DAQC-1106-24
Site ID 10096 (B5)
MEMORANDUM
TO: FILE – SUNNYSIDE COGENERATION ASSOCIATES
THROUGH: Harold Burge, Major Source Compliance Section Manager
FROM: Rob Leishman, Environmental Scientist
DATE: October 29, 2024
SUBJECT: Sunnyside Cogeneration Associates (Sunnyside), Major, NSPS, Title V, Carbon
County – FRS # UT00000049000700030
INSPECTION TYPE: State Electronic Data Report (SEDR) Review
REVIEW DATE: October 29, 2024
SOURCE LOCATION: East Carbon/Emery County
SOURCE CONTACT: Rusty Netz, (435) 888-4476 x107
APPLICABLE
REGULATIONS: Title V Operating Permit
Permit Number: 700030005
Date of Permit: March 8, 2023
Date of Last Revision: March 8, 2023
SOURCE INSPECTION
EVALUATION: With the exception of sources that only monitor for opacity, quarterly
report memoranda will only address the findings of the quarterly report.
Approval Order and Title V permit conditions addressing continuous
emission monitoring requirements will be addressed in Sunnyside’s
relative accuracy performance specification test review memorandum.
1 8 2
2
SEDR Review:
Third Quarter 2024
% Monitor Availability (MA) Performance Test Dates
(N/A to Opacity)
Summary of Excess Emissions During
Point Source Operation
Point
Source
Op.
hrs. Channel MA CGA Lin RATA Point
Source Channel Hrs. Limitation
Unit 1 2108 SO2 99% 09/04/24 05/23/24 Unit 1 SO2 0.00
0.42
LB/MMBTU
- 30 DRA
Unit 1 2108 NOx 98% 09/04/24 05/23/24 Unit 1 SO2 0.00
1.2
LB/MMBTU
- 30 DRA
Unit 1 2108 O2 99% 09/04/24 05/23/24 Unit 1 SO2 0.00 462 LB/HR -
3 HR BLOCK
Unit 1 2108 Opacity 99% Unit 1 SO2 0.00
462 LB/HR -
24 HR
BLOCK
Unit 1 SO2 0.00
(>70) So2
Removal % -
30 DRA
Unit 1 NOx 0.00
0.25
LB/MMBTU
- 30 DRA
Unit 1 NOx 0.00
0.6
LB/MMBTU
- 30 DRA
Unit 1 Opacity 0.00 10 % - 6 min.
Summary of SO2 Emission Reduction
Percent Removal Required
% Reduction
Point
Source Channel Min Max Days in violation Status
Unit 1 SO2 91% 93% 70% 0 In compliance
Excess Emission Report - Hourly Summary
Point
Source Channel
Startup
&
Shutdown
Control
Equipment
Problems
Process
Problems
Other
Known
Causes
Unknown
Causes
Emission
Limit
Unit 1 SO2 0 0 0 0 0 0.42 LB/MMBTU - 30 DRA
Unit 1 SO2 0 0 0 0 0 1.2 LB/MMBTU - 30 DRA
Unit 1 SO2 0 0 0 0 0 462 LB/HR - 3 HR BLOCK
Unit 1 SO2 0 0 0 0 0 462 LB/HR - 24 HR BLOCK
Unit 1 SO2 0 0 0 0 0 (>70) So2 Removal % - 30
DRA
Unit 1 NOx 0 0 0 0 0 0.25 LB/MMBTU - 30 DRA
Unit 1 NOx 0 0 0 0 0 0.6 LB/MMBTU - 30 DRA
Unit 1 Opacity 0 0 0 0 0 10 % - 6 min.
3
CMS Performance Summary - Hourly Summary
Point
Source Channel Monitor
Malfunction
Non-monitor
Malfunction
QA
Calibrations
Other
Known
Causes
Unknown
Causes
Unit 1 SO2 11 0 11 4 0
Unit 1 NOx 11 0 35 4 0
Unit 1 O2 11 0 11 4 0
Unit 1 Opacity 26 0 3 0 0
Type Code 280 (COMS Attenuator Filters) Procedure 3
Point Source &
Location
Attenuator
I.D.
