DAQC-1064-24
Site ID 10237 (B5)
MEMORANDUM
TO: FILE – PACIFICORP – Hunter Power Plant
THROUGH: Harold Burge, Major Source Compliance Section Manager
FROM: Rob Leishman, Environmental Scientist
DATE: October 17, 2024
SUBJECT: PacifiCorp Hunter Power Plant (Hunter), Major, NSPS, Emery County,
FRS # UT0000004901500101
INSPECTION TYPE: State Electronic Data Report (SEDR) Review
REVIEW DATE: October 17, 2024
SOURCE LOCATION: Castle Dale/Emery County
SOURCE CONTACT: Terry Guthrie – 435-748-6059
Jay Howard – 435-748-6519
APPLICABLE
REGULATIONS: Title V Operating Permit
PERMIT NUMBER: 1500101004
DATE OF PERMIT: September 4, 2020
Date of Last Revision: November 19, 2021
SOURCE REVIEW EVALUATION:
SOURCE INSPECTION
EVALUATION: With the exception of sources that only monitor for opacity, quarterly
report memoranda will only address the findings of the quarterly
report. Approval Order and Title V permit conditions addressing
continuous emission monitoring requirements will be addressed in
Hunter’s relative accuracy performance specification test review
memorandum.
SEDR Review:
Third Quarter 2024
% Monitor Availability (MA) Performance Test Dates
(N/A to Opacity)
Summary of Excess Emissions During Point
Source Operation
Point
Source
Op.
hrs. Channel MA CGA Lin RATA Point
Source Channel Hrs. Limitation
1 2208 SO2 99% 08/19/24 10/19/23 1 SO2 0.00 1.2 lb/MMBtu - 3
hr ra
1 2208 NOx 97% 08/19/24 10/19/23 1 SO2 0.00 0.12 lb/MMBtu -
30 DRA
1 8 2
2
Third Quarter 2024
% Monitor Availability (MA) Performance Test Dates
(N/A to Opacity)
Summary of Excess Emissions During Point
Source Operation
Point
Source
Op.
hrs. Channel MA CGA Lin RATA Point
Source Channel Hrs. Limitation
1 2208 CO2 99% 08/19/24 10/19/23 1 SO2 0.00 0.2 lb/MMBtu -
30 DRA
1 2208 Opacity 99% 1 NOx 0.00 0.7 lb/MMBtu - 3
hr ra
1 2208 CO 97% 08/19/24 10/19/23 1 NOx 0.00 0.26 lb/MMBtu -
30 DRA
2 2207 SO2 100% 08/20/24 05/02/24 1 Opacity 0.00 20 Percent - 6 min
2 2207 NOx 99% 08/20/24 05/02/24 1 CO 0.00 3990 lb/hr - 8 hr
Block Ave
2 2207 CO2 100% 08/20/24 05/02/24 1 CO 0.00 0.34 lb/MMBtu -
30 DRA
2 2207 Opacity 99% 2 SO2 0.00 1.2 lb/MMBtu - 3
hr ra
2 2207 CO 100% 08/20/24 05/02/24 2 SO2 0.00 0.12 lb/MMBtu -
30 DRA
3 2079 SO2 99% 08/26/24 10/25/23 2 SO2 0.00 0.2 lb/MMBtu -
30 DRA
3 2079 NOx 97% 08/26/24 10/25/23 2 NOx 0.00 0.7 lb/MMBtu - 3
hr ra
3 2079 CO2 99% 08/26/24 10/25/23 2 NOx 0.00 0.26 lb/MMBtu -
30 DRA
3 2079 Opacity 99% 2 Opacity 0.00 20 Percent - 6 min
3 2079 CO 99% 08/26/24 10/25/23 2 CO 0.00 3990 lb/hr - 8 hr
Block Ave
2 CO 0.00 0.34 lb/MMBtu -
30 DRA
3 SO2 0.00 0.12 lb/MMBtu -
30 DRA
3 SO2 0.00 0.2 lb/MMBtu -
30 DRA
3 NOx 0.00 0.34 lb/MMBtu -
30 DRA
3 Opacity 0.00 20 Percent - 6 min
3 CO 0.00 0.2 lb/MMBtu -
30 DRA
3 CO 0.00 2406 lb/hr - 8 hr
Block Ave
Summary of SO2 Emission Reduction
Percent Removal Required
% Reduction
Point
Source Channel Min Max Days in violation Status
1 SO2 94% 95% 80% 0 In compliance
2 SO2 94% 96% 80% 0 In compliance
3 SO2 94% 95% 90% 0 In compliance
3
Excess Emission Report - Hourly Summary
Point
Source Channel
Startup
&
Shutdown
Control
Equipment
Problems
Process
Problems
Other
Known
Causes
Unknown
Causes
Emission
Limit
1 SO2 0 0 0 0 0 1.2 lb/MMBtu - 3 hr ra
1 SO2 0 0 0 0 0 0.12 lb/MMBtu - 30 DRA
1 SO2 0 0 0 0 0 0.2 lb/MMBtu - 30 DRA
1 NOx 0 0 0 0 0 0.7 lb/MMBtu - 3 hr ra
1 NOx 0 0 0 0 0 0.26 lb/MMBtu - 30 DRA
1 Opacity 0 0 0 0 0 20 Percent - 6 min
1 CO 0 0 0 0 0 3990 lb/hr - 8 hr Block Ave
1 CO 0 0 0 0 0 0.34 lb/MMBtu - 30 DRA
2 SO2 0 0 0 0 0 1.2 lb/MMBtu - 3 hr ra
2 SO2 0 0 0 0 0 0.12 lb/MMBtu - 30 DRA
2 SO2 0 0 0 0 0 0.2 lb/MMBtu - 30 DRA
2 NOx 0 0 0 0 0 0.7 lb/MMBtu - 3 hr ra
2 NOx 0 0 0 0 0 0.26 lb/MMBtu - 30 DRA
2 Opacity 0 0 0 0 0 20 Percent - 6 min
2 CO 0 0 0 0 0 3990 lb/hr - 8 hr Block Ave
2 CO 0 0 0 0 0 0.34 lb/MMBtu - 30 DRA
3 SO2 0 0 0 0 0 0.12 lb/MMBtu - 30 DRA
3 SO2 0 0 0 0 0 0.2 lb/MMBtu - 30 DRA
3 NOx 0 0 0 0 0 0.34 lb/MMBtu - 30 DRA
3 Opacity 0 0 0 0 0 20 Percent - 6 min
3 CO 0 0 0 0 0 0.2 lb/MMBtu - 30 DRA
3 CO 0 0 0 0 0 2406 lb/hr - 8 hr Block Ave
CMS Performance Summary - Hourly Summary
Point
Source Channel Monitor
Malfunction
Non-monitor
Malfunction
QA
Calibrations
Other
Known
Causes
Unknown
Causes
1 SO2 0 0 5 18 0
1 NOx 46 0 9 13 0
1 CO2 0 0 5 18 0
1 Opacity 1 0 11 1 0
1 CO 24 0 15 25 0
2 SO2 0 0 5 2 0
2 NOx 9 0 2 2 0
2 CO2 0 0 2 2 0
2 Opacity 2 0 10 2 0
4
CMS Performance Summary - Hourly Summary
Point
Source Channel Monitor
Malfunction
Non-monitor
Malfunction
QA
Calibrations
Other
Known
Causes
Unknown
Causes
2 CO 0 0 2 2 0
3 SO2 0 0 1 10 0
3 NOx 57 0 1 1 0
3 CO2 0 0 1 10 0
3 Opacity 0 0 10 3 0
3 CO 0 0 1 10 0
Type Code 280 (COMS Attenuator Filters) Procedure 3
Point Source
& Location
Attenuator
I.D.
