Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DERR-2024-011846
Annual Sump Inspection IMPACT VALVE LEAK DETECTOR Line Tightness Test MONITOR CERTIFICATION SPILL BUCKET TEST STAGE I SURVEY 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 10/25/2024 UTAH DEPARTMENT OF ENV. QUALITY UST PO Box 144840 SALT LAKE CITY, UT 84114 Test Date: 10/16/2024 Order Number: 2372290 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: WAL-MART #3568 (WM3568) 3180 S 5600 W West Valley City, UT 84120 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting Product Line Tightness Test Page 1 of 1 Work Order: 2372290 Date: 10/16/2024 Site Name/ID: WAL-MART #3568 / WM3568 Address: 3180 S 5600 W City: West Valley City State: UT Zip: 84120 Tank Information Test Method Customer Tank ID Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Tank # 1 Line # 1 TLD-1 1 UNLEADED Pressure 60 06:49 07:49 0.00 Pass Yes Tank # 2 Line # 1 TLD-1 2 PREMIUM Pressure 60 06:49 07:49 0.00 Pass Yes Tank # 3 Line # 1 TLD-1 3 Low Sulfur Diesel Pressure 60 06:49 07:49 0.00 Pass Yes Tank # Line # Tank # Line # Tank # Line # Technician Comments: Ut151 Rul prem tested to stp Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com WAL-MART #3568 3180 S 5600 W West Valley City UT 84120 WM3568 Tanknology, Inc. WALMART/SAM'S CLUB DEPT. 9641 2101 SE Simple Savings Dr. BENTONVILLE AR 72716 479-360-2779 10/16/2024 UNLEADED PREMIUM Veeder Root FX1V Veeder Root FX1V Veeder Root FX1V 33 20 200 2 10 3 40 20 200 2 10 3 30 20 150 2 10 3 Ut151 David Mathie NW1-2372290 Low Sulfur Diesel T1:1 T2:1 T3:1 Impact Valve Inspection Impact Valve Operational Inspection Work Order:2372290 Date:10/16/2024 Site Name/ID:WAL-MART #3568 Address:3180 S 5600 W City:West Valley City State:UT Zip:84120 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 40 Pass Fail Not Tested 1/2 85 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 85 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 85 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 85 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested 9/10 85 Pass Fail Not Tested 9/10 91 Pass Fail Not Tested 11/12 40 Pass Fail Not Tested 11/12 85 Pass Fail Not Tested 11/12 91 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com WAL-MART #3568 WALMART/SAM'S CLUB 3180 S 5600 W West Valley City UT 84120 WM3568 Tanknology, Inc. DEPT. 9641 2101 SE Simple Savings Dr. BENTONVILLE AR 72716 479-360-2779 800-964-1250 10/16/2024 1 2 3 Rul Prem Dsl 450 PLU$450 PLU$450 PLU$ 19782 11904 7901 118.4 118.4 118.4 Ut151 David Mathie 3180 S 5600 W WAL-MART #3568 3180 S 5600 W, West Valley City, UT 84120 WM3568 Tanknology, Inc. WALMART/SAM'S CLUB DEPT. 9641 2101 SE Simple Savings Dr. BENTONVILLE, AR 72716 479-360-2779 10/16/2024 Annular Annular Stp Stp Stp Udc Udc Rul Prem/Dsl Rul Prem Dsl 1/2 3/4 Ut151 David Mathie 3180 S 5600 W WAL-MART #3568 3180 S 5600 W, West Valley City, UT 84120 WM3568 Tanknology, Inc. WALMART/SAM'S CLUB DEPT. 9641 2101 SE Simple Savings Dr. BENTONVILLE, AR 