Loading...
HomeMy WebLinkAboutDAQ-2024-0108951 DAQC-992-24 Site ID 11841 (B4) MEMORANDUM TO: STACK TEST FILE – PEPPERIDGE FARM INCORPORATED – Commercial Bakery – Cache County THROUGH: Rik Ombach, Minor Source Oil and Gas Compliance Section Manager FROM: Kyle Greenberg, Environmental Scientist DATE: October 1, 2024 SUBJECT: Source: Process Line No. 11 Location: 901 North 200 West, Richmond, Cache County, UT Contact: Tony Hernandez: 435-750-8405 Tester: Alliance Source Testing Site ID #: 11841 Permit/AO #: DAQE-AN118410010-24, dated July 26, 2024 Subject: Review of Pretest Protocol received September 24, 2024 On September 24, 2024, DAQ received a protocol for the testing of Process Line No. 11 at Pepperidge Farm Inc. Commercial Bakery in Cache County, UT. Testing will be performed October 24, 2024, to determine compliance with the emission limits found in Condition II.B.2 of DAQE-AN118410010-24. PROTOCOL CONDITIONS: 1. RM 1 used to determine sample velocity traverses: OK 2. RM 2 used to determine stack gas velocity and volumetric flow rate: OK 3. RM 3A used to determine O2 and CO2 concentrations: OK 4. RM 4 used to determine moisture content: OK 5. RM 25A used to determine VOC emissions: OK 6. RM 205 used to verify gas dilution systems for field instrument calibrations: OK DEVIATIONS: None. CONCLUSION: The protocol appears to be acceptable. RECOMMENDATION: The test methods proposed in the pretest protocol are capable to determine total VOC emissions in lb/hr. ATTACHMENTS: Alliance Source Testing Pretest Protocol Site Specific Test Plan Pepperidge Farm Incorporated Commercial Bakery 901 North 200 West Richmond, UT 84333 Source to be Tested: Process Line No. 11 Proposed Test Date: October 24, 2024 Project No. AST-2024-4537 Prepared By Alliance Technical Group, LLC 3683 W 2270 S, Suite E West Valley City, UT 84120 Site Specific Test Plan Test Program Summary AST-2024-4537 Pepperidge – Richmond, UT Page i Regulatory Information Permit No. DAQE-AN118410010-24 Source Information Source Name Target Parameter Process Line No. 11 VOC Contact Information Test Location Test Company Pepperidge Farm Incorporated Commercial Bakery 901 North 200 West Richmond, UT 84333 Tony Hernandez tony_j_hernandez@campbells.com (435) 750-8405 Alliance Technical Group, LLC 3683 W 2270 S, Suite E West Valley City, UT 84120 Project Manager Charles Horton charles.horton@alliancetg.com (352) 663-7568 Field Team Leader Ryan Lyons ryan.lyons@stacktest.com (708) 214-4850 (subject to change) QA/QC Manager Kathleen Shonk katie.shonk@alliancetg.com (812) 452-4785 Test Plan/Report Coordinator Delaine Spangler delaine.spangler@alliancetg.com Site Specific Test Plan Table of Contents AST-2024-4537 Pepperidge – Richmond, UT Page ii TABLE OF CONTENTS 1.0 Introduction ................................................................................................................................................. 1-1 1.1 Facility Descriptions ................................................................................................................................... 1-1 1.2 Project Team ............................................................................................................................................... 1-1 1.3 Safety Requirements ................................................................................................................................... 1-1 2.0 Summary of Test Program .......................................................................................................................... 2-1 2.1 General Description ..................................................................................................................................... 2-1 2.2 Process/Control System Parameters to be Monitored and Recorded ........................................................... 2-1 2.3 Proposed Test Schedule............................................................................................................................... 2-1 2.4 Emission Limits ........................................................................................................................................... 2-2 2.5 Test Report .................................................................................................................................................. 2-2 3.0 Testing Methodology .................................................................................................................................. 3-1 3.1 U.S. EPA Reference Test Methods 1 and 2 – Sampling/Traverse Points and Volumetric Flow Rate ........ 3-1 3.2 U.S. EPA Reference Test Method 3A – Oxygen/Carbon Dioxide .............................................................. 3-1 3.3 U.S. EPA Reference Test Method 4 – Moisture Content ............................................................................ 3-2 3.4 U.S. EPA Reference Test Method 25A – Volatile Organic Compounds .................................................... 