Attenuator
Certification
Date
Certified
Attenuator
Opacity
OPLR,
SECR,
or
PLCF,
Corrected
Opacity
Value
Range
Low,
Mid, &
High
Certification
1-year or
5-year
Unit 1 - 1A S13263 6/28/24 17.40 1.00 17.4 Low 1
Unit 1 - 1A S13268 6/28/24 26.60 1.00 26.6 Mid 1
Unit 1 - 1A S13249 6/28/24 46.90 1.00 46.9 High 1
Unit 1 - 1B S13263 6/28/24 17.40 1.00 17.4 Low 1
Unit 1 - 1B S13268 6/28/24 26.60 1.00 26.6 Mid 1
Unit 1 - 1B S13249 6/28/24 46.90 1.00 46.9 High 1
Unit 2 - 2A S13263 6/28/24 17.40 1.00 17.4 Low 1
Unit 2 - 2A S13268 6/28/24 26.60 1.00 26.6 Mid 1
Unit 2 - 2A S13249 6/28/24 46.90 1.00 46.9 High 1
Unit 2 - 2B S13263 6/28/24 17.40 1.00 17.4 Low 1
Unit 2 - 2B S13268 6/28/24 26.60 1.00 26.6 Mid 1
Unit 2 - 2B S13249 6/28/24 46.90 1.00 46.9 High 1
Unit 3 - 3 S13263 6/28/24 17.40 1.00 17.4 Low 1
Unit 3 - 3 S13268 6/28/24 26.60 1.00 26.6 Mid 1
Unit 3 - 3 S13249 6/28/24 46.90 1.00 46.9 High 1
Unit 3 - 3 S13263 6/28/24 17.40 1.00 17.4 Low 1
Unit 3 - 3 S13268 6/28/24 26.60 1.00 26.6 Mid 1
Unit 3 - 3 S13249 6/28/24 46.90 1.00 46.9 High 1
Type Code 281 (Procedure 3 - COMS Filter Audit Calibration Error)
Point
Source Location Audit Date
Opacity Monitor Response
(Average of 5) Mean Difference Calibration
Error (≤ 3%) Low Mid High
Unit 1 1A 7/15/24 18 -0.320 0.005
Unit 1 1A 7/15/24 26 -0.660 0.011
5
Type Code 281 (Procedure 3 - COMS Filter Audit Calibration Error)
Point
Source Location Audit Date
Opacity Monitor Response
(Average of 5) Mean Difference Calibration
Error (≤ 3%) Low Mid High
Unit 1 1A 7/15/24 48 0.780 0.011
Unit 1 1B 7/15/24 17 -0.100 0.009
Unit 1 1B 7/15/24 27 -0.130 0.018
Unit 1 1B 7/15/24 47 -0.160 0.013
Unit 2 2A 7/16/24 17 -0.150 0.008
Unit 2 2A 7/16/24 25 -0.940 0.010
Unit 2 2A 7/16/24 47 0.400 0.004
Unit 2 2B 7/16/24 18 0.910 0.012
Unit 2 2B 7/16/24 27 -0.130 0.004
Unit 2 2B 7/16/24 48 1.120 0.025
Unit 3 3 7/22/24 17 -0.050 0.001
Unit 3 3 7/22/24 27 0.140 0.012
Unit 3 3 7/22/24 48 0.980 0.010
Unit 3 3 7/22/24 17 -0.630 0.009
Unit 3 3 7/22/24 25 -1.240 0.017
Unit 3 3 7/22/24 48 0.630 0.008
Type Code 282 (Annual Zero Alignment Audit) Procedure 3
Point
Source Location Audit
Date
Alternative Zero
Alignment
(Yes or No)
COM Clear
Condition
Zero Response
(CCZR)
COM
Simulated
Zero
Response
(CSZR)
Zero
Alignment
Error
Difference
(CCZR)-
(CSZR)
Adjustment to
COM
Simulated Zero
Response
(CSZR)
(Yes or No)
1 1A 2/12/24 no 0.25 0.03 0 yes
1 1B 2/12/24 no -2.35 -0.03 -2 yes
2 2A 2/6/24 no 100.00 -0.02 100 yes
2 2B 2/6/24 no 0.83 -0.15 1 yes
3 3A 3/6/24 no 0.49 0.04 0 yes
3 3B 3/5/24 no 0.35 -0.07 0 yes
Summary of SO2 Emission Reduction
Percent Removal Required Percent
Reduction
Point
Source Channel Min Max Days in violation
1 SO2 94% 95% 80% 0
2 SO2 94% 96% 80% 0
3 SO2 94% 95% 90% 0
6
Pollutant Concentration
Exceeded Span of CEM
Monitor Outage During
Point Source Operation
Alternate
Sampling CEM Modifications
0 Hours 333 Hours 0 Hours 0 Events
SOURCE INSPECTION
SUMMARY EVALUATION: PacifiCorp Hunter Power Plant maintains its CEMS as required in
R307-170 and 40 CFR 60.13.
CURRENT
RECOMMENDATIONS: All deviations appear to be a result of breakdown or process related
problems that do not warrant issuing a violation. Periods of excess
emissions that were recorded by the CMS in service on each point
source during this reporting period are summarized in the SEDR and
described in Pivot Table 400 “Excess Emissions Review.” Hunter
Power Plant was in compliance during this reporting period. No
further enforcement actions should be taken. Hunter’s NSPS
monitoring system meets the performance standards of 40 CFR 60,
Appendix B Performance Specifications. Hunter’s acid rain
monitoring system meets the performance standards of 40 CFR 75
Acid Rain Performance Specifications.
HIGH PRIORITY
VIOLATOR (HPV): No
RECOMMENDATION
FOR NEXT INSPECTION: Check DAS for daily zero and span drift.
Check the QC program to ensure that monitor drift is being tracked
and that the source can identify excessive drift.
