Loading...
HomeMy WebLinkAboutDERR-2024-011423 Utah Department of Environmental Quality Permanent Closure Inspection Facility ID 4001342 Page of Ownership of Tanks Location of Tanks Owner Name CTP DEV LLC Location Name ABF FREIGHT SITE Address 9350 S 150 E, STE 900 Address55 S REDWOOD RD City State Zip Sandy, UT 84070 City State UT Zip SALT LAKE CITY UT 84104 Contact Phone Carl Duke Contact Phone(801) 910-6254 Tanks Closed. Use additional pages for additional tanks. Tank No. 4 Tank No. 5 Tank No. 6 Tank No. 7 Capacity (gallons) 12000 12000 12000 12000 Material of Construction (Steel, FRP, Composite, etc.) FRP FRP FRP FRP Substance Stored Diesel Diesel Diesel Dieel Date Last Used UNK UNk UNK UNK Date Permanently Closed 05/01/2024 05/01/2024 05/01/2024 05/01/2024 How Closed (Removed, In Place, Change In Service) Removed Removed Removed Removed Original Number of tanks: 4 Closed Tanks: 4 New Tanks: 0 Final Number of tanks: 0 Tank Cleaning and Removal UST Remover: Aaron Spackman Cert. #: TR 436 Exp. Date: 04/01/2025 Groundwater/soil Sampler: Aaron Spackman Cert. #: GS 1738 Exp. Date: 02/15/2025 Owner/Operator has an approved Closure Plan Yes No YES A copy of the approved Closure Plan is on site Yes No YES Product removed Yes No By: Sump & Trap Disposal Site:Sump & Trap Sludge removed Yes No By: Sump & Trap Disposal Site: Sump & Trap Tanks cleaned Yes No By: Sump & Trap Rinsate disposal site: Non-explosive atmosphere inside tank obtained by: Purging Inerting PURGING LEL or % Oxygen obtained: Product lines were: Cleaned, secured in place, and capped Removed. Disposal site: Partially removed – piping goes under a building that will be removed later Tank disposal site: Landfill Soil disposal site: Site Assessment PID or FID meter readings (show reading locations on the site plat): Meter Type: Gain or span: Calibration specs: Soil Contamination is evident: Yes No YES Depth of Contamination: 0-3 Feet Greater than 3 Feet YES Groundwater contamination is evident: Yes No YES Depth to Water Table: 6-9 ft bgs Surface slope direction: NW Number of samples collected: GW Soil USC Certified Lab: Land Use of surrounding area: Residential Industrial Commercial Other (specify): Show sample analysis information below. Samples with the same analysis can be grouped together. Include any samples taken by theinspector. Show sample types (including USC), locations, and depths on the site plat. Sample number(s) Substance in Tank Sample Type Compounds analyzed Analysis Methods Inspector observed collection of samples: Yes No Inspector collected and submitted duplicate samples: Yes No Contaminated soil was over-excavated: Yes No n/a If yes, confirmation samples were collected: Yes No Potential Receptors. Indicate the distance (in feet) and direction to the nearest receptors. Show receptor locations on the site plat. Residences Commercial Buildings Property Line Active Water Well Surface Water Sewer Line Water Line Natural Gas Line Telephone Line Electrical Line Storm Drain Other: I (name) certify that I inspected the above-named facility on (date): DeAnn Rasmussen Inspector signature: Cert. #: TI Closureinsp0908.doc Utah Department of Environmental Quality UST Facility Site Plat Facility ID Page of NORTH UTM Northing: Easting: Sub Pump STank Fill F ATG Probe A Inter. Probe I Vapor Rec. V Capped C Other (specify) O Show locations of all buildings, streets, tanks, piping, and dispenser islands. Indicate the product in each tank. Show locations of tank manways and identify each: submersible pump, fill, ATG probe, vapor recovery, etc. For closures: Indicate the type (soil, GW, USC), location, and depth of each sample collected by the certified sampler or the inspector. Indicate the locations of any reported PID or FID readings. Show locations of potential receptors. Comments A water main was broken that went to the fire hydrant near the tank pit on 10/07/2024. Water had to be pumped from the tank pit and put in a frac tank on 10/07/2024. The excavation was very stained and the water had some sheen on it especially on the east end. Siteplat0908.doc