Loading...
HomeMy WebLinkAboutDDW-2024-011481DESIGNED BY PROJECT NUMBER FOR: PROJECT MANAGER PRINT DATE PHONE: CONTACT: WWW.ENSIGNENG.COM SANDY 45 W. 10000 S., Suite 500 Sandy, UT 84070 Phone: 801.255.0529 LAYTON Phone: 801.547.1100 TOOELE Phone: 435.843.3590 CEDAR CITY Phone: 435.865.1453 RICHFIELD Phone: 435.896.2983 MECHANICAL PLAN 126567 M-100 PE N N Y ' S C A F E D I S I N F E C T I O N 29 N M A I N S T R E E T TO O E L E , U T A H 8 4 0 7 4 PENNY'S GRILL LLC 29 N MAIN STREET TOOELE, UT 84074 DAVE LAW (801) 450-0779 R. ROUSELLE G. OFFERMANN 2024-09-26 RECORD DRAWINGS SCALE:1 1" = 1'-0" PLAN VIEW EXISTING 1" GALV WATER LINE FROM EXISTING WELL A M-101 B M-101 C M- 1 0 1 C M- 1 0 1 B M-101 NOTES: 1.REFER TO SHEET M-300 FOR VALVE, MECHANICAL, PUMP, AND HVAC SCHEDULES. 2.ALL BOLTS SHALL BE STAINLESS STEEL. 3.ALL PIPE, VALVES, FITTINGS, AND APPURTENANCES SHALL BE RATED FOR A MINIMUM PRESSURE OF 150 PSI. 4.PAINT PIPES, FITTINGS, PIPE STANDS, AND APPURTENANCES BLUE. 5.PAINT VALVES BLUE. 6.PAINT SHALL BE WELL VENTILATED PER PAINT MANUFACTURER'S RECOMMENDATIONS DURING OFF GASSING PERIOD. 7.PROVIDE PIPE SUPPORTS AS SHOWN IN MECHANICAL DETAILS. 8.GALVANIZED, PVC, SS, AND DIP PIPE AND FITTINGS ARE SHOWN. 9.CONTRACTOR SHALL DETERMINE FITTINGS WHEN CONNECTING TO INSTRUMENTS AND CHEMICAL TUBING. NOT ALL FITTINGS TO INSTRUMENTS AND CHEMICAL TUBING ARE SHOWN. 10.WHERE DISSIMILAR METALS CONNECT (EXAMPLE: BRASS OR COPPER AND GALVANIZED IRON), REFER TO GALVANIC CORROSION TABLE SHOWN ON THIS SHEET. PROVIDE A DIELECTRIC COUPLER, DIELECTRIC FLANGE KIT, OR OTHER METHOD TO KEEP DISSIMILAR METALS FROM CONTACTING. 11.ELECTRICAL AND OPERATIONAL REQUIREMENTS ARE SHOWN ON THIS DRAWING. CONTRACTOR TO HIRE ELECTRICIAN TO INSTALL AND COMPLY WITH OPERATIONAL REQUIREMENTS PER APPLICABLE BUILDING AND ELECTRICAL CODES. 12.COORDINATE WITH OWNER TO RELOCATE EXISTING IMPROVEMENTS AND ITEMS IN BASEMENT. 13.INSTALL 6-INCH ROUND DUCT (EXHAUST) TO WITHIN 6-INCHES OF FLOOR, TO TOP OF SEALING PENETRATING EXTERIOR WALL BETWEEN THE EXISTING FLOOR JOISTS, AND CONNECT TO EXTERIOR MOUNTED EXHAUST FAN. MAINTAIN CLEARANCES AS REQUIRED BY INTERNATIONAL BUILDING CODE. 14.CONNECT TO EXISTING COLD WATER CONNECTIONS BY TRANSITIONING TO PEX PIPE (PROVIDE ADEQUATE PIPING, FITTINGS, AND APPURTENANCES TO MAKE CONNECTIONS) ZINC GALVANISED STEEL ALUMINUM CADMIUM CAST IRON LEAD MILD STEEL TIN LEAD-TIN SOLDER CHROMIUM PLATE BRASS COPPER NICKEL STAINLESS STEEL ZI N C GA L V A N I S