HomeMy WebLinkAboutDDW-2024-011224Bicknell Town Capacity Calcs.xlsx Page 1 of 9/23/2024 Division of Drinking Water — Water System Capacity Calculation Sheet (Last Update 3/30/2017) *Enter the green cells only* System Name Bicknell Town Water System System Number 28001 1.1 Indoor Water Use Number of residential connections - - - - - - - - - - -- - - - - - - - - - - - - - - - - - -- - - - - - - - -180 Number of other connections - - - 69 ERCs of other connections 79.0 Total Equivalent Residential Connections (ERCs)259.0 MIN. REQUIREMENTS FOR INDOOR WATER USE Source Storage gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 800 143.9)400 (103,600) 1.2 Outdoor Water Use Is the drinking water used for outdoor irrigation? Residential ERCs using drinking water for irrigation - - - - - - - - - - - - > > >200 Percentage of Residential ERCs using DW for irrigation - - - - - - - - - - - - > > >111% Average irrigated acreage per residential connection - - - - - - - - - - - - > > >0.05 Total irrigated acreage of other connections (park, school, etc.)- - - - - - - - - - - - > > >10.00 (Enter notes here regarding whether and what % of irrigation water is supplied by PWS.) Irrigation zone 3 MIN. REQUIREMENTS FOR IRRIGATION USE Source Storage gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 244 67.8 126 50,560 1.3 Fire Flow Water Use Does the water system provide fire protection? Maximum fire flow demand (in gpm) for water system or pressure zone 1,000 Maximum fire suppression duration (in hours) for water system or pressure zone 1 Required Fire Suppression Storage (in gallons) - - - - - - - - - - - - - - - - - - - - > > >60,000 (*Verify req'd fire flow and duration with local fire code officials.* Enter notes here, e.g. fire official contact info or comments.) 2. Summary of Water System Capacity Requirements MINIMUM REQUIREMENTS FOR WATER SYSTEM Source (indoor + outdoor)Storage (indoor + outdoor + fire) gpd/ERC Total (gpm)Gallons/ERC Total (gallons) 1,044 211.7 526 214,160 2.1 Does this system have adequate source capacity (per R309-510-7)? This source capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Required Source Capacity 211.7 gpm Existing Source Capacity 195.0 gpm Source Capacity Deficit 16.7 gpm Existing % of Total Req'd 92.1% Bicknell Town Capacity Calcs.xlsx Page 2 of 9/23/2024 2.2 Does this system have adequate storage capacity (per R309-510-8)? This storage capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Total Required Storage 214,160 gal Existing Storage Capacity 620,000 gal Storage Capacity Deficit None gal Required Fire Storage 60,000 gal Is storage deficiency solely due to fire storage?Not Applicable Existing % of Total Req'd 289.5% 3. Transient PWS Indoor Water Use — ERC Calcuation (See R309-510, Tables 510-1, 2, & 4 for other facility types.) MINIMUM REQUIREMENTS FOR INDOOR USE Source Storage Facility Type GPD/person*GPD/site or pad Gallons/person Gallon/site or pad ERC/site or pad Modern Recreation Camp 60 240 30 120 0.30 Semi-Developed Camp w/ flush toilets 20 80 10 40 0.10 Semi-Developed Camp w/o flush toilets 5 20 2.5 10 0.03 RV Park N/A 100 N/A 50 0.13 Number of people per camp site 4 Source (GPD/vehicle) Storage (Gal. /vehicle) ERC/1000 vehicles served Vehicles served/day ERCs Roadway Rest Stop w/ flushometer valves 7 3.5 8.8 0 0.0 4. Data Input for Calculating ERCs, Source and Storage 4.2 Summary - Existing Sources (enter in green cells below) Bicknell Town Water System Total Existing Source Capacity (in gpm) 4.1 Projected ERCs Calculation (optional)WS001 Lower Spring Total Projected ERCs 259 WS003 Spring 1 Existing Residential Connections 180 WS004 Spring 2 Obligated Future ERCs (enter below)79 WS005 Spring 3 Commercial 33 WS006 Spring 4 Instituitional 23 WS007 Brinkerhoff Spring Agriculture 23 Maximum ERCs (assuming indoor use only) 4.3 Summary - Existing Storage Tanks (enter below) Total Existing Storage Cap. (in gallons) ST001 Tank 1 ST002 Tank2 Bicknell Town Capacity Calcs.xlsx Page 3 of 9/23/2024 Division of Drinking Water — Water System Capacity Calculation Sheet (Last Update 3/30/2017) (Example: water use of 2 factories equals to water use of 55 homes.) Map Zones 1 2 3 4 5 6 This source capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Bicknell Town Capacity Calcs.xlsx Page 4 of 9/23/2024 This storage capacity assessment is a general overall system calculation. It may not reflect the variations in individual areas or pressure zones. Total # of sites/pads ERCs 0.0 0.0 0.0 0.0 4.2 Summary - Existing Sources (enter in green cells below) 195 9 9 9 9 9 150 351 4.3 Summary - Existing Storage Tanks (enter below) 620,000 320,000 300,000