Loading...
HomeMy WebLinkAboutDAQ-2024-010448 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820 Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978 www.deq.utah.gov Printed on 100% recycled paper State of Utah Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF AIR QUALITY Bryce C. Bird Director SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor DAQC-948-24 Site ID 13267 (B1) Jeffery Cowlishaw Staker Parson Companies 2350 South 1900 West Ogden, UT 84401 Dear Mr. Cowlishaw: Re: Staker Parson Companies – Temporary Relocation/Operation, Notice of Intent – Duchesne County Your Notice of Intent dated September 10, 2024, to relocate portable asphalt and crushing equipment to the temporary project located north on UT-87 from Main Street in Duchesne for 1.2 miles, turning east on 8300 South, Duchesne County, UT, was received by the Utah Division of Air Quality (DAQ) and has been reviewed. The following equipment has been approved for operation for this temporary project: Gencor hot mix plant Pioneer 500 TPH jaw crusher Two (2) JCI 500 TPH cone crushers Three (3) 7x20 screens Kohler 810 kW generator Whisperwatt 40 kW generator Caterpillar 3508 kW generator This equipment has been permitted for portable operation in the State of Utah by the portable Approval Order (AO) DAQE-AN132670009-21, dated April 7, 2021. Approval is granted to relocate and operate this equipment at the new location for a period not to exceed 180 operational days. As per Utah Administrative Code (UAC) R307-401-17, the operation of equipment at this temporary site may be for up to 180 working days in any calendar year not to exceed 365 consecutive days, starting from the initial relocation date. Approval is subject to the conditions of the dust control plan submitted for this location and the above portable AO. " - 1 " * " / Û à Û Ù Û Ý DAQC-948-24 Page 2 Hours of operation for this equipment shall be held to 16 hours each day. The maximum production rate for aggregate production shall be held to the requested 500 tons per hour. Emissions for the aggregate portion of this project have been estimated at the following: Pollutant gram/sec lbs/hr lbs/24 hr tons/yr PM10 1.97 15.67 156.71 12.22 SOx 0.78 6.16 61.56 4.80 NOx 5.15 40.91 409.11 31.91 CO 1.36 10.75 107.54 8.39 VOC 0.21 1.68 16.83 1.31 As per State Administrative Rule R307-165-4, the production rate for the asphalt plant shall be held to 110% of the production rate of the last successful stack test for this plant, which is 194 tons per hour. Emissions for the asphalt production portion of this project have been estimated at the following: Pollutant gram/sec lbs/hr lbs/24 hr tons/yr PM10 1.143 9.072 90.722 7.08 SO2 0.028 0.219 2.188 0.17 NOx 1.109 8.801 88.013 6.87 CO 0.998 7.922 79.220 6.18 VOC 0.715 5.672 56.724 4.42 Please be aware that the State of Utah requires that your company’s permitted asphalt plants must be tested every three years or sooner if required by the Director. The stack test shall be conducted as per the applicable conditions of the above portable AO. A stack testing protocol must be submitted to the DAQ at least 30 days prior to the performance of the test. The owner/operator shall maintain records of the actual operation hours, days, and production rate, of the above referenced equipment at this relocation site and have the ability to submit the information to the DAQ upon the request of representatives of the Director. Please make certain that the plant operator is aware of all the location specific