Loading...
HomeMy WebLinkAboutDERR-2024-011040Annual Sump Inspection IMPACT VALVE LEAK DETECTOR Line Tightness Test MONITOR CERTIFICATION SPILL BUCKET TEST STAGE I SURVEY 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 9/24/2024 UTAH DEPARTMENT OF ENV. QUALITY UST PO Box 144840 SALT LAKE CITY, UT 84114 Test Date: 9/17/2024 Order Number: 2371456 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: WALMART #3454 (WM3454) 1200 S COMMERCE WAY BRIGHAM CITY, UT 84302 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting Product Line Tightness Test Page 1 of 1 Work Order: 2371456 Date: 9/17/2024 Site Name/ID: WALMART #3454 / WM3454 Address: 1200 S COMMERCE WAY City: BRIGHAM CITY State: UT Zip: 84302 Tank Information Test Method Customer Tank ID Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Tank # 1 Line # 1 TLD-1 1 RUL Pressure 60 07:57 08:57 0.00 Pass Yes Tank # 2 Line # 1 TLD-1 2 RUL 2 Pressure 60 07:59 08:59 0.00 Pass Yes Tank # 3 Line # 1 TLD-1 3 PREMIUM Pressure 60 07:57 08:57 0.00 Pass Yes Tank # 3 Line # 2 TLD-1 3 PREMIUM Pressure 60 07:59 08:59 0.00 Pass Yes Tank # 4 Line # 1 TLD-1 4 Low Sulfur Diesel Pressure 60 07:57 08:57 0.00 Pass Yes Tank # 4 Line # 2 TLD-1 4 Low Sulfur Diesel Pressure 60 07:59 08:59 0.00 Pass Yes Technician Comments: UT151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com WALMART #3454 1200 S COMMERCE WAY BRIGHAM CITY UT 84302 WM3454 Tanknology, Inc. WALMART/SAM'S CLUB DEPT. 9641 2101 SE Simple Savings Dr. BENTONVILLE AR 72716 479-360-2779 09/17/2024 RUL RUL 2 Low Sulfur DieselVeeder Root DPLLD Veeder Root DPLLD Veeder Root DPLLD Veeder Root DPLLD 40 2 40 2 2 40 40 2 UT151 David Mathie NW1-2371456 PREMIUM T1:1 T2:1 T3:1 T4:1 Impact Valve Inspection Impact Valve Operational Inspection Work Order:2371456 Date:9/17/2024 Site Name/ID:WALMART #3454 Address:1200 S COMMERCE WAY City:BRIGHAM CITY State:UT Zip:84302 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 40 Pass Fail Not Tested 1/2 85 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 85 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 85 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 40 Pass Fail Not Tested 7/8 85 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested 9/10 40 Pass Fail Not Tested 9/10 85 Pass Fail Not Tested 9/10 91 Pass Fail Not Tested 11/12 85 Pass Fail Not Tested 11/12 91 Pass Fail Not Tested 13/14 85 Pass Fail Not Tested 13/14 91 Pass Fail Not Tested 15/16 40 Pass Fail Not Tested 15/16 85 Pass Fail Not Tested 15/16 91 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com WALMART #3454 WALMART/SAM'S CLUB 1200 S COMMERCE WAY BRIGHAM CITY UT 84302 WM3454 Tanknology, Inc. DEPT. 9641 2101 SE Simple Savings Dr. BENTONVILLE AR 72716 479-360-2779 800-964-1250 09/17/2024 1 2 3 4 RUL RUL2 PREM DSL VR450PLUS VR450PLUS VR450PLUS VR450PLUS 19782 11904 7901 10420 118.4 118.4 118.4 118.40 UT151 David Mathie 1200 S COMMERCE WAY WALMART #3454 1200 S COMMERCE WAY, BRIGHAM CITY, UT 84302 WM3454 Tanknology, Inc. WALMART/SAM'S CLUB DEPT. 9641 2101 SE Simple Savings Dr. BENTONVILLE, AR 72716 479-360-2779 