Attenuator
Certification
Date
Certified
Attenuator
Opacity
OPLR,
SECR,
or
PLCF,
Corrected
Opacity
Value
Range
Low,
Mid, &
High
Certification
1-year or 5-
year
Unit 1 - Cal Check VT49 3/25/24 8.60 1.00 0 low 1 Year
Unit 1 - Cal Check UU35 3/25/24 15.40 1.00 0.1 mid 1 Year
Unit 1 - Cal Check UU36 3/25/24 25.20 1.00 0.1 high 1 Year
Type Code 281 (Procedure 3 - COMS Filter Audit Calibration Error)
Point
Source Location Audit Date
Opacity Monitor Response
(Average of 5) Mean Difference Calibration
Error (≤ 3%) Low Mid High
Unit 1 Stack 9/5/24 9 0.100 0.139
Unit 1 Stack 9/5/24 15 -0.740 -0.641
Unit 1 Stack 9/5/24 25 0.040 0.088
Type Code 282 (Annual Zero Alignment Audit) Procedure 3
Point
Source Location Audit
Date
Alternative
Zero Alignment
(Yes or No)
COM Clear
Condition
Zero
Response
(CCZR)
COM
Simulated
Zero
Response
(CSZR)
Zero
Alignment
Error
Difference
(CCZR)-
(CSZR)
Adjustment to
COM
Simulated Zero
Response
(CSZR)
(Yes or No)
Unit 1 Stack 6/12/24 No 0.00 -0.1 0 Yes
Summary of SO2 Emission Reduction
Percent Removal Required Percent
Reduction
Point
Source Channel Min Max Days in violation
Unit 1 SO2 91% 93% 70% 0
Pollutant Concentration
Exceeded Span of CEM
Monitor Outage During
Point Source Operation
Alternate
Sampling CEM Modifications
0 Hours 131 Hours 0 Hours 0 Events
4
SOURCE INSPECTION
SUMMARY EVALUATION: Sunnyside maintains its CEMS as required in R307-170 and 40 CFR
60.13.
CURRENT
RECOMMENDATIONS: All deviations appear to be a result of breakdown or process related
problems that do not warrant issuing a violation. Periods of excess
emissions that were recorded by the CMS in service on each point source
during this reporting period are summarized in the SEDR and described
in Pivot Table 400 “Excess Emissions Review.”
Sunnyside was in compliance during this reporting period. No further
enforcement actions should be taken.
Sunnyside’s NSPS monitoring system meets the performance standards
of 40 CFR 60, Appendix B Performance Specifications.
HIGH PRIORITY
VIOLATOR (HPV): No.
RECOMMENDATION
FOR NEXT INSPECTION: Check DAS for daily zero and span drift.
Check the QC program to ensure that monitor drift is being tracked and
that the source can identify excessive drift.
ATTACHMENT: Excel spreadsheet review.
Sunnyside Cogeneration Associates
PO. llox I5t) . Sunnyside, Lltah 84.53t) . (43.5) uSt3_447(r . Fax (43.5) ulJu 2.53,3
October 24,2024
Rob Leishman
Division of Air Quality
195 North 1950 West
Salt Lake City, Utah 94116
Re: signed statement for cEM euarterly Report (3rd euarte r, zoz4)
Dear Mr. Leishman:
I acknowledge under penalties of law that all irrformation containecl in thequarterly CEM report is truthful and accurate, and is a complete record of all monitoringrelated events which occurred during the reporting period. This is in accordance withutah Air Rules, R307- 1 70-9(9)(a) un,l n:07-+ 1 5--5d,,,signed statement,,.
If you have any questions or if further clarification is needed, please contactMichael Mosley or Rusty Netz at (435) gg3-4476.
'l'[rank You"
/ ^./ ,/--o*d.r/. ( gDal-CUU
Logan Egbert
Responsible Official
Sunnyside Cogeneration Associates
Rusty Netz
Plant Irile
Sunnyside Cogeneration Associates
P.O. Box l-59 . Srrnnysidc, Utah ti4-539 . (43.5) 88tj_4476 . liiax t+:sl,{ilfil
I irril I
SIGNED STA'I'EMENTS1' For any periods for which opacity, sulfur dioxide, or nitrous oxides emrssion data is notavailable' changes , u/ere not , made in operation of the emission control system.were/were not
The required continuous monitoring system calibration , span and drift checks and otherauditshavebeen performed as specifred.
have/have not
xplain any changes:
3. The data used to show compliance
ethods and procedures of part Db and
The minimum data requirements
unavoidable.
obtained in accordance with approved
representative of plant performance.
