Loading...
HomeMy WebLinkAboutDDW-2024-011676Sanitary Survey - Deficiency Report PWS Number:UTAH25188 Deficiency Points:400 Survey Date:09/25/2024 Survey Name:TINTIC CONSOLIDATED WATER SYSTEM Surveyor:Ryan Dearing Sanitary Survey Category: SM SDWIS Severity Code: Recommendation Management and Operations | DS001 | UTAH25188 DISTRIBUTION SYSTEM 31. Does your water system have an Emergency Response Plan? Rule: R309-105-18 All suppliers are advised to develop contingency plans to cope with possible emergency situations. In many areas of the state the possibility of earthquake damage shall be realistically considered. Notes: Deficiency Points: 0 Days until points become effective on IPS: 0 SDWIS Deficiency Description: M001 NO CURRENT EMERGENCY RESPONSE PROGRAM Sanitary Survey Category: FW SDWIS Severity Code: Minor Deficiency Storage Tanks | ST001 | TINTIC CONSOLIDATED TANK #1 (BURGIN) 62A. Access opening framed at least 4 inches above roof surface or 18 inches above earthen cover. Rule: R309-545-14(1)Rule requires tank access opening to be framed at least 4 inches above the surface of the roof, or on a buried tank, to be at least 18 inches above any earthen cover over the tank. Notes:Tank is plastic with a threaded lid. Would recommend requesting an exception as retrofit with a hatch would be problematic. The tanks are located inside a building. Deficiency Points: 15 Days until points become effective on IPS: 0 SDWIS Deficiency Description: V008 TANK ACCESS HEIGHT LESS THAN 4 INCHES ABOVE TANK ROOF OR LESS THAN 18 INCHES ABOVE EARTHEN COVER Sanitary Survey Category: FW SDWIS Severity Code: Significant Deficiency Storage Tanks | ST001 | TINTIC CONSOLIDATED TANK #1 (BURGIN) 62B. Access opening shoe box type with at least 2 inches of overlap Rule: R309-545-14(2)Rule requires the frame of an access opening to be provided with a close fitting solid shoebox type cover which extends down around the frame at least two inches and is furnished with a gasket(s) between the lid and frame. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Tank is plastic with a threaded lid. Would recommend requesting an exception as retrofit with a hatch would be problematic. The tanks are located inside a building. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: V010 STORAGE TANK LID NOT SHOEBOX STYLE Sanitary Survey Category: FW SDWIS Severity Code: Significant Deficiency Storage Tanks | ST001 | TINTIC CONSOLIDATED TANK #1 (BURGIN) 62C. Access opening lid properly gasketed Rule: R309-545-14(2)Rule requires the access opening to a tank to be furnished with a gasket between the lid and frame. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Tank is plastic with a threaded lid. Would recommend requesting an exception as retrofit with a hatch would be problematic. Would also recommend adding an O-ring to the lid. The tanks are located inside a building. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: V009 STORAGE TANK LID LACKS A FUNCTIONING GASKET BETWEEN THE LID AND FRAME Sanitary Survey Category: FW SDWIS Severity Code: Minor Deficiency Storage Tanks | ST002 | TINTIC CONSOLIDATED TANK #2 (BURGIN) 76A. Access opening framed at least 4 inches above roof surface or 18 inches above earthen cover. Rule: R309-545-14(1)Rule requires tank access opening to be framed at least 4 inches above the surface of the roof, or on a buried tank, to be at least 18 inches above any earthen cover over the tank. Notes:Tank is plastic with a threaded lid. Would recommend requesting an exception as retrofit with a hatch would be problematic. The tanks are located inside a building. Deficiency Points: 15 Days until points become effective on IPS: 0 SDWIS Deficiency Description: V008 TANK ACCESS HEIGHT LESS THAN 4 INCHES ABOVE TANK ROOF OR LESS THAN 18 INCHES ABOVE EARTHEN COVER Sanitary Survey Category: FW SDWIS Severity Code: Significant Deficiency Storage Tanks | ST002 | TINTIC CONSOLIDATED TANK #2 (BURGIN) 76B. Access opening shoe box type with at least 2 inches of overlap Rule: R309-545-14(2)Rule requires the frame of an access opening to be provided with a close fitting solid shoebox type cover which extends down around the frame at least two inches and is furnished with a gasket(s) between the lid and frame. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Tank is plastic with a threaded lid. Would recommend requesting an exception as retrofit with a hatch would be problematic. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: V010 STORAGE TANK LID NOT SHOEBOX STYLE Sanitary Survey Category: FW SDWIS Severity Code: Significant Deficiency Storage Tanks | ST002 | TINTIC CONSOLIDATED TANK #2 (BURGIN) 76C. Access opening lid properly gasketed Rule: R309-545-14(2)Rule requires the access opening to a tank to be furnished with a gasket between the lid and frame. