HomeMy WebLinkAboutDSHW-2024-008564Site Information Finalized Yes Facility Name Kennecott Utah Copper Smelter Refuse Class IIIb Landfill Facility_ID SW0168 Facility Name Kennecott Utah Copper Smelter Refuse Class IIIb Landfill Street Address 12000 West 2400 South City Magna ZIP Code 84044 County Salt Lake County Inspection Date 10-03-2024 Type of Visit Routine Oversite Is the Visit Announced?Yes 40.016236, -111.734358 Weather Conditions 77 and sunny Inspection Goal To determine compliance with Solid Waste Permitting and Management Rules. Facility Contact Cassady Kristensen, Environmental Business Partner Ryan Evans, Principal Advisor Environmental Ops Participants Alex Milne, DWMRC Corey Buchanan, Environmental Advisor Randy Naeve, Senior Advisor - Environment Follow Up Inspection Needed?N/A Recommended Follow Up Date Depart Office Date 10-03-2024 Depart Office time 07:15 AM (-6 GMT) Return to Office Date 10-03-2024 Return to Office time 03:30 PM (-6 GMT) 1. Pre-Inspection Review 1.1 Permit Review Yes Comment The most recent permit was reviewed. The facility is permitted to accept nonhazardous industrial solid waste incidental to the operations of Kennecotts’s north facilities, including the smelter, refinery, power plant, and molybdenum autoclave process. Waste to is be covered monthly and recorded in a cover log. Waste that is prone to being blown away by wind is to be covered daily. 1.2 Annual Report Review Yes Date Submitted: 10-04-2024 10:58 AM Submitted By: amilne@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 1 of 8 Comment The 2023 Annual Report was reviewed. 100% of waste received is from Salt Lake County. Total Materials Received is noted to be 9,610.00 tons. 1.3 Previous Inspection Review Yes Comment The 11/21/2023 Inspection Report and Inspection Letter were reviewed. The facility was issued Compliance Advisory No. 2311143 for inadequate cover of waste. 1.4 Facility Contacts Confirmed Yes Comment Cassady Kristensen and Ryan Evans are the primary contacts. 1.5 Facility Contacted (If an announced inspection) Yes Comment Cassady Kristensen and Ryan Evans were notified of the inspection via email on 10/01/2024. 1.6 Local Health Contacted Yes Comment Cassady Kristensen and Ryan Evans were notified of the inspection via email on 10/01/2024. 1.7 Other N/A Comment N/A 2. Facility / Operational Controls (1-Good, 5-Poor) 2.1 Litter 5 2.2 Roads 1 2.3 Gate House Operations 5 2.4 Vectors 1 2.5 Communications 1 2.6 Recycling Area NA 2.7 Fugitive Dust Control 1 2.8 Waste Inspection Area 5 2.9 Scavenging Control 1 2.10 Open Burning NA 2.11 Fences, Gates, Locks, Access Control 5 2.12 Working Face 5 2.13 Daily - Soil 5 2.14 Daily - Alternative NA 2.15 Leachate Collection System NA 2.16 Other NA Date Submitted: 10-04-2024 10:58 AM Submitted By: amilne@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 2 of 8 Comment (Required)Uncovered waste beyond the working face was observed. Wind-blown litter is not being covered daily leading to wind-blown litter scattered beyond the working face. The facility does not restrict landfill access and no security controls are in place. The signage currently present is not adequate. 3. Signs Required / Properly Posted 3.1 Operating Days / Hours No 3.2 Directions & Procedures Yes 3.3 Emergency Numbers No 3.4 List of Unacceptable Materials No 3.5 Other N/A Comment (Required)The signage observed is inadequate. An emergency number is not provided and a list of unacceptable materials is not noted. The signage includes instructions in landfill access, however, due to the lack of security controls in place, unauthorized access cannot be prevented. 4. Operator / Representative / Employees 4.1 On-site While Open No 4.2 Training No 4.3 Other N/A Comment (Required)Training records were not provided. The landfill is not properly secured and no operator was observed at the time of the inspection. 5. Monitoring 5.1 Methane N/A 5.2 Random Inspections N/A 5.3 Leachate N/A 5.4 Ground Water N/A 5.5 Other N/A Comment (Required)The facility does not have groundwater or gas monitoring requirements. 6. Drainage / Erosion 6.1 Water Run-on No 6.2 Water Run-off No 6.3 Other N/A Comment (Required)Steep slopes with erosion channels were observed that could potentially expose covered waste. 7. Proper Storage / Isolation / Disposal 7.1 Special Waste N/A 7.2 Batteries N/A Date Submitted: 10-04-2024 10:58 AM Submitted By: amilne@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 3 of 8 7.3 Hazardous Waste N/A 7.4 Infectious Waste N/A 7.6 Dead Animals N/A 7.7 Asbestos N/A 7.8 Bulky Waste N/A 7.9 Contaminated Soil N/A 7.10 Ash N/A 7.11 Sludge N/A 7.12 Other Yes Comment (Required)The facility is permitted to accept nonhazardous industrial waste. Only acceptable waste was observed. 