E D S T E E L AL U M I N U M CA D M I U M CA S T I R O N LE A D MI L D S T E E L TI N LE A D - T I N S O L D E R CH R O M I U M P L A T E BR A S S CO P P E R NI C K E L ST A I N L E S S S T E E L MO R E N O B L E LE S S N O B L E ANODIC CATHODIC MORE NOBLELESS NOBLE CATHODIC = GALVANIC ACTION INSIGNIFICANT = GALVANIC ACTION MIGHT OCCUR = GALVANIC ACTION WILL OCCUR KEY GALVANIC CORROSION TABLE P-101 EXISTING WELL CONTROL PANEL MOUNTED ON FLOOR JOISTS. PROTECT THROUGHOUT CONSTRUCTION AND ADJUST PRESSURE SWITCH CONNECTION AS REQUIRED. A M-101 BASEMENT/MECHANICAL ROOM EXISTING STAIRS UP TO FIRST FLOOR EXIST PRESSURE TANK EXIST HOT WATER HEATER TREATED WATER TO RESIDENCE TREATED WATER TO PENNY'S CAFE V-002 V-003 V-004 V-001 EMERGENCY EYEWASH STATION V-005 V-009 V-007 5 1 14 1 1 14 1 1 8 1 8 1 8 1 1 8 1 6 7 8 3 939 3 9 10 V-008 T-002 T-001 V-006 CONNECT TO EXIST WATER LINECONNECT TO EXIST GALV PIPING SYSTEM P-002 16 11 1 8 1 1 9 10 13 9 9 3 EXHAUST FAN ROUTED TO EXTERIOR M-004 M-003 PS-001 M-001 M-002 PIPE AND FITTING SCHEDULE ID SIZE SHORT DESCRIPTION MATERIAL FITTING REMARKS 1 1"PIPE PEX PEX BARB 2 1 1/4"PIPE SCH80 PVC SLIP X THDM 3 1 1/4"PIPE SCH80 PVC SLIP 4 4"AIR DUCT AIR DUCT SS CLAMP 5 1" X 3/4"REDUCING COUPLER BRASS SLIP X PEX BARB 6 1 1/4"TRUE UNION SCH80 PVC SLIP 7 1 1/4" X 1"REDUCING COUPLER SCH80 PVC SLIP 8 1"ELBOW 90 BRASS PEX BARB 9 1 1/4"ELBOW 90 SCH80 PVC SLIP 10 1 1/4"NIPPLE, CLOSE TYPE SCH80 PVC SLIP 11 1 1/4"NIPPLE, CLOSE TYPE SCH80 PVC THDM 12 1 1/4"PLUG SCH80 PVC THDM 13 3/4"x1/2"ADAPTER BRASS THDM 14 1"TEE BRASS PEX BARB 15 1 1/4"TEE SCH80 PVC SLIP X THDF 16 1 1/4"TEE SCH80 PVC SLIP 12 15 12 3 RECORD DRAWING NOTE: THESE RECORD DRAWINGS ARE BASED ON CONTRACTOR FURNISHED INFORMATION. WHILE THE INFORMATION SUBMITTED BY THE CONTRACTOR AND INCORPORATED BY THE ENGINEER INTO THE RECORD DOCUMENTS IS ASSUMED TO BE RELIABLE, THE ENGINEER WILL NOT BE RESPONSIBLE FOR THE ACCURACY OF THE INFORMATION NOR FOR ERRORS OR OMISSIONS WHICH MAY APPEAR IN THE RECORD DOCUMENTS AS A RESULT. DESIGNED BY PROJECT NUMBER FOR: PROJECT MANAGER PRINT DATE PHONE: CONTACT: WWW.ENSIGNENG.COM SANDY 45 W. 10000 S., Suite 500 Sandy, UT 84070 Phone: 801.255.0529 LAYTON Phone: 801.547.1100 TOOELE Phone: 435.843.3590 CEDAR CITY Phone: 435.865.1453 RICHFIELD Phone: 435.896.2983 MECHANICAL SECTIONS 126567 M-101 PE N N Y ' S C A F E D I S I N F E C T I O N 29 N M A I N S T R E E T TO O E L E , U T A H 8 4 0 7 4 PENNY'S GRILL LLC 29 N MAIN STREET TOOELE, UT 84074 DAVE LAW (801) 450-0779 R. ROUSELLE G. OFFERMANN 2024-09-26 RECORD DRAWINGS NOTES: 1.SEE SHEET M-100 FOR NOTES, AND PIPE AND FITTING SCHEDULE. 