requirements for this site and the conditions of the aforementioned AO. Federal New Source Performance Standards Subpart OOO requires that initial Method 9 observations be performed for all applicable portable crushers, screens, and attached conveyors. Subpart OOO also mandates that all crushers constructed, modified, or reconstructed on or after April 22, 2008, which are not enclosed, must install spray bars on the equipment and keep maintenance records to ensure proper spray bar operations. Utah Division of Water Quality Storm Water Permits and regulations may apply to this temporary project. Please refer to Utah DEQ Water Quality’s current Storm Water Construction requirements for additional information. DAQC-948-24 Page 3 This approval for relocation in no way releases the owner or operator from any liability for compliance with all other applicable federal, state, and local regulations including the UAC. If you have any questions regarding this relocation authorization or the temporary relocation process please contact Susan Weisenberg at (385) 306-6512. Sincerely, Jay P. Morris Assistant Director JPM:SPW:jl Enclosure: Submitted Temporary Relocation Form cc: TriCounty Health Department 4 * - - $ . — + A D v A ? A C @ F w @ ? ˜ Susan Weisenberg <sweisenberg@utah.gov> Portable/Temporary Relocation Form 1 message noreply@qemailserver.com <noreply@qemailserver.com>Tue, Sep 10, 2024 at 11:41 AM Reply-To: trigger@qemailserver.com To: sweisenberg@utah.gov Susan/Chad: Site # -- Staker Parson Companies has requested a Temporary Relocation. Please see the information below. Any attachments can be access by clicking on the links. Recipient Data: Time Finished: 2024-09-10 11:41:48 MDT IP: 165.225.10.85 ResponseID: R_6MFHWYDalks9bd7 Link to View Results: Click Here URL to View Results: https://utahgov.iad1.qualtrics.com/apps/single-response-reports/reports/ 2pXH2BRaXdn9ZuX5IdTUHU0UkZ2I1dJ2hKMcpdVve4xqNBGL50RYTEmrsqLkEpkQTnzM2g90BT3bQ2asPQZ3HFKbi- lfGe0UCAMCNRV%2E4nSSyfgHb3QNx4RcSJ6ysbiL7zNp2pauoSGi7%2EHcNy5Zx7Ogof0xrAKDhxku7VQtjR LlICWs3UdruFRw-2ToN7ZU2BTmpTeTGx4fruQNjtpO2Roo0y9-8yAABTi0NSEBdfvTmU-8O-DkfMKm4in5% 2EWENEo7o9o4auGpTHVNyvOnipJ9oWDF0Sht%2Ek0x6G2Z1iMY21-sQ2I8cY% 2EVAN7HzGHrabCoBx3oXyRN0sWQkiVDfEg Response Summary: Please fill out the information below: Contact Person: Jeffery Cowlishaw Company Name: Staker Parson Companies Mailing Address: 2350 S 1900 W City: Ogden Zip: 84401 Phone Number: 385-405-4315 Email: jeffery.cowlishaw@stakerparson.com Is the site located within a PM2.5 non-attainment and maintenance plan areas on cleared land grea... No All temporary relocation projects are required to submit a Fugitive Dust Control Plan (FDCP). Lo... 2A51985F96 Briefly give directions to the site and/or physical address: Travel north on hwy 87 from Main Street in Duchesne 1.2 miles. Turn east on 8300S, entrance will be on the left in 350ft. Proposed Relocation Information: Closest City Duchesne County Duchesne UTM X Coordinates 40.18090 UTM Y Coordinates -110.3973 Approximate distance to the nearest house/business 875 feet UTM X Coordinates to nearest house/business 40.18062 UTM Y Coordinates to nearest house/business -110.39993 9/25/24, 9:30 AM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1809831813078883763%7Cmsg-f:1809831813078883763&s…1/3 Does this site currently have a permit with DAQ? No Please provide the permit ID for the equipment? (DAQE-XXXXXXXXX-XX) DAQE-AN132670009-21 Please list all the Equipment on Site:Note: It is important to identify ALL diesel powered engine... 