Loading...
HomeMy WebLinkAboutDAQ-2024-011330i I lr. 333 W Center Street . North Salt Lake Utah 84054 . 801.296.7700. www.bigwestoit.corn July 30,2024 CERTIFIED MAIL RETIIRN RECETPT NO. 9s89 0710 5270 1318 3714 38 Bryce Bird, Director Utah Division of Air Quality 195 North 1950 West P.O. Box 144820 Salt Lake ciry, uT 84114-4820 RE: 40 CFR 60 Subparts J and Ja, Dear Mr. Bird, 0'rnn orpnRTi\.4i r'JT oF DIVISION OF AiR Q1JAL ITY l't Semiannual Compliance Report of 2024 Attached is Big West Oil, LLC's (BWO) l't half of 2024 semi-annual report for 40 CFR 60 Subparts J and Ja, as required by 40 CFR 60. 107(c) and 60. l08a(d) for the refinery located in North Salt Lake, Utah. Equipment identified in this report is regulated by Utah Depaftment of Environmental Quality (UDEQ) Approval Order DAQE-AN101220081-24,dated May 6, 2024.This report addresses operations from January 1 through June 30, 2024, for the following sources: . All affbcted refinery flares, consisting of the South Flare and West Flare. These sources are subject to NSPS Subpart Ja in accordance with Utah PMro and PMz s State Implementation Plan (SIP) Sections IX.H.l .g.v.A and IX.H.1 1 .g.v.A, respectively.o The refinery fuel gas system is subject to NSPS Subpart Ja for HzS in accordance with Utah PMro and PMz s SIP Sections IX.H.l.g.ii.A and IX.H.l l.g.ii.A, respectively.. The Millisecond Catalyic Cracking Unit (MSCC) Regenerator is subject to NSPS Subpart J for all regulated pollutants (CO, SOz, and PM) per the 2013 BWO Consent Decree. Refinery Flares: The South and West Flares serve all process units in the refinery and are subject to 40 CFR 60 Subpart Ja. Each flare is subject to the following Work Practice Standards: r $60. 1 03a(h): 162 ppm HzS on a 3-hour rolling average;. S60.103a(c)(1Xi): 500 lb SO2 emitted from aflare in any24-hour period;o $60. l03a(cX l Xii): Discharge to a flare in excess of 500,000 scf above the baseline in any Z4-hour period. This report addresses the standards at $60.103a(c)(1)(i) and (ii). During the reporting period, there was one event that required the completion of a Root Cause Analysis and Corrective Actions Analysis per $60.103(c)(1)(i) or (ii). Details of any exceedances of the HzS 3-hour rolling average limit are included in the quarterly State Electronic Data Reports (SEDR) submitted to UDEQ for purposes of UAC R307- 170- 9 and are therefore not addressed in this report. Details of any exceedances of the emissions limits at 60.l02a(g)( I )(ii) are included in the quarterly SEDRs submitted to UDEQ for purposes of UAC R307- 170-9 and, therefore, are not addressed in this report. B-2-10122 Amine Unit/Refinery FuelGas System: BWO's Amine System/Refinery Fuel Gas System is subject to requirements within 40 CFR 60 Subpart Ja. In accordance with Utah PMz s SIP Section IX.H.1 l(g)(ii)(A), BWO shall comply with specified applicable requirements within 40 CFR 60 Subpart Ja for HzS content within refinery fuel gas. This includes the following limits (within 60.102) and work practice standards (within 60.103): $60.102a(g)(1)(ii): 162 ppmvd on a 3-hour rolling average basis; $60.102a(g)(1Xii): 60 ppmvd on a 365-day rolling average basis (same citation as 3-hour rolling average limit). $60.103a(c)(2): each exceedance of the 162 ppmvd HzS limit if the SO2 discharge to the atmosphere is 227 kg (500 lb) greater than the amount that would have been emitted if the emissions limits had been met during one or more consecutive periods of excess emissions or any 24-hour period, whichever is shorter. MSCC Regenerator: BWO operates a MSCC Regenerator, which is subject to 40 CFR 60 