09/17/2024 ANNULAR ANNULAR ANNULAR STP STP STP STP RUL RUL2/PREM DSL RUL1 RUL2 PREM DSL UT151 David Mathie 1200 S COMMERCE WAY WALMART #3454 1200 S COMMERCE WAY, BRIGHAM CITY, UT 84302 WM3454 Tanknology, Inc. WALMART/SAM'S CLUB DEPT. 9641 2101 SE Simple Savings Dr. BENTONVILLE, AR 72716 479-360-2779 09/17/2024 UDC UDC UDC UDC UDC UDC UDC 1//2 3/4 5/6 7/8 9/10 11/12 13/14 UT151 David Mathie 1200 S COMMERCE WAY WALMART #3454 1200 S COMMERCE WAY, BRIGHAM CITY, UT 84302 WM3454 Tanknology, Inc. WALMART/SAM'S CLUB DEPT. 9641 2101 SE Simple Savings Dr. BENTONVILLE, AR 72716 479-360-2779 09/17/2024 UDC 15/16 UT151 David Mathie WALMART #3454 1200 S COMMERCE WAY BRIGHAM CITY, UT 84302 WM3454 Tanknology, Inc. WALMART/SAM'S CLUB 479-360-2779 09/17/2024 DEPT. 9641 2101 SE Simple Savings Dr. BENTONVILLE, AR 72716 1 RUL 5 OPW 2 RUL2 5 OPW 3 PREM 5 OPW 4 DSL 5 OPW 15WC 646 15WC 651 5 MIN 0 15 WC 653 15 WC 658 5 MIN 0 15WC 700 15WC 705 5 MIN 0 15 WC 707 15WC 712 5MIN 0 UT151 David Mathie Stage I Vapor System Survey Survey to determine compliance with Requirements of Title 40 Part 63 National Emission Standards for Hazardous Air Pollutants for Source Categories Survey Date 9/17/2024 Work Order 2371456 Cust Name / Location Number WM3454 Street Address 1200 S COMMERCE WAY City, State, ZipCode BRIGHAM CITY UT 84302 Product Stage I Type Drop Tubes Type Drop Tubes Max inches from tank Bottom Fill Adapters Type Vapor Adapters Type NESHAP Work Required? Vent Caps Type Labeled Positive Cracking Pressure Labeled Negative Cracking Pressure 1 RUL Dual Point Straight w/ Flapper 6.00 Swivel Swivel (poppet) No GAS Pressure Vacuum cap 3 8 2 RUL 2 Dual Point Straight w/ Flapper 6.00 Swivel Swivel (poppet) No 3 PREMIUM Dual Point Straight w/ Flapper 6.00 Swivel Swivel (poppet) No Describe Work Required Surveyed by Signature ANNUAL CONTAINMENT SUMP INSPECTION This form may be utilized to document the inspection of containment sumps. Date of Inspection 9/17/2024 UST Facility Person Conducting Test Facility Name WALMART #3454 Facility ID # WM3454 Tester's Name DMATHIE Physical Address 1200 S COMMERCE WAY Company Tanknology Inc. City BRIGHAM CITY County BOX ELDER State UT Certification # 41442 Expiration Date 10/20/2025 UST Owner WALMART/SAM'S CLUB Tester's Signature Date 9/17/2024 Containment Sump Inspection Sump Material of Construction Fiberglass Reinforced Plastic Thermoplastic Steel Composite Containment Sump Inspection Procedure 1. Clean-out and properly dispose of all debris, soil and/or fluids from the containment sump. 2. Visually examine the containment sump to ensure there are no cracks, holes, deteriorated seals, deformation or other indications that the sump is not liquid tight. 3. If the sump appears to be liquid tight and no water was in the sump, the inspection result is "pass" and no further action is required. 4. If the sump appears to be liquid tight but water was present within the sump, the inspection result is "fail". 