3-2 3.5 U.S. EPA Reference Test Method 205 – Gas Dilution System Certification .............................................. 3-2 3.6 Quality Assurance/Quality Control – U.S. EPA Reference Test Method 3A.............................................. 3-2 3.7 Quality Assurance/Quality Control – U.S. EPA Reference Test Method 25A ............................................ 3-3 4.0 Quality Assurance Program ......................................................................................................................... 4-1 4.1 Equipment ................................................................................................................................................... 4-1 4.2 Field Sampling ............................................................................................................................................ 4-2 LIST OF TABLES Table 1-1: Project Team ........................................................................................................................................... 1-1 Table 2-1: Program Outline and Tentative Test Schedule ........................................................................................ 2-2 Table 2-2: Emission Limits ...................................................................................................................................... 2-2 Table 3-1: Source Testing Methodology .................................................................................................................. 3-1 LIST OF APPENDICES Appendix A Method 1 Data Appendix B Example Field Data Sheets Site Specific Test Plan Introduction AST-2024-4537 Pepperidge – Richmond, UT Page 1-1 1.0 Introduction Alliance Technical Group, LLC (Alliance) was retained by Pepperidge Farm Incorporated (Pepperidge) to conduct compliance testing at the Richmond, Utah facility. Portions of the facility are subject to provisions of the Utah Department of Environmental Quality, Division of Air Quality (UDAQ) Permit No. DAQE-AN118410010-24. Testing will be conducted to determine the emission rates of volatile organic compounds (VOC) from the Catalytic Oxidizer installed on Process Line No.11. This site-specific test plan (SSTP) has been prepared to address the notification and testing requirements of the UDAQ permit. 1.1 Facility Descriptions Pepperidge Farm Inc. owns and operates a commercial baking plant in Richmond, Utah. The plant operates Process Line No. 11. Process line No. 11 is a Natural Gas/Propane Fired Oven; emissions are controlled with a Catalytic Oxidizer for VOC (ethanol) destruction. 1.2 Project Team Personnel planned to be involved in this project are identified in the following table. Table 1-1: Project Team Pepperidge Personnel Tony Hernandez Regulatory Agency UDAQ Alliance Personnel Ryan Lyons other field personnel assigned at time of testing event 1.3 Safety Requirements Testing personnel will undergo site-specific safety training for all applicable areas upon arrival at the site. Alliance personnel will have current OSHA or MSHA safety training and be equipped with hard hats, safety glasses with side shields, steel-toed safety shoes, hearing protection, fire resistant clothing, and fall protection (including shock corded lanyards and full-body harnesses). Alliance personnel will conduct themselves in a manner consistent with Client and Alliance’s safety policies. A Job Safety Analysis (JSA) will be completed daily by the Alliance Field Team Leader. Site Specific Test Plan Summary of Test Programs AST-2024-4537 Pepperidge – Richmond, UT Page 2-1 2.0 Summary of Test Program To satisfy the requirements of the UDAQ permit, the facility will conduct a performance test program to determine the compliance status of Process Line Line No. 11. 2.1 General Description All testing will be performed in accordance with specifications stipulated in U.S. EPA Reference Test Methods 1, 2, 3A, 4 and 25A. Table 2-1 presents an outline and tentative schedule for the emissions testing program. The following is a summary of the test objectives.  Testing will be performed to demonstrate compliance with the UDAQ permit.  Emissions testing will be conducted on the exhaust of Process Line No. 11 Catalytic Oxidizer.  Performance testing will be conducted at no less than 90% of the maximum production.  Each of the three (3) test runs will be approximately 60 minutes in duration.  Alliance will utilize a Thermo Scientific Model 55i with a methane cutter to report VOC as non-methane organic compounds (NMOC).  VOC results will be reported on an as ethanol basis for comparison to permit emission limits. 