1 Equipment Type Generator Make/Model Kohler Serial or ID# II.A.5 Manufactured Date 2003 Design Capacity 810kw 2 Equipment Type Generator Make/Model Whisperwatt Serial or ID# II.A.5 Manufactured Date Unknown Design Capacity 40kw 3 Equipment Type Hot Plant Make/Model Gencor Serial or ID# II.A.4 Manufactured Date 2020 Design Capacity 400 TPH 4 Equipment Type Generator Make/Model Caterpillar Serial or ID# II.A.5 Design Capacity 3508 kw 5 Equipment Type Jaw Crusher Make/Model Pioneer Serial or ID# II.A.2 Design Capacity 500TPH 6 Equipment Type Cone Crusher Make/Model JCI Serial or ID# II.A.2 Design Capacity 500TPH 7 Equipment Type Cone Crusher Make/Model JCI Serial or ID# II.A.2 Design Capacity 500TPH 8 Equipment Type 3 Screens Make/Model 7x20 Serial or ID# II.A.2 Design Capacity 500TPH Please attach a site diagram showing the equipment layout and general site dimensions for this re... https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_Dw2JWOEdiSivXKp Have any other state or local regulatory agencies issued any other "Conditional Use Permits" for... No Operational Information: (Please note: Operating time over 16 hours in a 24 hour period will re... Total Hours of operation per 24 hr period 16 Starting time of operation (am/pm) 6am Ending time of operation (am/pm) 10pm Maximum hourly production rate for project 500TPH Expected startup date 09/10/2024 Expected completion date 09/09/2025 9/25/24, 9:30 AM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1809831813078883763%7Cmsg-f:1809831813078883763&s…2/3 What type of application is this for? New Application In accordance with the fee schedule approved by the Utah State Legislature, the Division of Air Q... https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_3et2wE7Rp2U1UdN Owner/Operator Representative: https://utahgov.co1.qualtrics.com/WRQualtricsControlPanel/File.php?F=F_1FwBcLwKebKZ1Ip 9/25/24, 9:30 AM State of Utah Mail - Portable/Temporary Relocation Form https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1809831813078883763%7Cmsg-f:1809831813078883763&s…3/3 Susan Weisenberg <sweisenberg@utah.gov> Re: [EXT] Re: Temp Relo Permit Duchesne 1 message Chad Gilgen <cgilgen@utah.gov>Tue, Sep 24, 2024 at 8:26 AM To: Kyle Greenberg <kgreenberg@utah.gov> Cc: Susan Weisenberg <sweisenberg@utah.gov> Thanks, Kyle. I appreciate it. A quick look at the stack test looks like everything is good but I look forward to hearing what you think. Susan - I see you submitted this Temporary Relocation Letter yesterday morning. I am going to cancel it because they have listed their production rate at 500 TPH. This is going to be fine for the aggregate side but they have also noted the design capacity of the hot mix plant at 400 TPH. However, the stack test they submitted indicates the actual production rate at the time of testing was 177 TPH. Per R307-165-4, they are not going to be able to run this hot plant beyond 110% (194 TPH) of this tested production rate for the duration of this project unless they want to do a new stack test. Please let Jeffery know this and update the TRP letter to include this information. Thanks, Chad Chad Gilgen | Manager | Minor Source Compliance 385-306-6500 (cell) Emails to and from this email address may be considered public records and thus subject to Utah GRAMA requirements. On Mon, Sep 23, 2024 at 12:44 PM Kyle Greenberg <kgreenberg@utah.gov> wrote: I'll bump this stack test report to the top of the list and try and get it done by today or tomorrow. On Thu, Sep 