ATTACHMENTS: Excel spreadsheet review
Pacificorp Hunter EER 3Q2024
Point Source Information Late Expired Cal. Gas Valid Cal. Gas Days Yes No
1 Type Code 100
(Company Information)Type Code Company Manager Company Name AIRS # Phone Number
Environmental
Contact
1 100 Laren Huntsman 01500101 435-748-6519 Jay Howard
1 100 0 0 0 0
1 Type Code 110
(Point Source Identification)Type Code Point Source
Quarter
1 - 4 Year
Point Source
Operating Hrs. in
Quarter
1 110 3 2024 2208
1 110 3 2024 2207.98
1 110 3 2024 2079.75
1 110 0 0 0
1 Type Code 200
(Monitor Identification)Type Code Point Source Channel Manufacturer Model No. Monitor SN Low Span High Span Installation Date
Monitor
Location
1 200 CO Thermo Scientific 48iQ 12111711815 0 2000 7/12/2021 Stack
1 200 CO2 Thermo Scientific 410iQ 12111711827 0 20 7/12/2021 Stack
1 200 NOx Thermo Scientific 42iQ 12111711830 0 400 7/12/2021 Stack
1 200 OpacityA Teledyne Lighthawk 560 ES 5603357 0 100 9/17/2021 1-1 BH
1 200 OpacityB Teledyne Lighthawk 560 ES 5603356 0 100 9/17/2021 1-2 BH
1 200 SO2 Thermo Scientific 43iQ 12111711833 60 600 7/12/2021 Stack
1 200 CO Thermo Scientific 48iQ 12111711816 0 2000 7/13/2021 Stack
1 200 CO2 Thermo Scientific 410iQ 12111711828 0 20 7/13/2021 Stack
1 200 NOx Thermo Scientific 42iQ 12111711831 0 400 7/13/2021 Stack
1 200 OpacityA Teledyne Lighthawk 560 ES 5603359 0 100 9/16/2021 2-1 BH
1 200 OpacityB Teledyne Lighthawk 560 ES 5603358 0 100 9/16/2021 2-2 BH
1 200 SO2 Thermo Scientific 43iQ 12111711834 60 600 7/12/2022 Stack
1 200 CO Thermo Scientific 48iQ 12111711817 0 2000 7/13/2021 Stack
1 200 CO2 Thermo Scientific 410iQ 12111711829 0 20 7/13/2021 Stack
1 200 NOx Thermo Scientific 42iQ 12111711832 0 400 7/13/2021 Stack
1 200 OpacityA Teledyne Lighthawk 560 ES 5603360 0 100 9/15/2021 3-1 BH Duct
1 200 OpacityB Teledyne Lighthawk 560 ES 5603361 0 100 9/15/2021 3-2 BH Duct
1 200 SO2 Thermo Scientific 43iQ 12111711835 60 600 7/13/2021 Stack
1 200 0 0 0 0 0 0 1/0/1900 0
1
Type Code310
(Excess Emissions)
SUMMARY REPORT
Type Code Channel
Total Hours of Excess
Emissions
Excess Emissions -
% of Total
Operating Hours
RC 701 Hours -
start
up/Shutdown
RC 702 Hours-
Control Equipment
Problems
RC 703 Hours -
Process Problems
RC 704, 706, 707
Hours -Other Known
Causes
RC 705 Hours -
Unknown
Causes
Emission
Limitation
Emission
Limitation
Units
Emission
Limitation
Averaging
Period
1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 1.2 lb/MMBtu 3 hr ra
1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 0.12 lb/MMBtu 30 DRA
1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 0.2 lb/MMBtu 30 DRA
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 0.7 lb/MMBtu 3 hr ra
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 0.26 lb/MMBtu 30 DRA
1 TRUE 310 Opacity 0 0.00% 0 0 0 0 0 20 Percent 6 min
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 3990 lb/hr 8 hr Block Ave
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 0.34 lb/MMBtu 30 DRA
1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 1.2 lb/MMBtu 3 hr ra
1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 0.12 lb/MMBtu 30 DRA
1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 0.2 lb/MMBtu 30 DRA
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 0.7 lb/MMBtu 3 hr ra
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 0.26 lb/MMBtu 30 DRA
1 TRUE 310 Opacity 0 0.00% 0 0 0 0 0 20 Percent 6 min
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 3990 lb/hr 8 hr Block Ave
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 0.34 lb/MMBtu 30 DRA
1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 0.12 lb/MMBtu 30 DRA
1 TRUE 310 SO2 0 0.00% 0 0 0 0 0 0.2 lb/MMBtu 30 DRA
1 TRUE 310 NOx 0 0.00% 0 0 0 0 0 0.34 lb/MMBtu 30 DRA
1 TRUE 310 Opacity 0 0.00% 0 0 0 0 0 20 Percent 6 min
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 0.2 lb/MMBtu 30 DRA
1 TRUE 310 CO 0 0.00% 0 0 0 0 0 2406 lb/hr 8 hr Block Ave
1 310 0 0 0 0 0 0 0 0 0
Point Source
0
3
1
2
3
0
3
1
1
1
2
2
2
3
3
3
3
Pacificorp Hunter
0
1
1
1
1
1
1
2
2
2
2
2
1
1
1
2
2
1
1
2
2
2
2
3
3
3
3
3
3
0
Pacificorp Hunter EER 3Q2024
1 Type Code 300 (CMS
Performance Summary) Type Code Channel
Point Source Operating
Hours
Downtime - % of
Total Operating
Hours
Total CMS
Downtime
RC 721 Hours -
Monitor
Malfunction
RC 722 Hours -
Non-monitor
Malfunction
RC 723 Hours -
QA Calibrations
RC 724 Hours -
Other Known
Causes
RC 725
Hours -
Unknown
Causes
1 TRUE 300 SO2 2208 1.03% 22.82 0 0 4.97 17.85 0
1 TRUE 300 NOx 2208 3.06% 67.67 45.82 0 8.93 12.92 0
1 TRUE 300 CO2 2208 1.03% 22.82 0 0 4.97 17.85 0