Date.101241202,1
was/was not
WAS
I5
%is/not
have/have nothave been met for errors that were
-
compliance with the standard has been achieved during the reporting period
has/has not
Signed /_-oea), azdatf
Regponsible ()fficial
Sunnyside EER 3Q2024
Point Source Information Late Expired Cal. Gas Valid Cal. Gas Days Yes No
1 Type Code 100
(Company Information)Type Code Company Manager Company Name AIRS # Phone Number
Environmental
Contact
1 100
Logan
Egbert/Michael Mosley 00700030 (435)888-4476 Rusty Netz
1 100 0 0 0 0
1 Type Code 110
(Point Source Identification)Type Code Point Source
Quarter
1 - 4 Year
Point Source
Operating Hrs. in
Quarter1 110 3 2024 2108
1 110 0 0 0
1 Type Code 200
(Monitor Identification)Type Code Point Source Channel Manufacturer Model No. Monitor SN Low Span High Span Installation Date
Monitor
Location1 200 NOx EcoChem MC3 425 0 250 3/27/2019 Stack
1 200 O2 EcoChem MC3 425 0 25 3/27/2019 Stack
1 200 Opacity Durag D-R 290 417243 0 100 4/18/2005 Stack
1 200 SO2 EcoChem MC3 425 0 300 3/27/2019 Stack
1 200 0 0 0 0 0 0 1/0/1900 0
1 Type Code310
(Excess Emissions)SUMMARY REPORT Type Code Channel
Total Hours of Excess Emissions
Excess Emissions -
% of Total Operating Hours
RC 701 Hours -
start up/Shutdown
RC 702 Hours-
Control Equipment Problems
RC 703 Hours -Process Problems
RC 704, 706, 707
Hours -Other Known Causes
RC 705 Hours -
Unknown Causes
Emission Limitation
Emission
Limitation Units
Emission
Limitation
Averaging Period
1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 0.42 LB/MMBTU 30 DRA
1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 1.2 LB/MMBTU 30 DRA
1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 462 LB/HR 3 HR BLOCK
1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 462 LB/HR 24 HR BLOCK
1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 (>70) So2 Removal% 30 DRA
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 0.25 LB/MMBTU 30 DRA
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 0.6 LB/MMBTU 30 DRA
1 TRUE 310 Opacity 0 0.00% 0 0 0 0 0 10 % 6 min.
1 310 0 0 0 0 0 0 0 0 0
1 Type Code 300 (CMS
Performance Summary) Type Code Channel
Point Source Operating
Hours
Downtime - % of
Total Operating
Hours
Total CMS
Downtime
RC 721 Hours -
Monitor
Malfunction
RC 722 Hours -
Non-monitor
Malfunction
RC 723 Hours -
QA Calibrations
RC 724 Hours -
Other Known
Causes
RC 725 Hours -
Unknown
Causes1 TRUE 300 SO2 2108 1.23% 26 11 0 11 4 0
1 TRUE 300 NOx 2108 2.37% 50 11 0 35 4 0
1 TRUE 300 O2 2108 1.23% 26 11 0 11 4 0
1 TRUE 300 Opacity 2108 1.38% 29.1 25.8 0 3.3 0 0
1 300 0 0 0 0 0 0
1
Type Code 250
(Performance Specification
RATA Results)
Type Code Channel
Date of Most Current
RATA
Date of Preceding
RATA
Months Between
RATA's
Units of
Measurement CEM Value Reference Method
Value
Relative
accuracy Pass/ Fail
1 373 Days 250 SO2 05/23/24 05/16/23 12 lb/mmBtu 0.19 0.19 3.08% Pass