19, 2024 at 10:11 AM Chad Gilgen <cgilgen@utah.gov> wrote: Hi Susan, The last thing I see for this one is a pretest was submitted for Site ID 13267 in 2021. Kyle reviewed the pretest and sent them an acceptance letter on April 10, 2021. It looks like they didn't actually stack test until 2023 and this report was never submitted to the DAQ for review. Based on this, we would need Kyle to review this report and let us know if the results are acceptable prior to granting this Temporary Relocation. Thanks, Chad Chad Gilgen | Manager | Minor Source Compliance 385-306-6500 (cell) Emails to and from this email address may be considered public records and thus subject to Utah GRAMA requirements. 9/25/24, 9:43 AM State of Utah Mail - Re: [EXT] Re: Temp Relo Permit Duchesne https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1805012820180874547%7Cmsg-f:1811087935291405660&s…1/6 ---------- Forwarded message --------- From: Susan Weisenberg <sweisenberg@utah.gov> Date: Thu, Sep 19, 2024 at 9:42 AM Subject: Fwd: [EXT] Re: Temp Relo Permit Duchesne To: Chad Gilgen <cgilgen@utah.gov> I submitted a TRP for Staker Parson moving aggregate and asphalt equipment to Duchesne yesterday. I asked Jeffery Cowlishaw to submit the most recent stack test information if he had it. The TRP Letter that I sent in has the standard language regarding stack testing. Let me know if this test that was performed in October of 2023 (see the attached TETCO test) requires deleting the paragraph that references stack testing. Thanks Susan Weisenberg, Environmental Scientist Office: 385-306-6512 ---------- Forwarded message --------- From: Cowlishaw, Jeffery (Staker & Parson Companies) <jeffery.cowlishaw@stakerparson.com> Date: Thu, Sep 19, 2024 at 7:51 AM Subject: RE: [EXT] Re: Temp Relo Permit Duchesne To: Susan Weisenberg <sweisenberg@utah.gov> Susan, Attached is the stack test for the plant in the temp relo. Jeffery (J) Cowlishaw Environmental Specialist North Wasatch C +1(385)405-4315 E Jeffery.cowlishaw@stakerparson.com www.crhamericasmaterials.com From: Susan Weisenberg <sweisenberg@utah.gov> Sent: Monday, September 16, 2024 2:10 PM To: Cowlishaw, Jeffery (Staker & Parson Companies) <jeffery.cowlishaw@stakerparson.com> Subject: Re: [EXT] Re: Temp Relo Permit Duchesne 9/25/24, 9:43 AM State of Utah Mail - Re: [EXT] Re: Temp Relo Permit Duchesne https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1805012820180874547%7Cmsg-f:1811087935291405660&s…2/6 CAUTION: This email originated from outside of the organizaon. Do not click links or open aachments unless you are expecng this email and know the contents are safe. If you believe this email may be phishing or malicious, please use the Report Phish buon. Hello, I've reviewed the September 10th electronic submission for the Main Street in Duchesne asphalt project. Your reported distance to the nearest house or business is 875 feet which is really close for an asphalt project. Can you give me more information about what this referenced house or business is? Also, can you let me know if the asphalt plant has tested in the last 5 years? Thanks Susan Weisenberg, Environmental Scientist Office: 385-306-6512 On Tue, Sep 10, 2024 at 11:48 AM Cowlishaw, Jeffery (Staker & Parson Companies) <jeffery.cowlishaw@ stakerparson.com> wrote: Susan, I have submitted a temporary relocation for our crusher and hot plant at our Kielbasa Pit. This is the site I was figuring out in the messages below. It took a while to get equipment lists but everything should