Subpart J for PM, CO, and SOz. The MSCC is subject to the following emissions limits and work practice standards:o $60.102(a)(1): 1.0 lb PM/1000-lb coke burn;o $60.102(a)(2): 30%o opacity on a six-minute average, except for one 6-minute reading per hour;o $60. I 03(a): 500 ppmvd CO on a one-hour average; . $60. l0a@)( I ): 50 ppmvd SOz on a 7 -day rolling average;o $60.104(d): A minimum of 22valid days of data shall be obtained per 30 rolling successive calendar days when complying with $60.104(bX1).o $60.105(a)( 13): Additional monitoring requirements if insufficient valid monitoring data is available for purposes of $60. 1 0 (d). This report addresses any deviations for the SOz limit at $60.104(b)( I ) and to the monitoring work practice standards at $60.104(d) and $60.105(a)(13). Evaluation for compliance with PM limit established in $60.102(a)(1) is determined via performance testing. This performance test was conducted on December 15,2023, and was included in the corresponding Consent Decree (CD) report submitted to UDEQ and EPA. Details of any exceedances of the limits at $60.102(a)(2), $60.103(a), and $60.104(b)(1) are included in quarterly SEDRs submitted to UDEQ for purposes of UAC R307-170-9 and are excluded from this report unless noted otherwise. Alignment with State Ouarterllz Reports: Monitoring system performance for all regulated continuous emission monitoring systems (CEMS) and continuous opacity monitoring systems (COMS) for the following sources and pollutants are reported per $60.7(c) and R307-170-9 as part of the SEDRs submitted to UDEQ:o South Flare (HzS, Total Reduced Sulfur);o West Flare (HzS, Total Reduced Sulfur);. MSCC Regenerator (SO2, CO, Oz, and Opacity);. Amine System/Refinery Fuel Gas System (H2S). These SEDR reports also address all CEMS and COMS downtime, cylinder gas audits (CGAs), and relative accuracy test audits (RATAs). BWO has submitted a report for the first quarter of 2024 and will submit the second quarter 2024 report on or before luly 30,2024. a a Certifi cation Statement: I certifo that this information was prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my directions and my inquiry of the person(s) who manage the system, or the person(s) directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief true, accurate, and complete. #rb Please call Brady Miller at (385) 324-1275 should any questions arise. Sincerely, Brady Miller Environmental Engineer CC: Director, Air and Toxics Technical Enforcement Program Office of Enforcement, Compliance and Environmental Justice MailCode 8ENF-AT 1595 Wynkoop Street Denver, CO 80202-1129 CERTIFIED MAIL RETURN RECETPT NO. 9s89 0710 5270 1318 371278 Alec Klinghoffer Refinery Manager Attachment One: 40 CFR 60 Subpart Ja: Summary Report 40 CFR 60 Subpart Ja Summary Report 40 CFR 60 Subpart Ja Flare RCA and CAA Summary per $$60.108a(d)(5) and (c)(6) Section l: Event Description and Release Information Complete Section I lor each 24-hcrur o€nod of'drsc Reoortins Element Resnonse Emission Source (flare)West Flare Description of flaring event 40 CFR 60.108a(cX6Xi) Butamer outage Incident Start Date 40 CFR 60. l08a(c)(6Xii 513U2024 Incident Staft Time (24-hour clock) 40 CFR 60. I 08a(c)(6)(ii 0l :00 Incident End Date 40 CFR 60.108a(cX6Xii) s13112024 Incident End Time (24-hour clock) 40 CFR 60. I 08a(cX6Xii 23:00 If Planned Startup/Shutdown, were Flare Management Plan (FMP) procedures followed? (YesAllo) (lf incident was due to a planned startup/shutdorvn and FMP procedures were followed, no Root Cause Analysis or Corrective Action description is necessary, do not complete Sections 2 and 3 of this report form.) 40 CFR 60. I 08a(c)(6Xxi) N/A - This was not a planned shutdown. If incident was not due to planned startup or shutdown, provide a brief explanation of event. 