72716 479-360-2779 10/16/2024 Udc Udc Udc Udc 5/6 7/8 9/10 11/12 Ut151 David Mathie WAL-MART #3568 3180 S 5600 W West Valley City, UT 84120 WM3568 Tanknology, Inc. WALMART/SAM'S CLUB 479-360-2779 10/16/2024 DEPT. 9641 2101 SE Simple Savings Dr. BENTONVILLE, AR 72716 1 Rul 5 OPW 2 Prem 5 Opw 3 Dsl 5 Opw 15 Wc 738 15 Wc 743 5 min 0 15 Wc 745 15 Wc 750 5 min 0 15 Wc 753 15 Wc 758 5 min 0 Ut151 David Mathie Stage I Vapor System Survey Survey to determine compliance with Requirements of Title 40 Part 63 National Emission Standards for Hazardous Air Pollutants for Source Categories Survey Date 10/16/2024 Work Order 2372290 Cust Name / Location Number WM3568 Street Address 3180 S 5600 W City, State, ZipCode West Valley City UT 84120 Product Stage I Type Drop Tubes Type Drop Tubes Max inches from tank Bottom Fill Adapters Type Vapor Adapters Type NESHAP Work Required? Vent Caps Type Labeled Positive Cracking Pressure Labeled Negative Cracking Pressure 1 UNLEADED Dual Point Straight w/ Flapper 3.00 Swivel Swivel (poppet) No 2 PREMIUM Dual Point Straight w/ Flapper 3.75 Swivel Swivel (poppet) No GAS Pressure Vacuum cap 3 8 Describe Work Required Surveyed by Signature ANNUAL CONTAINMENT SUMP INSPECTION This form may be utilized to document the inspection of containment sumps. Date of Inspection 10/16/2024 UST Facility Person Conducting Test Facility Name WAL-MART #3568 Facility ID # WM3568 Tester's Name DMATHIE Physical Address 3180 S 5600 W Company Tanknology Inc. City West Valley City County SALT LAKE State UT Certification # 41442 Expiration Date 10/20/2025 UST Owner WALMART/SAM'S CLUB Tester's Signature Date 10/16/2024 Containment Sump Inspection Sump Material of Construction Fiberglass Reinforced Plastic Thermoplastic Steel Composite Containment Sump Inspection Procedure 1. Clean-out and properly dispose of all debris, soil and/or fluids from the containment sump. 2. Visually examine the containment sump to ensure there are no cracks, holes, deteriorated seals, deformation or other indications that the sump is not liquid tight. 3. If the sump appears to be liquid tight and no water was in the sump, the inspection result is "pass" and no further action is required. 4. If the sump appears to be liquid tight but water was present within the sump, the inspection result is "fail". 5. If there is visual evidence that the sump is not liquid tight, then repair or replacement (see note below) of the sump is required. Inspection Results for the Year 2024 Sump ID (product stored for STP or dispenser number) Sump lid/gasket in good condition (yes/no) Sump is dry (yes/no) All penetration fittings in good condition (yes/no) Sump walls/bottom in good condition (yes/no) Are there any leaks from pipe components (yes/no) Inspection Result (Pass/Fail) STP:1 UNLEADED - 1 Y Y Y Y N Pass STP:2 PREMIUM - 1 Y Y Y Y N Pass STP:3 Low Sulfur Diesel - 1 Y Y Y Y N Pass Comments: WO: 2372290 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2372290 Site ID / Name:WM3568 / WAL-MART #3568 Address:3180 S 5600 W City:West Valley City State:UT Zip:84120 W.O.