2.2 Process/Control System Parameters to be Monitored and Recorded Plant personnel will collect operational and parametric data at least once every 15 minutes during the testing. The following list identifies the measurements, observations and records that will be collected during the testing program:  Production Rate – lb/hr  Production Status  Residence Time  Catalyst Outlet Temperature – °F  Temperature Rise Across Catalyst – °F 2.3 Proposed Test Schedule Table 2-1 presents an outline and tentative schedule for the emissions testing program. Site Specific Test Plan Summary of Test Programs AST-2024-4537 Pepperidge – Richmond, UT Page 2-2 Table 2-1: Program Outline and Tentative Test Schedule Testing Location Parameter US EPA Method No. of Runs Run Duration Est. Onsite Time DAY 1 – October 23, 2024 Equipment Setup & Pretest QA/QC Checks 5 hr DAY 2 – October 24, 2024 Process Line No. 11 VFR 1-2 3 60 min 10 hr O2/CO2 3A BWS 4 VOC 25A DAY 3 – October 25, 2024 Contingency Day (if needed) 2.4 Emission Limits Emission limits for each pollutant are below. Table 2-2: Emission Limits Source Pollutant Citation Process Line No. 11 VOC (as ethanol) – 3.45 lb/hr Permit 2.5 Test Report The final test report must be submitted within 60 days of the completion of the performance test and will include the following information.  Introduction – Brief discussion of project scope of work and activities.  Results and Discussion – A summary of test results and process/control system operational data with comparison to regulatory requirements or vendor guarantees along with a description of process conditions and/or testing deviations that may have affected the testing results.  Methodology – A description of the sampling and analytical methodologies.  Sample Calculations – Example calculations for each target parameter.  Field Data – Copies of actual handwritten or electronic field data sheets.  Quality Control Data – Copies of all instrument calibration data and/or calibration gas certificates.  Process Operating/Control System Data – Process operating and control system data (as provided by Pepperidge) to support the test results. Site Specific Test Plan Testing Methodology AST-2024-4537 Pepperidge – Richmond, UT Page 3-1 3.0 Testing Methodology This section provides a description of the sampling and analytical procedures for each test method that will be employed during the test program. All equipment, procedures and quality assurance measures necessary for the completion of the test program meet or exceed the specifications of each relevant test method. The emission testing program will be conducted in accordance with the test methods listed in Table 3-1. Table 3-1: Source Testing Methodology Parameter U.S. EPA Reference Test Methods Notes/Remarks Volumetric Flow Rate 1 & 2 Full Velocity Traverses Oxygen / Carbon Dioxide 3A Instrumental Analysis Moisture Content 4 Gravimetric Analysis Volatile Organic Compounds 25A Instrumental Analysis Gas Dilution System Certification 205 --- All stack diameters, depths, widths, upstream and downstream disturbance distances and nipple lengths will be measured on site with an EPA Method 1 verification measurement provided by the Field Team Leader. These measurements will be included in the test report. 3.1 U.S. EPA Reference Test Methods 1 and 2 – Sampling/Traverse Points and Volumetric Flow Rate The sampling location and number of traverse (sampling) points will be selected in accordance with U.S. EPA Reference Test Method 1. To determine the minimum number of traverse points, the upstream and downstream distances will be equated into equivalent diameters and compared to Figure 1-1 (for isokinetic sampling) and/or Figure 1-2 (measuring velocity alone) in U.S. EPA Reference Test Method 1. Full velocity traverses will be conducted in accordance with U.S. EPA Reference Test Method 2 to determine the average stack gas velocity pressure, static pressure and temperature. The velocity and static pressure measurement system will consist of a pitot tube and inclined manometer. The stack gas temperature will be measured with a K- type thermocouple and pyrometer. Stack gas velocity pressure and temperature readings will be recorded during each test run. The data collected will be utilized to calculate the volumetric flow rate in accordance with U.S. EPA Reference Test Method 2. 3.2 U.S. EPA Reference Test Method 3A – Oxygen/Carbon Dioxide The oxygen (O2) and carbon dioxide (CO2) testing will be conducted in accordance with U.S. EPA Reference Test Method 3A. Data will be collected online and reported in one-minute averages. The sampling system will consist of a stainless steel probe, Teflon sample line(s), gas conditioning system and the identified gas analyzer. The gas conditioning system will be a non-contact condenser used to remove moisture from the stack gas. If an unheated Teflon sample line is used, then a portable non-contact condenser will be placed in the system directly after the probe. Otherwise, a heated Teflon sample line will be used. The quality control measures are described in Section 3.6. Site Specific Test Plan Testing Methodology AST-2024-4537 Pepperidge – Richmond, UT Page 3-2 3.3 U.S. EPA Reference Test Method 4 – Moisture Content The stack gas moisture content will be determined in accordance with U.S. EPA Reference Test Method 4. The gas conditioning train will consist of a series of chilled impingers. Prior to testing, each impinger will be filled with a known quantity of water or silica gel. Each impinger will be analyzed gravimetrically before and after each test run on the same analytical balance to determine the amount of moisture condensed. 