Loading...
HomeMy WebLinkAboutDERR-2024-011460Utah Department of Environmental Quality - UST Release Detection TANK OWNERSHIP Name ADMIRAL BEVERAGE CORPORATION Address 531 WEST 600 NORTH SALT LAKE CITY, UT 84116 Contact ADMIRAL BEVERAGE CORPORATION Phone Email dgraves@admiralbeverages.com TANK LOCATION Name M & M DISTRIBUTING CO. Address 531 WEST 600 NORTH SALT LAKE CITY, UT 84116 A Operator DYLAN GRAVES Phone (801) 807-8717 B Operator SAME Phone SAME Facility ID: 4000324 Inspection Date: 10/16/2024 DISPENSER DETAILS DISP ID/ALT ID SUBSTANCE UDC PIPE FLEX LOC INSTALL DATE UDC INSTALL DATE FIRE VALVE SAT PRESENT UDC TEST DISP FLEX CP TEST 1 - Diesel Diesel No Booted Steel Flex Oct. 1, 1988 None Yes No None None TANK DETAILS Tank ID/Alt ID 5 / 5 E-Gen/AST No / No Siphon/Compart No / No Tank Status Currently In Use Installed/Cap/Loc Oct. 1, 1988 / 12000 / Single Substance Stored Diesel / Diesel #2 (U.L.S.) Tank Material- Mod Fiberglass Reinforced Plastic- Double-Walled ATG / LTT Test None LLD Test March 15, 2024 Pipe Material- Mod Fiberglass Reinforced Plastic / None Pipe type/STP Cont Pressurized / No STP Flex Connectors Steel Flex in Sump LLD Model Vaporless LD2000 Spill/Overfill/Sm Delivery 5 gal. Spill Bucket / Automatic shutoff / No PST Fund/Other Type Yes / None Tank/Pipe Rel Det TankSIR PipeAutoLineLeakDetection / PipeSIR / PipeSIR CP Tank Test None CP Pipe Test None INSPECTION COMMENTS None 2024-10-17 Page 1 of 4 FACILITY RESPONSES Financial Responsibility Financial responsibility method is ok?Yes The above accurately represents the facility's release detection records Yes Operator Training A Operator current?Yes B Operator current?Yes Monthly checklist available and complete?Yes Is the site unmanned?Yes Is a sign posted in a conspicuous area giving the name and telephone number of a person in case of an emergency and if the station is manned part of the time, are C operators trained? Yes Does the site have emergency shutoff device?Yes TANK RESPONSES Tank 5 Spill/Overfill Tank has a spill prevention device?Yes Are you able to visually inspect the spill containment bucket(s) for functionality? (i.e. are the buckets clean enough to see cracks, etc?) Yes Is the spill containment bucket intact?Yes Is the spill containment bucket(s) able to contain a spill? (i.e. is there water, product, debris, etc in the spill bucket to prevent it from containing a spill?) Yes Tank has an overfill device?Yes Tank 5 Cathodic Protection Tanks are protected from corrosion?Yes Piping is protected from corrosion?Yes Flex connectors at the tank sub-pumps are protected from corrosion?Yes Tank 5 Pressure Piping Leak Detection Does the pressurized piping system have a line leak detector?Yes Does the pressurized piping system have a valid line leak detector test?Yes Does the pressurized piping system have a valid annual line tightness test or valid monthly monitoring? Yes Tank 5 Spill/Overfill Does the spill bucket have a valid 3- year test, valid monthly monitoring for DW buckets, or the tank is exempt? Yes Does the overfill device have a valid 3- year test or the tank is exempt?Yes 2024-10-17 Page 2 of 4 Tank 5 SIR/MTG SIR - Dispensers have current calibration stickers or proper calibration documentation? Yes SIR - Drop tubes are present and extend to within one foot of the tank bottom? Yes SIR - Inventory readings for product inputs, withdrawals, and the amount remaining in the tank are recorded and available for each operating day? Yes SIR - Product inputs are reconciled with delivery receipts by measurement of the tank inventory volume before and after deliveries? Yes SIR - Records include the appropriate number of water readings, and water readings are used to adjust inventory balances as necessary? Yes SIR/MTG - An appropriate calibration chart is used to convert product level readings to gallons, and is available for review? Yes SIR/MTG - Inventory readings are properly reconciled monthly (weekly and monthly for MTG) to the appropriate allowable amount? Yes SIR/MTG - Equipment used to take readings (ATG, Gauge Stick, etc.) is adequate, accessible, and operational? Yes SIR/MTG - Documentation of valid testing or monitoring is available (must have records for the two most recent months and 10 of last 12 months)? Show results in the RD tab. Yes DISPENSER RESPONSES Dispenser Diesel Flex connectors at the dispensers are protected from corrosion?Yes Fire valve is anchored properly?Yes Does the line tightness test port on the fire valve have the manufacturers plug installed in it? (no ball valves) Yes Is the fire valve located properly below grade?Yes Is the fire valve's fuseable link intact?Yes MONTHLY LEAK DETECTION MONITORING Oct '23 Nov '23 Dec '23 Jan '24 Feb '24 Mar '24 Apr '24 May '24 Jun '24 Jul '24 Aug '24 Sep '24 Tank 5 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Line Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass NON-COMPLIANCE ITEMS All items are in compliance. 2024-10-17 Page 3 of 4 Prepared by fueloperator.com Inspection Information Inspector:Rasmussen, DeAnn Record Created:Oct. 17, 2024, 8 a.m. Inspection Date:Oct. 16, 2024 2024-10-17 Page 4 of 4