# NW1-2372290 +AAE- I10100 10/16/24 8:25 AM 848628 Walmart SUP +ACM-3568 3180 South 5600 West West Valley UT 84120 SYSTEM STATUS REPORT ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME ALL FUNCTIONS NORMAL +AAMAAQ- I90200 10/16/24 8:25 AM SOFTWARE REVISION LEVEL VERSION 33.48 SOFTWARE+ACM- 342005-010-B- CREATED - 21.10.28.21.27 +AAMAAQ- I20100 10/16/24 8:25 AM 848628 Walmart SUP +ACM-3568 3180 South 5600 West West Valley UT 84120 IN-TANK INVENTORY TANK PRODUCT VOLUME TC-VOLUME ULLAGE HEIGHT WATER TEMP 1 T1-Unleaded 11630 0 8152 67.17 0.00 75.68 2 T2-Premium 4762 0 7142 50.43 0.00 79.28 3 T3-Diesel 5640 0 2261 79.44 0.00 81.94 +AAMAAQ- I30100 10/16/24 8:25 AM 848628 Walmart SUP +ACM-3568 3180 South 5600 West West Valley UT 84120 LIQUID STATUS REPORT SENSOR LOCATION STATUS 1 Unld. T1 STP Sump Normal 2 Prem. T2 STP Sump Normal 3 DIE. T3 STP Sump Normal 4 Unld. T1 Int. Space Normal 5 Prem./ DIE T2/T3 Int Normal 6 UDC FP 1-2 Normal 7 UDC FP 3-4 Normal 8 UDC FP 5-6 Normal 9 UDC FP 7-8 Normal 10 UDC FP 9-10 Normal 11 UDC FP 11-12 Normal +AAMAAQ- I30200 10/16/24 8:25 AM 848628 Walmart SUP +ACM-3568 3180 South 5600 West West Valley UT 84120 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 Unld. T1 STP Sump 10/16/24 6:56 AM FUEL ALARM 10/18/23 6:38 AM FUEL ALARM 10/24/22 6:25 AM FUEL ALARM 10/26/21 9:38 AM FUEL ALARM 2 Prem. T2 STP Sump 10/16/24 6:58 AM FUEL ALARM 05/02/24 12:07 PM FUEL ALARM 05/01/24 12:33 PM SENSOR OUT ALARM 04/29/24 4:19 PM FUEL ALARM 10/18/23 6:39 AM FUEL ALARM 06/14/23 8:26 AM FUEL ALARM 02/03/23 12:21 PM FUEL ALARM 10/24/22 6:30 AM FUEL ALARM 04/19/22 8:22 PM FUEL ALARM 10/26/21 9:39 AM FUEL ALARM 3 DIE. T3 STP Sump 10/16/24 6:58 AM FUEL ALARM 05/01/24 12:24 PM SENSOR OUT ALARM 10/18/23 6:40 AM FUEL ALARM 10/24/22 6:28 AM FUEL ALARM 10/26/21 9:39 AM FUEL ALARM 4 Unld. T1 Int. Space 10/16/24 7:18 AM FUEL ALARM 10/18/23 6:47 AM FUEL ALARM 10/24/22 6:50 AM FUEL ALARM 10/26/21 9:44 AM FUEL ALARM 5 Prem./ DIE T2/T3 Int 10/16/24 7:20 AM FUEL ALARM 10/18/23 6:51 AM FUEL ALARM 10/24/22 7:04 AM FUEL ALARM 10/26/21 9:51 AM FUEL ALARM 6 UDC FP 1-2 10/16/24 6:43 AM FUEL ALARM 10/18/23 6:28 AM FUEL ALARM 12/03/22 4:43 PM FUEL ALARM 10/24/22 6:42 AM FUEL ALARM 10/26/21 10:03 AM FUEL ALARM 7 UDC FP 3-4 10/16/24 6:43 AM FUEL ALARM 06/18/24 3:56 PM SENSOR OUT ALARM 10/18/23 6:29 AM FUEL ALARM 10/24/22 6:42 AM FUEL ALARM 10/26/21 10:03 AM FUEL ALARM 8 UDC FP 5-6 10/16/24 6:43 AM FUEL ALARM 10/18/23 6:29 AM FUEL ALARM 10/24/22 6:43 AM FUEL ALARM 10/26/21 10:04 AM FUEL ALARM 9 UDC FP 7-8 10/16/24 6:44 AM FUEL ALARM 10/18/23 6:30 AM FUEL ALARM 10/24/22 6:43 AM FUEL ALARM 10/26/21 10:04 AM FUEL ALARM 10 UDC FP 9-10 10/16/24 6:44 AM FUEL ALARM 10/18/23 6:30 AM FUEL ALARM 10/24/22 6:44 AM FUEL ALARM 12/14/21 9:12 PM SENSOR OUT ALARM 10/26/21 10:06 AM FUEL ALARM 11 UDC FP 11-12 10/16/24 6:44 AM FUEL ALARM 10/18/23 6:31 AM FUEL ALARM 10/24/22 6:44 AM FUEL ALARM 10/26/21 10:05 AM FUEL ALARM +AAMAAQ- I6SU00 10/16/24 8:25 AM -------------------------------------------------------- +ACoAKgAq- SETUP FOR ALL TANKS +ACoAKgAq- -------------------------------------------------------- ULLAGE DISPLAY MODE: FULL ULLAGE USER ULLAGE FULL ULLAGE LABEL: 100+ACU- ULLAGE USER ULLAGE: 90+ACU- PRINT TC VOLUMES: DISABLED TC REFERENCE TEMPERATURE: 60 DEG F PERIODIC TEST NEEDED WARNINGS: DISABLED DAYS BEFORE PERIODIC WARNING: 25 DAYS BEFORE PERIODIC ALARM: 30 ANNUAL TEST NEEDED WARNINGS: DISABLED DAYS BEFORE ANNUAL WARNING: 355 DAYS BEFORE ANNUAL ALARM: 365 TC DENSITY: DISABLED STICK HEIGHT: DISABLED LEAK TEST REPORT FORMAT: STANDARD LEAK TEST REGION: EPA -------------------------------------------------------- +ACoAKgAq- TANK SETUP +ACoAKgAq- -------------------------------------------------------- --- GENERAL SETUP - TANK 1 --- CONFIGURED: ENABLED LABEL: T1-Unleaded PRODUCT CODE: 1 PROBE NUMBER: Pb 1: Unld. Tk +ACM-1 Probe PROBE OFFSET: 0.00 INCHES FULL VOLUME: 19782 GALLONS DIAMETER: 118.4 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000700 METER DATA PRESENT: ENABLED DELIVERY DELAY: 5 MINUTES GROSS TEST FAIL: ALARMS DISABLED PERIODIC TEST FAIL: ALARMS DISABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 1 --- MAX VOLUME: 19782 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 0+ACU- LOW PRODUCT: 600 GALLONS HIGH WATER WARNING: 1.00 INCHES HIGH WATER ALARM: 3.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 15 GALLONS SUDDEN LOSS LIMIT: 50 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 1 --- TANK TEST METHOD: SLD LEAK TEST RATE: 0.2 gph PERIODIC TEST TYPE: STANDARD TEST FREQUENCY: On Date 01/00/0000 00:00 DURATION: 2 HOURS LEAK MIN PERIODIC (+ACU-FULL VOL): 0.0 +ACU- LEAK MIN ANNUAL (+ACU-FULL VOL): 0.0 +ACU- EARLY STOP: DISABLED TANK TEST NOTIFY: OFF TANK TEST SIPHON BREAK: OFF --- PROFILE - TANK 1 --- TANK PROFILE: FOUR POINT +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 118.4 19782 003 59.2 9883 002 88.8 16039 004 29.6 3735 --- TANK 1 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: FOUR POINT SOURCE: USER ENTERED LAST CHANGE: 2017-05-12 STATUS: ACTIVE VOLUME ENTRY: TOTAL VOLUME +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 118.4 19782 003 59.2 9883 002 88.8 16039 004 29.6 3735 --- TANK 1 --- T1 SIPHON MANIFOLDED TO TANKS: NONE T1 LINE MANIFOLDED TO TANKS: NONE --- ACCUCHART - TANK 1 --- UPDATE SCHEDULE: NEVER CALIBRATION PERIOD: 120 DAYS WARNINGS: DISABLED MIN OPERATING LEVEL: 10+ACU- MAX OPERATING LEVEL: 80+ACU- --- HRM - TANK 1 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS --- GENERAL SETUP - TANK 2 --- CONFIGURED: ENABLED LABEL: T2-Premium PRODUCT CODE: 2 PROBE NUMBER: Pb 2: Prem. Tk +ACM-2 Probe PROBE OFFSET: 0.00 INCHES FULL VOLUME: 11904 GALLONS DIAMETER: 118.4 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000700 METER DATA PRESENT: ENABLED DELIVERY DELAY: 5 MINUTES GROSS TEST FAIL: ALARMS DISABLED PERIODIC TEST FAIL: ALARMS DISABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 2 --- MAX VOLUME: 11904 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 0+ACU- LOW PRODUCT: 250 GALLONS HIGH WATER WARNING: 1.00 INCHES HIGH WATER ALARM: 3.