1 TRUE 300 Opacity 2208 0.56% 12.36 0.97 0 10.87 0.52 0
1 TRUE 300 CO 2208 2.89% 63.77 23.92 0 14.95 24.9 0
1 TRUE 300 SO2 2207.98 0.31% 6.91 0 0 4.93 1.98 0
1 TRUE 300 NOx 2207.98 0.59% 12.93 8.97 0 1.98 1.98 0
1 TRUE 300 CO2 2207.98 0.18% 3.96 0 0 1.98 1.98 0
1 TRUE 300 Opacity 2207.98 0.63% 14 1.77 0 9.88 2.35 0
1 TRUE 300 CO 2207.98 0.18% 3.96 0 0 1.98 1.98 0
1 TRUE 300 SO2 2079.75 0.52% 10.91 0 0 0.98 9.93 0
1 TRUE 300 NOx 2079.75 2.82% 58.74 56.78 0 0.98 0.98 0
1 TRUE 300 CO2 2079.75 0.52% 10.91 0 0 0.98 9.93 0
1 TRUE 300 Opacity 2079.75 0.61% 12.71 0.08 0 10.05 2.58 0
1 TRUE 300 CO 2079.75 0.52% 10.91 0 0 0.98 9.93 0
1 300 0 0 0 0 0 0
1 Type Code 250
(Performance Specification
RATA Results)
Type Code Channel
Date of Most Current
RATA
Date of Preceding
RATA
Months Between
RATA's
Units of
Measurement CEM Value Reference Method
Value
Relative
accuracy Pass/ Fail
1 273 Days 250 CO 10/19/23 01/19/23 9 lb/mmBtu 0.2 0.2 10.90% pass
1 273 Days 250 CO 10/19/23 01/19/23 9 lb/hr 852.5 802.9 10.50% pass
1 273 Days 250 CO2 10/19/23 01/19/23 9 Percent 11.1 11.4 3.20% pass
1 273 Days 250 NOx 10/19/23 01/19/23 9 #/MMBtu 0.2 0.2 2.40% pass
1 273 Days 250 SO2 10/19/23 01/19/23 9 ppm 30.8 29.2 7.80% pass
1 261 Days 250 CO 05/02/24 08/15/23 8.6 lb/mmBtu 0.19 0.17 15.00% pass
1 261 Days 250 CO 05/02/24 08/15/23 8.6 lb/hr 546.8 496.1 14.40% pass
1 261 Days 250 CO2 05/02/24 08/15/23 8.6 Percent 10.7 10.6 1.80% pass
1 261 Days 250 NOx 05/02/24 08/15/23 8.6 #/MMBtu 0.1 0.1 0.40% pass
1 261 Days 250 SO2 05/02/24 08/15/23 8.6 ppm 34.6 35.4 2.70% pass
1 281 Days 250 CO 10/25/23 01/17/23 9.2 lb/mmBtu 0.1 0.1 11.80% pass
1 281 Days 250 CO 10/25/23 01/17/23 9.2 lb/hr 253.4 239.4 11.70% pass
1 281 Days 250 CO2 10/25/23 01/17/23 9.2 Percent 11.9 12.1 2.80% pass
1 281 Days 250 NOx 10/25/23 01/17/23 9.2 #/MMBtu 0.3 0.3 4.10% pass
1 281 Days 250 SO2 10/25/23 01/17/23 9.2 ppm 37.3 34.7 9.30% pass
1 0 Days 250 0 01/00/00 01/00/00 0 0 0 0 0.00% 0
1 Type Code 260
(CGA Results)Type Code Channel Date Audit Point No. Cylinder ID
Cylinder
Expiration Date
Type of
Certification
Units of
Measurement CEM Value Cylinder
Value
Precision
%Pass/ Fail Range - High or
Low
1 Valid Cal. Gas 260 CO 08/19/24 low CC16317 08/23/27 p1 ppm 496 516 -3.90% PASS 0
1 Valid Cal. Gas 260 CO 08/19/24 mid DT0027442 12/20/27 p1 ppm 1120.6 1118 0.20% PASS 0
1 Valid Cal. Gas 260 CO 08/20/24 low CC116787 07/06/28 p1 ppm 539.5 527 2.40% PASS 0
1 Valid Cal. Gas 260 CO 08/20/24 mid DT0019999 10/25/27 p1 ppm 1143 1135 0.70% PASS 0
1 Valid Cal. Gas 260 CO 08/26/24 low SA7143 08/23/27 p1 ppm 536.9 520 3.30% PASS 0
1 Valid Cal. Gas 260 CO 08/26/24 mid CC325166 10/25/27 p1 ppm 1146.4 1136 0.90% PASS 0
1 260 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0
Point Source
Point Source
Point Source
0
2
2
2
2
3
1
1
1
1
2
2
2
1
1
1
3
2
2
3
3
3
3
0
1
1
1
1
2
1
3
3
3
3
2
2
3
3
0
Pacificorp Hunter EER 3Q2024
1 Type Code 270
(Linearity Test Results)Type Code Channel Date Audit Point No. Cylinder ID
Cylinder
Expiration Date
Type of
Certification
Units of
Measurement CEM Value Cylinder
Value
Precision
%Pass/ Fail Range - High or
Low
1 Valid Cal. Gas 270 CO2 08/19/24 low CC16317 08/23/27 P1 percent 4.9 4.9 0.00% PASS 0
1 Valid Cal. Gas 270 CO2 08/19/24 mid CC142441 09/22/31 P1 percent 10.93 10.9 0.30% PASS 0
1 Valid Cal. Gas 270 CO2 08/19/24 high CC150885 11/15/30 P1 percent 18.27 18.1 0.90% PASS 0
1 Valid Cal. Gas 270 NOx 08/19/24 low CC16317 08/23/27 P1 ppm 109.77 109.2 1% PASS 0
1 Valid Cal. Gas 270 NOx 08/19/24 mid CC142441 09/22/31 P1 ppm 222.63 223 0% PASS 0
1 Valid Cal. Gas 270 NOx 08/19/24 high CC150885 11/15/30 P1 ppm 344.17 351 2% PASS 0
1 Valid Cal. Gas 270 SO2 08/19/24 low CC16317 08/23/27 P1 ppm 148.13 145.9 1.50% PASS 0
1 Valid Cal. Gas 270 SO2 08/19/24 mid CC142441 09/22/31 P1 ppm 327.03 329.5 0.70% PASS 0
1 Valid Cal. Gas 270 SO2 08/19/24 high CC150885 11/15/24 P1 ppm 511.57 531 3.70% PASS 0
1 Valid Cal. Gas 270 CO2 08/20/24 low CC116787 07/06/28 P1 percent 4.9 5 2.00% PASS 0
1 Valid Cal. Gas 270 CO2 08/20/24 mid CC230556 09/22/31 P1 percent 10.9 10.9 0.00% PASS 0
1 Valid Cal. Gas 270 CO2 08/20/24 high CC179361 08/26/27 P1 percent 17.83 17.7 0.80% PASS 0
1 Valid Cal. Gas 270 NOx 08/20/24 low CC116787 07/06/28 P1 ppm 111.6 110.4 1.10% PASS 0
1 Valid Cal. Gas 270 NOx 08/20/24 mid CC230556 09/22/31 P1 ppm 220.87 220 0.40% PASS 0
1 Valid Cal. Gas 270 NOx 08/20/24 high CC179361 08/26/27 P1 ppm 352.73 357 1.20% PASS 0
1 Valid Cal. Gas 270 SO2 08/20/24 low CC116787 07/06/28 P1 ppm 154.1 146.8 5% PASS 0
