Loading...
HomeMy WebLinkAboutDAQ-2024-0112061 DAQC-PBR158140001-24 Site ID 15814 (B1) MEMORANDUM TO: FILE – FINLEY RESOURCES INC. – UTE 16-11A-4-1 THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Manager FROM: Fred Goodrich, Environmental Scientist DATE: October 21, 2024 SUBJECT: OIL AND GAS PERMIT-BY-RULE EVALUATION INSPECTION DATE: September 19, 2024 SOURCE LOCATION: Lat: 40.131801 Long: -109.891348 Business Office: Finley Resources Inc. 1308 Lake Street Fort Worth, TX 76102 SOURCE TYPE: Tank Battery Uintah API: 4304752666 SOURCE CONTACTS: Aimee Cole, Local Contact Phone: 720-384-7365, Email: acole@finleyresources.com OPERATING STATUS: Operating. PROCESS DESCRIPTION: Oil and gas products are brought to the surface. These products go through a separator where the oil and any water products are sent to storage tanks and the gas is used to power equipment on site (pump jack engine, tank heater, separator, flare, combustor, etc.) Any remaining gas is sent to a pipeline that feeds a local gas plant. The oil and process water in the storage tanks is loaded into tanker trucks and hauled off site for processing and disposal. APPLICABLE REGULATIONS: Utah Administrative Code (UAC) R307-500 Series for the Oil and Gas Industry, and UAC R307-201: Emission Standards: General Emission Standards; and UAC R307-150: Emission Inventories. Federal Subpart: 40 CFR 60 Subpart OOOO. SOURCE EVALUATION: Site Type: PBR-Uncontrolled Site powered by Engine. DOGM current 12 month rolling production is: 2,850 BBL's. Utah Statute R307-506 requires a source with throughput greater than 8,000 BBLs to have controls. , - 2 REGISTERED EQUIPMENT: Visible Emissions Visible emissions are within the following opacity limits: VOC Control Devices and Gasoline engines 0%, Diesel engines 20%, Natural Gas Engines and Boilers, Treater burners & Tank burners 10%, Mobile source dust 10%. [ R307-201-3] In Compliance. No visible emissions were detected. All natural gas-driven pneumatic controllers are in compliance with 40CFR 60.5390 or 60.5390a as applicable. Tagging and record keeping requirements are not required. [R307-502-4] In Compliance. All controllers functioning as designed without any issues. Pneumatic Controllers Truck loading is done by bottom filling or submerged fill pipe [R307-504(1)] In Compliance. The truck loading valves were built and designed for submerged loading. Storage Vessels Thief hatches are kept closed and latched. [R307-506-4(1)] In Compliance. All hatches were found closed at the start of the evaluation. Upon modification, the well site was re-evaluated against the thresholds of R307-506-4(2). [R307-506-4(6)] In Compliance. The DAQ did not identify any modifications or unauthorized equipment. Natural Gas Engines Affected engine exhaust vents are vertical and unrestricted. Stacks are 8' or greater if the site horsepower rating is 151 to 305 Stacks are 10' or greater if the site horse power rating is 306 or greater. [R307-510-4(3)] In Compliance. The engine exhaust stack vents vertical and meets requirements. Emission Inventory: An emissions inventory has been submitted within the past three years. [R307-150-9(1)] In Compliance. The operator submitted for the 2020 emissions inventory. Oil and Gas Industry Registration Requirement The source is registered with the DAQ. [R307-505-3(3)] In Compliance. Registration has been updated within 30 days of a company name change, removal or addition of control devices, or termination of operations. [R307-505-3(3)] In Compliance. 3 Engines subject to R307-510 shall be certified or have an initial performance test per CFR 60.4244. [R307-510-4(2)] In Compliance. Records not observed on this inspection trip. Engine certifications or initial performance tests required are kept for the life of the engine at the source. [R307-510-5] In Compliance. The engine exhaust stack vents vertical and meets requirements. Engines that were installed, relocated or modified after January 1, 2016 are required to show compliance with Table 1 of R307-510-4 through a performance test evaluation that is reviewed by the DAQ and found to be in compliance. [R307-510-4(1)] In Compliance. Records not observed on this inspection trip. Records for each of the following are kept for three years: Monthly storage vessel vent system inspections (openings, thief hatches, pressure relief devices, bypasses, etc.), if controlled. Monthly crude oil throughput Emission calculations, actuals and sampling data when used to justify an exemption to storage vessel rules Emergency storage vessel usage (dates used, emptied, and volumes), if not controlled. [R307-506-5] In Compliance. Records not observed on this inspection trip. NSPS (Part 60) OOOO: Standards of Performance for Crude Oil and Natural Gas Production, Transmission and Distribution [40 CFR 60 Subpart OOOO] In Compliance. This source is permitted with the State of Utah with legal and enforceable limits, They do not have the production that would qualify under 40CFR (60) OOOO for a tank affected facility. PREVIOUS ENFORCEMENT ACTIONS: None in the past 5 years. COMPLIANCE STATUS & RECOMMENDATIONS: In regards to the site, the overall status is: In Compliance. RECOMMENDATION FOR NEXT INSPECTION: The DAQ has no recommendations for the next inspector other than what are customary. The DAQ recommends frequency of inspections remain current as scheduled. RECOMMENDATIONS FOR NSR: None. ATTACHMENTS: None.