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 15 GALLONS SUDDEN LOSS LIMIT: 50 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 2 --- TANK TEST METHOD: SLD LEAK TEST RATE: 0.2 gph PERIODIC TEST TYPE: STANDARD TEST FREQUENCY: On Date 01/00/0000 00:00 DURATION: 2 HOURS LEAK MIN PERIODIC (+ACU-FULL VOL): 0.0 +ACU- LEAK MIN ANNUAL (+ACU-FULL VOL): 0.0 +ACU- EARLY STOP: DISABLED TANK TEST NOTIFY: OFF TANK TEST SIPHON BREAK: OFF --- PROFILE - TANK 2 --- TANK PROFILE: FOUR POINT +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 118.4 11904 003 59.2 5936 002 88.8 9700 004 29.6 2183 --- TANK 2 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: FOUR POINT SOURCE: USER ENTERED LAST CHANGE: 2017-05-12 STATUS: ACTIVE VOLUME ENTRY: TOTAL VOLUME +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 118.4 11904 003 59.2 5936 002 88.8 9700 004 29.6 2183 --- TANK 2 --- T2 SIPHON MANIFOLDED TO TANKS: NONE T2 LINE MANIFOLDED TO TANKS: NONE --- ACCUCHART - TANK 2 --- UPDATE SCHEDULE: NEVER CALIBRATION PERIOD: 120 DAYS WARNINGS: DISABLED MIN OPERATING LEVEL: 10+ACU- MAX OPERATING LEVEL: 80+ACU- --- HRM - TANK 2 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS --- GENERAL SETUP - TANK 3 --- CONFIGURED: ENABLED LABEL: T3-Diesel PRODUCT CODE: 3 PROBE NUMBER: Pb 3: Diesel Tk +ACM-3 Probe PROBE OFFSET: 0.00 INCHES FULL VOLUME: 7901 GALLONS DIAMETER: 118.4 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000450 METER DATA PRESENT: ENABLED DELIVERY DELAY: 5 MINUTES GROSS TEST FAIL: ALARMS DISABLED PERIODIC TEST FAIL: ALARMS DISABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 3 --- MAX VOLUME: 7901 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 0+ACU- LOW PRODUCT: 250 GALLONS HIGH WATER WARNING: 1.00 INCHES HIGH WATER ALARM: 3.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 15 GALLONS SUDDEN LOSS LIMIT: 50 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 3 --- TANK TEST METHOD: SLD LEAK TEST RATE: 0.2 gph PERIODIC TEST TYPE: STANDARD TEST FREQUENCY: On Date 01/00/0000 00:00 DURATION: 2 HOURS LEAK MIN PERIODIC (+ACU-FULL VOL): 0.0 +ACU- LEAK MIN ANNUAL (+ACU-FULL VOL): 0.0 +ACU- EARLY STOP: DISABLED TANK TEST NOTIFY: OFF TANK TEST SIPHON BREAK: OFF --- PROFILE - TANK 3 --- TANK PROFILE: FOUR POINT +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 118.4 7901 003 59.2 3959 002 88.8 6358 004 29.6 1558 --- TANK 3 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: FOUR POINT SOURCE: USER ENTERED LAST CHANGE: 2017-05-12 STATUS: ACTIVE VOLUME ENTRY: TOTAL VOLUME +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 118.4 7901 003 59.2 3959 002 88.8 6358 004 29.6 1558 --- TANK 3 --- T3 SIPHON MANIFOLDED TO TANKS: NONE T3 LINE MANIFOLDED TO TANKS: NONE --- ACCUCHART - TANK 3 --- UPDATE SCHEDULE: NEVER CALIBRATION PERIOD: 120 DAYS WARNINGS: DISABLED MIN OPERATING LEVEL: 