be on the temp relo application. Thanks, Jeffery (J) Cowlishaw Environmental Specialist North Wasatch C +1(385)405-4315 E Jeffery.cowlishaw@stakerparson.com http://secure-web.cisco.com/1c1qlTU0JC-Ibee_HpONsLocrZyOwzYYtwI4aFvDfuf8UOYVr57g_Leat84k- IdG260P4KjOQepdjjlTyfH27luPtuuLeD96nhfTzCXNHi5k5Q2tVvFMxX0pFbtjdzP3hOTYA7fwjhWRr60hZCtvsby mDEZ6hD6uVx7hrcMsvdW5Zky-vAoFHp9WD-pN3C1KA_KlK5vIZPs-G7I9wF- J5PCGqIzsUKkbXserZ4Ra5Xfvw79wakcgFJv9ksvJAGTSorSPcyt6nN2BG-HorSj6eMaakld5wEHq1gAGm0x_ wZW9ScJIpiH569TFt3RcvrQSn36kNDYi4AmeIAuvYyrnTSA/http%3A%2F%2Fwww.crhamericasmaterials.com 9/25/24, 9:43 AM State of Utah Mail - Re: [EXT] Re: Temp Relo Permit Duchesne https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1805012820180874547%7Cmsg-f:1811087935291405660&s…3/6 From: Susan Weisenberg <sweisenberg@utah.gov> Sent: Thursday, August 1, 2024 9:24 AM To: Cowlishaw, Jeffery (Staker & Parson Companies) <jeffery.cowlishaw@stakerparson.com> Subject: Re: [EXT] Re: Temp Relo Permit Duchesne CAUTION: This email originated from outside of the organizaon. Do not click links or open aachments unless you are expecng this email and know the contents are safe. If you believe this email may be phishing or malicious, please use the Report Phish buon. I can't find any relocations using that Approval Order. The most recent document issued for this permit was a stack test review of a test performed on March 9, 2022. If the relocation project is still active you can submit it now and I'll let Chad know that you have had a change in personnel. Susan Weisenberg, Environmental Scientist Office: 385-306-6512 On Wed, Jul 31, 2024 at 11:47 AM Cowlishaw, Jeffery (Staker & Parson Companies) <jeffery.cowlishaw@ stakerparson.com> wrote: Susan, The AO should be DAQE-AN132670009-21. I’m not sure when it would have been submitted because it wouldn’t have been me. Jeffery (J) Cowlishaw Environmental Specialist North Wasatch C +1(385)405-4315 E Jeffery.cowlishaw@stakerparson.com http://secure-web.cisco.com/1Vuz3qysp1C70fA7KcY80fJIv-D_7NgbsYI0xmh7dprfZfRu1exL9EQ4_ 7xZmvrZmkjnIuqUIN0Q0szxpjjwnLJjRcYdZ_jlLqu-QBfXHCYheU5sZctrgp8RNkyjPxUw1w xqTJwQPoduoLf4yq8RLPWSAhsOelLSSOZzriLrBbnQQ04imTkYMsIWDcrBdz9G5Lv6koF4IbpheUn8zs- hPTAdyx0aA4UKou_AOCx8GzkHWM2wKyPJvOiCTsBON3Th8M9mSWvNuH97fPy01bSxNhIiAMouG- 9/25/24, 9:43 AM State of Utah Mail - Re: [EXT] Re: Temp Relo Permit Duchesne https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1805012820180874547%7Cmsg-f:1811087935291405660&s…4/6 4cDFT5DdmLQrCaYDaNrzsxgLOTJmH3lhLtOVU4uYVXRkZVp4XuVFyCIGg/http%3A%2F%2Fwww. crhamericasmaterials.com From: Susan Weisenberg <sweisenberg@utah.gov> Sent: Friday, July 19, 2024 12:35 PM To: Cowlishaw, Jeffery (Staker & Parson Companies) <jeffery.cowlishaw@stakerparson.com> Subject: [EXT] Re: Temp Relo Permit Duchesne CAUTION: This email originated from outside of the organizaon. Do not click links or open aachments unless you are expecng this email and know the contents are safe. If you believe this email may be phishing or malicious, please use the Report Phish buon. Hello, I'm not seeing this asphalt plant relocation. Can you give me an approximate submittal date? The referenced AOs will also be helpful. Thanks Susan Weisenberg, Environmental Scientist Office: 385-306-6512 On Fri, Jul 19, 2024 at 7:06 AM Cowlishaw, Jeffery (Staker & Parson Companies) <jeffery.cowlishaw@ stakerparson.com> wrote: Susan, Will you please see if there is a temporary relocation approval for a hot plant at our Kielbasa site which is just north of Duchesne