40 CFR 60.108a(c)(6)(xi) The Butamer stabilizer tower level was reading incorrectly, causing its relief valve to lift several times. Operations attempted to get the level to start working without success, which eventually led to the unit beine shut down. Cumulative quantity of gas discharged during this 24-hour period (scf), or if duration exceeds 24 hours, the quantity sent to flare for each 24-hour period. 40 CFR 60.108a(c)(6) and (6)(iii) 24,1'15,003 scf Was the cumulative quantity of gas discharged >500,000 scfover baseline during 24-hour period(s)? (Yes/Irtro) Primary South Flare Baseline - 323,000 scf/24-hr. RCA Trigger : 823,000 scf/24-hr Primary West Flare Baseline - 323,000 sc//24-hr RCA Trigger : 823,000 sc//24-hr See NSPS Ja FMP for Alt. Baselines. 40 CFR 60. I 08a(c)(6)&(6)(iii) Yes ; -i ri;,; i ;it.r',rr . .;'rl it r *Or'__ I J : "i {t.1, )'|:i.'}:i J7i.l (,llAL ll-YI 'r ------- - Iiil Ii:l:i Irlilr I t-.., -- ---- J ' i,t,.1,1,1 ;6rl Or Aili Olr/rl ITY 40 CFR 60 Subpart Ja Summary Report Renortins Element Resnonse Did SOz emissions exceed 500 lb during this 24-hour period? 40 CFR 60. 108a(c)(6)(iv) 40 CFR 60. l08a(cX6)(vii) No If yes: List cumulative quantity of SOz emissions during each24- hour period (lb, assuming99% sulfur conversion): 40 CFR 60. l08a(cX6Xvii) N/A - No exceedances during the reporting period AND List cumulative quantity of HzS emissions during each24- hour period (lb, assuming 1% uncombusted): 40 CFR 60. l08a(c)(6)(vii) N/A - No exceedances during the reporting period AND List total sulfur concentration (ppmvd) or HzS and estimated total sulfur in fuel during each 24-hour period that exceeded that threshold (ppmv/ppmv): 40 CFR 60. I 08a(cX6)(iv) N/A - No exceedances during the reporting period Describe steps taken to limit the emissions during the discharge 40 CFR 60. l08a(cX6Xviii) Operations followed the unit's SSM plan. Section 2: Root Cause Analysis - 40 CFR 60.108a(c)(6)(ix) Com Section 2 within 4 o nng evenl Reportins Element Response Description of root cause analysis The Butamer stabilizer tower level was reading incorrectly, causing its relief valve to lift several times. Operations attempted to get the level to start working without success, which eventually led to the unit beins shut down. Was cause same as that identified in a previous flaring incident? (YesA.lo) No Section 3: Corrective Action Analysis - 40 CFR 60.108a(c)(6)(x) Com Section 3 within 45 days ol t rng event Renortins Element Response Description of corrective action(s) completed within the 45 davs followins the discharse Replace level transmitter on stabilizer tower. For corrective action(s) not already completed, a description of proposed corrective action(s), a schedule for implementation, including proposed commencement and completion dates N/A - No further corrective actions are required. Attachment Two: 40 CFR 60 Subpart J: Summary Report 40 CFR 60 Subpart J Summary Report Section 1: Excess Emissions Event Description and Corrective Action - 40 CFR 60.107(c)(3) For each 7-day period during which an exceedance has occurred as defined in 40 CFR 60.1Oa(c)(1)(i) NOTE: Any exceedance that requires repofting in accordance with 40 CFR 60.107(3)(c)(i)-(iii) is reported in the State Electronic Data Reports as identified in the cover letter, but for clarification purposes is also identified here. Section 2: Reporting Requirements for SOz Continuous Emissions