10+ACU- MAX OPERATING LEVEL: 80+ACU- --- HRM - TANK 3 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS +AAMAAQ- I70300 10/16/24 8:26 AM LIQUID MODEL SENSOR LABEL MODEL 1 Unld. T1 STP Sump Tri-State(Single Float) 2 Prem. T2 STP Sump Tri-State(Single Float) 3 DIE. T3 STP Sump Tri-State(Single Float) 4 Unld. T1 Int. Space Tri-State(Single Float) 5 Prem./ DIE T2/T3 Int Tri-State(Single Float) 6 UDC FP 1-2 Tri-State(Single Float) 7 UDC FP 3-4 Tri-State(Single Float) 8 UDC FP 5-6 Tri-State(Single Float) 9 UDC FP 7-8 Tri-State(Single Float) 10 UDC FP 9-10 Tri-State(Single Float) 11 UDC FP 11-12 Tri-State(Single Float) 12 Tri-State(Single Float) 13 Tri-State(Single Float) 14 Tri-State(Single Float) 15 Tri-State(Single Float) 16 Tri-State(Single Float) 17 Tri-State(Single Float) 18 Tri-State(Single Float) 19 Tri-State(Single Float) 20 Tri-State(Single Float) 21 Tri-State(Single Float) 22 Tri-State(Single Float) 23 Tri-State(Single Float) 24 Tri-State(Single Float) 25 Tri-State(Single Float) 26 Tri-State(Single Float) 27 Tri-State(Single Float) 28 Tri-State(Single Float) 29 Tri-State(Single Float) 30 Tri-State(Single Float) 31 Tri-State(Single Float) 32 Tri-State(Single Float) 33 Tri-State(Single Float) 34 Tri-State(Single Float) 35 Tri-State(Single Float) 36 Tri-State(Single Float) 37 Tri-State(Single Float) 38 Tri-State(Single Float) 39 Tri-State(Single Float) 40 Tri-State(Single Float) 41 Tri-State(Single Float) 42 Tri-State(Single Float) 43 Tri-State(Single Float) 44 Tri-State(Single Float) 45 Tri-State(Single Float) 46 Tri-State(Single Float) 47 Tri-State(Single Float) 48 Tri-State(Single Float) 49 Tri-State(Single Float) 50 Tri-State(Single Float) 51 Tri-State(Single Float) 52 Tri-State(Single Float) 53 Tri-State(Single Float) 54 Tri-State(Single Float) 55 Tri-State(Single Float) 56 Tri-State(Single Float) 57 Tri-State(Single Float) 58 Tri-State(Single Float) 59 Tri-State(Single Float) 60 Tri-State(Single Float) 61 Tri-State(Single Float) 62 Tri-State(Single Float) 63 Tri-State(Single Float) 64 Tri-State(Single Float) 65 Tri-State(Single Float) 66 Tri-State(Single Float) 67 Tri-State(Single Float) 68 Tri-State(Single Float) 69 Tri-State(Single Float) 70 Tri-State(Single Float) 71 Tri-State(Single Float) 72 Tri-State(Single Float) 73 Tri-State(Single Float) 74 Tri-State(Single Float) 75 Tri-State(Single Float) 76 Tri-State(Single Float) 77 Tri-State(Single Float) 78 Tri-State(Single Float) 79 Tri-State(Single Float) 80 Tri-State(Single Float) 81 Tri-State(Single Float) 82 Tri-State(Single Float) 83 Tri-State(Single Float) 84 Tri-State(Single Float) 85 Tri-State(Single Float) 86 Tri-State(Single Float) 87 Tri-State(Single Float) 88 Tri-State(Single Float) 89 Tri-State(Single Float) 90 Tri-State(Single Float) 91 Tri-State(Single Float) 92 Tri-State(Single Float) 93 Tri-State(Single Float) 94 Tri-State(Single Float) 95 Tri-State(Single Float) 96 Tri-State(Single Float) 97 Tri-State(Single Float) 98 Tri-State(Single Float) 99 Tri-State(Single Float) +AAM-