Loading...
HomeMy WebLinkAboutDDW-2024-012921Contacts Type: Administrative Contact Name: SCOTT ATWOOD Office: 435-383-2347 Emergency: Email: scott.atwood@kodares.com Site Information Legal Contact: CT CORPORATION SYSTEM Address: 1108 EAST SOUTH UNION AVENUE , MIDVALE, UT 84047 Phone: 801-784-6883 County: UINTAH COUNTY System Type: Non-Transient Certification Required: Total Population: 65 Local Health District: Tri-County Health Department Site Updates Last Inventory Update: 08/29/2024 Last Surveyor Update: 08/28/2024 Surveyor: NATHAN HALL Operating Period: 1/1 - 12/31 Last IPS Update: 09/16/2024 12:10:00 Political Districts Legislative District Map Water Usage Information per ERC Total Ips Points: 0 Public Water System IPS ReportDEQ | Drinking Water Red Wash PWS ID: UTAH24020 Rating:Status: Active IPS SUMMARY Total IPS Points: 0 Admin & Physical Facilities Quality & Monitoring Significant Deficiency Violations 0 0 0 PHYSICAL FACILITY POINTS Total Pts: 0 Facility Facility Name Status Points Effective Details DS001 UTAH24020 DISTRIBUTION SYSTEM A 0 Hide Details ( 2 ) Code Description Severity Comments Determined Date Pending Assessed G001 UNAPPROVEDFACILITY IN SERVICE SIG SYSTEM MUST OBTAIN OP FOR ALL WATERSYSTEM FACILITIES BY 9/28/2025 03/28/2024 50 0 C001 SYSTEM DIRECT RESPONSIBLE CHARGE OPERATORS NOT CERTIFIED AT THE REQUIRED LEVEL SIG SYSTEM MUST OBTAIN A SMALL SYSTEMS DIRECT RESONSIBLE CHARGE OPERATOR BY3/27/2025.03/28/2024 50 0 ST001 RED WASH TANK #1 A 0 Hide Details ( 1 ) Code Description Severity Comments DeterminedDate Pending Assessed V009 STORAGE TANK LID LACKS A FUNCTIONING GASKET BETWEEN THE LID AND FRAME SIG The threaded access did not have a gasket 08/28/2024 25 0 ST002 RED WASH TANK #2 A 0 Hide Details ( 1 ) Code Description Severity Comments DeterminedDate Pending Assessed V009 STORAGE TANK LID LACKS A FUNCTIONING GASKET BETWEEN THE LID AND FRAME SIG The threaded access did not have a gasket 08/28/2024 25 0 SIGNIFICANT DEFICIENCY VIOLATIONS Total Pts: 0 ID Violation Code Deficiency Determined Points Effective LEAD COPPER MONITORING AND QUALITY VIOLATIONS Total Pts: 0 Violation No.Period Code Description/Name Points Effective CHEMICAL MONITORING RULE VIOLATIONS Total Pts: 0 Facility Violation No Period Code Violation Type Analyte Group Determined Seasonality Points Effective TREATMENT VIOLATIONS Total Pts: 0 Facility Violation No Period Code Violation Type Analyte Group Determined Points Effective MICROBIAL RULE VIOLATIONS Date Range Start: 07/01/2023 Total Pts: 0 Determine Date Compliance Period Code Violation Type Return To Compliance Points Effective OPERATOR CERTIFICATION Type Level Required Highest Certificate Distribution Treatment CONSUMER CONFIDENCE REPORT Total Effective Points: 0 Violation No.Period Code Description/Name Points Effective PUBLIC NOTIFICATION VIOLATIONS Total Pts: 0 Violation No.Date Code Description/Name Points Effective IPS COMPLIANCE SCHEDULES Type Required Activities Severity Created Due Physical deficiency schedule STORAGE TANK LID LACKS A FUNCTIONING GASKET BETWEEN THE LID AND FRAME SIG 09/05/2024 01/03/2025 Physical deficiency schedule STORAGE TANK LID LACKS A FUNCTIONING GASKET BETWEEN THE LID AND FRAME SIG 09/05/2024 01/03/2025 Lead Consumer Notice SUBMIT LCN CERTIFICATE 07/01/2024 03/31/2025 WELCOME TO THE CLUB LETTER SCHEDULE ONSITE INSPECTION/SANITARY SURVEY 03/28/2024 03/27/2025 WELCOME TO THE CLUB LETTER SCHEDULE CAPACITY DEVELOPMENT EVALUATION 03/28/2024 03/27/2025 WELCOME TO THE CLUB LETTER SCHEDULE ENGINEERING EVALUATION REPORT 03/28/2024 12/31/2024 WELCOME TO THE CLUB LETTER SCHEDULE GWR CORRECT DEFICIENCY 120 DAYS SIG 03/28/2024 12/31/2025 WELCOME TO THE CLUB LETTER SCHEDULE GWR CORRECT DEFICIENCY 120 DAYS SIG 03/28/2024 06/30/2025 Disinfection Byproduct Sample Site Plan SUBMIT DBP SAMPLE SITE PLAN 02/23/2024 06/30/2025 Lead Copper Rule Revisions SUBMIT LEAD SERVICE LINE INVENTORY 12/16/2021 10/16/2024 Lead Copper Rule Revisions COMPLETE INITIAL LSL INVENTORY 12/16/2021 10/16/2024