Loading...
HomeMy WebLinkAboutDAQ-2024-010893 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820 Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978 www.deq.utah.gov Printed on 100% recycled paper State of Utah Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF AIR QUALITY Bryce C. Bird Director SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor DAQC-982-24 Site ID 13244 (B1) Nicki Coates TM Crushing, LLC 1450 West 1850 North Lehi, UT 84043 Dear Ms. Coates: Re: TM Crushing, LLC – Temporary Relocation/Operation, Notice of Intent – Salt Lake County Your Notice of Intent dated September 23, 2024, to relocate portable aggregate equipment to the temporary project located at 7328 West New Bingham Highway, West Jordan, UT, was received by the Utah Division of Air Quality (DAQ) and has been reviewed. The following equipment has been approved for operation for this temporary project: Astec Gt206 mobile screen with 160 hp diesel engine Astec FNG 2512KT mobile screen with 99 hp diesel engine Approval is granted to relocate and operate this equipment at the new location for a period not to exceed 180 operational days. As per Utah Administrative Code (UAC) R307-401-17, the operation of equipment at this temporary site may be for up to 180 working days in any calendar year not to exceed 365 consecutive days, starting from the initial relocation date. The operational days per site cannot be extended beyond the stipulated 365 consecutive day period. Approval is subject to the conditions of the dust control plan submitted for this location and the current portable Approval Order (AO) DAQE-AN132440008-18, dated March 22, 2018. Hours of operation shall be held to 15 hours per each 24-hour day. The maximum production rate shall be held to the requested 300 tons per hour. Emissions for this project have been estimated at the following: Pollutant gram/sec lbs/hr lbs/24 hr tons/yr PM10 1.30 10.32 103.23 8.05 SOx 0.48 3.82 38.21 2.98 NOx 3.25 25.76 257.58 20.09 CO 0.87 6.93 69.26 5.40 VOC 0.14 1.10 10.98 0.86 1 , " / Û Û Ù Û Ý DAQC-982-24 Page 2 The owner/operator shall maintain records of the actual operation hours, days, and production rate, of the above referenced equipment at this relocation site and have the ability to submit the information to the DAQ upon the request of representatives of the Director. Please make certain that the plant operator is aware of all the location specific requirements for this site and the conditions of the aforementioned AO. Federal New Source Performance Standards Subpart OOO requires that initial Method 9 observations be performed for all applicable portable crushers, screens, and attached conveyors. Subpart OOO also mandates that all crushers constructed, modified, or reconstructed on or after April 22, 2008, which are not enclosed, must install spray bars on the equipment and keep maintenance records to ensure proper spray bar operations. Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary project. Please refer to Utah DEQ Water Quality’s current Storm Water Construction requirements for additional information. This approval for relocation in no way releases the owner or operator from any liability for compliance with all other applicable federal, state, and local regulations including the UAC. If you have any questions regarding this relocation authorization or the temporary relocation process please contact Susan Weisenberg at (385) 306-6512. Sincerely, Jay P. Morris Assistant Director JPM:SPW:jl Enclosure: Submitted Temporary Relocation Form cc: Salt Lake County Health Department 4 * - - $ . — / @ v A ? A C @ @ w D D ˜ Susan Weisenberg <sweisenberg@utah.gov> Portable/Temporary Relocation Form 1 message noreply@qemailserver.com <noreply@qemailserver.com>Mon, Sep 23, 2024 at 12:57 PM Reply-To: trigger@qemailserver.com To: sweisenberg@utah.gov Susan/Chad: Site # -- TM Crushing has requested a Temporary Relocation. Please see the information below. Any attachments can be access by clicking on the links. Recipient Data: Time Finished: 2024-09-23 12:57:33 MDT IP: 50.239.43.46 ResponseID: R_6hhlZLezd7uo6hm Link to View Results: Click Here URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/Tt1hofpzIbEe7%2Evbdp- 4xn-CbyqMbqXW3TLG7fWfYw24ZhPzzh2tcNT86M4FE7Y4-z1u-T4IDkPCnrftxiS32DF4bj6yDBMHVrW yfIf%2E43pVvuiP8xDw5W40wL%2E6M16X1XeUJgdtFKL8dA8x4IV39RsX965U1LPWsNZ7KY5kA6q7rObDwPgef8ND7- sZ0nGkI0yVwV1XRNUEKuLQ3nHy5O27rWuMLFNd93M3glXv4xUL8YUTtp7wYEbis50% 2Egb7BRuonLhlR1e8r3RyaUb8sqTsnVBZ5K-yvHQVTEQDkA1jrfxZH1lmtg-ABmN6xDj6onmqjCfDKhSp-McoB6FDhZw Response Summary: Please fill out the information below: Contact Person: Nicki Coates Company Name: TM Crushing Mailing Address: 1450 West 