Loading...
HomeMy WebLinkAboutDERR-2024-010931IMPACT VALVE LEAK DETECTOR Line Tightness Test MONITOR CERTIFICATION 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 9/23/2024 UTAH DEPARTMENT OF ENV. QUALITY UST PO Box 144840 SALT LAKE CITY, UT 84114 Test Date: 9/19/2024 Order Number: 2371344 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7-ELEVEN 47165/9444 874 EAST 1300 SOUTH State ID 4000765 SALT LAKE CITY, UT 84105 Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting Product Line Tightness Test Page 1 of 1 Work Order: 2371344 Date: 9/19/2024 Site Name/ID: 7-ELEVEN 47165/9444 / 47165/9444 Address: 874 EAST 1300 SOUTH State ID 4000765 City: SALT LAKE CITY State: UT Zip: 84105 Tank Information Test Method Customer Tank ID Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Tank # 1 Line # 1 TLD-1 T1 Regular RUL Pressure 50 10:52 11:22 0.00 Pass Yes Tank # 2 Line # 1 TLD-1 T2 Premium PUL Pressure 50 10:52 11:22 0.00 Pass Yes Tank # 3 Line # 1 TLD-1 T3 Diesel Low Sulfur Diesel Pressure 50 10:52 11:22 0.00 Pass Yes Tank # Line # Tank # Line # Tank # Line # Technician Comments: UT151 Technician Name:David Mathie Certification #:41442 exp: 10/20/2025 Technician Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com 7-ELEVEN 47165/9444 874 EAST 1300 SOUTH State ID 4000765 SALT LAKE CITY UT 84105 47165/9444 Tanknology, Inc. SPEEDWAY Legacy 500 SPEEDWAY DRIVE ENON OH 45323 937-863-6513 09/19/2024 RUL PUL Veeder Root PLLD Veeder Root PLLD Veeder Root PLLD 30 2 30 2 2 30 UT151 David Mathie NW1-2371344 Low Sulfur Diesel TT1 Regular:1 TT2 Premium:1 TT3 Diesel:1 Impact Valve Inspection Impact Valve Operational Inspection Work Order:2371344 Date:9/19/2024 Site Name/ID:7-ELEVEN 47165/9444 Address:874 EAST 1300 SOUTH State ID 4000765 City:SALT LAKE CITY State:UT Zip:84105 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 85 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 85 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 40 Pass Fail Not Tested 5/6 85 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 40 Pass Fail Not Tested 7/8 85 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested Technician Comments: Technician Name:David Mathie Signature: Environmental Compliance for Petroleum Systems ©2024 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com 7-ELEVEN 47165/9444 SPEEDWAY Legacy 874 EAST 1300 SOUTH State ID 4000765 SALT LAKE CITY UT 84105 4000765 Tanknology, Inc. 500 SPEEDWAY DRIVE ENON OH 45323 937-863-6513 800-964-1250 09/19/2024 1 2 3 RUL PUL DSL VR350 VR350 VR350 15041 8050 7099 118.4 118.4 118.4 UT151 David Mathie 874 EAST 1300 SOUTH State ID 4000765 7-ELEVEN 47165/9444 874 EAST 1300 SOUTH State ID 4000765, SALT LAKE CITY, UT 8410547165/9444 Tanknology, Inc. SPEEDWAY Legacy 500 SPEEDWAY DRIVE ENON, OH 45323 937-863-6513 09/19/2024 ANNULAR ANNULAR STP STP STP RUL PUL/DSL RUL PUL DSL UT151 David Mathie Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:2371344 Site ID / Name:47165/9444 / 7-ELEVEN 47165/9444 Address:874 EAST 1300 SOUTH State ID 4000765 City:SALT LAKE CITY State:UT Zip:84105 W.O.# NW1-2371344 SENSORS ALARMS SETUP W.O.# NW1-2371344 PLLD ALARMS SETUP