5. If there is visual evidence that the sump is not liquid tight, then repair or replacement (see note below) of the sump is required. Inspection Results for the Year 2024 Sump ID (product stored for STP or dispenser number) Sump lid/gasket in good condition (yes/no) Sump is dry (yes/no) All penetration fittings in good condition (yes/no) Sump walls/bottom in good condition (yes/no) Are there any leaks from pipe components (yes/no) Inspection Result (Pass/Fail) STP:1 RUL - 1 Y Y Y Y N Pass STP:2 RUL 2 - 1 Y Y Y Y N Pass STP:3 PREMIUM - 1 Y Y Y Y N Pass STP:4 Low Sulfur Diesel - 1 Y Y Y Y N Pass Comments: WO: 2371456 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2371456 Site ID / Name:WM3454 / WALMART #3454 Address:1200 S COMMERCE WAY City:BRIGHAM CITY State:UT Zip:84302 W.O.# NW1-2371456 +AAE- I10100 09/17/24 9:32 885033 Walmart 3454 1120 south commmerce Brigham,Ut,84302 435-734-9660 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL +AAMAAQ- I90200 09/17/24 9:32 SOFTWARE REVISION LEVEL VERSION 33.53 SOFTWARE+ACM- 342005-010-H- CREATED - 23.04.17.20.07 +AAMAAQ- I20100 09/17/24 9:32 885033 Walmart 3454 1120 south commmerce Brigham,Ut,84302 435-734-9660 IN-TANK INVENTORY TANK PRODUCT VOLUME TC-VOLUME ULLAGE HEIGHT WATER TEMP 1 T1-Unleaded North 12380 12250 7402 70.64 0.00 75.01 2 T2-Unleaded South 7118 7040 4786 67.97 0.00 75.74 3 T3-Premium 2370 2348 5531 40.10 0.00 73.14 4 T4-Diesel 4599 4567 5821 54.18 0.00 75.32 +AAMAAQ- I30100 09/17/24 9:32 885033 Walmart 3454 1120 south commmerce Brigham,Ut,84302 435-734-9660 LIQUID STATUS REPORT SENSOR LOCATION STATUS 1 Unld T1 STP Sump Normal 2 Unld T2 STP Sump Normal 3 Prem T3 STP Sump Normal 4 Dies T4 STP Sump Normal 5 Unld T1 Int Space Normal 6 Unld/Prem T2/T3 Int Normal 7 Dies T4 Int Space Normal 8 Disp FP 1-2 Normal 9 Disp FP 3-4 Normal 10 Disp FP 5-6 Normal 11 Disp FP 7-8 Normal 12 Disp FP 15-16 Normal 13 Disp FP 13-14 Normal 14 Disp FP 11-12 Normal 15 Disp FP 9-10 Normal +AAMAAQ- I30200 09/17/24 9:33 885033 Walmart 3454 1120 south commmerce Brigham,Ut,84302 435-734-9660 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 Unld T1 STP Sump 09/17/24 7:40 FUEL ALARM 02/16/24 11:18 SENSOR OUT ALARM 02/16/24 11:17 FUEL ALARM 02/16/24 11:11 SENSOR OUT ALARM 02/16/24 9:45 SENSOR OUT ALARM 02/16/24 8:21 SENSOR OUT ALARM 02/16/24 8:18 SENSOR OUT ALARM 12/18/23 13:41 FUEL ALARM 2 Unld T2 STP Sump 09/17/24 7:42 FUEL ALARM 02/16/24 14:33 SENSOR OUT ALARM 02/16/24 11:56 SENSOR OUT ALARM 12/18/23 13:43 FUEL ALARM 12/05/23 8:19 FUEL ALARM 3 Prem T3 STP Sump 09/17/24 7:44 FUEL ALARM 12/18/23 13:44 FUEL ALARM 12/08/23 9:43 SENSOR OUT ALARM 12/06/23 8:37 FUEL ALARM 12/06/23 8:24 FUEL ALARM 12/05/23 8:14 FUEL ALARM 4 Dies T4 STP Sump 09/17/24 7:44 FUEL ALARM 02/16/24 13:57 SENSOR OUT ALARM 02/16/24 13:02 SENSOR OUT ALARM 02/16/24 12:15 SENSOR OUT ALARM 12/18/23 13:45 FUEL ALARM 12/12/23 12:59 FUEL ALARM 12/05/23 8:16 FUEL ALARM 5 Unld T1 Int Space 09/17/24 8:06 FUEL ALARM 12/18/23 11:01 FUEL ALARM 6 Unld/Prem T2/T3 Int 09/17/24 8:08 FUEL ALARM 12/18/23 11:54 FUEL ALARM 7 Dies T4 Int Space 09/17/24 8:19 FUEL ALARM 09/17/24 8:18 FUEL ALARM 12/18/23 12:08 FUEL ALARM 8 Disp FP 1-2 09/17/24 7:55 FUEL ALARM 12/18/23 13:54 FUEL ALARM 