8. Cover 8.1 Intermediate No 8.2 Final N/A 8.3 Vegetation N/A 8.4 Other N/A Comment (Required)Uncovered waste beyond the working face was observed. Waste prone to being wind-blown is not covered with six inches of earthen cover at the end of the day it was received. The facility does not maintain a cover log as required by the Permit. 9. Inspection Records 9.1 Random Inspection Report No 9.2 Gas Monitoring System N/A 9.3 Surface Drainage Control N/A 9.4 Daily Records Yes 9.5 Weight or Volumes No 9.6 Intermediate Cover N/A 9.7 Final Cover N/A 9.8 Self Inspection (Quarterly Reports) Yes 9.9 Deviation From Plans No 9.10 Permit, Permit Application, and Rules Available Yes 9.11 Other N/A Date Submitted: 10-04-2024 10:58 AM Submitted By: amilne@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 4 of 8 Comment (Required)Minimal records were provided by the facility. Quarterly inspection reports were not provided. The facility did provide weekly inspection reports. The weekly inspection reports did not have line items verifying security controls are in place. Training records were not provided and random load inspection reports were not provided. The facility provided records demonstrating dates of waste acceptance and a description of where the waste originated from. Descriptions of waste types are not documented within the records. The facility does not maintain a cover log as required by the Permit. The facility did not provide records documenting deviations from the Plan of Operation such as not covering waste. 10. Monitoring / Sampling / Analysis Records 10.1 Explosive Gas Monitoring N/A 10.2 Leachate Sampling & Treatment N/A 10.3 Ground Water Sampling Results N/A 10.4 Other N/A Comment (Required)The facility does not have groundwater or gas monitoring requirements. 11. Special Waste Records 11.1 Lab Analysis Results N/A 11.2 Manifests N/A 11.3 Treatment Certification N/A 11.4 Paint Filter Test Results N/A 11.5 Onsite Treatment Documentation N/A 11.6 Other N/A Comment (Required)The facility is not permitted to accept special waste. 12. Waste Tires 12.1 Acceptance procedures for Waste Tires N/A 12.2 Waste Tire Pile Segregated N/A 12.3 Estimated Quanitity of Waste Tires No Number of Tires 12.4 Waste Tire Fund Training N/A Comment (Required)The facility is not permitted to accept waste tires. 13 Other Items 13.1 Notice of Inspections Form Completed and Signed N/A 13.2 N/A Date Submitted: 10-04-2024 10:58 AM Submitted By: amilne@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 5 of 8 13.3 N/A 13.4 N/A Comment (Required)N/A 14. Special Permit Requirements 14.1 N/A 14.2 N/A 14.3 N/A Comment (Required)N/A General Comments Comments The facility is not secured and does not have adequate signage. Uncovered waste beyond the working face was observed. Waste prone to being wind- blown is not being covered by the end of the day it is received. However, the facility promptly covered the waste. Due to inadequate cover, wind- blown litter was observed beyond the working face. The facility does not maintain adequate records such as a cover log, random load inspections, deviations from the Plan of Operations, etc. Steep slopes with erosion channels were observed that could potentially expose covered waste. DWMRC Inspector Signature DWMRC Inspector Name Alex Milne Date/Time 10-04-2024 Photos Attach Photos View of the entrance to the landfill. Access is not controlled and no gates were observed. Date Submitted: 10-04-2024 10:58 AM Submitted By: amilne@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 6 of 8 The landfill consists of two working faces. Waste subject to being wind-blown is not covered by the end of the day it is received. This issue has been resolved and the waste is now covered. Uncovered waste was observed beyond the working face. View of uncovered waste beyond the working face. Asphalt is not considered inert waste and must be treated as a solid waste. Additional view of uncovered waste. Documentation was not provided demonstrating when this waste was received. Date Submitted: 10-04-2024 10:58 AM Submitted By: amilne@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 7 of 8 View of uncovered waste. Waste subject to being wind-blown was not covered by the end of the day the waste was received. This issue has now been resolved and the waste is covered. View of wind-blown litter observed beyond the working face. Additional view of uncovered waste in the background. Date Submitted: 10-04-2024 10:58 AM Submitted By: amilne@utah.gov Solid Waste Program Facility Inspection Report Checklist Page 8 of 8