Loading...
HomeMy WebLinkAboutDDW-2024-011485Estimate Disinfection CT & Whether Meeting 4-Log Virus Inactivation Estimate Pipe Volume V=L*Pi*(R)2 Pipe Description Length (ft)Diameter (inches) Diameter (feet)Volume (ft3)Volume (gal)% Full Effective Water Volume (gal) CT Pipe (12-inch)0 12.000 1.00 0.0 0.0 100%0.0 CT Pipe (2-inch)0 2.00 0.17 0.0 0.0 100%0.0 0.00 0.0 0.0 100%0.0 0.00 0.0 0.0 100%0.0 0.00 0.0 0.0 0.0 0.00 0.0 0.0 0.0 0.00 0.0 0.0 0.0 0.0 Estimate Pipe Disinfection CT Residual Conc., C (mg/L) 1 pH 2 Temp. (°C) 3 (See Table B below) Peak Flow (gpm) Effective Volume (gal) Total Detention Time (min) Contact Time (T) (min) Total Pipe CT (C*T) 4 2 6-9 0.5 24.0 0.0 0.0 0.0 0.0 Estimate Storage Tank Volume & Disinfection CT Tank Description Residual Conc., C (mg/L) pH 2 Temp. (°C) 3 (See Table B below) Peak Flow (gpm) Baffling Factor, BF (See Table A below) Minimum Volume (gal) (at lowest setting) Total Detention Time, TDT (min) Contact Time (T) (min) CT (C*T) Vol/Peak Flow TDT x BF C*T Mix Master Tank 2 6-9 0.5 24.0 0.6 160 6.7 4.0 8.0 6-9 0.5 1.0 0.0 0.0 0.0 6-9 0.5 1.0 0.0 0.0 0.0 6-9 0.5 1.0 0.0 0.0 0.0 6-9 0.5 1.0 0.0 0.0 0.0 6-9 0.5 1.0 0.0 0.0 0.0 8.0 Summary 6 (See Table B below, assuming worst scenario) 8.0 (= Total Pipe CT + Total Tank CT) Yes Notes: 1. Residual conc. is the disinfectant level measured at (or after) the end of the pipe/vessel [NOT the dose added at the beginning of the pipe/vessel]. 2. Assuming pH between 6 and 9 3. Assuming water temperature of 0.5 °C in winter worst scenario 4. This tool provides rough estimate of disinfection CT. For detailed design, apply additional safety factor and other design considerations. Factor 6-9 10 0.5 12 90 5 8 60 10 6 45 15 4 30 20 3 22 25 2 15 Enter only the green field CT Req'd for 4-Log Virus Inactivation Perforated inlet baffle, serpentine or perforated intra-basin baffles, outlet weir or perforated launders 0.1 Total Pipe Effecive Volume (gallons) pHTemp (oC) Total Estimated Disinfection CT 4 Meeting 4-Log Virus Inactivation? None, agitated basin, very low length to width ratio, high inlet/outlet velocities Total Tank CT 4 Penny's Café Water System #23075 File # Very high L to W ratio (pipeline flow), perforated inlet, outlet & intra-basin baffles 4- Log Inactivation of VirusesDescription Table A Tank Baffling Factors 0.7 1 0.3 0.5 Single or mutliple unbaffled inlets or outlets, no intra-basin baffles Baffled inlet/outlet with some intra-basin baffling Table B Free Chlorine CT Values (per EPA, 1991) DDW-Eng-0031 1 5/13/2016