12/14/23 9:46 FUEL ALARM 12/05/23 8:36 FUEL ALARM 9 Disp FP 3-4 09/17/24 7:55 FUEL ALARM 12/18/23 13:55 FUEL ALARM 12/14/23 10:46 SENSOR OUT ALARM 12/14/23 10:41 FUEL ALARM 12/12/23 11:52 SENSOR OUT ALARM 12/12/23 11:49 SENSOR OUT ALARM 12/12/23 11:48 FUEL ALARM 12/05/23 8:37 FUEL ALARM 10 Disp FP 5-6 09/17/24 7:56 FUEL ALARM 12/18/23 13:55 FUEL ALARM 12/14/23 9:47 FUEL ALARM 12/05/23 8:41 FUEL ALARM 11 Disp FP 7-8 09/17/24 7:56 FUEL ALARM 12/18/23 14:07 FUEL ALARM 12/18/23 13:55 FUEL ALARM 12/14/23 9:48 FUEL ALARM 12/05/23 8:42 FUEL ALARM 12 Disp FP 15-16 09/17/24 7:58 FUEL ALARM 12/18/23 14:09 FUEL ALARM 12/14/23 10:20 FUEL ALARM 12/14/23 9:51 FUEL ALARM 12/05/23 8:56 FUEL ALARM 12/05/23 8:55 SENSOR OUT ALARM 12/05/23 6:54 FUEL ALARM 13 Disp FP 13-14 09/17/24 7:57 FUEL ALARM 12/18/23 14:08 FUEL ALARM 12/14/23 10:19 FUEL ALARM 12/14/23 9:50 FUEL ALARM 12/05/23 8:40 FUEL ALARM 14 Disp FP 11-12 09/17/24 7:57 FUEL ALARM 02/22/24 2:28 FUEL ALARM 12/18/23 14:08 FUEL ALARM 12/14/23 10:19 FUEL ALARM 12/14/23 9:49 FUEL ALARM 12/05/23 8:39 FUEL ALARM 15 Disp FP 9-10 09/17/24 7:56 FUEL ALARM 12/18/23 14:08 FUEL ALARM 12/15/23 14:25 FUEL ALARM 12/14/23 10:18 FUEL ALARM 12/14/23 9:48 FUEL ALARM 12/05/23 8:35 FUEL ALARM +AAMAAQ- I38200 09/17/24 9:33 885033 Walmart 3454 1120 south commmerce Brigham,Ut,84302 435-734-9660 PRESSURE LINE LEAK ALARM HISTORY REPORT Ln 1: Unleaded 1 PLLD SHUTDOWN ALARM 09/17/24 7:35 GROSS LINE FAIL 09/17/24 7:35 PLLD OPEN ALARM 09/13/24 18:17 PLLD OPEN ALARM 09/08/24 19:34 PLLD OPEN ALARM 09/06/24 15:04 PLLD OPEN ALARM 02/16/24 9:48 PLLD OPEN ALARM 02/16/24 8:43 PLLD OPEN ALARM 02/16/24 8:18 PLLD SHUTDOWN ALARM 12/18/23 14:50 GROSS LINE FAIL 12/18/23 14:50 Ln 2: Unleaded 2 PLLD SHUTDOWN ALARM 09/17/24 7:34 GROSS LINE FAIL 09/17/24 7:34 PLLD OPEN ALARM 09/12/24 17:37 PLLD OPEN ALARM 09/12/24 12:08 PLLD OPEN ALARM 09/10/24 17:46 PLLD OPEN ALARM 09/08/24 18:08 PLLD OPEN ALARM 09/08/24 18:08 PLLD OPEN ALARM 02/16/24 14:35 PLLD OPEN ALARM 02/16/24 13:20 PLLD OPEN ALARM 02/16/24 12:31 PLLD OPEN ALARM 02/16/24 11:59 PLLD SHUTDOWN ALARM 12/18/23 14:55 GROSS LINE FAIL 12/18/23 14:55 Ln 3: Premium PLLD SHUTDOWN ALARM 09/17/24 7:33 GROSS LINE FAIL 09/17/24 7:33 PLLD OPEN ALARM 09/12/24 15:40 PLLD OPEN ALARM 09/09/24 22:44 PLLD OPEN ALARM 09/07/24 13:47 PLLD OPEN ALARM 09/06/24 20:16 PLLD SHUTDOWN ALARM 09/04/24 8:37 GROSS LINE FAIL 09/04/24 8:37 PLLD SHUTDOWN ALARM 09/03/24 17:45 GROSS LINE FAIL 09/03/24 17:45 GROSS LINE FAIL 09/03/24 15:43 PLLD SHUTDOWN ALARM 09/03/24 15:43 PLLD SHUTDOWN ALARM 09/03/24 11:50 GROSS LINE FAIL 09/03/24 11:50 GROSS LINE FAIL 09/03/24 5:46 PLLD SHUTDOWN ALARM 09/03/24 5:46 PLLD OPEN ALARM 06/13/24 14:51 PLLD SHUTDOWN ALARM 06/13/24 14:28 GROSS LINE FAIL 06/13/24 14:28 GRS TST NEEDED ALM 01/03/24 16:34 GROSS LINE FAIL 12/18/23 14:59 PLLD SHUTDOWN ALARM 12/18/23 14:59 GROSS LINE FAIL 12/15/23 14:32 PLLD SHUTDOWN ALARM 12/15/23 14:32 Ln 4: Diesel PLLD SHUTDOWN ALARM 09/17/24 7:31 GROSS LINE FAIL 09/17/24 7:31 PLLD OPEN ALARM 02/16/24 14:19 PLLD OPEN ALARM 02/16/24 13:59 PLLD OPEN ALARM 02/16/24 12:16 GRS