1 373 Days 250 SO2 05/23/24 05/16/23 12 lbs/hr 119.9 140.3 16.65% Pass
1 373 Days 250 NOx 05/23/24 05/16/23 12 lb/mmBtu 0.271 0.254 7.33% Pass
1 373 Days 250 Flow 05/23/24 05/16/23 12 SCFM 174595 172609 1.36% Pass
1 373 Days 250 O2 05/23/24 05/16/23 12 Percent 5.9 5.7 0.21% Pass
1 0 Days 250 0 01/00/00 01/00/00 0 0 0 0 0.00% 0
1 Type Code 260
(CGA Results)Type Code Channel Date Audit Point No. Cylinder ID
Cylinder
Expiration Date
Type of
Certification
Units of
Measurement CEM Value Cylinder
Value
Precision
%Pass/ Fail Range - High or
Low1 260 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0
1 Type Code 270(Linearity Test Results)Type Code Channel Date Audit Point No. Cylinder ID
Cylinder
Expiration Date
Type of
Certification
Units of
Measurement CEM Value Cylinder
Value
Precision
%Pass/ Fail Range - High or
Low
1 Valid Cal. Gas 270 NOx 09/04/24 1 CC210097 06/25/32 P1-G1 ppm 61.86 62.9 -1.65% pass Low
1 Valid Cal. Gas 270 NOx 09/04/24 2 ALM012644 02/01/29 P1-G1 ppm 137.53 137.8 -0.20% pass Mid
1 Valid Cal. Gas 270 NOx 09/04/24 3 CC265425 01/11/32 P1-G2 ppm 231.96 234.1 -0.91% pass High
1 Valid Cal. Gas 270 O2 09/04/24 1 SG9166090 12/26/26 P1-G3 ppm 6.2 6.3 -2% pass Low
1 Valid Cal. Gas 270 O2 09/04/24 2 CC156245 04/23/32 P1-G4 ppm 14 14.04 0% pass Mid
1 Valid Cal. Gas 270 O2 09/04/24 3 CC347470 02/03/29 P1-G5 ppm 22.8 22.6 1% pass High
1 Valid Cal. Gas 270 SO2 09/04/24 1 CC210097 06/25/32 P1-G1 ppm 74.9 75.3 -0.53% pass Low
1 Valid Cal. Gas 270 SO2 09/04/24 2 ALM012644 02/01/29 P1-G1 ppm 164.43 167.2 -1.66% pass Mid
1 Valid Cal. Gas 270 SO2 09/04/24 3 CC265425 01/11/32 P1-G2 ppm 277.56 278.2 -0.23% pass High
1 270 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0
1 Type Code 210(Pollutant Concentration
Exceeded Span of CEM)
Type Code Channel Start Date Start Time End Date End Time Hours
1 0 0 0 1/0/00 0:00 1/0/00 0:00
1
1 None Reported
1 0 TC 220 Hours 131.10 TC 220 Hours 0.00 TC 230 Hours 0.00 Events 0.00 Hours 0.00 Events 0.00 0.00
1 131.10 TC 300 Hours 0.00 TRUE
0
Unit 1
Unit 1
Unit 1
Unit 1
0
Unit 1
Unit 1
Unit 1
Unit 1
Unit 1
Unit 1
Unit 1
Unit 1
Unit 1
0
Unit 1
Type Code 210
(Pollutant Concentration
Exceeded Span of CEM)
Type Code 220
(Monitor Outage
During Point Source Operation)
Type Code 230
(Manual Sample - Alternate
Sampling During MonitorOutage)
Type Code 240
(CEM Modifications)
Type Code 530
(Excess Emissions During
Emergency Conditions)
Sunnyside Cogeneration Associates
0
Type Code 450
(Data Excluded)
Unit 1
Unit 1
Unit 1
Unit 1
0
Unit 1
Unit 1
Unit 1
0
Unit 1
Unit 1
Type Code 550
(Changes in Operation in
Control Equipment When CEM Data Not Available)
Type Code 500
(Boiler Operating Days
w/o 18 Hours of Data)
Unit 1
Unit 1
Unit 1
Unit 1
0
Unit 1
Unit 1
Unit 1
0
Unit 1
0
Point Source
Point Source
Point Source
Point Source
Point Source
Point Source
Yes None Reported None Reported Yes Yes None Reported None Reported
Sunnyside EER 3Q2024
Relative Accuracy Overview