1 Valid Cal. Gas 270 SO2 08/20/24 mid CC230556 09/22/31 P1 ppm 332.3 328.9 1% PASS 0
1 Valid Cal. Gas 270 SO2 08/20/24 high CC179361 08/26/27 P1 ppm 519.9 532 2% PASS 0
1 Valid Cal. Gas 270 CO2 08/26/24 low SA7143 08/23/27 P1 percent 4.97 4.9 1.40% PASS 0
1 Valid Cal. Gas 270 CO2 08/26/24 mid CC318664 02/28/32 P1 percent 10.8 10.8 0.00% PASS 0
1 Valid Cal. Gas 270 CO2 08/26/24 high CC155742 08/26/27 P1 percent 17.63 17.6 0.20% PASS 0
1 Valid Cal. Gas 270 NOx 08/26/24 low SA7143 08/23/27 P1 ppm 113.9 110 3.50% PASS 0
1 Valid Cal. Gas 270 NOx 08/26/24 mid CC318664 02/28/32 P1 ppm 224.57 223 0.70% PASS 0
1 Valid Cal. Gas 270 NOx 08/26/24 high CC155742 08/26/27 P1 ppm 357.23 358 0.20% PASS 0
1 Valid Cal. Gas 270 SO2 08/26/24 low SA7143 08/23/27 P1 ppm 150.8 146.2 3.10% PASS 0
1 Valid Cal. Gas 270 SO2 08/26/24 mid CC318664 02/28/32 P1 ppm 321 320.6 0.10% PASS 0
1 Valid Cal. Gas 270 SO2 08/26/24 high CC155742 08/26/27 P1 ppm 531.4 539 1.40% PASS 0
1 270 0 01/00/00 0 0 01/00/00 0 0 0 0 0.00% 0 0
1
Type Code 210
(Pollutant Concentration
Exceeded Span of CEM)
Type Code Channel Start Date Start Time End Date End Time Hours
1 0 0 0 1/0/00 0:00 1/0/00 0:00
1
1 None Reported
1 0 TC 220 Hours 333.13 TC 220 Hours 0.00 TC 230 Hours 0.00 Events 0.00 Hours 0.00 Events 0.00 0.00
1 335.38 TC 300 Hours 2.25 FALSE
None Reported None Reported Yes Yes None Reported None Reported
2
2
2
3
3
3
3
3
3
3
0
Point Source
Point Source
Yes
Type Code 550
(Changes in Operation in
Control Equipment When
CEM Data Not Available)
Type Code 500
(Boiler Operating Days
w/o 18 Hours of Data)
Type Code 450
(Data Excluded)
Type Code 210
(Pollutant Concentration
Exceeded Span of CEM)
Type Code 220
(Monitor Outage
During Point Source Operation)
Type Code 230
(Manual Sample - Alternate
Sampling During Monitor
Outage)
Type Code 240
(CEM Modifications)
Type Code 530
(Excess Emissions During
Emergency Conditions)
2
3
3
1
1
1
1
2
1
1
1
1
1
2
2
2
2
0
Pacificorp Hunter EER 3Q2024
Relative Accuracy Overview
Point Source Channel
Date of Most
Current
RATA
Date of
Preceding
RATA
Months Between
RATA's
Units
Measured CEM Value Reference Method
Value
Relative
Accuracy Pass/ Fail 2024
1 CO 10/19/23 01/19/23 9 lb/mmBtu 0.2 0.20 10.90% pass
1 CO 10/19/23 01/19/23 9 lb/hr 852.5 802.90 10.50% pass
1 CO2 10/19/23 01/19/23 9 Percent 11.1 11.40 3.20% pass
1 NOx 10/19/23 01/19/23 9 #/MMBtu 0.2 0.20 2.40% pass
1 SO2 10/19/23 01/19/23 9 ppm 30.8 29.20 7.80% pass
2 CO 05/02/24 08/15/23 8.6 lb/mmBtu 0.19 0.17 15.00% pass
2 CO 05/02/24 08/15/23 8.6 lb/hr 546.8 496.10 14.40% pass
2 CO2 05/02/24 08/15/23 8.6 Percent 10.7 10.60 1.80% pass
2 NOx 05/02/24 08/15/23 8.6 #/MMBtu 0.1 0.10 0.40% pass
2 SO2 05/02/24 08/15/23 8.6 ppm 34.6 35.40 2.70% pass
3 CO 10/25/23 01/17/23 9.2 lb/mmBtu 0.1 0.10 11.80% pass
3 CO 10/25/23 01/17/23 9.2 lb/hr 253.4 239.40 11.70% pass
3 CO2 10/25/23 01/17/23 9.2 Percent 11.9 12.10 2.80% pass
3 NOx 10/25/23 01/17/23 9.2 #/MMBtu 0.3 0.30 4.10% pass
3 SO2 10/25/23 01/17/23 9.2 ppm 37.3 34.70 9.30% pass
*
NSPS CGA Third 2024
Audit Gas Ranges Audit Gas Ranges
AP1 Low AP2 Low AP1 High AP2 High
1 CO 8/19/24 2000 516 400 to 600
1 CO 8/19/24 2000 1118 1000 to 1200
2 CO 8/20/24 2000 527 400 to 600
2 CO 8/20/24 2000 1135 1000 to 1200
3 CO 8/26/24 2000 520 400 to 600
3 CO 8/26/24 2000 1136 1000 to 1200
*
Acid Rain Audit Linearity Third 2024
Low Span Gas Ranges High Span Gas Ranges
Low Mid High Low Mid High
1 CO2 8/19/24 20 4.9 4 to 6
1 CO2 8/19/24 20 10.9 10 to 12
1 CO2 8/19/24 20 18.1 16 to 20
1 NOx 8/19/24 400 109.2 80 to 120
1 NOx 8/19/24 400 223 200 to 240
1 NOx 8/19/24 400 351 320 to 400
1 SO2 8/19/24 600 145.9 120 to 180
1 SO2 8/19/24 600 329.5 300 to 360
1 SO2 8/19/24 600 531 480 to 600
2 CO2 8/20/24 20 5 4 to 6
2 CO2 8/20/24 20 10.9 10 to 12
2 CO2 8/20/24 20 17.7 16 to 20
2 NOx 8/20/24 400 110.4 80 to 120
2 NOx 8/20/24 400 220 200 to 240
2 NOx 8/20/24 400 357 320 to 400
2 SO2 8/20/24 600 146.8 120 to 180
2 SO2 8/20/24 600 328.9 300 to 360
2 SO2 8/20/24 600 532 480 to 600
3 CO2 8/26/24 20 4.9 4 to 6
3 CO2 8/26/24 20 10.8 10 to 12
3 CO2 8/26/24 20 17.6 16 to 20
3 NOx 8/26/24 400 110 80 to 120
3 NOx 8/26/24 400 223 200 to 240
3 NOx 8/26/24 400 358 320 to 400
3 SO2 8/26/24 600 146.2 120 to 180
3 SO2 8/26/24 600 320.6 300 to 360
3 SO2 8/26/24 600 539 480 to 600
*
Audit Gas Used
Point Source Channel Audit Date Low Span
Point Source Channel Audit Date Low Span
Audit Gas Used High Span Audit Gas Used
High SpanAudit Gas Used
Pacificorp Hunter EER 3Q2024
Type Code 280 (COMS Attenuator Filters) Procedure 3
Point Source Location
Attenuator
I.D.
