HomeMy WebLinkAboutDERR-2024-011029 WESTECH EQUIPMENT 195 WEST 3900 SOUTH • P.O. BOX 57307 • SALT LAKE CITY, UTAH 84157-0307 801-266-2545 • TOLL FREE 800-433-8831 • 24 HOUR FAX 801-261-4054 PRODUCT PIPING INTEGRITY TESTING Facility Name: Meadowbrook Golf Course Owner: Salt Lake County Fleet Management Address: 4197 South 1300 West Address: 7125 South 600 West City, State, Zip: Salt Lake City, Utah 84123 City, State, Zip: Midvale, Utah 84047 Facility I.D.#: 4000877 Phone #: 385-468-0486 Testing Company: Westech Phone #: 801-266-2545 Date: 9/11/24 This procedure is to test the integrity of product piping. Tests were performed with Petro-Tite line tester. Tank Number 1 2 Product Stored DSL RUL Piping Run Only Only Piping Type FRP D/W FRP D/W Test Pressure (PSI) 5 5 Test Duration (minutes) 30 30 Leak Rate (GPH) 0.000 0.000 Test Results ☒Pass ☐Fail ☒Pass ☐Fail ☐Pass ☐Fail ☐Pass ☐Fail Comments: Tester’s Name Taber DeHart, UT-0394 Tester’s Signature RU L DS L WESTECH EQUIPMENT 195 WEST 3900 SOUTH • P.O. BOX 57307 • SALT LAKE CITY, UTAH 84157-0307 801-266-2545 • TOLL FREE 800-433-8831 • 24 HOUR FAX 801-261-4054 MECHANICAL AND ELECTRONIC LINE LEAK DETECTOR PERFORMANCE TESTS Facility Name: Meadowbrook Golf Course Owner: Salt Lake County Fleet Management Address: 4197 South 1300 West Address: 7125 South 600 West City, State, Zip: Salt Lake City, Utah 84123 City, State, Zip: Midvale, Utah 84047 Facility I.D.#: 4000877 Phone #: 385-468-0486 Testing Company: Westech Phone #: 801-266-2545 Date: 9/11/24 This data sheet can be used to test the mechanical line leak detector (MLLD) and electronic line leak detector (ELLD) with submersible turbine pump (STP) systems. See PEI/RP 1200 Sections 9.1 and 9.2 for test procedures. Line Number 1 2 Product Stored DSL RUL Leak Detector Manufacturer Red Jacket Red Jacket Leak Detector Model FX1DV FX1V Type Of leak Detector ☒MLLD ☐ELLD ☒MLLD ☐ELLD ☐MLLD ☐ELLD ☐MLLD ☐ELLD MLLD (ALL PRESSURE MEASURMENTS ARE MADE IN PSIG) STP full operating pressure 29 29 Check valve holding pressure 19 21 Line resiliency (ml) (line bleedback volume as measured from check valve holding pressure to 0 psig) 40 55 Step through time in seconds (time the MLLD hesitates at metering pressure before going to full operating pressure as measured from 0 sig with no leak induced on the line) 5 1 Metering pressure (STP pressure when simulated leak rate 3 gph at 10 psig) 18 11 Opening time in seconds (the time the MLLD opens to allow full pressure after simulated leak is stopped) 2 2 Does the STP pressure remain at or below the metering pressure for at least 60 seconds when the simulated leak is induced? ☒Yes ☐No ☒Yes ☐No ☐Yes ☐No ☐Yes ☐No Does the leak detector reset (trip) when the line pressure is bled off to zero psig? ☒Yes ☐No ☒Yes ☐No ☐Yes ☐No ☐Yes ☐No Does STP properly clycle on/off under normal fuel system operating conditions? ☒Yes ☐No ☒Yes ☐No ☐Yes ☐No ☐Yes ☐No A "No" answer to any of the above questions indicates that the MLLD fails the test. ELLD (ALL PRESSURE MEASURMENTS ARE MADE IN PSIG) STP full operating pressure How many test cycles are observed before alarm/shutdown occurs? Does the simulated leak cause on alarm? ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No A "No" answer to the above question indicates that the ELLD fails the test. Does the simulated leak cause an STP shutdown? ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No ☐Yes ☐No Test Results ☒Pass ☐Fail ☒Pass ☐Fail ☐Pass ☐Fail ☐Pass ☐Fail Comments: Tester’s Name Taber DeHart, UT-0394 Tester’s Signature WESTECH EQUIPMENT 195 WEST 3900 SOUTH • P.O. BOX 57307 • SALT LAKE CITY, UTAH 84157-0307 801-266-2545 • TOLL FREE 800-433-8831 • 24 HOUR FAX 801-261-4054 AUTOMATIC TANK GAUGE OPERATION INSPECTION Facility Name: Meadowbrook Golf Course Owner: Salt Lake County Fleet Management Address: 4197 South 1300 West Address: 7125 South 600 West City, State, Zip: Salt Lake City, Utah 84123 City, State, Zip: Midvale, Utah 84047 Facility I.D.#: 4000877 Phone #: 385-468-0486 Testing Company: Westech Phone #: 801-266-2545 Date: 9/11/24 This procedure is to determine whether the automatic tank gauge (ATG) is operating properly. See PEI/RP1200 Section 8.2 for the inspection procedure. This procedure is applicable to tank monitor stems the touch the bottom of the tank when in place. Tank Number 1 2 Product Stored DSL RUL ATG Brand and Model TLS 300 TLS 300 1. Tank Volume, gallons 2,319 2,319 2. Tank Diameter, inches 69.6 69.6 3. After removing the ATG from the tank, it has been inspected and any damaged or missing parts replaced? ☒Yes ☐No ☒Yes ☐No ☐Yes ☐No ☐Yes ☐No 4. Float moves freely on the stem without binding? ☒Yes ☐No ☒Yes ☐No ☐Yes ☐No ☐Yes ☐No 5. Fuel float level agree with the value programmed into the console? ☒Yes ☐No ☒Yes ☐No ☐Yes ☐No ☐Yes ☐No 6. Water float level agree with the value programmed into the console? ☒Yes ☐No ☒Yes ☐No ☐Yes ☐No ☐Yes ☐No 7. Inch level from the bottom of the stem when 90% alarm is triggered? 57 3/4 57 3/4 8. Inch level at which the overfill alarm activates corresponds with the value programmed in the gauge? ☒Yes ☐No ☒Yes ☐No ☐Yes ☐No ☐Yes ☐No 9. Inch level from the bottom when the water float first triggers an alarm? 1.5 1.5 10. Inch level at which the water float alarm activates corresponds with the value programmed in the gauge? ☒Yes ☐No ☒Yes ☐No ☐Yes ☐No ☐Yes ☐No If any answers in Lines 3, 4, 5, or 6 are "No" the system has failed the test. Test Results ☒Pass ☐Fail ☒Pass ☐Fail ☐Pass ☐Fail ☐Pass ☐Fail Comments: Battery OK Tester’s Name Taber DeHart, UT-0394 Tester’s Signature WESTECH EQUIPMENT 195 WEST 3900 SOUTH • P.O. BOX 57307 • SALT LAKE CITY, UTAH 84157-0307 801-266-2545 • TOLL FREE 800-433-8831 • 24 HOUR FAX 801-261-4054 PRESSURE/VACUUM VENT CAP LEAK RATES AND OPENING PRESSURES Facility Name: Meadowbrook Golf Course Owner: Salt Lake County Fleet Management Address: 4197 South 1300 West Address: 7125 South 600 West City, State, Zip: Salt Lake City, Utah 84123 City, State, Zip: Midvale, Utah 84047 Facility I.D.#: 4000877 Phone #: 385-468-0486 Testing Company: Westech Phone #: 801-266-2545 Date: 9/11/24 This procedure is to determine pressure/vent cap specifications. See 40 CFR 63 CCCCCC for the inspection procedure. Tank Number 2 Product Grade RUL PV Manufacturer OPW Model Number 623V PRESSURE TEST Passing 2” Leak Rate (CFH) <0.05 Measured 2” Leak Rate (CFH) New Cap Passing Positive Opening Pressure (Inches WC) 2.5 – 6.0 Measured Positive Opening Pressure (Inches WC) New Cap VACUUM TEST Passing -4” Leak Rate (CFH) <0.21 Measured -4” Leak Rate (CFH) New Cap Passing Negative Opening Pressure (Inched WC) 6.0 – 10.0 Measured Negative Opening Pressure (Inched WC) New Cap Test Results ☒Pass ☐Fail ☐Pass ☐Fail ☐Pass ☐Fail ☐Pass ☐Fail Comments: New cap Installed 9/11/24. Tester’s Name Taber DeHart, UT-0394 Tester’s Signature