Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DERR-2024-011152
Annual Sump Inspection IMPACT VALVE LEAK DETECTOR Line Tightness Test MONITOR CERTIFICATION SPILL BUCKET TEST STAGE I SURVEY 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 9/26/2024 UTAH DEPARTMENT OF ENV. QUALITY UST PO Box 144840 SALT LAKE CITY, UT 84114 Test Date: 9/23/2024 Order Number: 2371454 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: WAL-MART #1572 (WM1572) 1851 W HIGHWAY 40 VERNAL, UT 84078 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting Product Line Tightness Test Page 1 of 1 Work Order: 2371454 Date: 9/23/2024 Site Name/ID: WAL-MART #1572 / WM1572 Address: 1851 W HIGHWAY 40 City: VERNAL State: UT Zip: 84078 Tank Information Test Method Customer Tank ID Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Tank # 1 Line # 1 TLD-1 T1 Regular UNLEADED Pressure 60 00:11 01:11 0.00 Pass Yes Tank # 1 Line # 2 TLD-1 T1 Regular UNLEADED Pressure 60 11:00 12:00 0.00 Pass Yes Tank # 2 Line # 1 TLD-1 T2 Premium PREMIUM Pressure 60 11:00 12:00 0.00 Pass Yes Tank # 2 Line # 2 TLD-1 T2 Premium PREMIUM Pressure 60 11:00 12:00 0.00 Pass Yes Tank # 3 Line # 1 TLD-1 T3 Diesel Low Sulfur Diesel Pressure 60 11:00 12:00 0.00 Pass Yes Tank # Line # Technician Comments: ut151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com WAL-MART #1572 1851 W HIGHWAY 40 VERNAL UT 84078 WM1572 Tanknology, Inc. WALMART/SAM'S CLUB DEPT. 9641 2101 SE Simple Savings Dr. BENTONVILLE AR 72716 479-360-2779 09/23/2024 UNLEADED PREMIUM Veeder Root FX1V Veeder Root FX1V Veeder Root FX1DV 38 20 150 3 10 4 33 20 150 3 10 4 32 20 130 2 10 3 ut151 David Mathie NW1-2371454 Low Sulfur Diesel TT1 Regular:1 TT2 Premium:1 TT3 Diesel:1 Impact Valve Inspection Impact Valve Operational Inspection Work Order:2371454 Date:9/23/2024 Site Name/ID:WAL-MART #1572 Address:1851 W HIGHWAY 40 City:VERNAL State:UT Zip:84078 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 40 Pass Fail Not Tested 1/2 85 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 85 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 85 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 85 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested 9/10 85 Pass Fail Not Tested 9/10 91 Pass Fail Not Tested 11/12 40 Pass Fail Not Tested 11/12 85 Pass Fail Not Tested 11/12 91 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com WAL-MART #1572 WALMART/SAM'S CLUB 1851 W HIGHWAY 40 VERNAL UT 84078 WM1572 Tanknology, Inc. DEPT. 9641 2101 SE Simple Savings Dr. BENTONVILLE AR 72716 479-360-2779 800-964-1250 09/23/2024 1 2 3 RUL PREM DSL VR450PLUS VR450PLUS VR450PLUS 19782 11904 7901 118.4 118..4 118.4 UT151 David Mathie 1851 W HIGHWAY 40 WAL-MART #1572 1851 W HIGHWAY 40, VERNAL, UT 84078 WM1572 Tanknology, Inc. WALMART/SAM'S CLUB DEPT. 9641 2101 SE Simple Savings Dr. BENTONVILLE, AR 72716 479-360-2779 09/23/2024 ANNULAR ANNULAR STP STP STP UDC UDC RUL PREM/DSL RUL PREM DSL 1/2 3/4 UT151 David Mathie 1851 W HIGHWAY 40 WAL-MART #1572 1851 W HIGHWAY 40, VERNAL, UT 84078 WM1572 Tanknology, Inc. WALMART/SAM'S CLUB DEPT. 9641 2101 SE Simple Savings Dr. BENTONVILLE, AR 72716 479-360-2779 09/23/2024 UDC UDC UDC UDC 5/6 7/8 9/10 11/12 UT151 David Mathie WAL-MART #1572 1851 W HIGHWAY 40 VERNAL, UT 84078 WM1572 Tanknology, Inc. WALMART/SAM'S CLUB 479-360-2779 09/23/2024 DEPT. 9641 2101 SE Simple Savings Dr. BENTONVILLE, AR 72716 1 RUL 5 OPW 2 PREM 5 OPW 3 DSL 5 OPW 15WC 1044 14WC 1049 5 MIN 1 15WC 1051 14WC 1056 5MIN 1 1058 15WC 1103 15WC 5MIN 0 UT151 David Mathie Stage I Vapor System Survey Survey to determine compliance with Requirements of Title 40 Part 63 National Emission Standards for Hazardous Air Pollutants for Source Categories Survey Date 9/23/2024 Work Order 2371454 Cust Name / Location Number WM1572 Street Address 1851 W HIGHWAY 40 City, State, ZipCode VERNAL UT 84078 Product Stage I Type Drop Tubes Type Drop Tubes Max inches from tank Bottom Fill Adapters Type Vapor Adapters Type NESHAP Work Required? Vent Caps Type Labeled Positive Cracking Pressure Labeled Negative Cracking Pressure T1 Regular UNLEADED Dual Point Straight w/ Flapper 5.75 Swivel Swivel (poppet) No GAS Pressure Vacuum cap 3 8 T2 Premium PREMIUM Dual Point Straight w/ Flapper 5.75 Swivel Swivel (poppet) No Describe Work Required Surveyed by Signature ANNUAL CONTAINMENT SUMP INSPECTION This form may be utilized to document the inspection of containment sumps. Date of Inspection 9/23/2024 UST Facility Person Conducting Test Facility Name WAL-MART #1572 Facility ID # WM1572 Tester's Name DMATHIE Physical Address 1851 W HIGHWAY 40 Company Tanknology Inc. City VERNAL County UINTAH State UT Certification # 41442 Expiration Date 10/20/2025 UST Owner WALMART/SAM'S CLUB Tester's Signature Date 9/23/2024 Containment Sump Inspection Sump Material of Construction Fiberglass Reinforced Plastic Thermoplastic Steel Composite Containment Sump Inspection Procedure 1. Clean-out and properly dispose of all debris, soil and/or fluids from the containment sump. 2. Visually examine the containment sump to ensure there are no cracks, holes, deteriorated seals, deformation or other indications that the sump is not liquid tight. 3. If the sump appears to be liquid tight and no water was in the sump, the inspection result is "pass" and no further action is required. 4. If the sump appears to be liquid tight but water was present within the sump, the inspection result is "fail". 5. If there is visual evidence that the sump is not liquid tight, then repair or replacement (see note below) of the sump is required. Inspection Results for the Year 2024 Sump ID (product stored for STP or dispenser number) Sump lid/gasket in good condition (yes/no) Sump is dry (yes/no) All penetration fittings in good condition (yes/no) Sump walls/bottom in good condition (yes/no) Are there any leaks from pipe components (yes/no) Inspection Result (Pass/Fail) STP:T1 Regular UNLEADED - 1 Y Y Y Y N Pass STP:T2 Premium PREMIUM - 1 Y Y Y Y N Pass STP:T3 Diesel Low Sulfur Diesel - 1 Y Y Y Y N Pass Comments: WO: 2371454 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2371454 Site ID / Name:WM1572 / WAL-MART #1572 Address:1851 W HIGHWAY 40 City:VERNAL State:UT Zip:84078