Attenuator
Certification Date
Certified Attenuator
Opacity
OPLR,
SECR, or
PLCF,
Corrected Opacity
Value
Range
Low, Mid, & High
Certification
1-year or 5-year
Unit 1 1A S13263 6/28/24 17 1 17.4 Low 1
Unit 1 1A S13268 6/28/24 27 1 26.6 Mid 1
Unit 1 1A S13249 6/28/24 47 1 46.9 High 1
Unit 1 1B S13263 6/28/24 17.4 1 17.4 Low 1
Unit 1 1B S13268 6/28/24 26.6 1 26.6 Mid 1
Unit 1 1B S13249 6/28/24 46.9 1 46.9 High 1
Unit 2 2A S13263 6/28/24 17.4 1 17.4 Low 1
Unit 2 2A S13268 6/28/24 26.6 1 26.6 Mid 1
Unit 2 2A S13249 6/28/24 46.9 1 46.9 High 1
Unit 2 2B S13263 6/28/24 17.4 1 17.4 Low 1
Unit 2 2B S13268 6/28/24 26.6 1 26.6 Mid 1
Unit 2 2B S13249 6/28/24 46.9 1 46.9 High 1
Unit 3 3 S13263 6/28/24 17.4 1 17.4 Low 1
Unit 3 3 S13268 6/28/24 26.6 1 26.6 Mid 1
Unit 3 3 S13249 6/28/24 46.9 1 46.9 High 1
Unit 3 3 S13263 6/28/24 17.4 1 17.4 Low 1
Unit 3 3 S13268 6/28/24 26.6 1 26.6 Mid 1
Unit 3 3 S13249 6/28/24 46.9 1 46.9 High 1
*
Opacity Monitor Response (Average of 5)
Low Range Mid Range High Range
Unit 1 1A 7/15/24 18 -0.320 0.110 0.136 0.005
Unit 1 1A 7/15/24 26 -0.660 0.358 0.444 0.011
Unit 1 1A 7/15/24 48 0.780 0.224 0.278 0.011
Unit 1 1B 7/15/24 17 -0.100 0.649 0.806 0.009
Unit 1 1B 7/15/24 27 -0.130 1.350 1.676 0.018
Unit 1 1B 7/15/24 47 -0.160 0.940 1.167 0.013
Unit 2 2A 7/16/24 17 -0.150 0.502 0.623 0.008
Unit 2 2A 7/16/24 25 -0.940 0.042 0.052 0.010
Unit 2 2A 7/16/24 47 0.400 0.000 0.000 0.004
Unit 2 2B 7/16/24 18 0.910 0.230 0.286 0.012
Unit 2 2B 7/16/24 27 -0.130 0.230 0.286 0.004
Unit 2 2B 7/16/24 48 1.120 1.085 1.347 0.025
Unit 3 3 7/22/24 17 -0.050 0.050 0.062 0.001
Unit 3 3 7/22/24 27 0.140 0.839 1.042 0.012
Unit 3 3 7/22/24 48 0.980 0.000 0.000 0.010
Unit 3 3 7/22/24 17 -0.630 0.179 0.222 0.009
Unit 3 3 7/22/24 25 -1.240 0.377 0.468 0.017
Unit 3 3 7/22/24 48 0.630 0.132 0.164 0.008
*
Point Source Location Audit Date
Alternitive Zero
Alignment
(Yes or No)
COM Clear
Condition Zero
Response
(CCZR)
COM Simulated
Zero Response
(CSZR)
Zero Alignment
Error Difference
(CCZR)-(CSZR)
Adjustment to COM
Simulated Zero
Response
(CSZR)
(Yes or No)
1 1A 2/12/24 no 0.250 0.030 0.220 yes
1 1B 2/12/24 no -2.350 -0.030 -2.320 yes
2 2A 2/6/24 no 100.000 -0.020 100.020 yes
2 2B 2/6/24 no 0.830 -0.150 0.980 yes
3 3A 3/6/24 no 0.490 0.040 0.450 yes
3 3B 3/5/24 no 0.350 -0.070 0.420 yes
Type Code 282 (Procedure 3 - Annual Zero Alignment Audit)
Point
Source Location Audit Date Mean Difference Standard Deviation
Confidence
Coefficient
Calibration
Error (≤ 3%)
Type Code 281 (Procedure 3 - COMS Filter Audit Calibration Error)
Pacificorp Hunter EER 3Q2024
Monitoring Information TC 210, 230, & 240
Type Code 210
(Pollutant Concentration Exceeded Span of CEM) - 500 (All)
*
Sum of Hours Column Labels
Row Labels (blank) Grand Total
(blank)0 0
Grand Total 0 0
*
Type Code 230
(Manual Sample - Alternate Sampling During Monitor Outage) - 500 (All)
*
Sum of Hours Column Labels
Row Labels (blank) Grand Total
(blank)0 0
Grand Total 0 0
*
Type Code 240
(CEM Modifications) - 100 (All)
*
Count of Channel Column Labels
Row Labels (blank) Grand Total
(blank)
(blank)
Grand Total
Pacificorp Hunter EER 3Q2024
Type Code 220
(Monitor Outage During Point Source Operation) - 600 (All)
*
Sum of Hours Column Labels
Row Labels 723 724 721 Grand Total
1
Opacity
The monitor was unavailable during the daily monitor calibration as
required by 40 CFR parts 60 and 75.7.50 7.50
Bad input status for all or part of averaging period, resulted in invalid
averaging period.0.08 0.08
Opacity monitor optical surfaces were cleaned and inspected. Stack sets
were conducted followed by an autocalibration. The monitor was then
returned to service.
0.65 0.65
Quarterly filter audit performed followed by auto calibration.2.72 2.72
Maintenance of another monitor required normal sampling to be
interrupted. The system was returned to service following the
maintenance.
0.27 0.27
The ERP on the Opcity monitor display was not functionig data was still
good. Display was changed out 0.97 0.97
Power was loss to stack due to a problem with a load center or load
center problem trouble shooting. The power was restored and the PLC
recycled and comm restored between stack and DAHS.
0.08 0.08
Maintenance was inadvertanly hit. Monitor was taken out of
maintenance no work was done on the monitors.0.08 0.08
CO2
Maintenance of another monitor required normal sampling to be
interrupted. The system was returned to service following the
maintenance.