Monitoring Systems - 40 CFR 60.107(c)(a) i.e.. 50 pomv SOz tiom the MSCC Reqenerator on a 7-dav rollins averaqe basis Reportins Element Response The date that the exceedance occurred; 40 CFR 60.107(c)(3)(i) N/A - No exceedances during the reporting period. An explanation of the exceedance; 40 CFR 60.107(cX3Xii) N/A - No exceedances during the reporting period. Whether the exceedance was concurrent with a startup, shutdown, or malfunction of the fluid catalytic cracking unit or control system; and 40 CFR 60. I 07(c)(3Xiii) N/A - No exceedances during the reporting period. A description of the corrective action taken, if any. 40 CFR 60.107(cX3Xiv) N/A - No exceedances during the reporting period. ect to 40 CFR 60.104(b)( I e 50 v SOz from the MSCC Reoortine Element Resoonse/Aool icabilitv The dates for which and brief explanations as to why fewer than I 8 valid hours of data were obtained for the inlet continuous monitoring system; 40 CFR 60.107(c)(4)(i) Not applicable. BWO is subject to the 50 ppmv SOz limit and does not utilize an inlet continuous monitoring system. The dates for which and brief explanations as to why fewer than I 8 valid hours of data were obtained for the outlet continuous monitoring system; 40 CFR 60.107(cX4Xii) See submitted SEDRs as identified in the cover letter. Identification of times when hourly averages have been obtained based on manual sampling methods; 40 CFR 60.107(cX4Xiii) See submitted SEDRs as identified in the cover letter. Identification of the times when the pollutant concentration exceeded full span ofthe continuous monitoring system; and 40 CFR 60.107(cX4Xiv) See submitted SEDRs as identified in the cover letter. 40 CFR 60 Subpart J Summary Report Reportine Element Resoonse/Aonl icabi litv Description of any modifications to the continuous monitoring system that could affect the ability of the continuous monitoring system to comply with Performance Specifications 2or3. 40 CFR 60.107(cX4Xv) No modifications were made during the reporting period. Results of daily drift tests and quarterly accuracy assessments as required under appendix F, Procedure l. 40 CFR 60.107(cX4Xvi) See Attachment 3 for all daily drift checks completed during reporting period. Results of quarterly/annual accuracy assessments are included in the submitted SEDRs as identified in the cover letter. Section 3: Reporting Requirements for Sources Subject to Valid Data Requirement at 40 CFR 60.1 - 40 CFR 60.107(c &d Renortins Element Response Any 30-day period in which the minimum data requirements specified in $60.104(d) are not obtained. (i.e., any 30-day periods without 22valid days of data per 30 rolling successive calendar days period). 40 CFR 60. I 07(c)(2) No deviations from work practice standard during reporting period. Section 4: Evaluation of Changes to SOz Control System during CEMS Downtime- 40 CFR 60.r07(d Renortins Element Response For any periods for which sulfur oxides emissions data are not available, the owner or operator of the affected facility shall submit a signed statement indicating if any changes were made in operation of the emission control system during the period of data unavailability which could affect the ability of the system to meet the applicable emission limit. Operations of the control system and affected facility during periods of data unavailability are to be compared with operation of the control system and affected facility before and following the period of data unavailability. 