TST NEEDED ALM 01/01/24 16:34 GROSS LINE FAIL 12/18/23 15:08 PLLD SHUTDOWN ALARM 12/18/23 15:08 GROSS LINE FAIL 12/12/23 12:13 PLLD SHUTDOWN ALARM 12/12/23 12:13 +AAMAAQ- I6SU00 09/17/24 9:33 -------------------------------------------------------- +ACoAKgAq- SETUP FOR ALL TANKS +ACoAKgAq- -------------------------------------------------------- ULLAGE DISPLAY MODE: FULL ULLAGE USER ULLAGE FULL ULLAGE LABEL: 100+ACU- ULLAGE USER ULLAGE: 90+ACU- PRINT TC VOLUMES: ENABLED TC REFERENCE TEMPERATURE: 60 DEG F PERIODIC TEST NEEDED WARNINGS: DISABLED DAYS BEFORE PERIODIC WARNING: 25 DAYS BEFORE PERIODIC ALARM: 30 ANNUAL TEST NEEDED WARNINGS: DISABLED DAYS BEFORE ANNUAL WARNING: 355 DAYS BEFORE ANNUAL ALARM: 365 TC DENSITY: DISABLED STICK HEIGHT: DISABLED LEAK TEST REPORT FORMAT: STANDARD LEAK TEST REGION: EPA -------------------------------------------------------- +ACoAKgAq- TANK SETUP +ACoAKgAq- -------------------------------------------------------- --- GENERAL SETUP - TANK 1 --- CONFIGURED: ENABLED LABEL: T1-Unleaded North PRODUCT CODE: 1 PROBE NUMBER: Pb 1: Unld Tk +ACM- 1 Probe PROBE OFFSET: 0.00 INCHES FULL VOLUME: 19782 GALLONS DIAMETER: 118.4 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000700 METER DATA PRESENT: ENABLED DELIVERY DELAY: 5 MINUTES GROSS TEST FAIL: ALARMS DISABLED PERIODIC TEST FAIL: ALARMS DISABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 1 --- MAX VOLUME: 19782 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 0+ACU- LOW PRODUCT: 536 GALLONS HIGH WATER WARNING: 1.00 INCHES HIGH WATER ALARM: 3.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 15 GALLONS SUDDEN LOSS LIMIT: 50 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 1 --- TANK TEST METHOD: DISABLED --- PROFILE - TANK 1 --- TANK PROFILE: FOUR POINT +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 118.4 19782 003 59.2 9883 002 88.8 16039 004 29.6 3735 --- TANK 1 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: FOUR POINT SOURCE: USER ENTERED LAST CHANGE: 2023-12-07 STATUS: ACTIVE VOLUME ENTRY: TOTAL VOLUME +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 118.4 19782 003 59.2 9883 002 88.8 16039 004 29.6 3735 --- TANK 1 --- T1 SIPHON MANIFOLDED TO TANKS: 2 T1 LINE MANIFOLDED TO TANKS: NONE --- ACCUCHART - TANK 1 --- UPDATE SCHEDULE: NEVER CALIBRATION PERIOD: 120 DAYS WARNINGS: ENABLED MIN OPERATING LEVEL: 10+ACU- MAX OPERATING LEVEL: 80+ACU- --- HRM - TANK 1 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS --- GENERAL SETUP - TANK 2 --- CONFIGURED: ENABLED LABEL: T2-Unleaded South PRODUCT CODE: 2 PROBE NUMBER: Pb 2: Unld Tk +ACM- 2 Probe PROBE OFFSET: 0.00 INCHES FULL VOLUME: 11904 GALLONS DIAMETER: 118.4 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000700 METER DATA PRESENT: ENABLED DELIVERY DELAY: 5 MINUTES GROSS TEST FAIL: ALARMS DISABLED PERIODIC TEST FAIL: ALARMS DISABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 2 --- MAX VOLUME: 11904 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 0+ACU- LOW PRODUCT: 536 GALLONS HIGH WATER WARNING: 1.00 INCHES HIGH WATER ALARM: 3.