HomeMy WebLinkAboutDDW-2024-012414System Number 15044 1.1 Indoor Water Use Number of residential connections - - - - - - - - - - -- - - - - - - - - - - - - - - - - - -- - - - - - - - -750 Number of other connections - - - ERCs of other connections 0.0 Total Equivalent Residential Connections (ERCs)750.0 gpd/ERC Total (gpm) Gallons/ERC Total (gallons) 800 416.7 400 300,000 1.2 Outdoor Water Use Is the drinking water used for outdoor irrigation? Residential ERCs using drinking water for irrigation - - - - - - - - - - - - > > >0 Percentage of Residential ERCs using DW for irrigation - - - - - - - - - - - - > > >0%Map Zones Average irrigated acreage per residential connection - - - - - - - - - - - - > > >0.00 1 Total irrigated acreage of other connections (park, school, etc.)- - - - - - - - - - - - > > >0.00 2 Irrigation zone 1 3 4 5 6 gpd/ERC Total (gpm) Gallons/ERC Total (gallons) 0 0.0 0 0 1.3 Fire Flow Water Use Does the water system provide fire protection? Maximum fire flow demand (in gpm) for water system or pressure zone 0 Maximum fire suppression duration (in hours) for water system or pressure zone 0 Required Fire Suppression Storage (in gallons) - - - - - - - - - - - - - - - - - - - - > > >0 2. Summary of Water System Capacity Requirements gpd/ERC Total (gpm) Gallons/ERC Total (gallons) 800 416.7 400 300,000 2.1 Does this system have adequate source capacity (per R309-510-7)? Required Source Capacity 416.7 gpm Existing Source Capacity 1,199.0 gpm Source Capacity Deficit None gpm Existing % of Total Req'd 287.8% MIN. REQUIREMENTS FOR INDOOR WATER USE MINIMUM REQUIREMENTS FOR WATER SYSTEM Division of Drinking Water — Water System Capacity Calculation Sheet (Last Update 3/30/2017) *Enter the green cells only* (Example: water use of 2 factories equals to water use of 55 homes.) Source MIN. REQUIREMENTS FOR IRRIGATION USE System Name Source Wasatch Peaks Ranch Resort Storage (Enter notes here regarding whether and what % of irrigation water is supplied by PWS.) Source (indoor + outdoor) Storage Storage (indoor + outdoor + fire) This source capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Yes No Yes No 2022 Capacity Calculations Page 1 of 2 10/18/2024 2.2 Does this system have adequate storage capacity (per R309-510-8)? Total Required Storage 300,000 gal Existing Storage Capacity 400,000 gal Storage Capacity Deficit None gal Required Fire Storage 0 gal Not Applicable Existing % of Total Req'd 133.3% 3. Transient PWS Indoor Water Use — ERC Calcuation (See R309-510, Tables 510-1, 2, & 4 for other facility types.) GPD/person* GPD/site or pad Gallons/person Gallon/site or pad ERC/site or pad Total # of sites/pads ERCs 60 0 30 0 0.00 0 0.0 20 0 10 0 0.00 0 0.0 5 0 2.5 0 0.00 0 0.0 N/A 100 N/A 50 0.13 0 0.0 Number of people per camp site 0 Source (GPD/vehicle) Storage (Gal./vehicle) ERC/1000 vehicles served Vehicles served/day ERCs 7 3.5 8.8 0 0.0 4. Data Input for Calculating ERCs, Source and Storage 4.2 Summary - Existing Sources (enter in green cells below) Total Existing Source Capacity (in gpm)1,199 4.1 Projected ERCs Calculation (optional)WS001 WELL A 770 Total Projected ERCs 750 WS003 WELL A2 429 Existing Residential Connections 750 Obligated Future ERCs (enter below) Maximum ERCs (assuming indoor use only) 2158.2 4.3 Summary - Existing Storage Tanks (enter below) Total Existing Storage Cap. (in gallons)400,000 ST001 TANK 1 100,000 ST002 TANK 2 100,000 ST003 TANK 3 100,000 ST004 TANK 4 100,000 RV Park Facility Type Source MINIMUM REQUIREMENTS FOR INDOOR USE Modern Recreation Camp Storage Semi-Developed Camp w/ flush toilets Wasatch Peaks Ranch Resort Roadway Rest Stop w/ flushometer valves Semi-Developed Camp w/o flush toilets This storage capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Is storage deficiency solely due to fire storage? 2022 Capacity Calculations Page 2 of 2 10/18/2024