Loading...
HomeMy WebLinkAboutDDW-2024-012604Capacity calculation sheet.xlsx Page 1 of 10/27/2024 Division of Drinking Water Water System Capacity Calculation Sheet— yes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - yes - - - - - - - - - - - - - - - - - - - - > > > - - - > > > - - - > > > - - - > > > - - - > > > (Last Update 3/30/2017) gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 26% gpd/ERC Total (gpm)Gallons/ERC Total (gallons) gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 123.0 240.0 149,000 *Enter the green cells only* Meadows Ranch 11045System Name System Number per residential connection other connections flow duration 1.1 Indoor Water Use 1.2 Outdoor Water Use 1.3 Fire Flow Water Use 2. Summary of Water System Capacity Requirements Number of residential connections - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - Number of other connections - - - ERCs of other connections Total Equivalent Residential Connections (ERCs) Source Storage Is the drinking water used for outdoor irrigation? Residential ERCs using drinking water for irrigation Percentage of Residential ERCs using DW for irrigation Average irrigated acreage Total irrigated acreage of (park, school, etc.) Irrigation zone Source Storage Does the water system provide fire protection? Maximum fire demand (in gpm) for or Maximum fire suppression (in hours) for or Required Fire Suppression Storage (in gallons) - - - - - - - - 190 0 0.9 50 0.10 0.00 (Enter notes here regarding whether and what % of irrigation water is supplied by PWS.) 3 Enter notes here, e.g. fire official contact info or comments.) (Example: water use of 2 factories equals to water use of 55 homes.) 190.9 MIN. REQUIREMENTS FOR INDOOR WATER USE MIN. REQUIREMENTS FOR IRRIGATION USE 60,000 MINIMUM REQUIREMENTS FOR WATER SYSTEM Source Storage None 195.1% 800 400 488 253 1,288 653 106.1 76,360 17.0 12,640 123.0 149,000 Map Zones 1 2 3 4 5 6 water system pressure zone water system pressure zone 1,000 1 (*Verify req'd fire flow and duration with local fire code officials.* (indoor + outdoor)(indoor + outdoor + fire) 2.1 Does this system have adequate source capacity (per R309-510-7)? Required Source Capacity gpm Existing Source Capacity gpm Source Capacity Deficit gpm Existing % of Total Req'd 2.2 Does this system have adequate storage capacity (per R309-510-8)? Total Required Storage gal This source capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. This storage capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Capacity calculation sheet.xlsx Page 2 of 10/27/2024 Existing Storage Capacity gal Storage Capacity Deficit gal gal Is storage deficiency solely due to fire storage? Existing % of Total Req'd w/ flush toilets w/o flush toilets w/ flushometer valves 305,000 60,000 MINIMUM REQUIREMENTS FOR INDOOR USE 60 0 30 0 20 0 10 0 5 0 2.5 0 N/A 100 N/A 50 7 3.5 8.8 Total Existing Source Capacity (in gpm) Total Projected ERCs Total Existing Storage Cap. (in gallons) None Not Applicable 204.7% Modern Recreation Camp 0.00 0.0 Semi-Developed Camp 0.00 0.0 Semi-Developed Camp 0.00 0.0 RV Park 0.13 0.0 Roadway Rest Stop 0.0 240 190 305,000 Required Fire Storage (See R309-510, Tables 510-1, 2, & 4 for other facility types.) Number of people per camp site 3. Transient PWS Indoor Water Use ERC Calcuation 4. Data Input for Calculating ERCs, Source and Storage — Source Storage Facility Type Source Storage GPD/person*GPD/site or pad Gallons/person Gallon/siteor pad ERC/site or pad (GPD/vehicle)(Gal./vehicle) ERC/1000 vehicles served Vehicles served/day Residential Connections Obligated ERCs Total # of sites/pads ERCs ERCs Existing Future 0 0 0 0 0 0 WS003 Well #3 East 120 WS004 Well #4 East 120 190 5 connections 5 ST001 South Tank 175,000 ST002 North Tank 130,000 (Enter notes here. If additional space is needed, click the "Additional Notes" tab on the bottom of the screen.) 4.2 Summary - Existing Sources 4.1 Projected ERCs Calculation (optional) 4.3 Summary - Existing Storage Tanks (enter in green cells below) (enter below) (enter below) Meadows Ranch Maximum ERCs (assuming indoor use only)432 Capacity calculation sheet.xlsx Page 3 of 10/27/2024 Additional Notes System Name: System Number:Meadows Ranch 11045 (Enter additional notes here, for example, water system information related to capacity calculations, etc.) Capacity calculation sheet.xlsx Page 4 of 10/27/2024 Capacity calculation sheet.xlsx Page 5 of 10/27/2024 Irrigation Demands & ERCs (This reference table is used to automate the calculations in the PWS Capacity Calculation sheet. Do not alter.) System Name: System Number:Meadows Ranch 11045 Zone Peak Day Avg Year Storage Demand Demand Reqmt (to be added to indoor and fire flow demands) 3.39 1.66 2,528 Avg. Yr.Storage Peak Peak Day (ac-ft/yr Requirement Instantaneous zone (gpm/irr. ac)per irr. ac.)(gal/irr. ac)(gpm/irr. ac) 1 2.26 1.17 1,782 4.52 2 2.80 1.23 1,873 5.60 3 3.39 1.66 2,528 6.78 4 3.96 1.87 2,848 7.92 5 4.52 2.68 4,081 9.04 6 4.90 3.26 4,964 9.80 IRRIGATION DEMANDS 3 Capacity calculation sheet.xlsx Page 6 of 10/27/2024