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 15 GALLONS SUDDEN LOSS LIMIT: 50 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 2 --- TANK TEST METHOD: DISABLED --- PROFILE - TANK 2 --- TANK PROFILE: FOUR POINT +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 118.4 11904 003 59.2 5936 002 88.8 9700 004 29.6 2183 --- TANK 2 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: FOUR POINT SOURCE: USER ENTERED LAST CHANGE: 2023-12-07 STATUS: ACTIVE VOLUME ENTRY: TOTAL VOLUME +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 118.4 11904 003 59.2 5936 002 88.8 9700 004 29.6 2183 --- TANK 2 --- T2 SIPHON MANIFOLDED TO TANKS: 1 T2 LINE MANIFOLDED TO TANKS: NONE --- ACCUCHART - TANK 2 --- UPDATE SCHEDULE: NEVER CALIBRATION PERIOD: 120 DAYS WARNINGS: ENABLED MIN OPERATING LEVEL: 10+ACU- MAX OPERATING LEVEL: 80+ACU- --- HRM - TANK 2 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS --- GENERAL SETUP - TANK 3 --- CONFIGURED: ENABLED LABEL: T3-Premium PRODUCT CODE: 3 PROBE NUMBER: Pb 3: Prem Tk +ACM- 3 Probe PROBE OFFSET: 0.00 INCHES FULL VOLUME: 7901 GALLONS DIAMETER: 118.4 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000700 METER DATA PRESENT: ENABLED DELIVERY DELAY: 5 MINUTES GROSS TEST FAIL: ALARMS DISABLED PERIODIC TEST FAIL: ALARMS DISABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 3 --- MAX VOLUME: 7901 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 0+ACU- LOW PRODUCT: 536 GALLONS HIGH WATER WARNING: 1.00 INCHES HIGH WATER ALARM: 3.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 15 GALLONS SUDDEN LOSS LIMIT: 50 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 3 --- TANK TEST METHOD: DISABLED --- PROFILE - TANK 3 --- TANK PROFILE: FOUR POINT +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 118.4 7901 003 59.2 3959 002 88.8 6365 004 29.6 1558 --- TANK 3 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: FOUR POINT SOURCE: USER ENTERED LAST CHANGE: 2023-12-06 STATUS: ACTIVE VOLUME ENTRY: TOTAL VOLUME +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 118.4 7901 003 59.2 3959 002 88.8 6365 004 29.6 1558 --- TANK 3 --- T3 SIPHON MANIFOLDED TO TANKS: NONE T3 LINE MANIFOLDED TO TANKS: NONE --- ACCUCHART - TANK 3 --- UPDATE SCHEDULE: NEVER CALIBRATION PERIOD: 120 DAYS WARNINGS: ENABLED MIN OPERATING LEVEL: 10+ACU- MAX OPERATING LEVEL: 80+ACU- --- HRM - TANK 3 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS --- GENERAL SETUP - TANK 4 --- CONFIGURED: ENABLED LABEL: T4-Diesel PRODUCT CODE: 4 PROBE NUMBER: Pb 4: Dies Tk +ACM- 4 Probe PROBE OFFSET: 0.00 INCHES FULL VOLUME: 10420 GALLONS DIAMETER: 118.4 INCHES TILT: 0.00 INCHES THERMAL COEFFICIENT: 0.000450 METER DATA PRESENT: ENABLED DELIVERY DELAY: 5 MINUTES GROSS TEST FAIL: ALARMS DISABLED PERIODIC TEST FAIL: ALARMS DISABLED ANNUAL TEST FAIL: ALARMS DISABLED GOST VOLUME CORRECTION: DISABLED --- LIMITS - TANK 4 --- MAX VOLUME: 10420 GALLONS HIGH PRODUCT: 95+ACU- DELIVERY OVERFILL: 90+ACU- DELIVERY LIMIT: 0+ACU- LOW PRODUCT: 536 GALLONS HIGH WATER WARNING: 1.00 INCHES HIGH WATER ALARM: 3.00 INCHES WATER ALARM FILTER LEVEL: LOW LEAK