Loading...
HomeMy WebLinkAboutDERR-2024-011929FUEL SYSTEMS | GENERAL CONTRACTING | ENVIRONMENTAL SERVICES | WASTE SOLUTIONS ENERGY SOLUTIONS | AUTOMOTIVE & COMMERCIAL EQUIPMENT P.O. BOX 3360 DES MOINES, IA 50316 4140 E. 14TH STREET DES MOINES, IA 50313 PHONE: 515-262-5000 CORPORATE HEADQUARTERS WWW.SENECACO.COM STORE.SENECACO.COM 6HQHFD$FFRXQW5HS 3KRQH 'DWHRI7HVW 6FRSHRI:RUN 6HQHFD-RE &XVWRPHU32 7HFKQLFLDQ &HUWLILFDWLRQ VHHWHVWUHSRUWVDWWDFKHG 7HVWLQJ6XPPDU\ 7HVW6XPPDU\'HVFULSWLRQ &RPSRQHQW7HVWHG 'DWH7HVWHG 5HVXOW &XVWRPHU,QIRUPDWLRQ 1DPH 6WUHHW $GGUHVV &LW\ 6WDWH =LS &RQWDFW 3KRQH 1XPEHU 6LWH,QIRUPDWLRQ 6LWH1DPH Testing Summary 6WUHHW $GGUHVV &LW\ 6WDWH =LS )DFLOLW\1R 10/14/24 TLT-W2401122 CT - Hydro Testing Holiday Oil Company 3115 West 2100 South West Valley City UT 84119 Gideon Baxter 801-973-7002 Holiday Oil #18 4825 W 4100 S West Valley UT 84120 4000392 Containment Test 3 STPs, 4 UDCs 10/14/2024 Pass Containment Test 1 Clr STP 10/14/2024 Fail Mark Shirley Garrett Herlache 515-262-5000 )LHOG1RWHV 4140 E. 14TH STREET DES MOINES, IA 50313 PHONE: 515-262-5000 CORPORATE HEADQUARTERS P.O. BOX 3360 DES MOINES, IA 50316 WWW.SENECACO.COM STORE.SENECACO.COM Testing Summary 7HVWLQJ6XPPDU\ FUEL SYSTEMS | GENERAL CONTRACTING | ENVIRONMENTAL SERVICES | WASTE SOLUTIONS ENERGY SOLUTIONS | AUTOMOTIVE & COMMERCIAL EQUIPMENT Site Location - Holiday Oil 18 West Valley, UT Job #: TLT-W2401122 Arrived on site and checked in with manager. Opened sumps and dispenser and then began testing. Dri Sump SB – n/a Dri Sump Sumps – Tested/ Clr STP fails due to water level dropping. STP lost 7 1/2 inches of water in the 1 hr time frame. waited to see where the level would drop down to. Water is not entering tank. Dri Sump UDC – Tested/Passed Spill Bucket Hydro – n/a SB / Low Level – n/a Stage 1 Pressure Decay- n/a ATG/AMC – n/a Tank Test- n/a Line Test- n/a Leak Detector – n/a SV/ESO – n/a OVERFILL- n/a Walk Thru Insp- n/a AST inspection- n/a Seneca Companies, Inc 515-262-5000 Holiday Oil #18 4825 W 4100 S West Valley UT 84120 4000392 Holiday Oil Company 3115 West 2100 South West Valley City UT 84119 801-973-7002 10/14/24 Unl STP FRP ✔ ✔ 37 16 20 0 20 1 hr Y 0 ✔ Prm STP FRP ✔ ✔ 38 17 21 0 21 1 hr Y 0 ✔ X X X X Garrett Herlache Seneca Companies, Inc 515-262-5000 Holiday Oil #18 4825 W 4100 S West Valley UT 84120 4000392 Holiday Oil Company 3115 West 2100 South West Valley City UT 84119 801-973-7002 10/14/24 Dsl STP FRP ✔ ✔ 37 16 1,2 20 1/2 0 20 1/2 1 hr Y 0 ✔ Clr STP FRP ’ ✔ 38 16 20 0 13 1/2 1 hr Y 7 1/2 ✔ Disp 1,2 FRP ✔ ✔ 24 8 12 0 12 1 hr Y 0 ✔ 3,4 FRP ✔ ✔ 23 8 12 0 12 1 hr Y 0 ✔ 5,6 FRP ✔ ✔ 24 9 13 0 13 1 hr Y 0 ✔ 7,8 FRP ✔ ✔ 24 8 12 0 12 1 hr Y 0 ✔ Garrett Herlache )8(/6<67(06_*(1(5$/&2175$&7,1*_(19,5210(17$/6(59,&(6_:$67( 62/87,21(1(5*<62/87,216_$872027,9( &200(5&,$/(48,30(17 6LWH1DPH6LWH$GGUHVV-RE &LW\6WDWH =LS 'DWH 6FRSHRI :RUN $UULYDO7LPHWR 6LWH'HSDUWXUH7LPHIURP6LWH '3OHDN6XPS6% &DWKRGLF3URWHFWLRQ  0&//' 9DSRU5HFRYHU\ &DOLEUDWLRQ 7HFKQLFLDQ3RVW7HVW6LJQDWXUH %\VLJQLQJEHORZ \RXFRQILUPWKDWWKHLWHPVOLVWHGDERYHKDYHEHHQYLVXDOO\ YHULILHGE\\RX 6LWH&RQWDFW3RVW7HVW6LJQDWXUH ,QVSHFWRURQVLWH" <HV 1R ,I\HVSOHDVHJLYHQDPH 6HUYLFH7HVWLQJ $ $OO % 7HVWLQJ <HV1R 1RWHV $OOVKHDUYDOYHVKDYHEHHQVHWWRRSHQ LIDSSOLFDEOH  7HVWLQJDQG6HUYLFH(QYLURQPHQWDO&KHFNOLVW 'LVSDWFK7\SH 4140 E. 14TH STREET DES MOINES, IA 50313 PHONE: 515-262-5000 CORPORATE HEADQUARTERS P.O. BOX 3360 DES MOINES, IA 50316 WWW.SENECACO.COM STORE.SENECACO.COM 7HVWHUV PXVW XSORDGDFRS\ RI WKLV FRPSOHWHG IRUP ZLWKUHSRUWVSKRWRV DQGHPDLOWR0DUN 6KLUOH\ DQG(PPD3HWURZLW] Dispenser/Tank Sump free of all tools, liquid & debris upon completion of work? Were any sensors replaced? Programming on Monitoring Console checked for positive shutdown? All containment & UDC sensors returned to proper placement & locked (if applicable). All containment lids & retaining bolts securely fastened (if applicable). All dispenser door panels are closed & locked. Flint Loc/security alarms activated (if applicable). All test gauges/test isolation devices were properly removed. All secondary containment boots have been pulled back/removed. All site owned keys have been returned to site manager/representative. All monitor alarms generated have been logged & responded to appropriately. Monitor is free of alarms & displaying All Functions Normal. Holiday Oil #18 4825 W 4100 S TLT-W2401122 West Valley UT 84120 10/14/24 CT - Hydro Testing 11:00 ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ Garrett Herlache Gideon Baxter ✔