3.4 U.S. EPA Reference Test Method 25A – Volatile Organic Compounds The volatile organic compounds (VOC) testing will be conducted in accordance with U.S. EPA Reference Test Method 25A. Data will be collected online and reported in one-minute averages. The sampling system will consist of a stainless steel probe, heated Teflon sample line(s) and the identified gas analyzer. The quality control measures are described in Section 3.7. 3.5 U.S. EPA Reference Test Method 205 – Gas Dilution System Certification A calibration gas dilution system field check will be conducted in accordance with U.S. EPA Reference Method 205. An initial three (3) point calibration will be conducted, using individual Protocol 1 gases, on the analyzer used to complete the dilution system field check. Multiple dilution rates and total gas flow rates will be utilized to force the dilution system to perform two dilutions on each mass flow controller. The diluted calibration gases will be sent directly to the analyzer, and the analyzer response will be recorded in an electronic field data sheet. A mid-level supply gas, with a cylinder concentration within 10% of one of the gas divider settings described above, will be introduced directly to the analyzer, and the analyzer response recorded in an electronic field data sheet. The cylinder concentration and the analyzer response must agree within 2%. These steps will be repeated three (3) times. The average analyzer response must agree within 2% of the predicted gas concentration. No single injection shall differ more than 2% from the average instrument response for that dilution. 3.6 Quality Assurance/Quality Control – U.S. EPA Reference Test Method 3A Cylinder calibration gases will meet EPA Protocol 1 (+/- 2%) standards. Copies of all calibration gas certificates will be included in the Quality Assurance/Quality Control Appendix of the report. Low Level gas will be introduced directly to the analyzer. After adjusting the analyzer to the Low-Level gas concentration and once the analyzer reading is stable, the analyzer value will be recorded. This process will be repeated for the High-Level gas. For the Calibration Error Test, Low, Mid, and High-Level calibration gases will be sequentially introduced directly to the analyzer. The Calibration Error for each gas must be within 2.0 percent of the Calibration Span or 0.5% absolute difference. High or Mid-Level gas (whichever is closer to the stack gas concentration) will be introduced at the probe and the time required for the analyzer reading to reach 95 percent or 0.5% (whichever was less restrictive) of the gas concentration will be recorded. The analyzer reading will be observed until it reaches a stable value, and this value will be recorded. Next, Low-Level gas will be introduced at the probe and the time required for the analyzer reading to decrease to a value within 5.0 percent or 0.5% (whichever was less restrictive) will be recorded. If the Low-Level gas is zero gas, the acceptable response must be 5.0 percent of the upscale gas concentration or 0.5% (whichever was less restrictive). The analyzer reading will be observed until it reaches a stable value, and this value will be recorded. The measurement system response time and initial system bias will be determined from these data. The System Bias for each gas must be within 5.0 percent of the Calibration Span or 0.5% absolute difference. Site Specific Test Plan Testing Methodology AST-2024-4537 Pepperidge – Richmond, UT Page 3-3 High or Mid-Level gas (whichever is closer to the stack gas concentration) will be introduced at the probe. After the analyzer response is stable, the value will be recorded. Next, Low-Level gas will be introduced at the probe, and the analyzer value will be recorded once it reaches a stable response. The System Bias for each gas must be within 5.0 percent of the Calibration Span or 0.5% absolute difference or the data is invalidated, and the Calibration Error Test and System Bias must be repeated. The Drift between pre- and post-run System Bias must be within 3 percent of the Calibration Span or 0.5% absolute difference or the Calibration Error Test and System Bias must be repeated. To determine the number of sampling points, a gas stratification check will be conducted prior to initiating testing. The pollutant concentrations will be measured at twelve traverse points (as described in Method 1) or three points (16.7, 50.0 and 83.3 percent of the measurement line). Each traverse point will be sampled for a minimum of twice the system response time. If the pollutant concentration at each traverse point do not differ more than 5% or 0.3% (whichever is less restrictive) of the average pollutant concentration, then single point sampling will