Loading...
HomeMy WebLinkAboutDERR-2024-011762 WESTECH EQUIPMENT -0307 801-266--433-801-261-4054 PRODUCT PIPING INTEGRITY TESTING Facility Name: Holy Cross Hospital Mountain Point Owner: Catholic Health Initiative CO dba Holy Cross Address: 3000 Triumph Boulevard Address: 1050 East South Temple City, State, Zip: Lehi, Utah 84043 City, State, Zip: Salt Lake City, Utah 84102 Facility I.D.#: 1000924 Phone #: 801-230-2977 Testing Company: Westech Phone #: 801-266-2545 Date:10/16/24 This procedure is to test the integrity of product piping. Tests were performed with Petro-Tite line tester. Tank Number 1 Product Stored Red DSL Piping Run Supply Piping Type D/W FRP Test Pressure (PSI)15 Test Duration (minutes)30 Leak Rate (GPH)0.002 Test Results Pass Fail Pass Fail Pass Fail Pass Fail Comments: Taber DeHart, UT-0394 WESTECH EQUIPMENT -0307 801-266--433-801-261-4054 AUTOMATIC TANK GAUGE OPERATION INSPECTION Facility Name: Holy Cross Hospital Mountain Point Owner: Catholic Health Initiative CO dba Holy Cross Address: 3000 Triumph Boulevard Address: 1050 East South Temple City, State, Zip: Lehi, Utah 84043 City, State, Zip: Salt Lake City, Utah 84102 Facility I.D.#: 1000924 Phone #: 801-230-2977 Testing Company: Westech Phone #: 801-266-2545 Date:10/16/24 This procedure is to determine whether the automatic tank gauge (ATG) is operating properly. See PEI/RP1200 Section 8.2 for the inspection procedure. This procedure is applicable to tank monitor stems the touch the bottom of the tank when in place. Tank Number 1 Product Stored Red DSL ATG Brand and Model TLS 350 1. Tank Volume, gallons 15,104 2. Tank Diameter, inches 119 5/8 3. After removing the ATG from the tank, it has been inspected and any damaged or missing parts replaced?Yes No Yes No Yes No Yes No 4. Float moves freely on the stem without binding?Yes No Yes No Yes No Yes No 5. Fuel float level agree with the value programmed into the console?Yes No Yes No Yes No Yes No 6. Water float level agree with the value programmed into the console?Yes No Yes No Yes No Yes No 7. Inch level from the bottom of the stem when 90% alarm is triggered?99 5/8 8. Inch level at which the overfill alarm activates corresponds with the value programmed in the gauge? Yes No Yes No Yes No Yes No 9. Inch level from the bottom when the water float first triggers an alarm?1 10. Inch level at which the water float alarm activates corresponds with the value programmed in the gauge? Yes No Yes No Yes No Yes No If any answers in Lines 3, 4, 5, or 6 are "No" the system has failed the test. Test Results Pass Fail Pass Fail Pass Fail Pass Fail Comments: Battery OK Name Taber DeHart, UT-0394 WESTECH EQUIPMENT -0307 801-266--433-801-261-4054 OVERFILL ALARM OPERATION INSPECTION Facility Name: Holy Cross Hospital Mountain Point Owner: Catholic Health Initiative CO dba Holy Cross Address: 3000 Triumph Boulevard Address: 1050 East South Temple City, State, Zip: Lehi, Utah 84043 City, State, Zip: Salt Lake City, Utah 84102 Facility I.D.#: 1000924 Phone #: 801-230-2977 Testing Company: Westech Phone #: 801-266-2545 Date:10/16/24 This procedure is to determine whether the automatic tank gauge (ATG) is operating properly. See PEI/RP1200 Section 8.2 for the inspection procedure. This procedure is applicable to tank monitor stems the touch the bottom of the tank when in place. Tank Number 1 Product Stored Red DSL ATG Brand and Model TLS 350 1. Tank Volume, gallons 15,104 2. Tank Diameter, inches 119 5/8 3. Overfill alarm activates in the test mode at the console?Yes No Yes No Yes No Yes No 4. When activated, overfill alarm can be heard or seen while delivering to the tank?Yes No Yes No Yes No Yes No 5. After removing the probe from the tank, it has been inspected and any damaged or missing parts replaced?Yes No Yes No Yes No Yes No 6. Float moves freely on stem without binding?Yes No Yes No Yes No Yes No 7. Moving product level float up the stem trigger alarm?Yes No Yes No Yes No Yes No 8. Inch level from bottom of stem when 90% alarm is triggered?99 5/8 9. Tank volume at inch level in Line 8.13,581 10. Calculate (Line 9 / Line 1) X 100 89.92 11. Is line 10 less than 90%?Yes No Yes No Yes No Yes No 12. Fuel float level on the console agrees with the gauge stick reading?Yes No Yes No Yes No Yes No 13. Overfill alarm activates at any product level above 90% tank capacity?Yes No Yes No Yes No Yes No Test Results Pass Fail Pass Fail Pass Fail Pass Fail Comments: Taber DeHart, UT-0394