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Tank is plastic with a threaded lid. Would recommend requesting an exception as retrofit with a hatch would be problematic. Would also recommend adding an O-ring. The tanks are located inside a building. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: V009 STORAGE TANK LID LACKS A FUNCTIONING GASKET BETWEEN THE LID AND FRAME Sanitary Survey Category: FW SDWIS Severity Code: Minor Deficiency Storage Tanks | ST003 | TINTIC CONSOLIDATED TANK #3 (DRILL SHOP) 90A. Access opening framed at least 4 inches above roof surface or 18 inches above earthen cover. Rule: R309-545-14(1)Rule requires tank access opening to be framed at least 4 inches above the surface of the roof, or on a buried tank, to be at least 18 inches above any earthen cover over the tank. Notes:Tank is plastic with a threaded lid. Would recommend requesting an exception as retrofit with a hatch would be problematic. Deficiency Points: 15 Days until points become effective on IPS: 0 SDWIS Deficiency Description: V008 TANK ACCESS HEIGHT LESS THAN 4 INCHES ABOVE TANK ROOF OR LESS THAN 18 INCHES ABOVE EARTHEN COVER Sanitary Survey Category: FW SDWIS Severity Code: Significant Deficiency Storage Tanks | ST003 | TINTIC CONSOLIDATED TANK #3 (DRILL SHOP) 90B. Access opening shoe box type with at least 2 inches of overlap Rule: R309-545-14(2)Rule requires the frame of an access opening to be provided with a close fitting solid shoebox type cover which extends down around the frame at least two inches and is furnished with a gasket(s) between the lid and frame. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Tank is plastic with a threaded lid. Would recommend requesting an exception as retrofit with a hatch would be problematic. The tanks are located inside a building. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: V010 STORAGE TANK LID NOT SHOEBOX STYLE Sanitary Survey Category: FW SDWIS Severity Code: Significant Deficiency Storage Tanks | ST003 | TINTIC CONSOLIDATED TANK #3 (DRILL SHOP) 90C. Access opening lid properly gasketed Rule: R309-545-14(2)Rule requires the access opening to a tank to be furnished with a gasket between the lid and frame. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Tank is plastic with a threaded lid. Would recommend requesting an exception as retrofit with a hatch would be problematic. Would reccomend adding an O-ring. The tanks are located inside a building. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: V009 STORAGE TANK LID LACKS A FUNCTIONING GASKET BETWEEN THE LID AND FRAME Sanitary Survey Category: FW SDWIS Severity Code: Minor Deficiency Storage Tanks | ST004 | TINTIC CONSOLIDATED TANK #4 (TRIXIE) 104A. Access opening framed at least 4 inches above roof surface or 18 inches above earthen cover. Rule: R309-545-14(1)Rule requires tank access opening to be framed at least 4 inches above the surface of the roof, or on a buried tank, to be at least 18 inches above any earthen cover over the tank. Notes:Tank is plastic with a threaded lid. Would recommend requesting an exception as retrofit with a hatch would be problematic. The tanks are located inside a building. Deficiency Points: 15 Days until points become effective on IPS: 0 SDWIS Deficiency Description: V008 TANK ACCESS HEIGHT LESS THAN 4 INCHES ABOVE TANK ROOF OR LESS THAN 18 INCHES ABOVE EARTHEN COVER Sanitary Survey Category: FW SDWIS Severity Code: Significant Deficiency Storage Tanks | ST004 | TINTIC CONSOLIDATED TANK #4 (TRIXIE) 104B. Access opening shoe box type with at least 2 inches of overlap Rule: R309-545-14(2)Rule requires the frame of an access opening to be provided with a close fitting solid shoebox type cover which extends down around the frame at least two inches and is furnished with a gasket(s) between the lid and frame. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Tank is plastic with a threaded lid. Would recommend requesting an exception as retrofit with a hatch would be problematic. The tanks are located inside a building. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: V010 STORAGE TANK LID NOT SHOEBOX STYLE Sanitary Survey Category: FW SDWIS Severity Code: Significant Deficiency Storage Tanks | ST004 | TINTIC CONSOLIDATED TANK #4 (TRIXIE) 104C. Access opening lid properly gasketed Rule: R309-545-14(2)Rule requires the access opening to a tank to be furnished with a gasket between the lid and frame. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Tank is plastic with a threaded lid. Would recommend requesting an exception as retrofit with a hatch would be problematic. Would reccomend adding an O-ring. The tanks are located inside a building. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: V009 STORAGE TANK LID LACKS A FUNCTIONING GASKET BETWEEN THE LID AND FRAME Sanitary Survey Category: FW SDWIS Severity Code: Minor Deficiency Storage Tanks | ST005 | TINTIC CONSOLIDATED TANK #5 (TRIXIE) 118A. Access opening framed at least 4 inches above roof surface or 18 inches above earthen cover. Rule: R309-545-14(1)Rule requires tank access opening to be framed at least 4 inches above the surface of the roof, or on a buried tank, to be at least 18 inches above any earthen cover over the tank. Notes:Tank is plastic with a threaded lid. Would recommend requesting an exception as retrofit with a hatch would be problematic. The tanks are located inside a building. Deficiency Points: 15 Days until points become effective on IPS: 0 SDWIS Deficiency Description: V008 TANK ACCESS HEIGHT LESS THAN 4 INCHES ABOVE TANK ROOF OR LESS THAN 18 INCHES ABOVE EARTHEN COVER Sanitary Survey Category: FW SDWIS Severity Code: Significant Deficiency Storage Tanks | ST005 | TINTIC CONSOLIDATED TANK #5 (TRIXIE) 118B. Access opening shoe box type with at least 2 inches of overlap Rule: R309-545-14(2)Rule requires the frame of an access opening to be provided with a close fitting solid shoebox type cover which extends down around the frame at least two inches and is furnished with a gasket(s) between the lid and frame. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Tank is plastic with a threaded lid. Would recommend requesting an exception as retrofit with a hatch would be problematic. The tanks are located inside a building. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: V010 STORAGE TANK LID NOT SHOEBOX STYLE Sanitary Survey Category: FW SDWIS Severity Code: Significant Deficiency Storage Tanks | ST005 | TINTIC CONSOLIDATED TANK #5 (TRIXIE) 118C. Access opening lid properly gasketed Rule: R309-545-14(2)Rule requires the access opening to a tank to be furnished with a gasket between the lid and frame. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Tank is plastic with a threaded lid. Would recommend requesting an exception as retrofit with a hatch would be problematic. The tanks are located inside a building. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: V009 STORAGE TANK LID LACKS A FUNCTIONING GASKET BETWEEN THE LID AND FRAME Sanitary Survey Category: PU SDWIS Severity Code: Significant Deficiency Pump Stations | PF001 | BURGIN PUMP STATION 141. If the pump station is used to pressurize the distribution system, does it have at least two functioning pumping units? ... if yes, answer the following question(s) Rule: R309-540-5(4)(b)Rule states inline booster pumps, withdrawing water directly from distribution lines without storage and feeding water directly into distribution lines, shall have at least two pumping units. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Only one pump. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: PS18 IN-LINE BOOSTER PUMP STATION LACKS REDUNDANCY TO MEET PEAK DEMAND WITH ONE PUMP OUT OF SERVICE Sanitary Survey Category: PU SDWIS Severity Code: Significant Deficiency Pump Stations | PF002 | DRILL SHOP PUMP STATION 150. If the pump station is used to pressurize the distribution system, does it have at least two functioning pumping units? ... if yes, answer the following question(s) Rule: R309-540-5(4)(b)Rule states inline booster pumps, withdrawing water directly from distribution lines without storage and feeding water directly into distribution lines, shall have at least two pumping units. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Only one pump. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: PS18 IN-LINE BOOSTER PUMP STATION LACKS REDUNDANCY TO MEET PEAK DEMAND WITH ONE PUMP OUT OF SERVICE Sanitary Survey Category: PU SDWIS Severity Code: Significant Deficiency Pump Stations | PF003 | TRIXIE PUMP STATION 159. If the pump station is used to pressurize the distribution system, does it have at least two functioning pumping units? ... if yes, answer the following question(s) Rule: R309-540-5(4)(b)Rule states inline booster pumps, withdrawing water directly from distribution lines without storage and feeding water directly into distribution lines, shall have at least two pumping units. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Only one pump. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: PS18 IN-LINE BOOSTER PUMP STATION LACKS REDUNDANCY TO MEET PEAK DEMAND WITH ONE PUMP OUT OF SERVICE