be conducted during the test runs. If the pollutant concentration does not meet these specifications but differs less than 10% or 0.5% from the average concentration, then three (3) point sampling will be conducted (stacks less than 7.8 feet in diameter - 16.7, 50.0 and 83.3 percent of the measurement line; stacks greater than 7.8 feet in diameter – 0.4, 1.0, and 2.0 meters from the stack wall). If the pollutant concentration differs by more than 10% or 0.5% from the average concentration, then sampling will be conducted at a minimum of twelve (12) traverse points. Copies of stratification check data will be included in the Quality Assurance/Quality Control Appendix of the report. A Data Acquisition System with battery backup will be used to record the instrument response in one (1) minute averages. The data will be continuously stored as a *.CSV file in Excel format on the hard drive of a computer. At the completion of testing, the data will also be saved to the Alliance server. All data will be reviewed by the Field Team Leader before leaving the facility. Once arriving at Alliance’s office, all written and electronic data will be relinquished to the report coordinator and then a final review will be performed by the Project Manager. 3.7 Quality Assurance/Quality Control – U.S. EPA Reference Test Method 25A Cylinder calibration gases will meet EPA Protocol 1 (+/- 2%) standards. Copies of all calibration gas certificates will be included in the Quality Assurance/Quality Control Appendix of the report. Within two (2) hours prior to testing, zero gas will be introduced through the sampling system to the analyzer. After adjusting the analyzer to the Zero gas concentration and once the analyzer reading is stable, the analyzer value will be recorded. This process will be repeated for the High-Level gas, and the time required for the analyzer reading to reach 95 percent of the gas concentration will be recorded to determine the response time. Next, Low and Mid- Level gases will be introduced through the sampling system to the analyzer, and the response will be recorded when it is stable. All values must be less than +/- 5 percent of the calibration gas concentrations. Mid-Level gas will be introduced through the sampling system. After the analyzer response is stable, the value will be recorded. Next, Zero gas will be introduced through the sampling system, and the analyzer value recorded once it reaches a stable response. The Analyzer Drift must be less than +/- 3 percent of the span value. Site Specific Test Plan Testing Methodology AST-2024-4537 Pepperidge – Richmond, UT Page 3-4 A Data Acquisition System with battery backup will be used to record the instrument response in one (1) minute averages. The data will be continuously stored as a *.CSV file in Excel format on the hard drive of a computer. At the completion of testing, the data will also be saved to the Alliance server. All data will be reviewed by the Field Team Leader before leaving the facility. Once arriving at Alliance’s office, all written and electronic data will be relinquished to the report coordinator and then a final review will be performed by the Project Manager. Site Specific Test Plan Quality Assurance Program AST-2024-4537 Pepperidge – Richmond, UT Page 4-1 4.0 Quality Assurance Program Alliance follows the procedures outlined in the Quality Assurance/Quality Control Management Plan to ensure the continuous production of useful and valid data throughout the course of this test program. The QC checks and procedures described in this section represent an integral part of the overall sampling and analytical scheme. Adherence to prescribed procedures is quite often the most applicable QC check. 4.1 Equipment Field test equipment is assigned a unique, permanent identification number. Prior to mobilizing for the test program, equipment is inspected before being packed to detect equipment problems prior to arriving on site. This minimizes lost time on the job site due to equipment failure. Occasional equipment failure in the field is unavoidable despite the most rigorous inspection and maintenance procedures. Therefore, replacements for critical equipment or components are brought to the job site. Equipment returning from the field is inspected before it is returned to storage. During the course of these inspections, items are cleaned, repaired, reconditioned and recalibrated where necessary. Calibrations are conducted in a manner, and at a frequency, which meets or exceeds U.S. EPA specifications. The calibration procedures outlined in the U.S. EPA Methods, and those recommended within the Quality Assurance Handbook for Air Pollution Measurement Systems: Volume III (EPA-600/R-94/038c, September 1994) are utilized. When these methods are inapplicable, methods such as those prescribed by the American Society for Testing and Materials (ASTM) or other nationally recognized agency may be used. Data obtained during calibrations is checked for completeness and accuracy. Copies of calibration forms are included in the report. The following sections elaborate on the calibration procedures followed by Alliance for these items of equipment.  