2.SEE SHEET M-300 FOR PUMP, VALVE AND MECHANICAL SCHEDULES. SCALE: 1 M-100 SECTION A-A 1" = 1'-0"SCALE: 2 M-100 SECTION B-B 1" = 1'-0" SCALE: 1 M-100 SECTION C-C 1" = 1'-0" P-002 V-007 V-009 1 8 1818 1 V-002 V-001 V-003 5 1 14 3 9 316 3 6 T-001 T-002 9 13 16 9 36 3 91818 16 188 1114 11 8 1 8 1 7 6 3 6 3 16 3 9 6 3 16 V-006 V-008 T-002 T-001 P-002 V-005 V-007 V-009 V-001 V-003 V-002 SPILL CONTAINMENT TRAY W/ (2) 5 GALLON CONTAINERS SPILL CONTAINMENT TRAY W/ (2) 5 GALLON CONTAINERS V-006 V-008 CHLORINE INJECTION PORT EXISTING PRESSURE TANK AND PIPING TREATED WATER TO RESIDENCE EXISTING WELL CONTROL PANEL MOUNTED ON FLOOR JOISTS. PROTECT THROUGHOUT CONSTRUCTION AND ADJUST PRESSURE SWITCH CONNECTION AS REQUIRED. CONNECT TO EXIST PIPING TO PRESSURE TANK 8TREATED WATER TO PENNY'S CAFE EMERGENCY EYEWASH STATION 3' - 4 " EXHAUST FAN ROUTED TO EXTERIOR W/ 4-INCH DIA DUCT CHLORINE INJECTION LINES 10 9 9 EXISTING 1" GALV WATER LINE FROM EXISTING WELL P-101 NOTE: EXISTING HOT WATER HEATER AND SOME EXISTING PIPING NOT SHOWN FOR CLARITY M-003 2 M-200 CONDUIT SUPPORT (TYP) 2 M-200 CONDUIT SUPPORT (TYP) PS-001 1 1 8 2 2 22 12 4 4 EXISTING WELL CONTROL PANEL MOUNTED ON FLOOR JOISTS. PROTECT THROUGHOUT CONSTRUCTION AND ADJUST PRESSURE SWITCH CONNECTION AS REQUIRED. NOTE: EXISTING HOT WATER HEATER AND SOME EXISTING PIPING NOT SHOWN FOR CLARITY NOTE: EXISTING HOT WATER HEATER AND SOME EXISTING PIPING NOT SHOWN FOR CLARITY 12 12 M-001 RECORD DRAWING NOTE: THESE RECORD DRAWINGS ARE BASED ON CONTRACTOR FURNISHED INFORMATION. WHILE THE INFORMATION SUBMITTED BY THE CONTRACTOR AND INCORPORATED BY THE ENGINEER INTO THE RECORD DOCUMENTS IS ASSUMED TO BE RELIABLE, THE ENGINEER WILL NOT BE RESPONSIBLE FOR THE ACCURACY OF THE INFORMATION NOR FOR ERRORS OR OMISSIONS WHICH MAY APPEAR IN THE RECORD DOCUMENTS AS A RESULT. SCALE:2 NONE TYPICAL CONDUIT SUPPORT DETAIL 6" M I N AS R E Q ' D ( 5 ' - 0 " M A X ) CONCRETE WALL OR SLAB SS CA, NUTS AND 1 5/8" SQ WASHERS AS REQ'D (TYP) CONDUIT CLAMPS W/ SS BOLTS, NUTS AND WASHERS NOTES: 1.THIS DETAIL TYPICAL FOR BOTH VERTICAL AND HORIZONTAL MOUNTING. 2.PREFORMED CHANNEL, FITTINGS AND CLAMPS SHALL BE HOT-DIP GALVANIZED STEEL. FIELD COAT ALL CUTS PER SPECIFICATIONS. 3.CHANNELS TO BE SPACED AT 5'-0" MAXIMUM. 