Loading...
HomeMy WebLinkAboutDDW-2024-012781System Name: System Number:29034 1. Indoor Water Use Number of residential connections - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Number of other connections - - - 10 ERCs of other connections 2.0 Total Equivalent Residential Connections (ERCs)2.0 Per ERC Total Per ERC Total Per ERC Total (gpd/ERC) (gpm) (gallons/ERC) (gallons) (ac-ft/yr) (ac-ft/yr) 800 1.1 400 800 0.45 0.90 2. Outdoor Water Use Is the drinking water used for outdoor irrigation? Residential ERCs using drinking water for irrigation - - - - - - - - - - - - > > > Percentage of Residential ERCs using DW for irrigation - - - - - - - - - - - - > > >0%Map Zones Average irrigated acreage per residential connection - - - - - - - - - - - - > > >1 Total irrigated acreage of other connections.- - - - - - - - - - - - > > >2 Irrigation zone 3 3 4 5 6 Per ERC Total Per ERC Total Per ERC Total (gpd/ERC) (gpm) (gallons/ERC) (gallons) (ac-ft/yr) (ac-ft/yr) 0 0.0 0 0 0.00 0.00 3. Fire Flow Requirement Does the water system provide fire protection? Maximum fire suppression demand for water system or pressure zone (gpm)0 Maximum fire suppression duration for water system or pressure zone (hours)0 Required Fire Suppression Storage (gallons) - - - - - - - - - - - - - - - - - - - - > > >0 Total Water System Requirements (= indoor use + outdoor use + fire flow demand) Per ERC Total Per ERC Total Per ERC Total (gpd/ERC) (gpm) (gallons/ERC) (gallons) (ac-ft/yr) (ac-ft/yr) 800 1.1 400 800 0.45 0.90 Does this system have adequate source capacity per R309-510-7? IPS points may be assessed for lacking required source capacity to meet peak day and/or average yearly flow requirements. Existing Sources:0.0 gpm Required Source Capacity:1.1 gpm % of Req'd Capacity:0.0% Difference:-1 gpm (Example: water use of 2 factory is equivalent to 75 homes.) MINIMUM REQUIREMENTS FOR INDOOR WATER USE Storage Water Rights MINIMUM REQUIREMENTS FOR WATER SYSTEM Source System does not provide fire protection and lacks fire hydrants. MINIMUM REQUIREMENTS FOR OUTDOOR WATER USE Source Storage Water Rights Bluffs Campground Source Storage Water Rights Division of Drinking Water Water System Capacity Calculation Sheet (revised Aug 13, 2013) Enter the green cells only. No irrigation. Yes No Yes No Enter number of non-residential connections (e.g., 2 factory connections). Convert "Number of other connections" (Cell E9) to ERCs here. [ERCs of other connections = peak day demand of other connections / 800 gal per day] Enter estimated irrigated acre Enter total irrigated acres of other connections here. Enter fire flow in gpm. Enter duration in hours. Linked to Cell I99 below. Select Irrigated Zone # from the list. See "Irrigation Demands & Map" tab on the bottom of the screen. Negative number means (1) additional source capacity is needed , and (2) IPS points should be assessed. Linked to Cell C51 above. Bluffs Campground Capacity Calculations Page 1 of 2 10/30/2024 Does this system have adequate storage capacity per R309-510-8? IPS points may be assessed for lacking required storage capacity. Existing Storage:0 gal Required Storage Capacity:800 gal % of Req'd Capacity:0.0% Difference:-800 gal Non-community Water Systems - Calculation of ERCs for Indoor Water Use (*See R309-510, Tables 510-1, 2, & 4 for other facility types.) GPD/person*Calculated GPD/site or pad GPD/person Gallon/site or pad ERC/site or pad # of Sites or pads ERCs 60 480 30 240 0.60 0.0 20 160 10 80 0.20 0.0 5 40 2.5 20 0.05 0.0 N/A 100 N/A 50 0.13 0.0 *Number of people per camp site 8 Source (GPD/vehicle) Storage (Gal./vehicle) ERC/1000 vehicles served # of Vehicles served ERCs 7 3.5 8.75 0.00 Bluffs Campground Calcuation of Projected ERCs Source (in gallons per minute) Existing Residential Connections WS002 UTAH29007 Huntsville City Number of Obligated Future ERCs 0 Total Source Capacity 0 Max. ERC allowed (for indoor use only)0 Storage (in gallons) Total Projected Number of ERCs 0 Total Storage Capacity 0 Roadway Rest Stop w/ flushometer valves Semi-Developed Camp w/o flush toilets Semi-Developed Camp w/ flush toilets Camp hosts connect campers to water connections. All other connections are paddle spigots that recreators are not permitted to connect to. Calculated using 5 gpd per person for a population of 200 plus a few modern campsite pads for camp hosts. System is supplied water by Huntsville Town water system. It was unknown how much water is purchased or what the water main size that supplies the camp is, but even an unrealistically-sized water main would be capable of supplying much more than the source capacity requirement of this system. RV Park Facility Type Source MINIMUM REQUIREMENTS FOR INDOOR USE Modern Recreation Camp Storage Linked to Cell I118 below. If applicable, enter number of people per camp site here. Negative number means (1) additional storage volume is needed, and (2) IPS points should be assessed. If you need to calculate projected future demand & req'ts (including both existing & future residential connections), enter this number to Cell I8 as "Number of residential connection." Diaphragm or air pressure tanks shall not be considered effective storage volume for community systems or NTNC with significant demand. Linked to Cell E51 above. Bluffs Campground Capacity Calculations Page 2 of 2 10/30/2024