Dry Gas Meter and Orifice. A full meter calibration using critical orifices as the calibration standard is conducted at least semi-annually, more frequently if required. The meter calibration procedure determines the meter correction factor (Y) and the meter’s orifice pressure differential (ΔH@). Alliance uses approved Alternative Method 009 as a post-test calibration check to ensure that the correction factor has not changed more than 5% since the last full meter calibration. This check is performed after each test series.  Pitot Tubes and Manometers. Type-S pitot tubes that meet the geometric criteria required by U.S. EPA Reference Test Method 2 are assigned a coefficient of 0.84 unless a specific coefficient has been determined from a wind tunnel calibration. If a specific coefficient from a wind tunnel calibration has been obtained that coefficient will be used in lieu of 0.84. Standard pitot tubes that meet the geometric criteria required by U.S. EPA Reference Test Method 2 are assigned a coefficient of 0.99. Any pitot tubes not meeting the appropriate geometric criteria are discarded and replaced. Manometers are verified to be level and zeroed prior to each test run and do not require further calibration.  Temperature Measuring Devices. All thermocouple sensors mounted in Dry Gas Meter Consoles are calibrated semi-annually with a NIST-traceable thermocouple calibrator (temperature simulator) and verified during field use using a second NIST-traceable meter. NIST-traceable thermocouple calibrators are calibrated annually by an outside laboratory.  Nozzles. Nozzles are measured three (3) times prior to initiating sampling with a caliper. The maximum difference between any two (2) dimensions is 0.004 in.  Digital Calipers. Calipers are calibrated annually by Alliance by using gage blocks that are calibrated annually by an outside laboratory. Site Specific Test Plan Quality Assurance Program AST-2024-4537 Pepperidge – Richmond, UT Page 4-2  Barometer. The barometric pressure is obtained from a nationally recognized agency or a calibrated barometer. Calibrated barometers are checked prior to each field trip against a mercury barometer. The barometer is acceptable if the values agree within ± 2 percent absolute. Barometers not meeting this requirement are adjusted or taken out of service.  Balances and Weights. Balances are calibrated annually by an outside laboratory. A functional check is conducted on the balance each day it is use in the field using a calibration weight. Weights are re-certified every two (2) years by an outside laboratory or internally. If conducted internally, they are weighed on a NIST traceable balance. If the weight does not meet the expected criteria, they are replaced.  Other Equipment. A mass flow controller calibration is conducted on each Environics system annually following the procedures in the Manufacturer’s Operation manual. A methane/ethane penetration factor check is conducted on the total hydrocarbon analyzers equipped with non-methane cutters every six (6) months following the procedures in 40 CFR 60, Subpart JJJJ. Other equipment such as probes, umbilical lines, cold boxes, etc. are routinely maintained and inspected to ensure that they are in good working order. They are repaired or replaced as needed. 4.2 Field Sampling Field sampling will be done in accordance with the Standard Operating Procedures (SOP) for the applicable test method(s). General QC measures for the test program include:  Cleaned glassware and sample train components will be sealed until assembly.  Sample trains will be leak checked before and after each test run.  Appropriate probe, filter and impinger temperatures will be maintained.  The sampling port will be sealed to prevent air from leaking from the port.  Dry gas meter, ΔP, ΔH, temperature and pump vacuum data will be recorded during each sample point.  An isokinetic sampling rate of 90-110% will be maintained, as applicable.  All raw data will be maintained in organized manner.  All raw data will be reviewed on a daily basis for completeness and acceptability. Appendix A Method 1 Data Location Source Project No. Date: in in 0.00 in --in --ft2 --in ft --(must be ≥ 0.5) ft --(must be ≥ 2) -- Measurer (Initial and Date): Reviewer (Initial and Date): 23456789101112 1 25.0 16.7 12.5 10.0 8.3 7.1 6.3 5.6 5.0 4.5 4.2 1 -- -- -- 2 75.0 50.0 37.5 30.0 25.0 21.4 18.8 16.7 15.0 13.6 12.5 2 -- -- -- 3 -- 83.3 62.5 50.0 41.7 35.7 31.3 27.8 25.0 31.8 20.8 3 -- -- -- 4 -- -- 87.5 70.0 58.3 50.0 43.8 38.9 35.0 22.7 29.2 4 -- -- -- 5 -- -- -- 90.0 75.0 64.3 56.3 50.0 45.0 40.9 37.5 5 -- -- -- 6 -- -- -- -- 91.7 78.6 68.8 61.1 55.0 50.0 45.8 6 -- -- -- 7 -- -- -- -- -- 92.9 81.3 72.2 65.0 59.1 54.2 7 -- -- -- 8 -- -- -- -- -- -- 93.8 83.3 75.0 68.2 62.5 8 -- -- -- 9 -- -- -- -- -- -- -- 94.4 85.0 77.3 70.8 9 -- -- -- 10 -- -- -- -- -- -- -- -- 95.0 86.4 79.2 10 -- -- -- 11 -- -- -- -- -- -- -- -- -- 95.5 87.5 11 -- -- -- 12 -- -- -- -- -- -- -- -- -- -- 95.8 12 -- -- -- *Percent of stack diameter from inside wall to traverse point. A = ft. B = ft. Depth of Duct = 0 in. Number of traverse points on a diameter Stack Diagram Cross Sectional Area LOCATION OF TRAVERSE POINTS Traverse Point % of Diameter Distance from inside wall Distance from outside of port Equivalent Diameter: No. of Test Ports: Number of Readings per Point: Distance A: Distance A Duct Diameters: Distance B: Distance B Duct Diameters: Minimum Number of Traverse Points: Actual Number of Traverse Points: DUCT Duct Design: Nipple Length: Depth of Duct: Width of Duct: Cross Sectional Area of Duct: Distance from Far Wall to Outside of Port: Duct Orientation: -- -- -- Stack Parameters Upstream Disturbance Downstream Disturbance BA Appendix B Emissions Calculations Location Source Project No. Run Number Run 1 Run 2 Run 3 Average Date -- -- -- -- Start Time -- -- -- -- Stop Time -- -- -- -- Moisture Fraction, dimensionless BWS -- -- -- -- Volumetric Flow Rate (M1-4), dscfm Qs -- -- -- -- O₂ Concentration, % dry CO₂----- CO₂ Concentration, % dry CCO₂-- -- -- -- THC (as C₃H₈) Concentration, ppmvd CTHC -- -- -- -- THC (as C₃H₈) Concentration, ppmvw CTHCw ----- THC (as C₃H₈) Emission Rate, lb/hr ERTHC -- -- -- -- VOC (as Ethanol) Concentration, ppmvd CVOC -- -- -- -- VOC (as Ethanol) Emission Rate, lb/hr ERVOC -- -- -- -- Input Data - Outlet Calculated Data - Outlet -- - -- -- -- Run 1 - RM Data Location: Source: Project No.: Date: Time O₂ - Outlet CO₂ - Outlet THC - Outlet Unit % dry % dry ppmvw Status Valid Valid Valid Uncorrected Run Average (Cobs)--- Cal Gas Concentration (CMA)#N/A #N/A #N/A Pretest System Zero Response --- Posttest System Zero Response --- Average Zero Response (Co)--- Pretest System Cal Response --- Posttest System Cal Response --- Average Cal Response (CM)--- Corrected Run Average (Corr)--NA - - - - - - - - - - - - - - - - - - - - -- - -- -- -- - Cyclonic Flow Check Location Source Project No. Date Sample Point Angle (ΔP=0) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Average -- -- -- -- Field Data Method 2 Data Location Source Project No. Δ P (in. WC) Ts (°F) Δ P (in. WC) Ts (°F) Δ P (in. WC) Ts (°F) Average Square Root of ΔP, (in. WC)1/2 (ΔP)1/2 -- Average ΔP, in. WC (ΔP)-- Pitot Tube Coefficient (Cp)-- Barometric Pressure, in. Hg (Pb)-- Static Pressure, in. WC (Pg)-- Stack Pressure, in. Hg (Ps)-- Average Temperature, °F (Ts)-- Average Temperature, °R (Ts)-- Measured Moisture Fraction (BWSmsd)-- Moisture Fraction @ Saturation (BWSsat)-- Moisture Fraction (BWS)-- O2 Concentration, % (O2)-- CO2 Concentration, % (CO2)-- Molecular Weight, lb/lb-mole (dry) (Md)-- Molecular Weight, lb/lb-mole (wet) (Ms)-- Velocity, ft/sec (Vs)-- VFR at stack conditions, acfm (Qa)-- VFR at standard conditions, scfh (Qsw)-- VFR at standard conditions, scfm (Qsw)-- VFR at standard conditions, dscfm (Qsd)-- -- -- -- Run No. 1 2 3 Status VALID VALID VALID Date -- -- Stop Time Start Time Traverse Point Leak Check -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- ------ ------ Method 4 Data Location Source Project No. Parameter(s) Console Units / Method ft3 M4 Run No. Date Status Start Time End Time Run Time, min (θ) Meter ID Meter Correction Factor (Y) Orifice Calibration Value (ΔH @) Max Vacuum, in. Hg Post Leak Check, ft3/min (at max vac.) Meter Volume, ft3 Total Meter Volume, ft3 (Vm) Meter Probe Filter Vacuum Imp. Exit Meter Probe Filter Vacuum Imp. Exit Meter Probe Filter Vacuum Imp. Exit -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- Average Temperature, °F (Tm)-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- Average Temperature, °R (Tm)-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- Minimum Temperature, °F -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- Maximum Temperature, °F -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- Barometric Pressure, in. Hg (Pb) Meter Orifice Pressure , in. WC (ΔH) Meter Pressure, in. Hg (Pm) Standard Meter Volume, ft3 (Vmstd) Analysis Type Impinger 1, Pre/Post Test, g -- -- -- -- -- -- -- -- -- Impinger 2, Pre/Post Test, g -- -- -- -- -- -- -- -- -- Impinger 3, Pre/Post Test, g -- -- -- -- -- -- -- -- -- Impinger 4, Pre/Post Test, g -- -- -- -- -- -- -- -- -- Volume Water Collected, mL (Vlc) Standard Water Volume, ft3 (Vwstd) Moisture Fraction Measured (BWS) Gas Molecular Weight, lb/lb-mole (dry) (Md) DGM Calibration Check Value (Yqa) Temperature, °F 0 5 30 35 60 -- -- -- -- 1 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 2 -- 3 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- Gravimetric Gravimetric -- -- -- -- -- -- -- -- -- -- -- -- -- Gravimetric -- 60 0 5 10 15 20 25 10 15 20 25 40 45 50 55 30 35 40 45 50 55 QA Data Location Source Project No. O₂ - Outlet CO₂ - Outlet THC - Outlet Make -- -- -- Model -- -- -- S/N -- -- -- Operating Range -- -- -- Cylinder ID Zero NA NA NA Low NA NA -- Mid -- -- -- High -- -- -- Cylinder Certifed Values Zero NA NA NA Low NA NA -- Mid -- -- -- High -- -- -- Cylinder Expiration Date Zero NA NA NA Low NA NA -- Mid -- -- -- High -- -- -- Type of Sample Line -- Parameter -- - -- -- -- Response Times Location: Source: Project No.: O₂ - Outlet CO₂ - Outlet THC - Outlet Zero -- -- -- Low NA NA -- Mid -- -- -- High -- -- -- Average -- -- -- -- - -- -- -- Parameter Response Times, seconds Calibration Data Location: Source: Project No.: Date: O₂ - Outlet CO₂ - Outlet THC - Outlet Expected Average Concentration -- -- -- Span Between Low -- -- -- High -- -- -- Desired Span -- -- -- Low Range Gas Low NA NA -- High NA NA -- Mid Range Gas Low -- -- -- High -- -- -- High Range Gas Low NA NA -- High NA NA -- Actual Concentration (% or ppm) Zero 0.00 0.00 0.00 Low NA NA -- Mid -- -- -- High -- -- -- Response Time (seconds)-- -- -- Upscale Calibration Gas (CMA)-- -- -- Instrument Response (% or ppm) Zero -- -- -- Low NA NA -- Mid -- -- -- High -- -- -- Performance (% of Span or Cal. Gas Conc.) Zero -- -- 0.00 Low NA NA -- Mid -- -- -- High -- -- 0.00 Status Zero -- -- PASS Low NA NA -- Mid -- -- -- High -- -- PASS -- -- - -- Parameter -- -- Bias/Drift Determinations Location: Source: Project No.: O₂ - Outlet CO₂ - Outlet THC - Outlet Run 1 Date -- Span Value - - - Initial Instrument Zero Cal Response - - - Initial Instrument Upscale Cal Response #N/A #N/A #N/A Pretest System Zero Response - - - Posttest System Zero Response - - - Pretest System Upscale Response - - - Posttest System Upscale Response - - - Bias (%) Pretest Zero -- -- NA Posttest Zero -- -- NA Pretest Span -- -- NA Posttest Span -- -- NA Drift (%) Zero - - - Mid - - - Run 2 Date -- Span Value - - - Instrument Zero Cal Response - - - Instrument Upscale Cal Response #N/A #N/A #N/A Pretest System Zero Response - - - Posttest System Zero Response - - - Pretest System Upscale Response - - - Posttest System Upscale Response - - - Bias (%) Pretest Zero -- -- NA Posttest Zero -- -- NA Pretest Span -- -- NA Posttest Span -- -- NA Drift (%) Zero - - - Mid - - - Run 3 Date -- Span Value - - - Instrument Zero Cal Response - - - Instrument Upscale Cal Response #N/A #N/A #N/A Pretest System Zero Response - - - Posttest System Zero Response - - - Pretest System Upscale Response - - - Posttest System Upscale Response - - - Bias (%) Pretest Zero -- -- NA Posttest Zero -- -- NA Pretest Span -- -- NA Posttest Span -- -- NA Drift (%) Zero - - - Mid - - - Parameter -- - -- -- -- Location: Source: Project No.: Date EPA O2 -- -- -- -- Cylinder Number ID Zero NA Mid -- High -- Cylinder Certified Values Zero 0.0 Mid -- High -- Instrument Response (% or ppm) Zero -- Mid -- High -- Calibration Gas Selection (% of Span) Mid -- High -- Calibration Error Performance (% of Span) Zero -- Mid -- High -- Linearity (% of Range) -- (%) lpm (%) (%) (%) (%) (%) (%) (%)( ± 2 %) 10L/10L* 90.0 7.0 ---- 10L/10L* 80.0 7.0 ---- 10L/5L 80.0 5.0 ---- 10L/5L 50.0 5.0 ---- 10L/1L 20.0 4.0 ---- 10L/1L 10.0 4.0 ---- (%)( ± 2 %)( ± 2 %)( ± 2 %) ---- ---- ---- ---- ---- ---- Mid-Level Supply Gas Calibration Direct to Analyzer Calibration Injection 1 Injection 2 Injection 3 Average Gas Analyzer Analyzer Analyzer Analyzer Concentration Concentration Concentration Concentration Concentration (%) (%) (%) (%) (%) (%)( ± 2 %) - --- Average Analyzer Concentration Injection 1 Error Injection 2 Error Injection 3 Error Difference Average Error *Not all AST Environics Units have 2-10L Mass Flow Controllers. For these units the 90% @ 7lpm and 80% @ 7lpm injections will not be conducted. Cylinder Gas ID (Mid-Level): Cylinder Gas Concentration (Mid-Level), %: Target Mass Flow Contollers Target Dilution Target Flow Rate Target Concentration Actual Concentration Injection 1 Analyzer Concentration Injection 2 Analyzer Concentration Injection 3 Analyzer Concentration Average Analyzer Concentration Difference Average Error Component/Balance Gas: O2/N2 Cylinder Gas ID (Dilution): Cylinder Gas Concentration (Dilution), %: Analyzer Model: -- Analyzer SN: -- Environics ID: -- Analyzer Make: -- -- - -- -- -- Parameter Make Model S/N Span Method Criteria QA Data Location Source Project No. Parameter(s) Date Pitot ID Evidence of damage? Evidence of mis-alignment? Calibration or Repair required? Date Probe or Thermocouple ID Reference Temp. (°F) Indicated Temp. (°F)Difference Criteria -- Date Balance ID: Certified Weight ID: Certified Weight Expiration: Certified Weight (g): Measured Weight (g): Weight Difference (g):-- -- -- -- -- Date Barometric Pressure Evidence of damage?Reading Verified Calibration or Repair required? 0 Reagent Lot#Field Prep performed Field Lot Date By -- -- -- -- ± 1.5 % (absolute) Field Balance Check Pass Barometer ID Date Meter Box ID Positive Pressure Leak Check Location: Source: Project No.: Date: Time O2 CO2 (%) (%) A-1 2 0:00 3 0:00 4 0:00 5 0:00 6 0:00 B-1 0:00 2 0:00 3 0:00 4 0:00 5 0:00 6 0:00 -- -- Single Point Single Point -- - -- -- -- Average Criteria Met Traverse Point