail  Pass  Fail  Pass  Fail  Pass  Fail Containment Sump Depth Height from bottom to top of highest penetration Start Level Start Time Ending Level End Time Test Period (Minimum of 1 hour) Water Level Change Test Results  Pass  Fail  Pass  Fail  Pass  Fail  Pass  Fail  Pass  Fail  Pass  Fail Photos indicating water levels attached?       Pass/fail criteria: Must pass visual inspection, test duration at least one hour, must include photos with this form, water level drop of less than 1/8 inch. Ref: PEI/RP 1200 6.5 Test Method How was the liquid disposed? Comments Aug 2016 I certify under penalty of law that the above information is true, accurate and complete. Fast Stop 1104 1200425 Roy, UT 84067 9-30-24 1/2 3/4 5/6 7/8 9/10 11/12 Poly Poly Poly Poly Poly poly 28"28"28"28"28"28" 31"31"31"31"31"31" 8"8"10"8"9"9" 9:25 9:41 9:45 9:55 12:51 12:51 8"8"10"8"9"9" 9:25 9:41 9:45 9:55 1:51 1:51 1 1 1 1 1 1 0 0 0 0 0 0 4795 S 3500 W,