17.85 17.85
Quarterly linearity testing performed.1.98 1.98
Performing scheduled annual maintenance, checks and inspections.
Inspected or replaced sample pump, light source, critical orifices.
Followed by auto calibration and abbreviated linearity test.
2.98 2.98
CO
Maintenance of another monitor required normal sampling to be
interrupted. The system was returned to service following the
maintenance.
24.90 24.90
The NOx, CO wheel chopper motor failed. The motor was replaced and
the monitor was returned to service.13.97 13.97
Failure of a monitor light source resulted in invalid data. The light source
was replaced followed by a manual calibration, auto calibration, and an
abbreviated linearity test.
2.98 2.98
8864 froze up causing bad data. Power was cycled and data started to
record. Initiated autocalibration.1.98 1.98
An abbreviated lineraity test was initiated following monitor
maintenance or to check system accuracy.9.98 9.98
Quarterly linearity testing performed.1.98 1.98
Performing scheduled annual maintenance, checks and inspections.
Inspected or replaced sample pump, light source, critical orifices.
Followed by auto calibration and abbreviated linearity test.
2.98 2.98
IR source on the analyzer failed. Source was replaced followed by an
auto cal.4.98 4.98
NOx
Pacificorp Hunter EER 3Q2024
Sum of Hours Column Labels
Row Labels 723 724 721 Grand Total
Maintenance of another monitor required normal sampling to be
interrupted. The system was returned to service following the
maintenance.
12.92 12.92
8864 froze up causing bad data. Power was cycled and data started to
record. Initiated autocalibration.4.98 4.98
NOx ozinator transformer was arching causing the monitor to go into
alarm. Transformer was replaced. Followed by an auto cal.0.98 0.98
The CEMS monitor readings locked up. The monitor was reset (powered
down and then powered backup) followed by an auto calibration.
11.93 11.93
The monitor high voltage power supply or processor board failed
resulting in invalid data. A new power supply or processor board was
installed, out put voltages adjusted and the monitor was recalibrated
and returned to service.
27.92 27.92
Quarterly linearity testing performed.5.95 5.95
Performing scheduled annual maintenance, checks and inspections.
Inspected or replaced sample pump, light source, critical orifices.
Followed by auto calibration and abbreviated linearity test.
2.98 2.98
SO2
Maintenance of another monitor required normal sampling to be
interrupted. The system was returned to service following the
maintenance.
17.85 17.85
Quarterly linearity testing performed.1.98 1.98
Performing scheduled annual maintenance, checks and inspections.
Inspected or replaced sample pump, light source, critical orifices.
Followed by auto calibration and abbreviated linearity test.
2.98 2.98
2
Opacity
The monitor was unavailable during the daily monitor calibration as
required by 40 CFR parts 60 and 75.7.25 7.25
Opacity monitor optical surfaces were cleaned and inspected. Stack sets
were conducted followed by an autocalibration. The monitor was then
returned to service.
0.18 0.18
Quarterly filter audit performed followed by auto calibration.0.17 0.17
Power was loss to stack due to a problem with a load center or load
center problem trouble shooting. The power was restored and the PLC
recycled and comm restored between stack and DAHS.
0.08 0.08
Trouble shooting 8864 turned off 8864 and then turned back on and
cleared the alarms.1.47 1.47
#N/A 0.47 0.47
Temporary loss of power to monitor resulted in loss of data. Power was
restored and monitor returned to service.0.17 0.17
The monitor exhibited excessive drift. System components were
inspected and or replace board level cal was performed on system boards
followed by man and auto cal.
1.77 1.77
Invalid 6 minute due to process off time and/ or calibration during hour 0.17 0.17
CO2
Performing scheduled annual maintenance, checks and inspections.
Inspected or replaced sample pump, light source, critical orifices.
Followed by auto calibration and abbreviated linearity test.
1.98 1.98
Pacificorp Hunter EER 3Q2024
Sum of Hours Column Labels
Row Labels 723 724 721 Grand Total
Trouble shooting 8864 turned off 8864 and then turned back on and
cleared the alarms.1.98 1.98
CO
Performing scheduled annual maintenance, checks and inspections.
Inspected or replaced sample pump, light source, critical orifices.
Followed by auto calibration and abbreviated linearity test.
1.98 1.98
Trouble shooting 8864 turned off 8864 and then turned back on and
cleared the alarms.1.98 1.98
NOx
Performing scheduled annual maintenance, checks and inspections.
Inspected or replaced sample pump, light source, critical orifices.
Followed by auto calibration and abbreviated linearity test.
1.98 1.98
Trouble shooting 8864 turned off 8864 and then turned back on and
cleared the alarms.1.98 1.98
Opacity monitor was intermittently showing missing and invalid data.
Diagnostic actions were taken to find the cause of the spikes and missing
data. Auto cal was completed following diagnostic work.
8.97 8.97
SO2
Performing scheduled annual maintenance, checks and inspections.
Inspected or replaced sample pump, light source, critical orifices.
Followed by auto calibration and abbreviated linearity test.
1.98 1.98
Daily Cal of the monitor was in the maintenance limit.2.95 2.95
Trouble shooting 8864 turned off 8864 and then turned back on and
cleared the alarms.1.98 1.98
3
Opacity
The monitor was unavailable during the daily monitor calibration as
required by 40 CFR parts 60 and 75.6.75 6.75
Bad input status for all or part of averaging period, resulted in invalid
averaging period.0.08 0.08
Opacity monitor optical surfaces were cleaned and inspected. Stack sets
were conducted followed by an autocalibration. The monitor was then
returned to service.
0.57 0.57
Quarterly filter audit performed followed by auto calibration.2.47 2.47
The monitor high voltage power supply or processor board failed
resulting in invalid data. A new power supply or processor board was
installed, out put voltages adjusted and the monitor was recalibrated
and returned to service.
0.08 0.08
#N/A 0.18 0.18
Invalid 6 minute due to process off time and/ or calibration during hour 1.28 1.28
Rodded probe, cleaned or replaced ceramic filter, followed by auto
calibration. No adjustments made to analyzers.0.08 0.08
Opacity monitor retro reflector lenses were cleaned and inspected. No
adjustments were made to the analyzer. Followed by an auto cal.
1.13 1.13
Startup Calibration 0.08 0.08
CO2
Maintenance of another monitor required normal sampling to be
interrupted. The system was returned to service following the
maintenance.
8.95 8.95
Pacificorp Hunter EER 3Q2024
Sum of Hours Column Labels
Row Labels 723 724 721 Grand Total
Performing scheduled annual maintenance, checks and inspections.
Inspected or replaced sample pump, light source, critical orifices.
Followed by auto calibration and abbreviated linearity test.