1850 N City: Lehi Zip: 84043 Phone Number: 801-425-2539 Email: ncoates@tmcrushing.com Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea... Yes All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo... 7FD5526B95 Briefly give directions to the site and/or physical address: 7328 west New Bingham Highway West Jordan . Utah Proposed Relocation Information: Closest City West Jordan County Salt Lake UTM X Coordinates 40.572423 UTM Y Coordinates -112.075741 Approximate distance to the nearest house/business 2,784.84 ft UTM X Coordinates to nearest house/business 40.56584 UTM Y Coordinates to nearest house/business -112.07963 Does this site currently have a permit with DAQ? 9/30/24, 6:05 PM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1811014335241045137%7Cmsg-f:1811014335241045137&s…1/2 No Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine... 1 Equipment Type Mobile Screen Make/Model Astec Gt206 Serial or ID# unknown Manufactured Date unknown Design Capacity 300 tph 2 Equipment Type Mobile Screen Make/Model Astec FNG 2512KT Serial or ID# unknown Manufactured Date unknown Design Capacity 300 tph Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for... No Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re... Total Hours of operation per 24 hr period 15 Starting time of operation (am/pm) 6:00am Ending time of operation (am/pm) 9:00pm Maximum hourly production rate for project 300tph Expected startup date 09-23-2024 Expected completion date 09-23-2025 What type of application is this for? New Application Owner/Operator Representative: https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_3F2ri56mZCm6t7j 9/30/24, 6:05 PM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1811014335241045137%7Cmsg-f:1811014335241045137&s…2/2 Susan Weisenberg <sweisenberg@utah.gov> RE: diesel information for proposed relocation to West Jordan 1 message Nicki Coates <ncoates@tmcrushing.com>Mon, Sep 30, 2024 at 2:56 PM To: Susan Weisenberg <sweisenberg@utah.gov> Thank you for the clarification the 2512k is 99HP and the Gt206 is 160HP. Nicki From: Susan Weisenberg <sweisenberg@utah.gov> Sent: Monday, September 30, 2024 2:36 PM To: Nicki Coates <ncoates@tmcrushing.com> Subject: Re: diesel informaon for proposed relocaon to West Jordan Hi I apologize for the confusion on this. By rating, I meant the power size, such as hp or kW rating. The current management has asked for the power of all diesel engines. Thanks! Let me know if this still isn't clear. Susan Weisenberg, Environmental Scientist Office: 385-306-6512 On Mon, Sep 30, 2024 at 2:15 PM Nicki Coates <ncoates@tmcrushing.com> wrote: Susan, Sorry for the slow reply we have never been asked for engine ratings on mobile screen for Temporary Relocates before. We are still doing some research but as far as we can tell Astec Gt206 is a Tier II and Astec FNG 2512k is a Tier IV. Thanks Nicki Coates 9/30/24, 6:07 PM State of Utah Mail - RE: diesel information for proposed relocation to West Jordan https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-a:r8366094752184686199%7Cmsg-f:1811655986338738306&…1/3 From: Susan Weisenberg <sweisenberg@utah.gov> Sent: Tuesday, September 24, 2024 4:27 PM To: Nicki Coates <ncoates@tmcrushing.com> Subject: Re: diesel informaon for proposed relocaon to West Jordan Can you tell me what the rating is? Thanks Susan Weisenberg, Environmental Scientist Office: 385-306-6512 On Tue, Sep 24, 2024 at 3:01 PM Nicki Coates <ncoates@tmcrushing.com> wrote: Susan, Both mobile screens have a self-powered engine rating. Let me know if you have any questions. Thanks Nicki Coates From: Susan Weisenberg <sweisenberg@utah.gov> Sent: Tuesday, September 24, 2024 9:47 AM To: Nicki Coates <ncoates@tmcrushing.com> Subject: diesel informaon for proposed relocaon to West Jordan Hello, I received your company's relocation submission to 7328 West New Bingham Highway. The Division of Air Quality is currently requiring information on diesel fired engines on all relocation requests. Please respond to this email stating if the mobile screens have a self-powered engine rating, or if they are powered through a portable generator, or if they will be connected to electrical power. Thanks! Susan Weisenberg, 9/30/24, 6:07 PM State of Utah Mail - RE: diesel information for proposed relocation to West Jordan https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-a:r8366094752184686199%7Cmsg-f:1811655986338738306&…2/3 Environmental Scientist Office: 385-306-6512 9/30/24, 6:07 PM State of Utah Mail - RE: diesel information for proposed relocation to West Jordan https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-a:r8366094752184686199%7Cmsg-f:1811655986338738306&…3/3