Loading...
HomeMy WebLinkAboutDDW-2024-011427Sanitary Survey - Deficiency Report PWS Number:UTAH19018 Deficiency Points:180 Survey Date:09/13/2024 Survey Name:DEVILS CANYON CAMPGROUND Surveyor:David Kruse Sanitary Survey Category: SM SDWIS Severity Code: Significant Deficiency General Maintenance and Environment | DS001 | UTAH19018 DISTRIBUTION SYSTEM 39. Are there any visual indications of unsanitary conditions? Rule: R309-200-6, R309-105-18, R309-215-4(3)R309-200-6 The Secondary Maximum Contaminant Levels for public water systems deals with substances which affect the aesthetic quality of drinking water. They are presented here as recommended limits or ranges and are not grounds for rejection. The taste of water may be unpleasant and the usefulness of the water may be impaired if these standards are significantly exceeded. R309-105-18 The Director or the local health department shall be informed by telephone by a water supplier of any "emergency situation". The term "emergency situation... R309-215-4(3) If the water fails to meet minimum standards, then certain public notification procedures shall be carried out, as outlined in R309-220. Water suppliers shall also keep analytical records in their possession, for a required length of time, as outlined in R309-105-17. Notes:A dead mouse was observed floating in what is considered the spring collection box. At that point in time, the system was already drained of all water due to a pump failure. System was directed to remove the mouse and drain the spring. Complete disinfection will be required prior to placing the system back online. Deficiency Points: 50 Days until points become effective on IPS: 120 SDWIS Deficiency Description: M017 WATER STAGNATION, BIOFILM OR SEDIMENTS CONTRIBUTES TO DRINKING WATER CONTAMINATION Sanitary Survey Category: SO SDWIS Severity Code: Significant Deficiency Springs | WS001 | SPRING 62B. Spring box lid is gasketed Rule: R309-515-7(7)(d), R309-545-14 (2)Access openings shall comply with R309-545 and be provided with a cover furnished with a gasket between the lid and frame. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:A gasket was not observed during the inspection. Please ensure that the second door containing the spring collection basin is adequately sealed. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: SS10 SPRING BOX LID LACKS A GASKET Sanitary Survey Category: SO SDWIS Severity Code: Significant Deficiency Springs | WS001 | SPRING 62F. All openings/penetrations in the spring collection box are sealed. Rule: R309-515-7(7)(d), R309-545-9(1) and (2)All junction and collection boxes shall comply with R309-545 and shall have suitable watertight roofs and sidewalls that exclude birds, animals, insects, and excessive dust. All openings shall be kept to a minimum and be watertight. Pipes that may contain water of lesser quality than drinking water shall not penetrate the spring box. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:The two doors which contain the spring are not sealed. Please work to completely seal the openings around both doors to ensure that critters cannot access the spring collection basin. Deficiency Points: 50 Days until points become effective on IPS: 120 SDWIS Deficiency Description: SS20 UNSEALED OPENINGS IN SPRING COLLECTION BOX Sanitary Survey Category: SO SDWIS Severity Code: Minor Deficiency Springs | WS001 | SPRING 64. Spring has a permanent flow-measuring device. Rule: R309-515-7(7)(h)Rule requires a spring to have a permanent flow measuring device. Notes:No permanent flow measuring device. Deficiency Points: 5 Days until points become effective on IPS: 0 SDWIS Deficiency Description: SS01 LACKS A PERMANENT DEVICE FOR MEASURING SPRING FLOW Sanitary Survey Category: FW SDWIS Severity Code: Significant Deficiency Storage Tanks | ST001 | LOWER TANK 77B. Overflow line covered with #4 mesh non-corrodible screen Rule: R309-545-13(3)Rule requires overflow pipes to be screened with #4 mesh non-corrodible screens installed at a location least susceptible to damage by vandalism. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Overflow line screen has degraded and is no longer sealed. Please replace overflow line screen. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: V012 END OF STORAGE TANK OVERFLOW PIPE LACKS NO. 4 SCREEN Sanitary Survey Category: FW SDWIS Severity Code: Significant Deficiency Storage Tanks | ST002 | UPPER TANK 85C. Access opening lid properly gasketed Rule: R309-545-14(2)Rule requires the access opening to a tank to be furnished with a gasket between the lid and frame. This significant deficiency must be corrected within 120 days of notification or have a corrective action plan approved by DDW. Notes:Gasket has degraded and is no longer in place. Please replace gasket. Deficiency Points: 25 Days until points become effective on IPS: 120 SDWIS Deficiency Description: V009 STORAGE TANK LID LACKS A FUNCTIONING GASKET BETWEEN THE LID AND FRAME