Loading...
HomeMy WebLinkAboutDAQ-2024-010442 195 North 1950 West • Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820 Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 903-3978 www.deq.utah.gov Printed on 100% recycled paper State of Utah Department of Environmental Quality Kimberly D. Shelley Executive Director DIVISION OF AIR QUALITY Bryce C. Bird Director SPENCER J. COX Governor DEIDRE HENDERSON Lieutenant Governor DAQC-910-24 Site ID 10122 (B5) Brady Miller, Environmental Engineer Big West Oil 333 West Center Street North Salt Lake, UT 84054 Dear Mr. Miller: Re: Big West Oil – Pretest Protocol for Flow, Oxygen (O2), Sulfur Dioxide (SO2), and Hydrogen Sulfide (H2S) Relative Accuracy Test – Davis County The Utah Division of Air Quality (DAQ) reviewed Big West Oil’s pretest protocol dated September 3, 2024. The proposed test shall be performed under the following conditions: Big West Oil’s monitoring system to be certified: Point Source Channel Manufacturer Model # Monitor SN Sulfur Recovery Unit SRU O2 Emerson / Rosemount X-Stream X2 XMF08002693435 SO2 Emerson / Rosemount X-Stream X2 XMF08002693435 Amine Unit H2S Ametek 5100 HD 1021950 South Flare H2S Extrel Core Mass MAX 300-IG 61728 West Flare H2S Extrel Core Mass MAX 300-IG 61727 Erthwrks, Inc. will conduct a relative accuracy/performance specification test on Big West Oil’s continuous monitoring system. Relative accuracy must be determined in the units of the emission standard or equivalent units of the emission standard, i.e., tons/year shall be tested in pounds/hour or lb Hg/MM ton clinker 30-DRA shall be tested as lb Hg/MM ton clinker. " - 1 " * " / Ú á Û Ù Û Ý DAQC-910-24 Page 2 The DAQ understands that Erthwrks, Inc. will conduct testing as follows: Test Date Point Source Parameter EPA Reference Method October 22, 2024 SRU Flow Method 1, 2, 3A, and 4 O2 Method 3A SO2 Method 6C October 23, 2024 West Flare H2S 15 October 23, 2024 South Flare H2S 15 October 24, 2024 Amine Unit H2S 11 • Reference Method 1 - Sample and Velocity Traverses for Stationary Point Sources as outlined in 40 CFR 60 Appendix A shall be used to determine the location and number of sampling points as applicable. • Reference Method 2 - Determination of Stack Gas Velocity and Volumetric Flow Rate – (Type S Pitot Tube) as outlined in 40 CFR 60 Appendix A. • Reference Method 3A - Determination of Oxygen and Carbon Dioxide Concentrations in Emissions from Stationary Point Sources – (Instrumental Analyzer Procedure) as outlined in 40 CFR 60 Appendix A. • Reference Method 4 - Determination of Moisture Content in Stack Gases as outlined in 40 CFR 60 Appendix A shall be used to determine the stack gas moisture content. • Reference Method 6C - Determination of Sulfur Dioxide Emissions from Stationary Point Sources - (Instrumental Analyzer Procedure) as outlined in 40 CFR 60 Appendix A. • Reference Method 11 - Determination of Hydrogen Sulfide Content of Fuel Gas Streams in Petroleum Refineries as outlined in 40 CFR 60 Appendix A. • Reference Method 15 - Determination of H2S Concentrations Using a Gas Chromatograph with Flame Photometric Detector as outlined in 40 CFR 60 Appendix A. Zero drift and calibration drift checks are required in accordance with Performance Specification 7. • Deviations - The Director or the representative of the Director must be notified of and approve deviations of the Reference Method test. Any deviation from these conditions without approval from the DAQ may constitute rejection of these tests. Acceptance of a protocol does not relieve the owner/operator and the testing contractor from strict adherence to all applicable EPA methods, DAQ policies, Utah Air Quality Rules (UAQR), and methods approved by the Director. Any deviation from EPA methods, DAQ policies, UAQR, and methods approved by the Director must be addressed separately and express written consent given prior to commencement of testing. • Field data shall be provided to the DAQ in a timely manner for review. DAQC-910-24 Page 3 • The Director will determine the relative accuracy of each monitoring system based on Point Source continuous emission monitoring data and test data acquired by the staff member of the DAQ during the test. • All test reports must be submitted to the Director not later than 60 days after completion of the test. • The test report shall include all raw calibration data and raw emission data with date and time stamps. Relative accuracy test reports must contain: 1. Point source continuous monitor, channel, manufacturer, and serial number, 2. Raw stack test data and continuous monitor data with date and time stamps. 3. Emission data reported in concentration (ppm or %) and units in the applicable emission limit. The DAQ requires that all test reports include a statement signed by a responsible official certifying that: 1. Testing was conducted while the Point Source was operating at the rate and/or conditions specified in the applicable approval order, operating permit, or federal regulation. 2. During testing, the Point Source combusted fuels, used raw materials, and maintained process conditions representative of normal operations, and operated under such other relevant conditions specified by the Director. 3. Based on information and belief formed after reasonable inquiry, the statements and information contained in the report are true, accurate, and complete. Should you have any questions concerning this matter, contact me at (801) 536-4438 or by email at rleishman@utah.gov. Sincerely, Rob Leishman, Environmental Scientist Major Source Compliance Section RL:jl CC: Davis County Health Department Erthwrks, Inc. * $ . # ( ) - — + @ E v A ? A C @ ? w A H ˜ Rob Leishman Jr