city. I think it may have been submitted right around the time that a couple of our employees left and we don’t have record of it. The application may have been submitted and the approval never received by the person. Thanks, Jeffery (J) Cowlishaw Environmental Specialist North Wasatch 9/25/24, 9:43 AM State of Utah Mail - Re: [EXT] Re: Temp Relo Permit Duchesne https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1805012820180874547%7Cmsg-f:1811087935291405660&s…5/6 C +1(385)405-4315 E Jeffery.cowlishaw@stakerparson.com http://secure-web.cisco.com/1wUZqbTSWxpFDuAwkjKCrTN1DCkP0y OPjjHvV9OAgFUOE3rbk8ua2Oeckfvx1Nv9a5JBKkxcCQwQmxlf8ouH_cpjAvtr4c-RRFgaxqfBSW_ ixRPrjZDw2V2fESBo_o6RaFK5g4sN7qI3M4jJwg0zQO8Sm1XAdbut49RifDMFYEpjjNNayCKMp3SLC 08SE7iQJeE_wjKbbnVynHfb4_5ODgQBfVgHHTKpnLBXQjMLsDTGGXeX RHy_V18KaJhdBsP3rZsCI1JDPLCji_ji1E28SZbwN0UAfVKmGuO1VrviuEz6 PLRG1lta9IS8q2sAdkf9tOjDUbcgJqhLq90Oxq6j0jg/http%3A%2F%2Fwww.crhamericasmaterials.com ATTENTION: Ce courriel vient de l'exterieur de l'entreprise. Ne cliquez pas sur les liens, et n'ouvrez pas les pièces jointes, à moins que vous ne connaissiez l'expéditeur du courriel et savez que le contenu est sécuritaire. Si vous pensez qu’il s’agit d’un courriel d’hameçonnage ou malveillant, veuillez cliquer sur le bouton Signaler une tentave d’hameçonnage. ATTENTION: Ce courriel vient de l'exterieur de l'entreprise. Ne cliquez pas sur les liens, et n'ouvrez pas les pièces jointes, à moins que vous ne connaissiez l'expéditeur du courriel et savez que le contenu est sécuritaire. Si vous pensez qu’il s’agit d’un courriel d’hameçonnage ou malveillant, veuillez cliquer sur le bouton Signaler une tentave d’hameçonnage. ATTENTION: Ce courriel vient de l'exterieur de l'entreprise. Ne cliquez pas sur les liens, et n'ouvrez pas les pièces jointes, à moins que vous ne connaissiez l'expéditeur du courriel et savez que le contenu est sécuritaire. Si vous pensez qu’il s’agit d’un courriel d’hameçonnage ou malveillant, veuillez cliquer sur le bouton Signaler une tentave d’hameçonnage. -- Kyle Greenberg Environmental Scientist | Minor Source Compliance P: (385) 306-6533 airquality.utah.gov Emails to and from this email address may be considered public records and thus subject to Utah GRAMA requirements. 9/25/24, 9:43 AM State of Utah Mail - Re: [EXT] Re: Temp Relo Permit Duchesne https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-f:1805012820180874547%7Cmsg-f:1811087935291405660&s…6/6 Susan Weisenberg <sweisenberg@utah.gov> Temporary Relocation to Duchesne 1 message Susan Weisenberg <sweisenberg@utah.gov>Wed, Sep 25, 2024 at 8:55 AM To: "Cowlishaw, Jeffery (Staker & Parson Companies)" <jeffery.cowlishaw@stakerparson.com> Hello, the relocation for the aggregate and asphalt equipment was submitted for Chad's signature last Monday. It looks like the asphalt stack test has been reviewed and will be approved. However, the asphalt plant was running at 177 TPH during the test. The language of R307-165-4 allows asphalt plants to operate at 110% of the most recent test. Because of this, I've been asked to modify the authorized production rate for the asphalt plant to be 194. Let me know if you have any questions, or you can contact Chad at 385-306-6500. Thanks Susan Weisenberg, Environmental Scientist Office: 385-306-6512 R307-165.pdf 68K 9/25/24, 8:58 AM State of Utah Mail - Temporary Relocation to Duchesne https://mail.google.com/mail/u/0/?ik=bffac613d3&view=pt&search=all&permthid=thread-a:r-8494468839556936376%7Cmsg-a:r-55175403933499206…1/1