DERR-2024-012059
pei.org 49 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities APPENDIX C-9 MECHANICAL AND ELECTRONIC LINE LEAK DETECTORS PERFORMANCE TEST )DFLOLW\1DPH2ZQHU $GGUHVV$GGUHVV &LW\6WDWH=LS&RGH&LW\6WDWH=LS&RGH )DFLOLW\,'3KRQH 7HVWLQJ&RPSDQ\3KRQH'DWH 7KLVGDWDVKHHWFDQEHXVHGWRWHVWPHFKDQLFDOOLQHOHDNGHWHFWRUV0//'DQGHOHFWURQLFOLQHOHDNGHWHFWRUV(//'ZLWKVXEPHUVLEOH WXUELQHSXPS673V\VWHPV6HH3(,536HFWLRQVDQGIRUWHVWSURFHGXUHV /LQH1XPEHU 3URGXFW6WRUHG /HDN'HWHFWRU0DQXIDFWXUHU /HDN'HWHFWRU0RGHO 7\SHRI/HDN'HWHFWRU 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' 0//' (//' MLLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH &KHFN9DOYH+ROGLQJ3UHVVXUH /LQH5HVLOLHQF\POOLQHEOHHGEDFNYRO XPHDVPHDVXUHGIURPFKHFNYDOYHKROG LQJSUHVVXUHWR]HURSVLJ 6WHS7KURXJK7LPHLQ6HFRQGVWLPHWKH 0//'KHVLWDWHVDWPHWHULQJSUHVVXUH EHIRUHJRLQJWRIXOORSHUDWLQJSUHVVXUH DVPHDVXUHGIURPSVLJZLWKQROHDN LQGXFHGRQWKHOLQH 0HWHULQJ3UHVVXUH673SUHVVXUHZKHQ VLPXODWHGOHDNUDWHJSKDWSVLJ 2SHQLQJ7LPHLQ6HFRQGVWKHWLPHWKH 0//'RSHQVWRDOORZIXOOSUHVVXUHDIWHU VLPXODWHGOHDNLVVWRSSHG 'RHVWKH673SUHVVXUHUHPDLQDWRU EHORZWKHPHWHULQJSUHVVXUHIRUDWOHDVW VHFRQGVZKHQWKHVLPXODWHGOHDNLV LQGXFHG" <HV1R<HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKHOHDNGHWHFWRUUHVHWWULSZKHQ WKHOLQHSUHVVXUHLVEOHGRIIWR]HURSVLJ"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R 'RHVWKH673SURSHUO\F\FOHRQRIIXQGHU QRUPDOIXHOV\VWHPRSHUDWLRQFRQGLWLRQV"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRHLWKHURIWKHDERYHTXHVWLRQVLQGLFDWHVWKH0//'IDLOVWKHWHVW ELLD (ALL PRESSURE MEASUREMENTS ARE MADE IN PSIG) 673)XOO2SHUDWLQJ3UHVVXUH +RZPDQ\WHVWF\FOHVDUHREVHUYHG EHIRUHDODUPVKXWGRZQRFFXUV" 'RHVWKHVLPXODWHGOHDNFDXVHDQDODUP"<HV1R <HV1R <HV1R <HV1R <HV1R <HV1R $´1RµDQVZHUWRWKHDERYHTXHVWLRQLQGL FDWHVWKH(//'IDLOVWKHWHVW 'RHVWKHVLPXODWHGOHDNFDXVHDQ673 VKXWGRZQ" <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ <HV1R 1$ Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPH BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Maverik #561 13551 S 200 W Draper, UT 84020 4002340 Maverik, Inc 185 S State ST STE 800 Salt Lake City Utah 84111 801-910-7062 11/01/2024 1 Unleaded VR PLLD 4 30 2 4 4 4 2 Premium VR PLLD 4 29 2 4 4 4 3 Diesel VR PLLD 4 33 2 4 4 4 Dominic Salas UT-378 pei.org 43 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities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est Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: $OOOLTXLGVDQGGHEULVPXVWEHGLVSRVHGRISURSHUO\ 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Maverik #561 4002340 11/01/2024 1 Unleaded 5 Gal OPW 4 4 4 4 4 4 2 Premium 5 Gal OPW 4 4 4 4 4 4 3 Diesel 5 Gal OPW 4 4 4 4 4 4 Dominic Salas UT-378 pei.org 47 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities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´1RµWKHV\VWHPKDVIDLOHGWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Maverik #561 4002340 1 UNL VRTLS 450+ 15104 119 4 4 4 4 99 3/4 4 1 4 4 2 PRM VRTLS 450+ 11595 91.5 4 4 4 4 76 7/8 4 1 4 4 3 DSL VRTLS 450+ 9696 91.5 4 4 4 4 76 3/4 4 2 4 4 11/01/2024 Dominic Salas UT-378 PE I / R P 1 2 0 0 - 1 2 pe i . o r g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´1RµDQVZHUVLQGLFDWHVWKHVHQVRUIDLOVWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Maverik #561 4002340 11/01/2024 Disp 1/2 Lines 4 4 4 4 4 4 4 4 3/4 Lines 4 4 4 4 4 4 4 4 5/6 Lines 4 4 4 4 4 4 4 4 7/8 Lines 4 4 4 4 4 4 4 4 9/10 Lines 4 4 4 4 4 4 4 4 11/12 Lines 4 4 4 4 4 4 4 4 Unl STP Unleaded 4 4 4 4 4 4 4 4 Dominic Salas UT-378 PE I / R P 1 2 0 0 - 1 2 pe i . o r g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´1RµDQVZHUVLQGLFDWHVWKHVHQVRUIDLOVWKHWHVW Test Results 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO 3DVV)DLO Comments: 7HVWHU·V1DPHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 7HVWHU·V6LJQDWXUHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB Precision Testing Technologies Inc.801-886-9224 Maverik #561 4002340 11/01/2024 PRM STP Premium 4 4 4 4 4 4 4 4 DSL STP Diesel 4 4 4 4 4 4 4 4 Dominic Salas UT-378