Point Source Channel
Date of Most
Current
RATA
Date of
Preceding
RATA
Months Between
RATA's
Units
Measured CEM Value Reference Method
Value
Relative
Accuracy Pass/ Fail 2024
Unit 1 SO2 05/23/24 05/16/23 12 lb/mmBtu 0.19 0.19 3.08% Pass
Unit 1 SO2 05/23/24 05/16/23 12 lbs/hr 119.9 140.30 16.65% Pass
Unit 1 NOx 05/23/24 05/16/23 12 lb/mmBtu 0.271 0.25 7.33% Pass
Unit 1 Flow 05/23/24 05/16/23 12 SCFM 174595 172609.00 1.36% Pass
Unit 1 O2 05/23/24 05/16/23 12 Percent 5.9 5.70 0.21% Pass
*
Acid Rain Audit Linearity Third 2024
Low Span Gas Ranges High Span Gas Ranges
Low Mid High Low Mid High
Unit 1 NOx 9/4/24 250 62.9 50 to 75
Unit 1 NOx 9/4/24 250 137.8 125 to 150
Unit 1 NOx 9/4/24 250 234.1 200 to 250
Unit 1 O2 9/4/24 25 6.3 5 to 7.5
Unit 1 O2 9/4/24 25 14.04 12.5 to 15
Unit 1 O2 9/4/24 25 22.6 20 to 25
Unit 1 SO2 9/4/24 300 75.3 60 to 90
Unit 1 SO2 9/4/24 300 167.2 150 to 180
Unit 1 SO2 9/4/24 300 278.2 240 to 300
*
Type Code 280 (COMS Attenuator Filters) Procedure 3
Point Source Location
Attenuator
I.D.
Attenuator
Certification Date
Certified Attenuator
Opacity
OPLR,
SECR, or
PLCF,
Corrected Opacity
Value
Range
Low, Mid, & High
Certification
1-year or 5-year
Unit 1 Cal Check VT49 3/25/24 9 1 0 low 1 Year
Unit 1 Cal Check UU35 3/25/24 15 1 0.1 mid 1 Year
Unit 1 Cal Check UU36 3/25/24 25 1 0.1 high 1 Year
*
Opacity Monitor Response (Average of 5)
Low Range Mid Range High Range
Unit 1 Stack 9/5/24 9 0.100 0.040 0.039 0.139
Unit 1 Stack 9/5/24 15 -0.740 0.102 0.099 -0.641
Unit 1 Stack 9/5/24 25 0.040 0.049 0.048 0.088
*
Point Source Location Audit Date
Alternitive Zero
Alignment
(Yes or No)
COM Clear
Condition Zero
Response
(CCZR)
COM Simulated
Zero Response
(CSZR)
Zero Alignment
Error Difference
(CCZR)-(CSZR)
Adjustment to COM
Simulated Zero
Response
(CSZR)
(Yes or No)
Unit 1 Stack 6/12/24 No 0.000 -0.100 0.100 Yes
High SpanAudit Gas UsedPoint Source Channel Audit Date Low Span
Type Code 282 (Procedure 3 - Annual Zero Alignment Audit)
Audit Gas Used
Point
Source Location Audit Date Mean Difference Standard Deviation
Confidence
Coefficient
Calibration
Error (≤ 3%)
Type Code 281 (Procedure 3 - COMS Filter Audit Calibration Error)
Sunnyside EER 3Q2024
Monitoring Information TC 210, 230, & 240
Type Code 210
(Pollutant Concentration Exceeded Span of CEM) - 500 (All)
*
Sum of Hours Column Labels
Row Labels (blank) Grand Total
(blank)0 0
Grand Total 0 0
*
Type Code 230
(Manual Sample - Alternate Sampling During Monitor Outage) - 500 (All)
*
Sum of Hours Column Labels
Row Labels (blank) Grand Total
(blank)0 0
Grand Total 0 0
*
Type Code 240
(CEM Modifications) - 100 (All)
*
Count of Channel Column Labels
Row Labels (blank) Grand Total
(blank)
(blank)
Grand Total
Sunnyside EER 3Q2024
Type Code 220
(Monitor Outage During Point Source Operation) - 600 (All)
*
Sum of Hours Column Labels
Row Labels 726 721 724 723 Grand Total
Unit 1
NOx
Failed Calibrations 32 32
