Loading...
HomeMy WebLinkAboutDDW-2024-012540DDW-2017-004386 - 0901a068806e65f1.xlsx Page 1 of 10/23/2024 Division of Drinking Water Water System Capacity Calculation Sheet— - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - > > > - - - > > > - - - > > > - - - > > > - - - > > > gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 0% gpd/ERC Total (gpm)Gallons/ERC Total (gallons) gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 56.1 120.0 (Last Updat *Enter the green cells only* SWISS ALPINE WATER COMPANY 26049System Name System Number per residential connection other connections flow duration 1.1 Indoor Water Use 1.2 Outdoor Water Use 1.3 Fire Flow Water Use 2. Summary of Water System Capacity Requirements Number of residential connections - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - Number of other connections - - - ERCs of other connections Total Equivalent Residential Connections (ERCs) Source Storage Is the drinking water used for outdoor irrigation? Residential ERCs using drinking water for irrigation Percentage of Residential ERCs using DW for irrigation Average irrigated acreage Total irrigated acreage of (park, school, etc.) Irrigation zone Source Storage Does the water system provide fire protection? Maximum fire demand (in gpm) for or Maximum fire suppression (in hours) for or Required Fire Suppression Storage (in gallons) - - - - - - - - 101 0 0.00 0.00 (Enter notes here regarding whether and what % of irrigation water is supplied by PWS.) 1 Enter notes here, e.g. fire official contact info or comments.) 101.0 MIN. REQUIREMENTS FOR INDOOR WATER USE MIN. REQUIREMENTS FOR IRRIGATION USE 120,000 MINIMUM REQUIREMENTS FOR WATER SYSTEM Source Storage None 213.9% 800 400 0 0 800 400 56.1 40,400 0.0 0 56.1 160,400 water system pressure zone water system pressure zone 1,000 2 (*Verify req'd fire flow and duration with local fire code officials.* (indoor + outdoor)(indoor + outdoor + fire) 2.1 Does this system have adequate source capacity (per R309-510-7)? Required Source Capacity gpm Existing Source Capacity gpm Source Capacity Deficit gpm Existing % of Total Req'd This source capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. DDW-2017-004386 - 0901a068806e65f1.xlsx Page 2 of 10/23/2024 2.2 Does this system have adequate storage capacity (per R309-510-8)? Total Required Storage gal Existing Storage Capacity gal Storage Capacity Deficit gal gal Is storage deficiency solely due to fire storage? Existing % of Total Req'd w/ flush toilets w/o flush toilets w/ flushometer valves Required Fire Storage (See R309-510, Tables 510-1, 2, & 4 for other facility types.) Number of people per camp site This storage capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones 160,400 299,000 120,000 MINIMUM REQUIREMENTS FOR INDOOR USE 60 0 30 0 20 0 10 0 5 0 2.5 0 N/A 100 N/A 50 7 3.5 8.8 Total Existing Source Capacity (in gpm) Total Projected ERCs Total Existing Storage Cap. (in gallons) None Not Applicable 186.4% Modern Recreation Camp 0.00 Semi-Developed Camp 0.00 Semi-Developed Camp 0.00 RV Park 0.13 Roadway Rest Stop 0.0 0 3. Transient PWS Indoor Water Use ERC Calcuation 4. Data Input for Calculating ERCs, Source and Storage — Source Storage Facility Type Source Storage GPD/person*GPD/site or pad Gallons/person Gallon/site or pad ERC/site or pad (GPD/vehicle)(Gal./vehicle) ERC/1000 vehicles served Vehicles served/day Residential Connections Obligated ERCs ERCs Existing Future 0 WS001 WS002 SWISS ALPINE WELL ST001 LOWER TANK ST002 UPPER TANK (Enter notes here. If additional space is needed, click the "Additional Notes" tab on the bottom of the screen.) UPPER DEVILS HOLE SPRI4.1 Projected ERCs Calculation (optional) 4.2 Summary - Existing Sources 4.3 Summary - Existing Storage Tanks (enter below) (enter in gree (enter SWISS ALPINE WATER COMPANY Maximum ERCs (assuming indoor use only) DDW-2017-004386 - 0901a068806e65f1.xlsx Page 3 of 10/23/2024 te 3/30/2017) (Example: water use of 2 factories equals to water use of 55 homes.) Map Zones 1 0 3 4 5 6 . DDW-2017-004386 - 0901a068806e65f1.xlsx Page 4 of 10/23/2024 s. Total # of sites/pads ERCs 0 0 0 0 40 80 49,000 250,000 0.0 0.0 0.0 0.0 120 299,000 n cells below) r below) 216