40 cFR 60. I 07(d) No changes were made in operation of the emission control system during the periods of data unavailability identified within the State Electronic Data Reports submiued to UDEQ. See cover letter for certification. Attachment Three: Results of all daily Drift Checks completed during reporting period for MSCC Regenerator SOz CEMS MSCC Regenerator SO2 CEMS Daily Calibration Drift Check Results \nalvzer: AT-178C Date SO, Zero Time Zero Cylinder Value (PPM SOr) Zero Result (PPM SO2) Zeto Difference loA Errorl SO2 Span Timc Span Cylinder Value (PPM SOrl Span Result (PPM SO2) Span Difference l%Errorl 11112024 5:'18 AM 0.00 0.00 0.00o/o 5:23 AM 83.59 84.14 0.36% 1t2t2024 5:18 AM 0.00 0.00 0.00o/o 5:23 AM 83.59 83.95 0.24o/o 11312024 5:18 AM 0.00 0.00 0.00%5:23 AM 83.59 83.90 0.21o/o 114t2024 5:'18 AM 0.00 0.00 0.00%5:23 AM 83.5S 83.03 -0.37o/o 1t4t2024 8:16 AM 0.00 1.14 0.57%8:18 AM 83_59 82.55 -O.52o/o 115t2024 5:18 AM 0.00 0.00 0.00%5:23 AM 83.59 83.16 -o.29y. 1t6t2024 5:18 AM 0.00 0.00 0.00o/o 5:23 AM 83.59 84.08 0.33% 1nt2024 5:18 AM 0.00 0.00 0.00o/o 5:23 AM 83.59 83.29 -0.20y" 118t2024 5:18 AM 0.00 0.00 0.00%5:23 AM 83.5S 84.85 o.84% 1t9t2024 5:18 AM 0.00 0.00 0.00%5:23 AM 83.59 85.73 '|..430/, 1t10t2024 5:18 AM 0.00 0.99 0.66%5:22 AM 83.59 86.58 1.990/o 1t1112024 5: 18 AM 0.00 2.56 1 .71o/o 5:23 AM 83.59 B9.75 4.11% 1t11t2024 8:49 AM 0.00 0.00 0.00%8:55 AM 83.59 82.76 -O.41o/. 1t12t2024 5:18 AM 0.00 0.00 0.00%5:23 AM 83.59 84.24 0.43% 111312024 5:18 AM 0.00 0.00 0.00%5:23 AM 83.59 84.69 o.73% 111412024 5:18 AM 0.00 0.60 0.40o/o 5:23 AM 83.59 85.80 1.48o/o 1t15t2024 5:18 AM 0.00 0.60 0.40o/o 5:23 AM 83.59 85.07 0.990/o 1t16t2024 5: 18 AM 0.00 0.00 0.00o/o 5:23 AM 83.59 84.42 0.55% 111712024 5:18 AM 0.00 0.68 0.45%5:23 AM 83.59 85.81 1.48Yo 1t18t2024 5:18 AM 0.00 0.36 O.24Yo 5:23 AM 83.59 86.75 2.1Oo/" 1t19t2024 5:'18 AM 0.00 0.00 0.00%5:23 AM 83.59 82.95 -0.43% 1t20t2024 5:18 AM 0.00 0.00 0.00%5:23 AM 83.59 80.2S -2.20y" 112112024 5:18 AM 0.00 0.00 0.00%5:23 AM 83.59 81.56 1.35o/o 1122t2024 5:18 AM 0.00 0.00 0.00%5:23 AM 83.59 80.85 -1.8304 1t23t2024 5:18 AM 0.00 0.00 0.00%5:23 AM 83.59 80.28 -2.20y. 112412024 5: 18 AM 0.00 0.00 0.00%5:23 AM 83.59 77.85 -3.83% 1124t2024 2:16 PM 0.00 0.00 0.00olo 2:18 PM 83.59 42.87 -0.36% 'U25t2024 5:18 AM 0.00 0.00 0.00%5:23 AM 83.59 82.76 -0.55% 1t26t2024 5:18 AM 0.00 0.00 0.00%5:23 AM 83.s9 80.29 -2.2Oo/" 1127t2024 5:18 AM 0.00 0.00 0.00%5:23 AM 83.59 80.75 1.89% 1128t2024 5:18 AM 0.00 0.00 0.00%5:23 AM 83.5S 81.38 1.47% 1129t2024 5:8AM 0.00 0.00 0.00%5:23 AM 83.59 81 .51 1.39o/. '13012024 5:8AM 0.00 0.00 0.00%5:23 AM 83.59 80.83 1.84o/o 1t31t2024 5:8AM 0.00 0.00 0.00o/o 5:22 AM 83.59 80.58 -2.0Oo/o 2t1t2024 5:8AM 0.00 0.00 0.00o/o 5:22 AM 83.59 79.96 -2.42o/o 2t2t2024 5:BAM 0.00 0.00 0.00o/o 5:22 AM 83.59 80.08 -2.34Yo 21312024 5:8AM 0.00 0.00 0.00%5:22 AM 83.59 80.82 1.84Yo 21412024 5:18 AM 0.00 0.00 0.00%5:22 AM 83.59 80.85 1.83% 2t5t2024 5:18 AM 0.00 0.00 0.00%5:22 AM 83.5S 81.40 1.46% 2t612024 5:18 AM 0.00 0.00 0.00%5:22 AM 83.59 82.03 1.O4o/. 217t2024 5:18 AM 0.00 0.00 0.00%5:22 AM 83.59 83.03 -0.37o/o 2t812024 5:18 AM 0.00 0.00 0.00o/o 5:22 AM 83.sS 81.84 1.17Yo 2t8t2024 8:22 AM 0.00 0.41 O.21o/o B:24 AM 83.59 81.54 1.03yo 2t9t2024 5:18 AM 0.00 0.00 0.00%5:22 AM 83.59 83.26 -0.22% 2t10t2024 5:18 AM 0.00 0.00 0.00%5:22 AM 83.59 82.48 -O.744/" 2t1112024 5:18 AM 0.00 0.00 0.00%5:22 AM 83.59 83.58 -0.010h 2t12t2024 5:18 AM 0.00 1.29 0.86%5:22 AM 83.59 84.37 0.52o/o 211312024 5: 18 AM 0.00 2.52 1.680/o 5:22 AM 83.59 86.61 2.01o/o 2t14t2024 5:20 AM 0.00 3.69 2.460/o 5:22 AM 83.59 86.56 1.SB% 2115t2024 5:20 AM 0.00 6.96 4.640/o 5:23 AM 83.59 90.72 4.75% 2t16t2024 5:20 AM 0.00 0.00 0.00o/o 5:23 AM 86.10 85.98 -0.08% 