Loading...
HomeMy WebLinkAboutDDW-2024-013211SALT LAKE AREA OFFICE  859 W South Jordan Pkwy – Ste 200  South Jordan, Utah 84095    Phone: (801) 566‐5599  www.hansenallenluce.com      ENGINEERING EXCELLENCE SINCE 1974 Mr. David Kruse October 28, 2024 Source Monitoring Rules Manager Utah Division of Drinking Water P.O. Box 144830 Salt Lake City, Utah 84114-4830 RE: Summit County Service Area No. 3 (System #22105) Quarterly Arsenic Report for the 3rd Quarter 2024, Greenfield Well (WS002) Dear Mr. Kruse, Summit County Service Area #3 (Service Area) provides drinking water to customers in the area of Silver Creek Estates. The Service Area owns and operates two wells. The first of the Service Area’s wells is the District Well (WS001). The District Well was drilled and equipped in 1963 and produces about 180 gpm. Water from the District Well has an arsenic level of about 4 ppb. In 2003, the Service Area drilled the Greenfield Well (WS002), which produces up to about 200 gpm. Water from the Greenfield Well has an arsenic level of about 22 to 23 ppb. An operating permit for the Greenfield Well was approved by the Utah Division of Drinking Water (DDW) on February 23, 2012, and revised via correspondence dated October 23, 2012. Because the arsenic level in water from the Greenfield Well is above 10 ppb, the operating permit outlined specific arsenic testing and reporting requirements associated with using the well. Additionally, quarterly arsenic sampling is required at the Greenfield Well and at Silver Creek Estates Lot 278 (SS278). The sampling is typically performed monthly, and the results are averaged for each quarter. A running annual average is computed using the averaged results. The running annual average is to be maintained below the arsenic MCL of 10.0 ppb. The Greenfield Well’s Operating Permit specifies that monitoring results are to be reported at the conclusion of each quarter. This letter contains the report for the 3rd quarter of 2024. ARSENIC SAMPLING RESULTS Water samples were collected by Service Area personnel and submitted to Chemtech-Ford Laboratories for analytical testing. The analytical results of the last four quarters are presented in Table 1, Table 2, and Table 3 for SS278, WS001 and WS002, respectively. 10/28/2024 Mr. David Kruse October 28, 2024 Page 2 of 6 TABLE 1 SS278 ARSENIC SAMPLING RESULTS AND SUMMARY Quarter Month Arsenic Level (ppb) Quarterly Average (ppb) 4th Quarter 2023 October - 9.7 November 13.5 December 5.9 1st Quarter 2024 January - 8.7 February 8.7 March - 2nd Quarter 2024 April 4.2 4.3 May 3.9 June 4.8 3rd Quarter 2024 July 4.3 6.4 August 5.6 September 9.3 Annual Average 7.3 From the data in Table 1, it may be observed that the annual average arsenic level is 7.3 ppb at Lot 278, which is below the MCL of 10 ppb. Mr. David Kruse October 28, 2024 Page 3 of 6 TABLE 2 DISTRICT WELL (WS001) ARSENIC SAMPLING RESULTS AND SUMMARY Quarter Month Arsenic Level (ppb) Quarterly Average (ppb) 4th Quarter 2023 October - 4.3 November 4.6 December 4.0 1st Quarter 2024 January - 4.0 February 4.0 March - 2nd Quarter 2024 April 4.0 4.2 May 3.7 June 4.8 3rd Quarter 2024 July 4.0 4.1 August 4.2 September 4.0 Annual Average 4.1 Mr. David Kruse October 28, 2024 Page 4 of 6 TABLE 3 GREENFIELD WELL (WS002) SAMPLING RESULTS AND SUMMARY Quarter Month Arsenic Level (ppb) Quarterly Average (ppb) 4th Quarter 2023 October - 22.2 November 21.9 December 22.6 1st Quarter 2024 January - 23.0 February 23.0 March - 2nd Quarter 2024 April 22.1 22.4 May 21.6 June 23.5 3rd Quarter 2024 July 21.9 21.4 August 21.5 September 20.9 Annual Average 22.3 Mr. David Kruse October 28, 2024 Page 5 of 6 WATER USE DATA The arsenic compliance plan described in the operating permit letter requires reporting of Greenfield Well and District Well water use data. The reported water use is based on data provided by the Service Area No. 3 SCADA system. Water use data for the Service Area’s two water sources are summarized in Table 4. Following Table 4, Table 5 presents weekly production data for the 3rd quarter. TABLE 4 WATER USE DATA Quarter Month Greenfield Well (gallons) District Well (gallons) Quarterly Total (gallons) 4th Quarter 2023 October 101,847 1,741,686 4,152,242 November 902,259 257,748 December 0 1,148,702 1st Quarter 2024 January 0 1,770,709 6,978,412 February 0 2,426,668 March 0 2,781,035 2nd Quarter 2024 April 0 1,524,113 7,136,056 May 0 1,870,030 June 0 3,741,913 3rd Quarter 2024 July 0 4,209,906 9,068,465 August 0 2,769,109 September 0 2,089,450 Total 1,004,106 26,331,069 27,335,175 Mr. David Kruse October 28, 2024 Page 6 of 6 TABLE 5 3RD QUARTER 2024 WEEKLY WATER USE DATA Date Greenfield Well (gallons) District Well (gallons) Jul 1 – 6 0 800,853 Jul 7 – 13 0 1,045,132 Jul 14 – 20 0 962,945 Jul 21 – 27 0 914,191 Jul 28 – Aug 3 0 813,587 Aug 4 – 10 0 821,105 Aug 11 – 17 0 581,363 Aug 18 – 24 0 570,090 Aug 25 – 31 0 469,749 Sep 1 – 7 0 483,326 Sep 8 – 14 0 439,269 Sep 15 – 21 0 431,299 Sep 22 – 28 0 589,146 Sep 29 – 30 0 146,410 Total 0 9,068,465 CONCLUSION The available data show that the water delivered to water system customers complies with the drinking water standards for arsenic. The annual running average at SS278 (7765 N. Silver Creek Road) is 7.3 ppb. Please contact me if you have any questions or concerns. Sincerely, HANSEN, ALLEN & LUCE, INC. ___________________________ Jason C. Biesinger, P.E. Project Engineer