Loading...
HomeMy WebLinkAboutDDW-2024-012178Newton Town 2024.xlsx Page 1 of 10/15/2024 *Enter the green cells only* System Name Newton Town 2024 System Number 03013 1.1 Indoor Water Use Number of residential connections - - - - - - - - - - -- - - - - - - - - - - - - - - - - - -- - - - - - - - -280 Number of other connections - - - 0 ERCs of other connections 0.0 (Example: water use of 2 factories equals to water use of 55 homes.) Total Equivalent Residential Connections (ERCs)280.0 MIN. REQUIREMENTS FOR INDOOR WATER USE Source Storage gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 800 155.6)400 (112,000) 1.2 Outdoor Water Use Is the drinking water used for outdoor irrigation? yes Residential ERCs using drinking water for irrigation - - - - - - - - - - - - > > >280 Percentage of Residential ERCs using DW for irrigation - - - - - - - - - - - - > > >100%Map Zones Average irrigated acreage per residential connection - - - - - - - - - - - - > > >0.20 1 Total irrigated acreage of other connections (park, school, etc.)- - - - - - - - - - - - > > >0.00 2 (Enter notes here regarding whether and what % of irrigation water is supplied by PWS.) Irrigation zone 3 3 4 5 MIN. REQUIREMENTS FOR IRRIGATION USE 6 Source Storage gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 976 189.8 506 141,568 1.3 Fire Flow Water Use Does the water system provide fire protection? Maximum fire flow demand (in gpm) for water system or pressure zone 1,000 Maximum fire suppression duration (in hours) for water system or pressure zone 2 Required Fire Suppression Storage (in gallons) - - - - - - - - - - - - - - - - - - - - > > >120,000 (*Verify req'd fire flow and duration with local fire code officials.* Enter notes here, e.g. fire official contact info or comments.) 2. Summary of Water System Capacity Requirements MINIMUM REQUIREMENTS FOR WATER SYSTEM Source (indoor + outdoor)Storage (indoor + outdoor + fire) gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 1,776 345.4 906 373,568 2.1 Does this system have adequate source capacity (per R309-510-7)? This source capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Required Source Capacity 345.4 gpm Existing Source Capacity 439.0 gpm Source Capacity Deficit None gpm Existing % of Total Req'd 127.1% Newton Town 2024.xlsx Page 2 of 10/15/2024 2.2 Does this system have adequate storage capacity (per R309-510-8)? This storage capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Total Required Storage 373,568 gal Existing Storage Capacity 500,000 gal Storage Capacity Deficit None gal Required Fire Storage 120,000 gal Is storage deficiency solely due to fire storage?Not Applicable Existing % of Total Req'd 133.8% 3. Transient PWS Indoor Water Use — ERC Calcuation (See R309-510, Tables 510-1, 2, & 4 for other facility types.) MINIMUM REQUIREMENTS FOR INDOOR USE Source Storage Facility Type GPD/person*GPD/site or pad Gallons/person Gallon/site or pad ERC/site or pad Total # of sites/pads ERCs Modern Recreation Camp 60 0 30 0 0.00 0 0.0 Semi-Developed Camp w/ flush toilets 20 0 10 0 0.00 0 0.0 Semi-Developed Camp w/o flush toilets 5 0 2.5 0 0.00 0 0.0 RV Park N/A 100 N/A 50 0.13 0 0.0 Number of people per camp site 0 Source (GPD/vehicle) Storage (Gal. /vehicle) ERC/1000 vehicles served Vehicles served/day ERCs Roadway Rest Stop w/ flushometer valves 7 3.5 8.8 700 6.1 4. Data Input for Calculating ERCs, Source and Storage 4.2 Summary - Existing Sources (enter in green cells below) Newton Town 2024 Total Existing Source Capacity (in gpm)439 4.1 Projected ERCs Calculation (optional)WS001 Northfork 83 Total Projected ERCs 0 WS002 Big Birch 85 Existing Residential Connections WS003 Little Birch 115 Obligated Future ERCs (enter below)0 WS004 Butters WS005 Loosle 75 WS007 Woodward 18 WS008 Craw 18 WS009 Christiansen 29 WS010 Goodsell 16 Total Cap 439 Actual Inflow 240+75 Maximum ERCs (assuming indoor use only)790.2 4.3 Summary - Existing Storage Tanks (enter below) Total Existing Storage Cap. (in gallons)500,000 ST001 Newton Tank 500,000 (Enter notes here. If additional space is needed, click the "Additional Notes" tab on the bottom of the screen.)