Failed sample pump. Pump was rebuilt and system recalibrated 6 6
#N/A 5 5
General Maintenance 4 4
CGA/Linearity tests 3 3
SO2
Failed Calibrations 8 8
Failed sample pump. Pump was rebuilt and system recalibrated 6 6
#N/A 5 5
General Maintenance 4 4
CGA/Linearity tests 3 3
O2
Failed Calibrations 8 8
Failed sample pump. Pump was rebuilt and system recalibrated 6 6
#N/A 5 5
General Maintenance 4 4
CGA/Linearity tests 3 3
Opacity
Failed Calibrations 1.9 1.9
#N/A 25.8 1.4 27.2
Grand Total 49.9 58.8 12 10.4 131.1
Sunnyside EER 3Q2024
Opy *
Opy Count of Magnitude of Emissions Column Labels
Opy Row Labels Grand Total
Opy Grand Total
SO2 *
SO2 Type Code 410 (SO2) - 6000 (All)
SO2 *
SO2 Count of Magnitude of Emissions Column Labels
SO2 Row Labels Grand Total
SO2 Grand Total
NOx d *
NOx d Type Code 421 (Daily NOx Emissions) - 500 (All)
NOx d *
NOx d Count of Reason Code Column Labels
NOx d Row Labels 701 704 726 Grand Total
NOx d Unit 1
NOx d #N/A 83 83
NOx d Failed Calibrations 4 4
NOx d Startup/shutdown/Black plant/outage 5 5
NOx d Grand Total 5 83 4 92
Dat Ex *
Dat Ex Type Code 450
(Data Excluded) - 6000 (All)
Dat Ex *
Dat Ex Count of Channel Column Labels
Dat Ex Row Labels 726 721 Grand Total
Dat Ex Unit 1
Dat Ex NOx 4 3 7
Dat Ex Failed Calibrations 4 4
Dat Ex Failed sample pump. Pump was rebuilt and system recalibrated 1 1
Dat Ex #N/A 2 2
Dat Ex SO2 1 3 4
Dat Ex Failed Calibrations 1 1
Dat Ex Failed sample pump. Pump was rebuilt and system recalibrated 1 1
Dat Ex #N/A 2 2
Dat Ex O2 1 3 4
Dat Ex Failed Calibrations 1 1
Dat Ex Failed sample pump. Pump was rebuilt and system recalibrated 1 1
Dat Ex #N/A 2 2
Dat Ex Opacity 1 1 2
Dat Ex Failed Calibrations 1 1
Dat Ex #N/A 1 1
Dat Ex Grand Total 7 10 17
O2 *
O2 Type Code 470
(TRS as O2) - 6000 (All)
O2 *
O2 Count of Magnitude of Emissions Column Labels
O2 Row Labels Grand Total
O2 Grand Total
Sunnyside EER 3Q2024
Type Code 500
Before February 28, 2005 (Boiler Operating Days w/o 18 Hours of
Data) After February 28, 2005 (90% Operating Hours For each 30 BOD)
- 500
(All)
*
Count of Channel Column Labels
Row Labels 726 Grand Total
Unit 1
SO2 1 1
Failed Calibrations 1 1
NOx 4 4
Failed Calibrations 4 4
O2 1 1
Failed Calibrations 1 1Grand Total 6 6
*
Type Code 510
(F-factor, Equations & Conversion Factors) - 500 (All)
Count of F-factor Column Labels
Row Labels SO2 NOx Grand Total
Unit 1
9780 1 1 2
Grand Total 1 1 2
*
Type Code 520
(Minimum Data Not
Obtained <22/30 BODs) - 500
(All)
Count of Channel Column Labels
Row Labels Grand Total
Grand Total
*
Type Code 530
(Excess Emissions During Emergency Conditions) - 500 (All)
Count of Date Column Labels
Row Labels Grand TotalGrand Total
*
Type Code 540
(Fuel Pre-treatment Credit SO2) - 500 (All)
Count of Date Column Labels
Row Labels Grand Total
Grand Total
*
TypeCode 550
(Changes in Operation in Control Equipment When CEM Data Not
Available) - 500
(All)
Column Labels
Row Labels Grand Total
Grand Total