2117t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 86.77 O.45o/o Page 1 of 4 \nalvzer: AT-178C Date SO2 Zero Time Zero Cylinder Value (PPM SOr) Zero Result (PPM SOr) Zero Difference l%Erorl iO, Span Time Span Cylinder Value (PPM SO,) Span Result (PPM SOr) Span Difference l% Errorl 2t18t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 86.17 0.05% 2t19t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 87.98 1.25o/o 2t20t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 87.23 0.75o/o 212112024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 86.64 0.36% 2t2212024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.1 0 85.49 -0.41y. 2t22t2024 8:21 AM 0.00 0.08 0.04o/o 8:24 AM 86.10 87.51 0.70o/o 2t23t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 82.69 -2.270/ 2t24t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 83.59 -'t.67% 212512024 5:20 AM 0_00 0.00 0.00%5:23 AM 86.10 83.48 -1-75o/. 2t26t2024 5:20 AM 0.00 0.00 0.00o/o 5:23 AM 86.'10 82.49 -2.410h 2t27t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 83.91 1.460/" 2128t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 84.05 1.360/o 212912024 5:20 AM 0.00 0.98 0.65%5:23 AM 86.10 85.'11 -0.66% 2t29t2024 8:49 AM 0.00 0.00 0.00%B:55 AM 86.10 81.40 -2.35% 3t112024 5:20 AM 0.00 0.00 0.00o/o 5:23 AM 86.10 83.04 -2.O40/o 3t2t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 82.21 -2.59Yo 3t3t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.'10 85.66 -0.30% 314t2024 5:20 AM 0.00 1.25 0.83%5:23 AM 86.'10 83.54 1.71o/" 31512024 5:20 AM 0.00 1.62 1.0804 5:23 AM 86.10 84.S3 -0.78o/o 316t2024 5:20 AM 0.00 3.00 2.O0o/o 5:23 AM 86.10 85.18 -0.610/o 3t7t2024 5:20 AM 0.00 3.30 2.20o/o 5:23 AM 86.10 86.54 0.30% 3t7t2024 7:46 AM 0.00 0.00 0.00%7:55 AM 86.10 82.45 -1.820/0 31812024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 82.40 -2.47o/" 3t9t2024 5:20 AM 0.00 0.00 0.00o/o 5:23 AM 86.'10 83.67 1.620/o 3t10t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 84.93 -O.78o/" 311112024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 83.45 1.77o/o 311212024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 87.22 o.75% 3t13t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 86.78 O.460/" 3t14t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 84.94 -0.77% 3t't5t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86 0 84.31 1.19o/" 3116t2024 5:20 AM 0.00 0.00 0.00o/o 5:23 AM 86.0 84.63 -0.98% 3t17t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.0 83.46 1.76% 311812024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.0 83.71 1.600/. 311912024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.0 84.55 1.03Yo 3t20t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.0 84.70 -0.940k 3t21t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.0 83.53 1 .71o/" 3t21t2024 8:50 AM 0.00 0.00 0.00o/o 8:52 AM 86.0 87.27 0.58% 312212024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.0 84.65 -O.97Y" 3t23t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.0 85.18 -0.61% 312412024 5:20 AM 0.00 0.00 0.00%5:23 AM 86 0 83.44 1.77yo 3t2st2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86 U 84.16 1.29o/o 3t26t2024 5:20 AM 0.00 0.00 0.00o/o 5:23 AM 86 0 83.25 1.90% 312712024 5:20 AM 0.00 0.00 0.00%5:23 AM 86 0 82.30 -2.54o/" 312812024 5:20 AM 0.00 0.00 0.00%5:23 AM 86 0 85.01 -O.73o/o 3129t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 84.38 -1.15o/o 3t30t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 83.84 '1.50% 3t31t2024 5:20 AM 0.00 0.00 0.00o/o 5:23 AM 86.'10 82.63 -232% 4t1t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 82.96 -2.10o/" 