ALARM LIMIT: 15 GALLONS SUDDEN LOSS LIMIT: 50 GALLONS FUEL LOW TEMP LIMIT: -58.000 DEG F FUEL HIGH TEMP LIMIT: 140.000 DEG F --- ENVIRONMENTAL TESTS - TANK 4 --- TANK TEST METHOD: DISABLED --- PROFILE - TANK 4 --- TANK PROFILE: FOUR POINT +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 118.4 10420 003 59.2 5195 002 88.8 8508 004 29.6 1890 --- TANK 4 - CHART 1 --- LABEL: +ACoAKgAqACoAKg- TYPE: FOUR POINT SOURCE: USER ENTERED LAST CHANGE: 2023-12-07 STATUS: ACTIVE VOLUME ENTRY: TOTAL VOLUME +ACM- HEIGHT VOLUME +ACM- HEIGHT VOLUME --- ------ ------ --- ------ ------ 001 118.4 10420 003 59.2 5195 002 88.8 8508 004 29.6 1890 --- TANK 4 --- T4 SIPHON MANIFOLDED TO TANKS: NONE T4 LINE MANIFOLDED TO TANKS: NONE --- ACCUCHART - TANK 4 --- UPDATE SCHEDULE: NEVER CALIBRATION PERIOD: 120 DAYS WARNINGS: ENABLED MIN OPERATING LEVEL: 10+ACU- MAX OPERATING LEVEL: 80+ACU- --- HRM - TANK 4 --- WARNING LIMIT: 1 GALLONS ALARM LIMIT: 1 GALLONS MAXIMUM VOLUME LIMIT: 132 GALLONS +AAMAAQ- I70300 09/17/24 9:33 LIQUID MODEL SENSOR LABEL MODEL 1 Unld T1 STP Sump Tri-State(Single Float) 2 Unld T2 STP Sump Tri-State(Single Float) 3 Prem T3 STP Sump Tri-State(Single Float) 4 Dies T4 STP Sump Tri-State(Single Float) 5 Unld T1 Int Space Tri-State(Single Float) 6 Unld/Prem T2/T3 Int Tri-State(Single Float) 7 Dies T4 Int Space Tri-State(Single Float) 8 Disp FP 1-2 Tri-State(Single Float) 9 Disp FP 3-4 Tri-State(Single Float) 10 Disp FP 5-6 Tri-State(Single Float) 11 Disp FP 7-8 Tri-State(Single Float) 12 Disp FP 15-16 Tri-State(Single Float) 13 Disp FP 13-14 Tri-State(Single Float) 14 Disp FP 11-12 Tri-State(Single Float) 15 Disp FP 9-10 Tri-State(Single Float) 16 Tri-State(Single Float) 17 Tri-State(Single Float) 18 Tri-State(Single Float) 19 Tri-State(Single Float) 20 Tri-State(Single Float) 21 Tri-State(Single Float) 22 Tri-State(Single Float) 23 Tri-State(Single Float) 24 Tri-State(Single Float) 25 Tri-State(Single Float) 26 Tri-State(Single Float) 27 Tri-State(Single Float) 28 Tri-State(Single Float) 29 Tri-State(Single Float) 30 Tri-State(Single Float) 31 Tri-State(Single Float) 32 Tri-State(Single Float) 33 Tri-State(Single Float) 34 Tri-State(Single Float) 35 Tri-State(Single Float) 36 Tri-State(Single Float) 37 Tri-State(Single Float) 38 Tri-State(Single Float) 39 Tri-State(Single Float) 40 Tri-State(Single Float) 41 Tri-State(Single Float) 42 Tri-State(Single Float) 43 Tri-State(Single Float) 44 Tri-State(Single Float) 45 Tri-State(Single Float) 46 Tri-State(Single Float) 47 Tri-State(Single Float) 48 Tri-State(Single Float) 49 Tri-State(Single Float) 50 Tri-State(Single Float) 51 Tri-State(Single Float) 52 Tri-State(Single Float) 53 Tri-State(Single Float) 54 Tri-State(Single Float) 55 Tri-State(Single Float) 56 Tri-State(Single Float) 57 Tri-State(Single Float) 58 Tri-State(Single Float) 59 Tri-State(Single Float) 60 Tri-State(Single Float) 61 Tri-State(Single Float) 62 Tri-State(Single Float) 63 Tri-State(Single Float) 64 Tri-State(Single Float) 65 Tri-State(Single Float) 66 Tri-State(Single Float) 67 Tri-State(Single Float) 68 Tri-State(Single