0.98 0.98
Rodded probe, cleaned or replaced ceramic filter, followed by auto
calibration. No adjustments made to analyzers.0.98 0.98
CO
Maintenance of another monitor required normal sampling to be
interrupted. The system was returned to service following the
maintenance.
8.95 8.95
Performing scheduled annual maintenance, checks and inspections.
Inspected or replaced sample pump, light source, critical orifices.
Followed by auto calibration and abbreviated linearity test.
0.98 0.98
Rodded probe, cleaned or replaced ceramic filter, followed by auto
calibration. No adjustments made to analyzers.0.98 0.98
NOx
8864 froze up causing bad data. Power was cycled and data started to
record. Initiated autocalibration.32.90 32.90
The monitor high voltage power supply or processor board failed
resulting in invalid data. A new power supply or processor board was
installed, out put voltages adjusted and the monitor was recalibrated
and returned to service.
6.98 6.98
Performing scheduled annual maintenance, checks and inspections.
Inspected or replaced sample pump, light source, critical orifices.
Followed by auto calibration and abbreviated linearity test.
0.98 0.98
Rodded probe, cleaned or replaced ceramic filter, followed by auto
calibration. No adjustments made to analyzers.0.98 0.98
The monitor failed its daily/startup calibration. The monitor was
recalibrated and returned to service.16.90 16.90
SO2
Maintenance of another monitor required normal sampling to be
interrupted. The system was returned to service following the
maintenance.
8.95 8.95
Performing scheduled annual maintenance, checks and inspections.
Inspected or replaced sample pump, light source, critical orifices.
Followed by auto calibration and abbreviated linearity test.
0.98 0.98
Rodded probe, cleaned or replaced ceramic filter, followed by auto
calibration. No adjustments made to analyzers.0.98 0.98
Grand Total 77.15 117.68 138.30 333.13
Pacificorp Hunter EER 3Q2024
Opy *
Opy Count of Magnitude of Emissions Column Labels
Opy Row Labels Grand Total
Opy Grand Total
SO2 *
SO2 Type Code 410 (SO2) - 6000 (All)
SO2 *
SO2 Count of Magnitude of Emissions Column Labels
SO2 Row Labels Grand Total
SO2 Grand Total
NOx d *
NOx d Type Code 421 (Daily NOx Emissions) - 500 (All)
NOx d *
NOx d Count of Reason Code Column Labels
NOx d Row Labels y Grand Total
NOx d 3
NOx d #N/A 2 2
NOx d Grand Total 2 2
CO *
CO Type Code 440
(CO) - 6000 (All)
CO *
CO Count of Magnitude of Emissions Column Labels
CO Row Labels Grand Total
CO Grand Total
Dat Ex *
Dat Ex Type Code 450
(Data Excluded) - 6000 (All)
Dat Ex *
Dat Ex Count of Channel Column Labels
Dat Ex Row Labels 724 721 723 Grand Total
Dat Ex 3
Dat Ex CO 4 1 5
Dat Ex Rodded probe, cleaned or replaced ceramic filter, followed by
auto calibration. No adjustments made to analyzers.1 1
Dat Ex
Maintenance of another monitor required normal sampling to be
interrupted. The system was returned to service following the
maintenance.
3 3
Dat Ex
Performing scheduled annual maintenance, checks and
inspections. Inspected or replaced sample pump, light source,
critical orifices. Followed by auto calibration and abbreviated
linearity test.
1 1
Dat Ex NOx 1 13 1 15
Dat Ex Rodded probe, cleaned or replaced ceramic filter, followed by
auto calibration. No adjustments made to analyzers.1 1
Dat Ex The monitor failed its daily/startup calibration. The monitor was
recalibrated and returned to service.6 6
Dat Ex
The monitor high voltage power supply or processor board failed
resulting in invalid data. A new power supply or processor board
was installed, out put voltages adjusted and the monitor was
recalibrated and returned to service.
1 1
Dat Ex 8864 froze up causing bad data. Power was cycled and data
started to record. Initiated autocalibration.6 6
Dat Ex
Performing scheduled annual maintenance, checks and
inspections. Inspected or replaced sample pump, light source,
critical orifices. Followed by auto calibration and abbreviated
linearity test.
1 1
Dat Ex SO2 4 1 5
Dat Ex Rodded probe, cleaned or replaced ceramic filter, followed by
auto calibration. No adjustments made to analyzers.1 1
Dat Ex
Maintenance of another monitor required normal sampling to be
interrupted. The system was returned to service following the
maintenance.
3 3
Dat Ex
Performing scheduled annual maintenance, checks and
inspections. Inspected or replaced sample pump, light source,
critical orifices. Followed by auto calibration and abbreviated
linearity test.
1 1
Dat Ex Grand Total 9 13 3 25
Pacificorp Hunter EER 3Q2024
Pacificorp Hunter EER 3Q2024
Type Code 500
Before February 28, 2005 (Boiler Operating Days w/o 18 Hours of
Data) After February 28, 2005 (90% Operating Hours For each 30 BOD)
- 500
(All)
*
Count of Channel Column Labels
Row Labels 701 Grand Total
3
SO2 6 6
The unit was removed from service in a controlled fashion in order
to repair a boiler tube leak. The tube leak was repaired and the
unit was returned to service.
2 2
The unit was removed from service in a controlled manner in
order to repair a feedwater heater. The heater was repaired and
the unit returned to service.
3 3
The unit was removed from service in a controlled manner in
order to repair a turbine control valve. The valve was repaired and
the unit retruned to service.
1 1
NOx 6 6
The unit was removed from service in a controlled fashion in order
to repair a boiler tube leak. The tube leak was repaired and the
unit was returned to service.
2 2
The unit was removed from service in a controlled manner in
order to repair a feedwater heater. The heater was repaired and
the unit returned to service.
3 3
The unit was removed from service in a controlled manner in
order to repair a turbine control valve. The valve was repaired and
the unit retruned to service.
1 1
Grand Total 12 12
*
Type Code 510
(F-factor, Equations & Conversion Factors) - 500 (All)
Count of F-factor Column Labels
Row Labels SO2 NOx Grand Total
1
1800 1 1 2
2
1800 1 1 2
3
1800 1 1 2
Grand Total 3 3 6
*
Type Code 520
(Minimum Data Not
Obtained <22/30 BODs) - 500
(All)
Count of Channel Column Labels
Row Labels Grand Total
Grand Total
*
Type Code 530
(Excess Emissions During Emergency Conditions) - 500 (All)
Count of Date Column Labels
Row Labels Grand Total
Grand Total
*
Type Code 540
(Fuel Pre-treatment Credit SO2) - 500 (All)
Count of Date Column Labels
Row Labels Grand TotalGrand Total
*
TypeCode 550
(Changes in Operation in Control Equipment When CEM Data Not
Available) - 500
(All)
Column Labels
Row Labels Grand Total
Grand Total