4t2t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 82.43 -2.44o/o 4t3t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.1 0 82.15 -2.630/0 41412024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.1 0 82.90 -2.13o/o 41412024 8:01 AM 0.00 0.00 0.00%8:03 AM 86.10 87.94 O.92o/o 4t5t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86. t0 85.44 -0.44o/^ 4t6t2024 5:20 AM 0.00 0.00 0.00o/o 5:23 AM 86.10 84.41 1.13% 4t7 t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 85.26 -0.56% Page 2 of 4 {nalvzer: AT-178C Date SO2 Zero Time Zero Cylinder Value (PPM SO,) Zero Result (PPM SOrl Zero Difference l%Errorl SO, Span Time Span Cylinder Value (PPM SOr) Span Result (PPM SO2) Span Difference l%Errorl 41812024 5:20 AM 0.00 0.22 O.15o/o 5:23 AM 86.10 86.36 O.17Yo 419t2024 5:20 AM 0.00 3.49 2.33Yo 5:23 AM 86.10 88.61 1.680/0 4t10t2024 5:20 AM 0.00 1.02 0.68%5:23 AM 86.10 87.37 0.85% 411112024 5:20 AM 0.00 3.48 2.32%5:23 AM 86.10 88.22 'l .410/o 411112024 7:59 AM 0.00 0.00 0.00%B:01 AM 86.10 84.25 -0.93% 4t12t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 86.30 0.13o/o 4t13t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.1 0 87.25 O.77o/o 411412024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 87.88 1.19o/o 411512024 5:20 AM 0.00 0.00 0.00o/o 5:23 AM 86.10 87.78 1 .12o/o 4116t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.'10 88.4S 1.60% 4t17t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.1 0 86.79 O.460/" 4118t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 84.S0 -0.80% 411812024 8:15 AM 0.00 1.23 o.61y"8:16 AM 86.10 86.'t6 0.03% 4t19t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 85.46 -0.42o/o 4120t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 86.33 0.16yo 412112024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 87.3s 0.83% 4t22t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 87.89 1.19o/o 4t23t2024 5:20 AM 0.00 0.00 0.00o/o 5:23 AM 86.10 85.13 -0.65% 412412024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 87.77 1.110/" 4125t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.1 0 84.'16 1.29% 4t25t2024 8:41 AM 0.00 0.00 0.00%B:43 AM 86.10 BB.O6 0.98% 412612024 5:20 AM 0.00 0.00 0.00o/o 5:23 AM 86.1 0 83.32 -1.85% 4t27t2024 5:20 AM 0.00 0.00 0.00%5:24 AM 86.10 83.39 1.81o/. 4128t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.'10 81.24 -3.240k 4t29t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86. t0 78.90 4.80% 4t29t2024 12:53 PM 0.00 0.00 0.00%1:02 PM 86.10 84.94 -0.580/. 413012024 5:20 AM 0.00 0.00 0.00%5:24 AM 86.0 84.70 -0.94Yo 5t1t2024 5:20 AM 0.00 0.00 0.00%5:24 AM 86.0 86.56 O.31o/" 51212024 5:20 AM 0.00 0.00 0.00%5:24 AM 86 0 86.53 O.28o/" 5t3t2024 5:20 AM 0.00 0.00 0.00%5:24 AM 86.0 88.03 1.29% 5t4t2024 5:20 AM 0.00 0.38 0.260/0 5:24 AM 86.10 89.43 2.22o/o 5t5t2024 5:20 AM 0.00 '1 .85 1.23o/o 5:23 AM 86.0 88.73 1 .760/o 51612024 5:20 AM 0.00 2.52 1.68%5:23 AM 86.0 89.47 2.24% 51712024 5:20 AM 0.00 2.O1 1.Uo/o 5:23 AM 86.1 0 91.42 3.54o/" 5t7t2024 10:29 AM 0.00 0.00 0.00o/o 10:39 AM 86.0 83.17 1.47% 5t8t2024 5:20 AM 0.00 0.00 0.00o/o 5:23 AM 86.10 84.71 -0.92o/o 5t9t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 86.29 0.13o/. 