Loading...
HomeMy WebLinkAboutDERR-2024-011647Utah Department of Environmental Quality - UST Release Detection TANK OWNERSHIP Name ABF Address 8401 MCCLURE DR FORT SMITH, AR 72916 Contact ABF Phone Email None TANK LOCATION Name ABF FREIGHT SYSTEM, INC Address 6070 W 150 S SALT LAKE CITY, UT 84118 A Operator None Phone None B Operator SAME Phone SAME Facility ID: 4002651 Inspection Date: 10/23/2024 DISPENSER DETAILS DISP ID/ALT ID SUBSTANCE UDC PIPE FLEX LOC INSTALL DATE UDC INSTALL DATE FIRE VALVE SAT PRESENT UDC TEST DISP FLEX CP TEST TANK DETAILS Tank ID/Alt ID 1 / 1 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Sept. 7, 2022 / 20000 / South Substance Stored Diesel / Tank Material-Mod Other-Double-Walled ATG / LTT Test None LLD Test None Pipe Material- Mod Not Listed / Double-Walled Pipe type/STP Cont Pressurized / Yes STP Flex Connectors LLD Model Spill/Overfill/Sm Delivery / Automatic shutoff / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankATG / TankTightness PipeLineTightness CP Tank Test None CP Pipe Test None Tank ID/Alt ID 2 / 2 E-Gen/AST No / Yes Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Sept. 7, 2022 / 20000 / North Substance Stored Diesel / Tank Material-Mod Other- ATG / LTT Test None LLD Test None Pipe Material- Mod Not Listed / Double-Walled Pipe type/STP Cont Pressurized / Yes STP Flex Connectors LLD Model Spill/Overfill/Sm Delivery / Automatic shutoff / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankATG / TankTightness PipeLineTightness CP Tank Test None CP Pipe Test None INSPECTION COMMENTS None 2024-10-23 Page 1 of 3 FACILITY RESPONSES Financial Responsibility Financial responsibility method is ok?Yes The above accurately represents the facility's release detection records Yes TANK RESPONSES Tank 1 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 1 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Tank 2 Pressure Piping Leak Detection Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 2 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Tank 1 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Tank 1 ATG/IM ATG/IM - ATG console or other equipment used to take readings and perform tests is adequate, accessible, and operational? Yes ATG/IM - Documentation of valid testing or monitoring is available (must have records for the two most recent months and 10 of last 12 months)? Show results in the RD tab. Yes Tank 2 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Tank 2 ATG/IM ATG/IM - ATG console or other equipment used to take readings and perform tests is adequate, accessible, and operational? Yes ATG/IM - Documentation of valid testing or monitoring is available (must have records for the two most recent months and 10 of last 12 months)? Show results in the RD tab. Yes DISPENSER RESPONSES MONTHLY LEAK DETECTION MONITORING Oct '23 Nov '23 Dec '23 Jan '24 Feb '24 Mar '24 Apr '24 May '24 Jun '24 Jul '24 Aug '24 Sep '24 Tank 1 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Tank 2 Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Line Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl Not Appl 2024-10-23 Page 2 of 3 Prepared by fueloperator.com NON-COMPLIANCE ITEMS All items are in compliance. Inspection Information Inspector:Rasmussen, DeAnn Record Created:Oct. 23, 2024, 1:17 p.m. Inspection Date:Oct. 23, 2024 2024-10-23 Page 3 of 3