3" M I N 'D ' 'C' 'B''D ' 13 1/2 11 11 *SEE MFR. 18 36 32 30 24 20 16 14 12 8 10 6 6 3 1/2 6 6 6 6 6 4 4 4 4 3 1/2 3 4 4 3 3 3 3 3 *2 1/2 9 *2 1/2 *2 1/2 *2 1/2 9 9 9 2421 1/4 32 5/8 30 5/8 29 5/8 26 1/2 23 1/4 34 3/4 32 3/4 25 1/2 28 1/1 31 1/2 19 7/8 18 7/8 15 5/8 13 5/8 14 5/8 11 5/8 20 3/4 19 3/4 22 1/4 15 1/4 18 1/4 16 1/2 ADJUSTABLE PIPE SUPPORT APPROXIMATE DIMENSIONS IN INCHES PIPE DIA 2 1/2 4 3 1/2 3 2 1/2 3 2 1/2 2 1/2 'A' 91 1/2 *2 1/2 1 1/2 1 1/2 9 9 9 'B''C' 8 10 1/4 8 1/2 8 1/4 MINIMUM 'D' 11 1/2 11 3/4 14 12 MAXIMUM 'D' 13 1/2 13 1/2 13 1/2 13 1/2 13 1/2 'A' SS ANCHOR BOLT OR SELF-DRILLING CONCRETE SS ANCHOR W/ STUD AND (2) NUTS EA, SIZE TO SUIT FLANGE (TYP OF 4 @ 90°) 1"MI N 'U' BOLT PIPE SUPPORT GRINNELL FIG. 259, ELCEN FIG. 49, OR EQ ADJUSTABLE PIPE SUPPORT GRINNELL FIG. 264, ELCEN FIG. 50, OR EQ DRY PACK 150 LB THREADED REDUCING FLANGE GALVANIZED 'C' 'B' 'A' SCALE:1 NONE TYPICAL PIPE SUPPORT DETAIL DESIGNED BY PROJECT NUMBER FOR: PROJECT MANAGER PRINT DATE PHONE: CONTACT: WWW.ENSIGNENG.COM SANDY 45 W. 10000 S., Suite 500 Sandy, UT 84070 Phone: 801.255.0529 LAYTON Phone: 801.547.1100 TOOELE Phone: 435.843.3590 CEDAR CITY Phone: 435.865.1453 RICHFIELD Phone: 435.896.2983 MECHANICAL DETAILS NO.DATE REVISION 126567 M-200 PE N N Y ' S C A F E D I S I N F E C T I O N 29 N M A I N S T R E E T TO O E L E , U T A H 8 4 0 7 4 PENNY'S GRILL LLC 29 N MAIN STREET TOOELE, UT 84074 DAVE LAW (801) 450-0779 R. ROUSELLE G. OFFERMANN 2024-09-26 RECORD DRAWINGS RECORD DRAWING NOTE: THESE RECORD DRAWINGS ARE BASED ON CONTRACTOR FURNISHED INFORMATION. WHILE THE INFORMATION SUBMITTED BY THE CONTRACTOR AND INCORPORATED BY THE ENGINEER INTO THE RECORD DOCUMENTS IS ASSUMED TO BE RELIABLE, THE ENGINEER WILL NOT BE RESPONSIBLE FOR THE ACCURACY OF THE INFORMATION NOR FOR ERRORS OR OMISSIONS WHICH MAY APPEAR IN THE RECORD DOCUMENTS AS A RESULT. DESIGNED BY PROJECT NUMBER FOR: PROJECT MANAGER PRINT DATE PHONE: CONTACT: WWW.ENSIGNENG.COM SANDY 45 W. 10000 S., Suite 500 Sandy, UT 84070 Phone: 801.255.0529 LAYTON Phone: 801.547.1100 TOOELE Phone: 435.843.3590 CEDAR CITY Phone: 435.865.1453 RICHFIELD Phone: 435.896.2983 MECHANICAL SCHEDULES 126567 M-300 PE N N Y ' S C A F E D I S I N F E C T I O N 29 N M A I N S T R E E T TO O E L E , U T A H 8 4 0 7 4 PENNY'S GRILL LLC 29 N MAIN STREET TOOELE, UT 84074 DAVE LAW (801) 450-0779 R. ROUSELLE G. OFFERMANN 2024-09-26 RECORD DRAWINGS Valve Schedule Tag #Description/Type Size Material Operation Connection Remarks V-001 Ball Valve 1-inch Brass Lever