511012024 5:20 AM 0.00 0.00 o.00%5:23 AM 86 0 82.68 -2.28o/o 5t11t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86 0 84.64 -O.97o/" 511212024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 85.26 -0.56% 511312024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 83.8s 1.50o/o 5t14t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 84.67 -0.s5% 5115t2024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.10 84.',t6 1.29o/o 511612024 5:20 AM 0.00 0.00 0.00%5:23 AM 86.'10 82.81 -2.19o/" 5t17 t2024 5:20 AM 0.00 0.00 0.00o/o 5:23 AM 86.1 0 83.93 1.450/" 5t18t2024 5:'17 AM 0.00 0.00 0.00%5:24 AM 86.10 84.42 1.120 5t1912024 5:17 AM 0.00 0.00 0.00%5:24 AM 86.10 85.03 -0.72y. 512012024 5:17 AM 0.00 0.00 0.00%5:24 AM 86.10 85.66 -0.30o/o 512112024 5:17 AM 0.00 0.62 0.42Ya 5:24 AM 86 10 83.94 -1.44Yo 5t22t2024 5:17 AM 0.00 0.16 O.11o/o 5:24 AM 86.10 85.1 3 -0.640/0 5t23t2024 5:'17 AM 0.00 2.98 1.99%5:24 AM 86.10 86.53 0.28o/o 5t23t2024 8:10 AM 0.00 0.00 0.00%8:12 AM 86.10 83.62 -1.24o/o 5t24t2024 5:17 AM 0.00 0.00 0.00%5:24 AM 86.10 87.31 0.81o/o 512512024 5:17 AM 0.00 1.51 1.01o/o 5:24 AM 86.10 89.13 2.O2% 512612024 5:17 AM 0.00 3.12 2.O8o/"5:24 AM 86.10 88.51 1 .610/o Page 3 of 4 \nalvzer: AT-178C Date SO2 Zero Time Zero Cylinder Value (PPM SOrl Zero Result (PPM SOr) Zero Difference (%"Erorl iO2 Span Tim€ Span Cylinder Value (PPM SOr) Span Result (PPM SOr) Span Difference lY" Errorl 5t27t2024 5:17 AM 0.00 2.11 1.41o/.5:24 AM 86.10 89.45 2.23V. 5t28t2024 5:17 AM 0.00 1.56 1.04%5:24 AM 86.10 89.40 2.20o/o st29t2024 5:17 AM 0.00 1.31 O.87o/.5:24 AM 86.1 0 89.24 2.O9o/" 5t30t2024 5: 17 AM 0.00 1.17 o.780/o 5:24 AM 86.10 87.73 1.08% 5t31t2024 5: 17 AM 0.00 0.00 0 00%5:24 AM 86.10 83.05 -2.040 6t1t2024 5:17 AM 0.00 0.02 0.01o/o 5:24 AM 86.10 85.62 -0.32o/o 6t2t2024 5:17 AM 0.00 0.00 0.007o 5:24 AM 86.10 86.04 -0.04o/o 6t3t2024 5:17 AM 0.00 o.32 0.21yo 5:24 AM 86.10 84.85 -0.83% 6t412024 5:'17 AM 0.00 0.00 0.00%5:24 AM 86.10 84.32 1.19o/o 6t5t2024 5: 17 AM 0.00 0.00 0.00o/o 5:24 AM B6.10 83.57 1.69% 61612024 5:17 AM 0.00 0.00 0.00%5:24 AM 86.1 0 82.17 -2.62to 616t2024 1:44 PM 0.00 0.00 0.00%1:45 PM 84.96 82.53 1.21o/" 6t7t2024 5:17 AM 0.00 0.00 0.00%5:24 AM 84.S6 81.'t0 -2.58%o 6t7t2024 10:36 AM 0.00 0.00 0.00%10:40 AM 84.96 83.78 -0.59% 6t812024 5:17 AM 0.00 0.00 0.00%5:24 AM 84.96 81.66 -2.2oo/o 6t912024 5:17 AM 0.00 0.00 0.00o/o 5:24 AM 84.96 82.86 1.40% 6t10t2024 5:17 AM 0.00 0.00 0.00%5:24 AM 84.96 79.97 -3.337o 6t10t2024 10:47 AM 0.00 0.00 0.00%10:56 AM 84.96 82.00 1.48% 611112024 5:'17 AM 0.00 0.00 0.00%5:24 AM 84.96 81.67 -2.19o/o 6t12t2024 5:17 AM 0.00 0.00 0.00%5:24 AM 84.96 82.41 1.70o/o 6t13t2024 5:17 AM 0.00 0.00 0.00%5:24 AM 84.96 81.32 -2.43o/" 6t14t2024 5:17 AM 0.00 0.00 0.00%5:24 AM 84.96 85.38 0.28o/o 611512024 5:17 AM 0.00 0.00 0.00%5:24 AM 84.96 85.9'1 O.640/0 6t1612024 5:'17 AM 0.00 0.63 0.4204 5:24 AM 84.96 84.17 -0.520/ 6117t2024 5:17 AM 0.00 2.18 1.45yo 5:24 AM 84.96 90.10 3.42% 6t18t2024 5:17 AM 0.00 1.49 0.99%5:24 AM 84.96 89.76 3.200/0 6t18t2024 '11:10 AM 0.00 0.00 0.00%11:19 AM 84.96 83.82 -0.57o/o 6t19t2024 5:17 AM 0.00 0.00 0.00%5:24 AM 84.96 84.00 -0.640/o 612012024 5:17 AM 0.00 1 .18 0.79o/o 5:24 AM 84.96 86.07 0.74Yo 6t20t2024 9:13 AM 0.00 1.22 0.61%9:18 AM 84.96 84.58 -0.'l90lo 6t21t2024 5:17 AM 0.00 2.33 1 .55o/o 5:24 AM 84.96 84.47 -0.33o/o 6t2212024 5:7AM 0.00 1.13 0.75o/o 5:24 AM 84.96 86.00 0.69% 6t23t2024 5:7AM 0.00 1.55 1.03%5:24 AM 84.96 86.05 o.73% 6t24t2024 5:7AM 0.00 0.00 0.00o/o 5:24 AM 84.96 83.84 -o.740/ 6t2st2024 5:7AM 0.00 0.00 0.00%5:24 AM 84.96 85.00 0.03% 6t26t2024 5:7AM 0.00 0.00 0.00%5:24 AM 84.96 83.17 -1.2oo/o 6t27t2024 5:7AM 0.00 0.00 0.00%5:24 AM 84.96 81.37 -2.39% 6t28t2024 5:17 AM 0.00 0.00 0.00%5:24 AM 84.96 83.23 1j5% 6t29t2024 5:17 AM 0.00 0.00 0.00%5:24 AM 84.96 82.U 1.610 613012024 5:17 AM 0.00 0.00 0.00%5:24 AM 84.96 B3.5't -0.97o/o l- t.j rArt i-)Fl,n li, Ml' :i I OFg ,-rv r JrtLnti ,'Ml :.i r oF I tjNVtFtONl.lFlrllfit Qt tAt.iTY I t.- - ----l Itl::l Page 4 of 4 L____l t)t\/tst(-)N oF AIR Ol.lnt ITY l