Float) 69 Tri-State(Single Float) 70 Tri-State(Single Float) 71 Tri-State(Single Float) 72 Tri-State(Single Float) 73 Tri-State(Single Float) 74 Tri-State(Single Float) 75 Tri-State(Single Float) 76 Tri-State(Single Float) 77 Tri-State(Single Float) 78 Tri-State(Single Float) 79 Tri-State(Single Float) 80 Tri-State(Single Float) 81 Tri-State(Single Float) 82 Tri-State(Single Float) 83 Tri-State(Single Float) 84 Tri-State(Single Float) 85 Tri-State(Single Float) 86 Tri-State(Single Float) 87 Tri-State(Single Float) 88 Tri-State(Single Float) 89 Tri-State(Single Float) 90 Tri-State(Single Float) 91 Tri-State(Single Float) 92 Tri-State(Single Float) 93 Tri-State(Single Float) 94 Tri-State(Single Float) 95 Tri-State(Single Float) 96 Tri-State(Single Float) 97 Tri-State(Single Float) 98 Tri-State(Single Float) 99 Tri-State(Single Float) +AAMAAQ- I78000 09/17/24 9:33 PRESSURE LINE LEAK SETUP Q 1: Unleaded 1 PIPE TYPE: OPW Pisces SP-15 LINE LENGTH: 100 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: ON LOW PRESSURE: 10.0 psi TANK: 1 - T1-Unleaded North PRESSURE OFFSET: 0.0 psi Q 2: Unleaded 2 PIPE TYPE: OPW Pisces SP-15 LINE LENGTH: 105 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: ON LOW PRESSURE: 10.0 psi TANK: 2 - T2-Unleaded South PRESSURE OFFSET: 0.0 psi Q 3: Premium PIPE TYPE: OPW Pisces SP-15 LINE LENGTH: 215 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: ON LOW PRESSURE: 10.0 psi TANK: 3 - T3-Premium PRESSURE OFFSET: 0.0 psi Q 4: Diesel PIPE TYPE: OPW Pisces SP-15 LINE LENGTH: 250 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: ON LOW PRESSURE: 10.0 psi TANK: 4 - T4-Diesel PRESSURE OFFSET: 0.0 psi Q 5: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 6: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 7: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 8: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 9: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 10: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 11: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 12: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 13: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 14: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 15: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi Q 16: PIPE TYPE: Enviroflex PP1503/2503 LINE LENGTH: 0 FEET 0.2 GAL/HR TEST: DISABLED 0.1 GAL/HR TEST: DISABLED SHUTDOWN RATE: 3.0 GAL/HR LOW PRESSURE SHUTOFF: OFF LOW PRESSURE: 0.0 psi TANK: NONE PRESSURE OFFSET: 0.0 psi +AAMAAQ- IB0100 09/17/24 9:33 SENSOR DIAGNOSTIC - LIQUID SENSOR INFORMATION REPORT SAMPLE SENSOR CATEGORY COUNTER VALUE STATUS 1 STP Sump 5 100363 Normal 2 STP Sump 5 100148 Normal 3 STP Sump 5 99291 Normal 4 STP Sump 5 100540 Normal 5 Annular Space 5 99803 Normal 6 Annular Space 5 100283 Normal 7 Annular Space 5 100042 Normal 8 Dispenser Pan 5 100298 Normal 9 Dispenser Pan 5 99905 Normal 10 Dispenser Pan 5 100739 Normal 11 Dispenser Pan 5 100647 Normal 12 Dispenser Pan 5 100011 Normal 13 Dispenser Pan 5 96654 Normal 14 Dispenser Pan 5 100576 Normal 15 Dispenser Pan 5 100713 Normal