Barb Apollo, Brass Pex-B Barb Ball Valve, or Equal V-002 Ball Valve 1-inch Brass Lever Barb Apollo, Brass Pex-B Barb Ball Valve, or Equal V-003 Ball Valve 1-inch Brass Lever Barb Apollo, Brass Pex-B Barb Ball Valve, or Equal V-004 Check Valve 1 1/4-inch Sch 80 PVC N/A Slip x THDF PVC True Union Ball Check Valve V-005 Ball Valve 1 1/4-inch Sch 80 PVC Lever Slip x THDF Threaded/Slip PVC Ball Valve V-006 Combination Air/Vac Valve 1/2-inch PVC N/A Threaded A.R.I. Model No. D-040 or Equal V-007 Ball Valve 1 1/4-inch Sch 80 PVC Lever Slip x THDF Threaded/Slip PVC Ball Valve V-008 Combination Air/Vac Valve 1/2-inch PVC N/A Threaded A.R.I. Model No. D-040 or Equal V-009 Smooth Nosed Sampling Tap 1/2-inch Chrome Plated Brass Wheel Threaded Matco-Norca Model No. FY-691LF, or Equal Mechanical Equipment Schedule Tag #Description/Type kW/Size Remarks PS-001 Pressure Switch -Existing Pressure Switch M-001 Pressure Tank 85.0 Gallons, 1 1/4-inch Existing Flexcon Industries Model H2P 85 T-001 Disinfection Tank 80.0 Gallons MixMaster Model BAF 80 T-002 Disinfection Tank 80.0 Gallons MixMaster Model BAF 80 M-002 Spill Containment Tray 15 Gallons/27-inch (L) x 27-inch (W) x 6 3/4-inch (H)Uline Model H-2762 or Equal M-003 Liquid Chlorine Storage Tank 5 gallons / rectangular Two (2) 5 Gallon Containers or Equal M-004 Exhaust Fan 120V "Soler & Palau External Mounted Exhaust Fan, Model No. SWF-150X (332 cfm @ 0.100 in SP) or equal Fan to be operated by switch at the top of stairs which should also operate the overhead light for the basement area where mechancial equipment shown on this plan is housed." Pump Schedule Tag #Description/Type HP/Size Remarks P-001 Existing Submersible Well Pump Existing Existing (Not Part of Project) P-002 Chemical Metering Pump 115V "Stenner Pump Company Model S3001 Peristaltic Metering Pump Chemical Metering Pump to be wired to switch so it will turn on and only operate when the well pump is operating." Note: All valves, fittings, pumps, and mechanical equipment within the basement shall be rated for a minimum pressure rating of 150 psi. RECORD DRAWING NOTE: THESE RECORD DRAWINGS ARE BASED ON CONTRACTOR FURNISHED INFORMATION. WHILE THE INFORMATION SUBMITTED BY THE CONTRACTOR AND INCORPORATED BY THE ENGINEER INTO THE RECORD DOCUMENTS IS ASSUMED TO BE RELIABLE, THE ENGINEER WILL NOT BE RESPONSIBLE FOR THE ACCURACY OF THE INFORMATION NOR FOR ERRORS OR OMISSIONS WHICH MAY APPEAR IN THE RECORD DOCUMENTS AS A RESULT.